Manuals and User Guides for Agilent Technologies N1912A. We have 3 Agilent Technologies N1912A manuals available for free PDF download: Programming Manual, User Manual, Configuration Manual
Agilent Technologies N1912A Programming Manual (803 pages)
P-Series Power Meters
Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 5.3 MB
Table of Contents
-
-
General Safety Considerations
5
-
-
-
Power Meter Remote Operation
29
-
Configuring the Remote Interface
34
-
Zeroing and Calibrating the P-Series Power Sensor
37
-
Table 1-1 Measure? and Configure Preset States
39
-
Table 1-2 Possibilities of the Defaulted Source List Parameter
44
-
Using the Configure Command
45
-
Using the Lower Level Commands
54
-
Using Frequency Dependent Offset Tables
55
-
Editing Frequency Dependent Offset Tables
57
-
Enabling a Frequency Dependent Offset Table
60
-
Making the Measurement
60
-
Selecting a Frequency Dependent Offset Table
60
-
Setting the Range, Resolution and Averaging
62
-
Setting Measurement Limits
68
-
Checking for Limit Failures
70
-
Table 1-3 Range of Values for Window Limits
70
-
Getting the Best Speed Performance
72
-
Table 1-4 Model of Sensor and Measurement Rates
73
-
How Measurements Are Calculated
77
-
The General Status Register Model
78
-
The Condition Polling Method
81
-
Table 1-5 Bit Definitions — Status Byte Register
87
-
Table 1-6 Bit Definitions — Standard Event Register
88
-
Table 1-7 Bit Definitions — Questionable Status Registers
90
-
Table 1-8 Bit Change Conditions for Questionable Status Register
90
-
Table 1-9 Bit Definitions — Operation Status
91
-
Table 1-10 Bit Change Conditions for Operation Status
92
-
Device Status Register
93
-
Table 1-11 Bit Definitions — Device Status Register
93
-
Table 1-12 Bit Change Conditions for Device Status Register
94
-
Using the Operation Complete Commands
95
-
How to Save and Recall a Configuration
97
-
Saving and Recalling Power Meter Configurations
97
-
Using Device Clear to Halt Measurements
98
-
An Introduction to the SCPI Language
99
-
Using a Semicolon (;)
100
-
Syntax Diagram Conventions
101
-
Input Message Terminators
107
-
SCPI Compliance Information
109
-
Making Measurements on Wireless Communication Standards
112
-
Starting a Preset Example
113
-
-
-
2 Measurement Commands
115
-
Configure [1] |2|3|4 Commands
125
-
Configure[1]|2|3|4[:Scalar][:Power:ac] [<Expected_Value>[,<Resolution>[,<Source List>]]]
126
-
Configure[1]|2|3|4[:Scalar][:Power:ac]:Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]
128
-
Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference [<Expected_Value>[,<Resolution>[,<Source List>]]]
130
-
Configure[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative [<Expected_Value>[,<Resolution>[,<Source List>]]]
132
-
Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio [<Expected_Value>[,<Resolution>[,<Source List>]]]
134
-
Configure[1]|2|3|4[:Scalar][:Power:ac]:Ratio: Relative[<Expected_Value>[,<Resolution>[,<Source List>]]]
136
-
Fetch[1]|2|3|4 Queries
138
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]
139
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
141
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]
144
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
147
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]
150
-
Fetch[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
153
-
READ[1]|2|3|4 Commands
156
-
Read[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]
157
-
Read[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
160
-
Read[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]
163
-
Read[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
166
-
Read[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]
169
-
Read[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
172
-
Measure[1]|2|3|4 Commands
175
-
Measure[1]|2|3|4[:Scalar][:Power:ac]? [<Expected_Value>[,<Resolution>[,<Source List>]]]
176
-
Measure[1]|2|3|4[:Scalar][:Power:ac]:Relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
178
-
Measure[1]|2|3|4[:Scalar][:Power:ac]:Difference? [<Expected_Value>[,<Resolution>[,<Source List>]]]
180
-
Measure[1]|2|3|4[:Scalar][:Power:ac]:Difference: Relative Expected_Value>[,<Resolution>[,<Source List>]]]
182
-
Measure[1]|2|3|4[:Scalar][:Power:ac]:Ratio? [<Expected_Value>[,<Resolution>[,<Source List>]]]
184
-
Measure[1]|2|3|4[:Scalar][:Power:ac]:Ratio:relative? [<Expected_Value>[,<Resolution>[,<Source List>]]]
186
-
-
-
3 Calculate Subsystem
189
-
Calculate[1]|2|3|4:Feed[1]|2 <String
193
-
Calculate[1]|2|3|4:Gain Commands
196
-
Calculate[1]|2|3|4:Gain[:Magnitude] <Numeric_Value
197
-
Calculate[1]|2|3|4:Gain:state <Boolean
199
-
Calculate[1]|2|3|4:Limit Commands
201
-
Calculate[1]|2|3|4:Limit:clear:auto <Boolean>|Once
202
-
Calculate[1]|2|3|4:Limit:clear[:Immediate]
204
-
Calculate[1]|2|3|4:Limit:fail
205
-
Calculate[1]|2|3|4:Limit:fcount
206
-
Calculate[1]|2|3|4:Limit:lower[:Data] <Numeric_Value
208
-
Table 3-13 Measurement Units
208
-
Calculate[1]|2|3|4:Limit:upper[:Data] <Numeric_Value
211
-
Table 3-14 Measurement Units
211
-
Calculate[1]|2|3|4:Limit:state <Boolean
214
-
Calculate[1]|2|3|4:Math Commands
216
-
Calculate[1]|2|3|4:Math[:Expression] <String
217
-
Calculate[1]|2|3|4:Math[:Expression]:Catalog
220
-
Calculate[1]|2|3|4:Phold:clear
221
-
Calculate[1]|2|3|4:Relative Commands
222
-
Calculate[1]|2|3|4:Relative[:Magnitude]:Auto <Boolean>|Once
223
-
Calculate[1]|2|3|4:Relative:state <Boolean
225
-
4 Calibration Subsystem
227
-
Calibration Subsystem
228
-
Calibration[1]|2[:All]
230
-
Calibration[1]|2[:All]
232
-
Calibration[1]|2:Auto [ONCE|ON|OFF|0|1]
234
-
Calibration[1]|2:Rcalibration <Boolean
237
-
Calibration[1]|2:Rcfactor <Numeric_Value
239
-
Calibration[1]|2:Zero:auto [ONCE|ON|OFF|0|1]
241
-
Calibration[1]|2:Zero:normal:auto <Boolean
243
-
-
-
Display:enable <Boolean
247
-
Display:screen:format <Character_Data
249
-
Display[:Window[1]|2] Commands
251
-
Display[:Window[1]|2]:Analog Commands
252
-
Display[:Window[1]|2]:Analog:lower <Numeric_Value
253
-
Table 5-15 Measurement Units
253
-
Display[:Window[1]|2]:Analog:upper <Numeric_Value
