-
Инструкции по эксплуатации
1
APC Line-R LE 600 I 350Вт 600ВА инструкция по эксплуатации
(1 страница)
- Языки:Русский
-
Тип:
PDF -
Размер:
102.43 KB -
Описание:
Стабилизатор напряжения
Просмотр
На NoDevice можно скачать инструкцию по эксплуатации для APC Line-R LE 600 I 350Вт 600ВА. Руководство пользователя необходимо для ознакомления с правилами установки и эксплуатации APC Line-R LE 600 I 350Вт 600ВА. Инструкции по использованию помогут правильно настроить APC Line-R LE 600 I 350Вт 600ВА, исправить ошибки и выявить неполадки.
- About
- Blog
- Projects
- Help
-
Donate
Donate icon
An illustration of a heart shape - Contact
- Jobs
- Volunteer
- People
Bookreader Item Preview
texts
APC Line-R 600 User`s manual
- Addeddate
- 2021-01-16 23:08:18
- Identifier
- manualzz-id-1080181
- Identifier-ark
- ark:/13960/t1sg2s69b
- Ocr
- tesseract 4.1.1
- Ocr_autonomous
- true
- Ocr_detected_lang
- en
- Ocr_detected_lang_conf
- 1.0000
- Ocr_detected_script
- Latin
- Ocr_detected_script_conf
- 0.9988
- Ocr_module_version
- 0.0.10
- Ocr_parameters
- -l eng+Latin
- Ppi
- 300
comment
Reviews
There are no reviews yet. Be the first one to
write a review.
50
Views
DOWNLOAD OPTIONS
Uploaded by
chris85
on January 16, 2021
SIMILAR ITEMS (based on metadata)
More products and manuals for Surge protectors APC
Models | Document Type |
---|---|
SURGEARREST PMF3S-A |
Instruction Manual
20 pages |
SURGEARREST PMG4DS-A |
User Manual
4 pages |
SURGEARREST PML4S-A |
User Manual
4 pages |
P6V |
User Manual
2 pages |
P7GB |
User Manual
5 pages |
P11VT3 |
User Manual
2 pages |
P610 |
User Manual
1 pages |
BR800I |
User Manual
2 pages |
0217A7 |
User Manual
2 pages |
G5BLK |
Datasheet
42 pages |
BMG3-A |
Datasheet
2 pages |
PER7-LM |
Datasheet
2 pages |
PER8TVR |
Datasheet
1 pages |
P5BV-IT |
Datasheet
6 pages |
P1-IT |
Datasheet
6 pages |
SurgeArrest Essential |
Specifications
6 pages |
PM6-GR |
Specifications
6 pages |
P7T-LM |
Specifications
2 pages |
P1T-RS |
Specifications
6 pages |
PMF3XS-B |
Manual
24 pages |
Thank you for purchasing APC by Schneider Electrics Line-R Automatic Voltage Regulator! Fill out and mail the product warranty registration form, or fill out an online form at www.apc.com.
The Line-R automatically corrects brownouts (by boosting low voltage) and overvoltages (by stepping down high voltage) from the power utility service to levels that are safe for computers, as well as other sensitive equipment. APC by Schneider Electrics Line-R provides the highest degree of protection from line voltage sags and swells, and has been designed for many years of reliable, maintenance-free service.
Applications
The Line-R is designed for use with voltage sensitive equipment such as a: computer, monitor, inkjet printer, scanner or fax. It is also designed for use with home electronics (TVs, stereos, CD players, etc.). Appliances not suitable for use with the Line-R are items such as refrigerators, freezers, power tools, air conditioners, dehumidifiers, blenders, or any device that employs an AC motor for operation. Not for use with life sustaining equipment and any device with a power requirement exceeding the Maximum