256
-
Table 5-16 Measurement Units
256
-
Display[:Window[1]|2]:Format <Character_Data
259
-
Display[:Window[1]|2]:Meter Commands
262
-
Display[:Window[1]|2]:Meter:lower <Numeric_Value
263
-
Table 5-17 Measurement Units
263
-
Display[:Window[1]|2]:Meter:upper <Numeric_Value
266
-
Table 5-18 Measurement Units
266
-
Display[:Window[1]|2][:Numeric[1]|2]:Resolution <Numeric_Value
269
-
Display[:Window[1]|2]:Select[1]|2
271
-
Display[:Window[1]|2][:State] <Boolean
273
-
Display[:Window[1]|2]:Trace:feed <Character_Data
275
-
-
Format[:Readings]:Border <Character_Data
279
-
Format[:Readings][:Data] <Character_Data
281
-
-
-
Memory:catalog Commands
286
-
Table 7-19 8480 Series Power Sensor Tables
288
-
Table 7-20 8480 Series Power Sensor Tables
291
-
Memory:clear Commands
293
-
Memory:clear[:Name] <Character_Data
294
-
Memory:state Commands
302
-
Memory:state:define <Character_Data>,<Numeric_Value
304
-
Memory:table Commands
306
-
Memory:table:frequency <Numeric_Value>{,<Numeric_Value
307
-
Table 7-21 Frequency and Calibration/Offset Factor List
308
-
Memory:table:frequency:points
311
-
Memory:table:gain[:Magnitude] <Numeric_Value>{,<Numeric_Value
312
-
Table 7-22 Frequency and Calibration/Offset Factor List
312
-
Memory:table:gain[:Magnitude]:Points
315
-
Memory:table:move <Character_Data>,<Character_Data
316
-
Memory:table:select <Character_Data
318
-
-
Output:recorder[1]|2:Feed <Data_Handle
321
-
Output:recorder[1]|2:Limit:lower <Numeric_Value
323
-
Output:recorder[1]|2:Limit:upper <Numeric_Value
325
-
Output:recorder[1]|2:State <Boolean
327
-
Output:roscillator[:State] <Boolean
329
-
Output:trigger[:State] <Boolean
331
-
9 Pstatistic Subsystem
333
-
Pstatistic:ccdf:gaussian[:State] <Boolean
337
-
Pstatistic:ccdf:gaussian:marker[1]|2[:Set]
339
-
Pstatistic:ccdf:marker:delta
341
-
Pstatistic:ccdf:marker[1]|2:Data
343
-
Pstatistic:ccdf:marker[1]|2:X <Numeric_Value
345
-
Pstatistic:ccdf:marker[1]|2:Y <Numeric_Value
347
-
Pstatistic:ccdf:reference:data
349
-
Pstatistic:ccdf:reference[:State] <Boolean
351
-
Pstatistic:ccdf:reference:marker[1]|2[:Set]
353
-
Pstatistic:ccdf:reference:power:average
355
-
Pstatistic:ccdf:reference:power:peak
356
-
Pstatistic:ccdf:reference:power:ptaverage
357
-
Pstatistic[1]|2:Ccdf:continuous <Boolean
358
-
Pstatistic[1]|2:Ccdf:count <Numeric_Value
360
-
Pstatistic[1]|2:Ccdf:data
362
-
Pstatistic[1]|2:Ccdf:data:max <Numeric_Value
364
-
Pstatistic[1]|2:Ccdf:power? <Numeric_Value
366
-
Pstatistic[1]|2:Ccdf:probability? <Numeric_Value
368
-
Pstatistic[1]|2:Ccdf:store:reference
370
-
Pstatistic[1]|2:Ccdf:table
372
-
Pstatistic[1]|2:Ccdf:trace[:State] <Boolean
375
-
Pstatistic[1]|2:Ccdf:trace:marker[1]|2[:Set]
377
-
Pstatistic[1]|2:Ccdf:trace:power:average
379
-
Pstatistic[1]|2:Ccdf:trace:power:peak
381
-
Pstatistic[1]|2:Ccdf:trace:power:ptaverage
383
-
-
[Sense[1]]|Sense2:Average Commands
390
-
[Sense[1]]|Sense2:Average:count <Numeric_Value
391
-
[Sense[1]]|Sense2:Average:count:auto <Boolean
394
-
[Sense[1]]|Sense2:Average:sdetect <Boolean
397
-
[Sense[1]]|Sense2:Average[:State] <Boolean
399
-
[Sense[1]]|Sense2:Average2 Commands
401
-
[Sense[1]]|Sense2:Average2:Count <Numeric_Value
402
-
[Sense[1]]|Sense2:Average2[:State] <Boolean
404
-
[Sense[1]]|Sense2:Bandwidth|Bwidth:video <Character_Data
406
-
[Sense[1]]|Sense2:Buffer:count <Numeric_Value
409
-
[Sense[1]]|Sense2:Buffer:mtype <String
412
-
[Sense[1]]|Sense2:Correction Commands
415
-
[Sense[1]]|Sense2:Correction:cfactor|Gain[1][:Input][:Magnitude] <Numeric_Value
416
-
[Sense[1]]|Sense2:Correction:cset[1]|Cset2 Commands
419
-
[Sense[1]]|Sense2:Correction:cset[1]|Cset2[:Select] <String
420
-
[Sense[1]]|Sense2:Correction:cset[1]|Cset2:State <Boolean
423
-
[Sense[1]]|Sense2:Correction:dcycle|Gain3 Commands
425
-
[Sense[1]]|Sense2:Correction:dcycle|Gain3[:Input] [:Magnitude] <Numeric_Value
426
-
[Sense[1]]|Sense2:Correction:dcycle|Gain3:State <Boolean
429
-
[Sense[1]]|Sense2:Correction:fdoffset|Gain4[:Input][:Magnitude]
431
-
[Sense[1]]|Sense2:Correction:gain2 Commands
432
-
[Sense[1]]|Sense2:Correction:gain2:State <Boolean
433
-
[Sense[1]]|Sense2:Correction:gain2[:Input] [:Magnitude] <Numeric_Value
435
-
[Sense[1]]|Sense2:Detector:function <Character_Data
438
-
[Sense[1]]|Sense2:Frequency[:Cw|:Fixed] <Numeric_Value
440
-
[Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Start <Numeric_Value
443
-
[Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Step <Numeric_Value
446
-
[Sense[1]]|Sense2:Frequency[:Cw|:Fixed]:Stop <Numeric_Value
450
-
[Sense[1]]|Sense2:Mrate <Character_Data
453
-
[Sense[1]]|Sense2:Power:ac:range <Numeric_Value
456
-
[Sense[1]]|Sense2:Power:ac:range:auto <Boolean
458
-
[Sense[1]]|Sense2:Sweep[1]|2|3|4 Commands
460
-
[Sense[1]]|Sense2:Sweep[1]|2|3|4:Auto <Character_Data
461
-
[Sense[1]]|Sense2:Sweep[1]|2|3|4:Auto:ref1|Ref2
464
-
[Sense[1]]|Sense2:Sweep[1]|2|3|4:Offset:time <Numeric_Value
466
-
[Sense[1]]|Sense2:Sweep[1]|2|3|4:Time <Numeric_Value
468
-
[Sense[1]]|Sense2:Temperature
470
-
[Sense[1]]|Sense2:Trace Commands
472
-
[Sense[1]]|Sense2:Trace:offset:time <Numeric_Value
473
-
[Sense[1]]|Sense2:Trace:time <Numeric_Value
475
-
[Sense[1]]|Sense2:Trace:unit <Character_Data
477
-
[Sense[1]]|Sense2:V2P Atype|Dtype
479
-
Sense[1]|2:Trace:autoscale
481
-
Sense[1]|2:Trace:limit:lower <Numeric_Value
483
-
Table 10-23Measurement Units
483
-
Sense[1]|2:Trace:limit:upper <Numeric_Value
486
-
Table 10-24Measurement Units
486
-
Sense[1]|2:Trace:X:scale:pdiv <Numeric_Value
489
-
Sense[1]|2:Trace:y:scale:pdiv <Numeric_Value
491
-
-
Table 11-25Commands and Events Affecting Status Register
494
-
Status Register Set Commands
496
-
Device Status Register Sets
501
-
Operation Register Sets
503
-
Status:operation:calibrating[:Summary]
505
-
Status:operation:llfail[:Summary]
506
-
Status:operation:measuring[:Summary]
507
-
Status:operation:sense[:Summary]
508
-
Status:operation:trigger[:Summary]
509
-
Status:operation:ulfail[:Summary]
510
-
Questionable Register Sets
512
-
Status:questionable:calibration[:Summary]
514
-
Status:questionable:power[:Summary]
515
-
-
System:communicate:gpib[:Self]:Address <Numeric_Value
522
-
System:communicate:lan:aip[:State] <Boolean
524
-
System:communicate:lan:current:address
525
-
System:communicate:lan:current:dgateway
526
-
System:communicate:lan:current:dname
527
-
System:communicate:lan:current:smask
528
-
System:communicate:lan:address <Character_Data
529
-
System:communicate:lan:dgateway <Character_Data
531
-
System:communicate:lan:dhcp[:State] <Boolean
533
-
System:communicate:lan:dname <Character_Data
534
-
System:communicate:lan:hname <Character_Data
536
-
System:communicate:lan:mac
538
-
System:communicate:lan:restart
539
-
System:communicate:lan:smask <Character_Data
540
-
System:preset <Character_Data
554
-
Table 12-26Default: Power Meter Presets
557
-
Table 12-27GSM900: Power Meter Presets
561
-
Table 12-28GSM900: Power Meter Presets: Window/Measurement Settings
562
-
Table 12-29GSM900: Power Meter Presets for Secondary Channel Sensors
563
-
Table 12-30EDGE: Power Meter Presets
564
-
Table 12-31EDGE: Power Meter Presets: Window/Measurement Settings
566
-
Table 12-32EDGE: Power Meter Presets for Secondary Channel Sensors
566
-
Table 12-33Cdmaone: Power Meter Presets
568
-
Table 12-34Cdmaone: Power Meter Presets: Window/Measurement Settings
569
-
Table 12-35 Cdmaone: Power Meter Presets for Secondary Channel Sensors
570
-
Table 12-36 Cdma2000: Power Meter Presets
572
-
Table 12-37 Cdma2000: Power Meter Presets: Window/Measurement Settings
573
-
Table 12-38 Cdma2000: Power Meter Presets for Secondary Channel Sensors
574
-
Table 12-39 W-CDMA: Power Meter Presets
576
-
Table 12-40 W-CDMA: Power Meter Presets: Window/Measurement Settings
577
-
Table 12-41 W-CDMA: Power Meter Presets for Secondary Channel Sensors
578
-
Table 12-42 Bluetooth: Power Meter Presets
580
-
Table 12-43 Bluetooth: Power Meter Presets: Window/Measurement Settings
581
-
Table 12-44 Bluetooth: Power Meter Presets for Secondary Channel Sensors
582
-
Table 12-45 MPCA: Power Meter Presets
583
-
Table 12-46 MPCA: Power Meter Presets: Window/Measurement Settings
584
-
Table 12-47 MCPA: Power Meter Presets for Secondary Channel Sensors
585
-
Table 12-48 RADAR: Power Meter Presets
586
-
Table 12-49 RADAR: Power Meter Presets: Window/Measurement Settings
587
-
Table 12-50 RADAR: Power Meter Presets for Secondary Channel Sensors
588
-
Table 12-51 802.11A and Hiperlan2: Power Meter Presets
590
-
Table 12-52 802.11A and Hiperlan2: Power Meter Presets: Window/Measurement Settings
591
-
Table 12-53 802.11A and Hiperlan2: Power Meter Presets for Secondary Channel Sensors
592
-
Table 12-54 802.11B/G: Power Meter Presets
593
-
Table 12-55 802.11B/G: Power Meter Presets: Window/Measurement Settings
594
-
Table 12-56 802.11B/G: Power Meter Presets for Secondary Channel Sensors
595
-
Table 12-57 1Xev-DO: Power Meter Presets
596
-
Table 12-58 1Exv-DO: Power Meter Presets: Window/Measurement Settings
597
-
Table 12-59 1Exv-DO: Power Meter Presets for Secondary Channel Sensors
598
-
Table 12-60 1Exv-DV: Power Meter Presets
599
-
Table 12-61 1Xev-DV: Power Meter Presets: Window/Measurement Settings
600
-
Table 12-62 1Xev-DV: Power Meter Presets for Secondary Channel Sensors
601
-
Table 12-63 TD-SCDMA: Power Meter Presets
602
-
Table 12-64 TD-SCDMA: Power Meter Presets: Window/Measurement Settings
603
-
Table 12-65 TD-SCDMA: Power Meter Presets: Window/Measurement Settings
604
-
Table 12-66 NADC: Power Meter Presets
605
-
Table 12-67 NADC: Power Meter Presets: Window/Measurement Settings
607
-
Table 12-68 NADC: Power Meter Presets for Secondary Channel Sensors
607
-
Table 12-69 Iden: Power Meter Presets
609
-
Table 12-70 Iden: Power Meter Presets: Window/Measurement Settings
611
-
Table 12-71 Iden: Power Meter Presets for Secondary Channel Sensors
611
-
Table 12-72 DVB: Power Meter Presets
613
-
Table 12-73 DVB: Power Meter Presets: Window/Measurement Settings
614
-
Table 12-74 DVB: Power Meter Presets for Secondary Channel Sensors
615
-
Table 12-75 Wimax: Power Meter Presets
616
-
Table 12-76 Wimax: Power Meter Presets: Window/Measurement Settings
617
-
Table 12-77 Wimax: Power Meter Presets for Secondary Channel Sensors
618
-
Table 12-78 DME: Power Meter Presets
619
-
Table 12-79 DME: Power Meter Presets: Window/Measurement Settings
620
-
Table 12-80 DME: Power Meter Presets for Secondary Channel Sensors
621
-
Table 12-81 DME-PRT: Power Meter Presets
623
-
Table 12-82 DME-PRT: Power Meter Presets: Window/Measurement Settings
624
-
Table 12-83 DME-PRT: Power Meter Presets for Secondary Channel Sensors
625
-
Table 12-84 HSPDA: Power Meter Presets
627
-
Table 12-85 HSPDA: Power Meter Presets: Window/Measurement Settings
628
-
Table 12-86 HSDPA: Power Meter Presets for Secondary Channel Sensors
629
-
Table 12-87LTE: Power Meter Presets
630
-
Table 12-88 LTE: Power Meter Presets: Window/Measurement Settings
631
-
Table 12-89 LTE: Power Meter Presets for Secondary Channel Sensors
632
-
-
Trace[1]|2[:Data]? <Character_Data
640
-
Trace[1]|2:Define:duration:reference<Numeric_Value
642
-
Trace[1]|2:Define:transition:reference <Numeric_Value>, <Numeric_Value
644
-
Trace[1]|2:Measurement:instant:reference? <Numeric_Value
646
-
Trace[1]|2:Measurement:pulse[1]|…|10:Dcycle
648
-
Trace[1]|2:Measurement:pulse[1]|…|10:Duration
650
-
Trace[1]|2:Measurement:pulse[1]|…|10:Period
652
-
Trace[1]|2:Measurement:pulse[1]|…|10:Separation
654
-
Trace[1]|2:Measurement:transition[1]|…|10:Negative:duration
656
-
Trace[1]|2:Measurement:transition[1]|…|10:Negative:occurrence
658
-
Trace[1]|2:Measurement:transition[1]|…|10:Positive:duration
660
-
Trace[1]|2:Measurement:transition[1]|…|10:Positive:occurrence
662
-
Trace[1]|2:Measurement:reference? <Numeric_Value
664
-
Trace[1]|2:State <Boolean
666
-
Trace[1]|2:Unit <Character_Data
668
-
-
-
Initiate[1]|2:Continuous <Boolean
676
-
Initiate[1]|2[:Immediate]
679
-
Initiate:continuous:all <Boolean
680
-
Initiate:continuous:sequence[1]|2 <Boolean
682
-
Initiate[:Immediate]:All
684
-
Initiate[:Immediate]:Sequence[1]|2
685
-
Trigger[1]|2:Delay:auto <Boolean
687
-
Trigger[1]|2[:Immediate]
689
-
Trigger[1]|2:Source Bus|External|Hold|Immediate|Internal[[1]|2]
690
-
Trigger[:Sequence]:Delay <Numeric_Value
693
-
Trigger[:Sequence]:Holdoff <Numeric_Value
695
-
Trigger[:Sequence]:Hysteresis <Numeric_Value
697
-
Trigger[:Sequence]:Level <Numeric_Value
699
-
Trigger[:Sequence]:Level:auto <Boolean
701
-
Trigger[:Sequence]:Slope <Character_Data
703
-
Trigger[:Sequence[1]|2]:Count <Numeric_Value
705
-
Trigger[:Sequence[1]|2]:Delay:auto <Boolean
708
-
Trigger[:Sequence[1]|2]:Immediate
710
-
Trigger[:Sequence[1]|2]:Source Bus|External|Hold|Immediate|Internal[[1]|2]
711
-
-
Service:bist:calibrator <Boolean
719
-
Service:bist:cw[1]|2:Linearity
721
-
Service:bist:cw[1]|2:Linearity:perror
722
-
Service:bist:cw[1]|2:Zset:number
723
-
Service:bist:peak[1]|2:Linearity <Numeric_Value
724
-
Service:bist:peak[1]|2:Linearity:perror
725
-
Service:bist:peak[1]|2:Zset
726
-
Service:bist:peak[1]|2:Zset:number
727
-
Service:bist:tbase:state
728
-
Service:bist:tbase:state <Boolean
729
-
Service:bist:trigger:test
731
-
Service:calibrator:adj:cour <Numeric_Value
732
-
Service:calibrator:adj:fine <Numeric_Value
733
-
Service:lan:phostname
734
-
Service:option <Character_Data
735
-
Service:sensor[1]|2:Calfactor <Cal_Factor_Data
738
-
Service:sensor[1]|2:Cdate
740
-
Service:sensor[1]|2:Corrections:state <Boolean
741
-
Service:sensor[1]|2:Cplace
743
-
Service:sensor[1]|2:Frequency:maximum
744
-
Service:sensor[1]|2:Frequency:minimum
745
-
Service:sensor[1]|2:Pcalfactor <Cal_Factor_Data
746
-
Service:sensor[1]|2:Power:average:maximum
748
-
Service:sensor[1]|2:Power:peak:maximum
749
-
Service:sensor[1]|2:Power:usable:maximum
750
-
Service:sensor[1]|2:Power:usable:minimum
751
-
Service:sensor[1]|2:Radc
752
-
Service:sensor[1]|2:Snumber
753
-
Service:sensor[1]|2:Tnumber
754
-
Service:sensor[1]|2:Type
755
-
Service:snumber <Character_Data
756
-
Service:version:processor <Character_Data
757
-
Service:version:system <Character_Data
758
-
-
-
Unit[1]|2|3|4:Power <Amplitude_Unit
761
-
Unit[1]|2|3|4:Power:ratio <Ratio_Unit
763
-
SCPI Compliance Information
766
-
DDT <Arbitrary Block Program Data>|<String Program Data
768
-
Table 17-90*ESE Mapping
770
-
Table 17-91*ESR? Mapping
772
-
Table 17-92*SRE Mapping
779
-
Table 17-93 *STB? Mapping
781
-
GPIB Universal Commands
786
-
Table 17-94PPD Mapping
787
-
Table 17-95PPE Mapping
788
-
Table A-96 Calibration Factor Block Layout: E4410 Series Sensors
792
-
Table A-97 Calibration Factor Block Layout: E9300 Series Sensors
793
-
Table A-98 Calibration Factor Block Layout: E9320 Series Sensors
794
-
Agilent Technologies N1912A User Manual (297 pages)
P-Series Power Meters
Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 4.12 MB
Table of Contents
-
Restricted Rights Legend
5
-
Recommended Calibration Interval
6
-
General Safety Information
10
-
Environmental Conditions
11
-
Regulatory Information
11
-
Declaration of Conformity (Doc)
13
-
-
LXI Class-C Compliant Power Meter
28
-
Power Meter and Sensor Capability
29
-
Conventions Used in this Guide
30
-
Front Panel Keys and Connections
31
-
Figure 1-1 Dual Numeric Display
36
-
Figure 1-2 Single Numeric and Analog Display
38
-
Figure 1-3 Full Screen Numeric Display
39
-
Figure 1-4 Trace Display in both Windows
40
-
Figure 1-5 Trace Display in Single Enlarged Window in Markers Mode
41
-
Figure 1-6 Trace Display in Single Enlarged Window in Trigger Delay Mode
42
-
Figure 1-7 Trace Display in Single Enlarged Window in Trace Control Mode
43
-
Window Symbols and Pop-Ups
44
-
Using the Instrument Web Browser
48
-
Figure 1-8 Opening the Instrument Web Interface
48
-
Figure 1-9 N1912A P-Series Power Meter Web Browser (Welcome Page)
49
-
Figure 1-10 Status Message before Toggle ID Is Selected
50
-
Figure 1-11 Status Message When Toggle ID Is Selected
50
-
Figure 1-12 Example of Lan Status Message
51
-
Table 1-1 Type of Lan Status Message
51
-
Figure 1-13 Viewing LAN Configuration Settings from the Web Interface
52
-
Figure 1-14 Password Security Dialog Box
53
-
Figure 1-15 Changing the Instrument LAN Interface Configuration
54
-
-
2 General Power Meter Functions
56
-
Setting the Units of Measurement
56
-
Table 2-2 Measurement Units — Single Channel Meters
56
-
Table 2-3 Measurement Units — Dual Channel Meters
56
-
Setting the Measurement Frequency
58
-
Figure 2-16 Frequency Pop-Up
58
-
Setting the Resolution
59
-
Making Relative Measurements
60
-
Figure 2-17 Typical Relative Measurement Display
60
-
Figure 2-18 Numeric Display
61
-
Setting the Pulse Reference Levels
62
-
Figure 2-19 Measurement Configuration Screen
62
-
Figure 2-20 Pulse Duration Measurement between Two Reference Levels
63
-
Figure 2-21 Trace Ref Lvl 1 Pop-Up
63
-
Figure 2-22 Trace Ref Lvl 2 Pop-Up
64
-
Figure 2-23 Pulse Duration Ref Lvl Pop-Up
64
-
Figure 2-24 Simplified Measurement Path
65
-
Figure 2-25 Typical Channel Offset Display
66
-
Figure 2-26 Channel Offset Indicator
67
-
Figure 2-27 Typical Display Offset Display
68
-
Figure 2-28 Frequency Dependent Offset Tables Display
70
-
Figure 2-29 Frequency Dependent Offset Indicator
71
-
Figure 2-30 «Edit Offset» Display with Data Added
72
-
Figure 2-31 Edit Table Title Pop-Up
73
-
Setting Measurement Averaging
75
-
Figure 2-32 Typical Averaged Readings
75
-
Figure 2-33 Meas Avg Count Pop-Up
76
-
Setting the Video Averaging
78
-
Figure 2-34 Video Avg Count Pop-Up
79
-
Setting the Video Bandwidth
80
-
Table 2-4 P-Series Sensor Video Bandwidth Setting
80
-
Figure 2-35 Bandwidth Filter Shapes
81
-
Figure 2-36 Video Bandwidth Pop-Up
82
-
Setting Measurement Channel Gates
83
-
Figure 2-37 Example of Measurement Gates
83
-
Figure 2-38 Gate Setup Screen
84
-
Figure 2-39 Time Gating Start Pop-Up
85
-
Figure 2-40 Time Gating Length Pop-Up
85
-
Figure 2-41 Auto Gate Settings Display
86
-
Figure 2-42 Marker 1 Ref Percentage Pop-Up
86
-
Figure 2-43 Marker 2 Ref Percentage Pop-Up
87
-
Figure 2-44 the Placement of Gates (Markers) in Auto Gating Mode
87
-
Setting up the Channel Trace
88
-
Figure 2-45 Trace Setup Display
88
-
Figure 2-46 Trace Start Time Pop-Up
89
-
Figure 2-47 X Scale/Division Pop-Up
89
-
Figure 2-48 Trace Units Pop-Up
90
-
Figure 2-49 y Scale Maximum Value Pop-Up
90
-
Figure 2-50 y Scale/Division Pop-Up
91
-
Figure 2-51 Trigger Menu — Free Run Mode
92
-
Figure 2-52 Trigger Setting Menu 1
93
-
Figure 2-53 Trigger Level Pop-Up
94
-
Figure 2-54 Trigger Delay Pop-Up
95
-
Figure 2-55 Trigger Setting Menu 2
95
-
Figure 2-56 Trigger Holdoff Pop-Up
96
-
Figure 2-57 Trigger Hysteresis Pop-Up
97
-
Setting External Trigger for Normal and Average Power Measurement
98
-
Table 2-5 Power and Frequency Sweep Mode Compatibility Table
98
-
Table 2-6 Power and Frequency Sweep Measurement Functions Table
99
-
Figure 2-58 TRIG in and TRIG out Connection Diagram between Power Meter and
100
-
-
Figure 2-59 Channel Setup Display
100
-
Figure 2-60 Sensor Mode Pop-Up
101
-
Figure 2-61 Trigger Setting Menu 1
102
-
Figure 2-62 Trigger Setting Menu 2
102
-
Figure 2-63 Limits Checking Applications
112
-
Figure 2-64 Limits Checking Results
112
-
Setting Measurement Limits
112
-
Table 2-7 Range of Values for Window Limits
113
-
Figure 2-65 Minimum Limit Pop-Up
114
-
Figure 2-66 Limit Failures
115
-
Figure 2-67 Sixteen Measurements Per Channel
116
-
Setting the Measurement Display
116
-
Figure 2-68 Measurement Feed Example
117
-
Figure 2-69 Measurement Setup Showing Single Configuration
118
-
Figure 2-70 Function Pop-Up
119
-
Figure 2-71 Measurement Type Pop-Up
119
-
Figure 2-72 Gating Number Pop-Up
120
-
Figure 2-73 Measurement Setup Showing Combined Configuration
121
-
Figure 2-74 Measurement Example Display
122
-
Figure 2-75 Maximum Limit Pop-Up
123
-
Figure 2-76 Minimum Limit Pop-Up
123
-
Scaling the Analog Display
123
-
Figure 2-77 Increment and Decrement Multiplier
124
-
Figure 2-78 Recorder Minimum Pop-Up
126
-
Figure 2-79 Recorder Maximum Pop-Up
126
-
Table 2-8 Ranges of Recorder Output Setting
127
-
Figure 2-80 Increment and Decrement Multiplier
128
-
Figure 2-83 Save/Recall Screen
130
-
Saving and Recalling Power Meter States
130
-
Figure 2-84 Save Confirm Pop-Up
131
-
Figure 2-85 File Name Pop-Up
131
-
Figure 2-86 Recall Pop-Up
132
-
Figure 2-87 Zeroing Pop-Up
133
-
Zeroing and Calibrating the P-Series Sensor
133
-
Figure 2-88 Calibration Wait Pop-Up
134
-
Figure 2-89 Please Zero and Calibrate Window
136
-
Figure 2-90 Preset Display Options
137
-
Presetting the Power Meter
137
-
Table 2-9 Preset Compatibility Matrix for E-Series E9320 Power Sensor
138
-
Setting the Cable Short/Long
139
-
-
-
3 Using P-Series Power Sensor
141
-
Configuring a Power Measurement
143
-
Setting the Trace Display
144
-
Figure 3-92 P-Series Sensor Default Channel Setup
145
-
Figure 3-93 Trace Display in Dual Channel Power Meter
146
-
Figure 3-94 Trace Display in Single Enlarged Window
147
-
Figure 3-95 Trace Display with Gate Control Menu
148
-
Figure 3-96 Trace Display with Trigger Delay Menu
149
-
Figure 3-97 Trace Display with Trace Control Menu
151
-
Figure 3-98 Trace Display in Full Screen
152
-
Figure 3-99 P-Series Power Sensor Default Channel Setup
153
-
Figure 3-100Channel Offset Display
154
-
4 Using E9320 E-Series Power Sensors
158
-
Table 4-10 Sensor Bandwidth
158
-
Figure 4-101 Bandwidth Filter Shapes
159
-
Power Meter Configuration
160
-
Figure 4-102 E-Series E9320 Power Sensor Default Channel Setup
160
-
Configuring a Peak Power Measurement
161
-
Setting the Trace Display
164
-
Figure 4-104 E-Series E9320 Power Sensor Channel Setup When Trigger Is Selected
166
-
Figure 4-105Trace Display in Dual Channel Power Meter
166
-
Figure 4-106Trace Display in Single Enlarged Window
167
-
Figure 4-107Trace Display with Gate Control Menu
168
-
Figure 4-108Trace Display with Trigger Delay Menu
169
-
Figure 4-109Trace Display with Trace Control Menu
171
-
Figure 4-110Trace Display in Full Screen
172
-
Figure 4-111E-Series E9320 Power Sensor Dafault Channel Setup
173
-
Figure 4-112Channel Offset Display
174
-
5 Using E9300 E-Series Power Sensors
179
-
Power Meter Configuration
179
-
Figure 5-113E9300 E-Series Auto-Averaging Settings
179
-
Figure 5-114 E9300 E-Series Sensor Default Channel Setup
180
-
Table 5-11 Power Sensor Connection Requirements
181
-
Figure 5-115Frequency Pop-Up
182
-
Measuring Spread Spectrum and Multitone Signals
183
-
Figure 5-116Spread Spectrum Signal
183
-
Figure 5-117 Wideband CDMA Error of E-Series E9300 Power Sensor Versus Corrected
184
-
Figure 5-118CDMA (IS-95A): 9Ch Fwd
184
-
Figure 5-119Calibration Factors Versus Frequency
185
-
Measuring TDMA Signals
186
-
Electromagnetic Compatibility (EMC) Measurements
188
-
Measurement Accuracy and Speed
189
-
-
6 Using E4410 E-Series Power Sensors
194
-
Power Meter Configuration
195
-
Figure 6-120E-Series CW Sensor Auto-Averaging Settings
195
-
Figure 6-121E-Series E4410 Sensor Default Channel Setup
196
-
Figure 6-122Frequency Pop-Up
198
-
7 Using 8480 Series Power Sensors
200
-
Power Meter Configuration
201
-
Figure 7-1238480 Series Auto-Averaging Settings
201
-
Figure 7-1248480 Series Sensor Default Channel Setup
202
-
Table 7-12 8480 Series Connection Requirements
203
-
Frequency Specific Calibration Factors
206
-
Figure 7-125Reference Calibration Factor Pop-Up Window
207
-
Figure 7-126Calibration Factor Pop-Up Window
208
-
Figure 7-127Calibration Factor Display
208
-
Sensor Calibration Tables
210
-
Figure 7-128Sensor Table Selected
211
-
Figure 7-129Frequency Dependent Offset Indicator
211
-
Figure 7-130Frequency/Calibration Table Display
212
-
Table 7-13 Installed Power Sensor Models
213
-
Figure 7-131″Sensor Tbls» Screen
214
-
Figure 7-132″Edit Cal» Display
215
-
Figure 7-133Edit Table Title Pop-Up
215
-
8 Using N8480 Series Power Sensors
222
-
Table 8-14 Power Range in the Range Setting
222
-
Power Meter Configuration Changes
224
-
Figure 8-134Auto-Averaging Settings
224
-
Default Channel Setup
225
-
Figure 8-135N8480 Series Sensor (Excluding Option CFT) Default Channel Setup
225
-
N8480 Series Sensors Connection Requirements
226
-
Table 8-15 N8480 Series Connection Requirements
226
-
N8480 Series Power Sensors (Excluding Option CFT)
227
-
Figure 8-137Frequency Pop-Up
228
-
N8480 Series Power Sensors with Option CFT
229
-
Figure 8-138Reference Calibration Factor Pop-Up Window
230
-
Figure 8-139Calibration Factor Pop-Up Window
231
-
Figure 8-140Calibration Factor Displayed
232
-
Figure 8-141Sensor Table Selected
235
-
Figure 8-142Frequency Dependent Offset Indicator
236
-
Figure 8-143Frequency/Calibration Table Display
237
-
Table 8-16 Installed Power Sensor Models
238
-
Figure 8-144″Sensor Tbls» Screen
239
-
Figure 8-145″Edit Cal» Display
240
-
Figure 8-146Edit Table Title Pop-Up
240
-
9 Complementary Cumulative Distribution Function (CCDF)
243
-
Setting the CCDF Table
245
-
Figure 9-147CCDF Table in Windowed Display
245
-
Figure 9-148CCDF Table in Expanded Display
246
-
Figure 9-149CCDF Table in Full-Screen Display
247
-
Setting the CCDF Trace
248
-
Figure 9-150Trace Display Select Control Menu
248
-
Figure 9-151CCDF Trace Display with Marker Trace Menu
249
-
Figure 9-152Scale/DIV Pop-Up
251
-
Figure 9-153Selection of CCDF Trace to be Stored as a Reference Trace
252
-
-
Figure 10-154Self Test Complete
255
-
Figure 10-155Error Indicator Position
258
-
Figure 10-156Replacing the Fuse
270
-
Contacting Agilent Technologies
271
-
Figure 10-157Secure Erase Status Pop-Up
274
-
Returning Your Power Meter for Service
275
-
Agilent Sales and Service Offices
277
-
11 Specifications and Characteristics
280
-
Power Meter Specifications
282
-
Measurement Characteristics
285
-
Figure 11-158Measured Rise Time Percentage Error Versus Signal under Test Rise Time
287
-
Rear Panel Inputs and Output Connections
288
-
Environmental Conditions
290
-
Physical Characteristics
291
-
Regulatory Information
292
-
System Specifications and Characteristics
293
-
Figure 11-159P-Series Sensor Error in Peak-To-Average Measurements for a Two-Tone Input
294
Agilent Technologies N1912A Configuration Manual (5 pages)
P-Series Power Meters and Wideband Power Sensors
Brand: Agilent Technologies
|
Category: Measuring Instruments
|
Size: 0.12 MB
Table of Contents
Related Products
-
Agilent Technologies N1911A
-
Agilent Technologies N1913a
-
Agilent Technologies N1914a
-
Agilent Technologies N1996A-503
-
Agilent Technologies N1996A-506
-
Agilent Technologies N5230A
-
Agilent Technologies N5242A
-
Agilent Technologies N3383A
-
Agilent Technologies N9000A
-
Agilent Technologies N9010AK-REA
Agilent Technologies Categories
Measuring Instruments
Laboratory Equipment
Test Equipment
Water Pump
Power Supply
More Agilent Technologies Manuals
Производителю ВЧ аппаратуры необходима уверенность, что выпускаемые им изделия имеют характеристики, которые удовлетворяют потребности заказчика. Сегодня разработка и производство ВЧ и микроволновых систем выдвигает требования к испытанию все более широкополосных сигналов и точным измерениям мощности в импульсе, чего не могут обеспечить измерители средней мощности. Одноканальные и двухканальные измерители мощности серий Agilent P, EPM и EPM.P с абсолютной погрешностью измерения ±0,2 дБ (±0,5 %) обеспечивают достоверные результаты при испытании современных радиоэлектронных систем, в том числе использующих широкополосные сигналы.
Серия P: измерение пиковой и средней мощности широкополосных сигналов
Измерители мощности серии P (N1911A и N1912A) совместно с семейством первичных преобразователей мощности (в дальнейшем — преобразователи) компании Agilent обеспечивают быстрые, точные и повторяющиеся измерения, необходимые в процессе НИОКР и производства аппаратуры аэрокосмической и оборонной техники, систем радиосвязи и сетей стандарта 802.11a/b/g, обеспечивая потребности радиолокации и испытания компонентов импульсной техники и усилителей многочастотных систем. Измерители мощности серии P совместно с преобразователями обеспечивают всеобъемлющие измерения мощности, временные и статистические измерения, включая измерения пиковой, средней и отношения пиковой к средней мощности, максимальной и минимальной мощности, в том числе с временным стробированием и с автономным запуском, измерение длительности фронта и среза и дополняющей интегральной функции распределения (CCDF). Непрерывная дискретизация с частотой до 100 МГц и самая широкая среди приборов этого класса полоса видеотракта 30 МГц позволяют захватывать повторяющиеся и однократные широкополосные сигналы. Совместимость со всеми преобразователями компании Agilent серии 8480 и серии E обеспечивает дополнительный выбор для измерения средней мощности в широком динамическом диапазоне и диапазоне частот от 9 кГц до 110 ГГц.
Серия EPM-P: многоцелевое назначение и высокая производительность
Измерители мощности серии EPM-P (E4416A и E4417A) совместно с семейством первичных преобразователей мощности Agilent E9320 имеют моноблочную конструкцию и обеспечивают измерение пиковой, отношения пиковой к средней и средней мощности, в том числе с использованием временного стробирования. Широкие возможности запуска упрощают просмотр интересующих фрагментов сигнала.
Серия EPM: достоверные измерения средней мощности
Если у пользователя возникает необходимость измерения средней мощности, недорогие измерители серии EPM (E4418B и E4419B) обеспечат получение точных и повторяющихся результатов.
Особенности измерителя мощности N1912A
- Интуитивно-понятные операции для быстрой установки режима и получения достоверных результатов
- Восемь встроенных конфигураций для испытания систем радиосвязи, включая Bluetooth
- Графический дисплей плюс экран анализа с возможностью реальновременных измерений дельта»маркером интервалов времени, пикового, среднего значений мощности и отношения пикового к среднему
- Программное обеспечение для анализа параметров импульсов и статистического анализа
- Manuals
- Brands
- Agilent Technologies Manuals
- Measuring Instruments
- 1912A
Manuals and User Guides for Agilent Technologies 1912A. We have 2 Agilent Technologies 1912A manuals available for free PDF download: Programming Manual, User Manual
AGILENT TEСHNOLOGIES N1912A – Измеритель мощности
Назначение и особенности измерителя мощности N 1912 A
Двухканальный измеритель мощности N 1912A с преобразователями мощности N192xA обеспечивает широкополосные высококачественные измерения, которые необходимы при проверки соответствия продукции требованиям по мощности.
Особенности измерителя мощности N1912 A
- Полоса пропускания видеосигнала 30 МГц;
- Дискретизация в реальном масштабе времени однократных процессов со скоростью 100 миллионов выборок в секунду;
- Установка нуля и калибровка при подключенном к контролируемому устройству приборе;
- Измерения максимальной, средней мощности и отношения максимальной мощности к средней мощности, временные измерения длительности фронта, длительности спада, длительности импульса, периода повторения импульсов, коэффициента заполнения, времени появления положительного и отрицательного значения и статистический анализ при помощи дополняющей интегральной функции распределения (CCDF);
- Простая организация измерений с 22 предварительными установками, включающими WiMAX и WLAN;
- Возможность подключения к USB, локальной сети и GPIB;
- Измерения максимальной, средней мощности и отношения максимальной мощности к средней мощности;
- Режимы свободных и стробированных во времени измерений;
- Автоматическое измерение длительности фронта, длительности спада, времени до появления положительного значения и времени до появления отрицательного значения.
Общие данные |
|
Число каналов |
2 |
Диапазон частот |
от 50 МГц до 40 ГГц |
Максимальная частота дискретизации |
100 миллионов выборок в секунду, непрерывная дискретизация |
Полоса пропускания видеосигнала |
Не менее 30 МГц |
Полоса пропускания одиночного перепада |
Не менее 30 МГц |
Длительность фронта |
Не более 13 нс (для частот > 500 МГц) |
Длительность спада |
Не более 13 нс (для частот > 500 МГц) |
Минимальная длительность импульса |
50 нс |
Динамический диапазон |
от −35 до +20 дБм (> 500 МГц); от −30 до +20 дБм (50 −500 МГц) |
Максимальная длительность захваченного сигнала |
1 секунда |
Максимальная частота повторения импульсов |
10 МГц ( при 10 выборках на периоде) |
Погрешность |
10х10-6 |
Джиттер |
Не более 1 нс |
Габаритные размеры |
88,5 мм В х 212,6 мм Ш х 348,3 мм Г |
Масса нетто |
не более 3,7 кг |
Масса в упаковке |
не более 8 кг |
Комплектация измерителя мощности N1912A
- Измеритель N1912A;
- Транспортный ящик основного прибора;
- Сумка для принадлежностей;
- Руководство по эксплуатации.
Технические параметры (спецификация) и комплект поставки товара могут быть изменены производителем без предварительного уведомления.
Информация носит справочный характер и не является публичной офертой, определяемой положениями Статьи 437 Гражданского кодекса Российской Федерации.
Документы, файлы, паспорт, инструкция N1912A
N1912A Измеритель мощности серии P, два канала от 3мкВт до 100 мВт
Измерители мощности Agilent Technologies серий EPM и EPM-P и P
- Интуитивно»понятные операции для быстрой установки режима и получения достоверных результатов
- Восемь встроенных конфигураций для испытания систем радиосвязи, включая Bluetooth
- Графический дисплей плюс экран анализа с возможностью реальновременных измерений дельта»маркером интервалов времени, пикового, среднего значений мощности и отношения пикового к среднему
- Программное обеспечение для анализа параметров импульсов и статистического анализа
Производителю ВЧ аппаратуры необходима уверенность, что выпускаемые им изделия имеют характеристики, которые удовлетворяют потребности заказчика. Сегодня разработка и производство ВЧ и микроволновых систем выдвигает требования к испытанию все более широкополосных сигналов и точным измерениям мощности в импульсе, чего не могут обеспечить измерители средней мощности. Одноканальные и двухканальные измерители мощности серий Agilent P, EPM и EPM.P с абсолютной погрешностью измерения ±0,2 дБ (±0,5 %) обеспечивают достоверные результаты при испытании современных радиоэлектронных систем, в том числе использующих широкополосные сигналы.
Серия P: измерение пиковой и средней мощности широкополосных сигналов
Измерители мощности серии P (N1911A и N1912A) совместно с семейством первичных преобразователей мощности (в дальнейшем — преобразователи) компании Agilent обеспечивают быстрые, точные и повторяющиеся измерения, необходимые в процессе НИОКР и производства аппаратуры аэрокосмической и оборонной техники, систем радиосвязи и сетей стандарта 802.11a/b/g, обеспечивая потребности радиолокации и испытания компонентов импульсной техники и усилителей многочастотных систем. Измерители мощности серии P совместно с преобразователями обеспечивают всеобъемлющие измерения мощности, временные и статистические измерения, включая измерения пиковой, средней и отношения пиковой к средней мощности, максимальной и минимальной мощности, в том числе с временным стробированием и с автономным запуском, измерение длительности фронта и среза и дополняющей интегральной функции распределения (CCDF). Непрерывная дискретизация с частотой до 100 МГц и самая широкая среди приборов этого класса полоса видеотракта 30 МГц позволяют захватывать повторяющиеся и однократные широкополосные сигналы. Совместимость со всеми преобразователями компании Agilent серии 8480 и серии E обеспечивает дополнительный выбор для измерения средней мощности в широком динамическом диапазоне и диапазоне частот от 9 кГц до 110 ГГц.
Технические характеристики измерителя мощности N1912A:
Общие данные | |
Число каналов | 2 |
Диапазон частот | от 50 МГц до 40 ГГц |
Максимальная частота дискретизации | 100 миллионов выборок в секунду, непрерывная дискретизация |
Полоса пропускания видеосигнала | Не менее 30 МГц |
Полоса пропускания одиночного перепада | Не менее 30 МГц |
Длительность фронта | Не более 13 нс (для частот > 500 МГц) |
Длительность спада | Не более 13 нс (для частот > 500 МГц) |
Минимальная длительность импульса | 50 нс |
Динамический диапазон | от −35 до +20 дБм (> 500 МГц); от −30 до +20 дБм (50 −500 МГц) |
Максимальная длительность захваченного сигнала | 1 секунда |
Максимальная частота повторения импульсов | 10 МГц ( при 10 выборках на периоде) |
Погрешность | 10х10-6 |
Джиттер | Не более 1 нс |
Габаритные размеры | 88,5 мм В х 212,6 мм Ш х 348,3 мм Г |
Масса нетто | не более 3,7 кг |
Масса в упаковке | не более 8 кг |
Комплектация измерителя мощности N1912A:
- Измеритель N1912A;
- Транспортный ящик основного прибора;
- Сумка для принадлежностей;
- Руководство по эксплуатации.
Agilent N1911A | 1 канал, пиковая и средняя мощность, от 3мкВт до 100 мВт | По запросу |
На любые вопросы о приборе Измеритель мощности Agilent N1912A, его цене и наличию вам всегда ответят наши специалисты по телефонам +7 (495) 504-37-31 и +7 (812) 309-05-16
Производителю ВЧ аппаратуры необходима уверенность, что выпускаемые им изделия имеют характеристики, которые удовлетворяют потребности заказчика. Сегодня разработка и производство ВЧ и микроволновых систем выдвигает требования к испытанию все более широкополосных сигналов и точным измерениям мощности в импульсе, чего не могут обеспечить измерители средней мощности. Одноканальные и двухканальные измерители мощности серий Agilent P, EPM и EPM.P с абсолютной погрешностью измерения ±0,2 дБ (±0,5 %) обеспечивают достоверные результаты при испытании современных радиоэлектронных систем, в том числе использующих широкополосные сигналы.
Серия P: измерение пиковой и средней мощности широкополосных сигналов
Измерители мощности серии P (N1911A и N1912A) совместно с семейством первичных преобразователей мощности (в дальнейшем — преобразователи) компании Agilent обеспечивают быстрые, точные и повторяющиеся измерения, необходимые в процессе НИОКР и производства аппаратуры аэрокосмической и оборонной техники, систем радиосвязи и сетей стандарта 802.11a/b/g, обеспечивая потребности радиолокации и испытания компонентов импульсной техники и усилителей многочастотных систем. Измерители мощности серии P совместно с преобразователями обеспечивают всеобъемлющие измерения мощности, временные и статистические измерения, включая измерения пиковой, средней и отношения пиковой к средней мощности, максимальной и минимальной мощности, в том числе с временным стробированием и с автономным запуском, измерение длительности фронта и среза и дополняющей интегральной функции распределения (CCDF). Непрерывная дискретизация с частотой до 100 МГц и самая широкая среди приборов этого класса полоса видеотракта 30 МГц позволяют захватывать повторяющиеся и однократные широкополосные сигналы. Совместимость со всеми преобразователями компании Agilent серии 8480 и серии E обеспечивает дополнительный выбор для измерения средней мощности в широком динамическом диапазоне и диапазоне частот от 9 кГц до 110 ГГц.
Серия EPM-P: многоцелевое назначение и высокая производительность
Измерители мощности серии EPM-P (E4416A и E4417A) совместно с семейством первичных преобразователей мощности Agilent E9320 имеют моноблочную конструкцию и обеспечивают измерение пиковой, отношения пиковой к средней и средней мощности, в том числе с использованием временного стробирования. Широкие возможности запуска упрощают просмотр интересующих фрагментов сигнала.
Серия EPM: достоверные измерения средней мощности
Если у пользователя возникает необходимость измерения средней мощности, недорогие измерители серии EPM (E4418B и E4419B) обеспечат получение точных и повторяющихся результатов.
Особенности измерителя мощности N1912A
- Интуитивно-понятные операции для быстрой установки режима и получения достоверных результатов
- Восемь встроенных конфигураций для испытания систем радиосвязи, включая Bluetooth
- Графический дисплей плюс экран анализа с возможностью реальновременных измерений дельта»маркером интервалов времени, пикового, среднего значений мощности и отношения пикового к среднему
- Программное обеспечение для анализа параметров импульсов и статистического анализа
Назначение
Описание
Технические характеристики
Знак утверждения типа
Комплектность
Поверка
Нормативные документы
Заключение
Назначение
Ваттметры N1911 А, N1912А с преобразователями N1921 А, N1922А (далее -ваттметры) предназначены для измерения среднего и пикового (при амплитудной модуляции) значений мощности электромагнитных колебаний ВЧ и СВЧ.
Применяются для проведения настройки, технического обслуживания, ремонта и контроля качества высокочастотного оборудования.
Описание
Принцип действия ваттметров основан на преобразовании мощности ВЧ и СВЧ сигналов в напряжение, с дальнейшим преобразованием его АЦП. Ваттметры N1911 A, N1912A имеют одинаковую конструкцию, технические характеристики, но отличаются количеством измерительных каналов. Ваттметр N1911А имеет один канал, а ваттметр N1912A — два.
Рабочие условия применения:
— температура окружающей среды от 0 до плюс 55 °С;
— относительная влажность воздуха до 95 %
— атмосферное давление (100 ± 30) кПа.
Технические характеристики
• Диапазоны частот:
С преобразователем |
Диапазон частот |
N1921A |
от 50 МГц до 18,0 ГГц |
N1922А |
от 50 МГц до 40,0 ГГц |
(при комплектации коаксиально-волноводными переходами R281A, Q281A).
• Динамический диапазон измеряемых значений мощности сигнала:
— в диапазоне частот от 50 до 500 МГц — от 1 O’6 до ОД Вт;
— в диапазоне частот выше 500 МГц — от 3 ■ 10″7 до 0,1 Вт.
• Пределы допускаемой относительной погрешности измерения мощности:
— в диапазоне частот от 50 МГц до 18 ГГц + 5 %;
— в диапазоне частот от 18 до 40 ГГц ±6%.
• Максимально-допустимая входная мощность:
— в диапазоне частот от 50 до 500 МГц — не более 0,2 Вт;
— в диапазоне частот больше 500 МГц — не более 1 Вт.
• Длительность импульсов не менее 50 не.
• Максимальная частота повторения импульсов 10 МГц.
• Время фронта и среза не более 13 не (при частотах более 500 МГц и установки «Off» для ширины полосы пропускания видеосигналов).
• Максимальная частота повторения выборок 100 МГц.
• Выходная мощность встроенного калибратора 1 мВт, частота 50 МГц.
• Полное входное сопротивление 50 Ом.
• КСВН входа не более 1,26 в диапазоне частот от 50 МГц до 18 ГГц, 1,5 в диапазоне частот от 18 до 40 ГГц.
• Тип тракта 7/3,04 мм у преобразователя N1921 А, 2,4/1,04 мм у преобразователя N1922A («male»).
• Питание от встроенного источника постоянного тока или от сети переменного тока напряжением (90 — 264) В, частотой (47 — 63) Гц, потребляемая мощность не более 75 В А.
• Г абаритные размеры, (длина х ширина х высота): не более (349x213x89) мм.
• Масса без преобразователей, не более 3,7 кг.
Знак утверждения типа
Знак утверждения типа наносится на титульный лист руководства по эксплуатации 5989-2471 РЭ типографским или иным способом, на ваттметр по технологии фирмы-изготовителя.
Комплектность
В состав комплекта поставки входят:
— ваттметр N1911А (N1921 А)
— 1пгг,
-1 пгг*,
— 2 пгг*, -1 шт,
-1 шт,
-1 шт.
— приемный преобразователь N1921А (N1922А)
— переходы коаксиально-волноводные R2 81 A, Q281А
— жесткий диск с программным обеспечением
— руководство по эксплуатации 5989-2471 РЭ
— методика поверки 5989-2471 МП
* по заказу.
Поверка
Поверка осуществляется в соответствии с документом «Ваттметры N1911 A, N1912A с преобразователями N1921 А, N1922А. Методика поверки» 5989-2471 МП, утвержденным ФГУП «ВНИИФТРИ» 7.04.2010 г.
Основное поверочное оборудование: генератор сигналов E8257D (диапазон частот 250 кГц до 40 ГГц), ваттметры проходные образцовые ВПО-1, ВПО-2, ВПО-3, ВПО-4, (погрешность ± 1,6 %); ваттметры образцовые проходные М1-10Б, М1-11Б (погрешность + 1,6 %); прибор для поверки ваттметров Ml-25/1 (погрешность + 2,5 %); измерители КСВН Р2-83, Р2-65,..67 (погрешность ± 5 %); аттенюаторы поляризационные Д3-33,..36А (погрешность + 0,3 дБ); генератор сигналов SMB100A (длительность радиоимпульса 10 не).
Межповерочный интервал — один год.
Нормативные документы
ГОСТ 22261-94 «Средства измерений электрических и магнитных величин. Общие технические условия».
Техническая документация фирмы «Agilent Technologies,» (Малайзия).
Заключение
Тип ваттметров N1911 A, N1912A с преобразователями N1921 A, N1922A утвержден с техническими и метрологическими характеристиками, приведенными в настоящем описании типа, метрологически обеспечен при выпуске из производства и в эксплуатации.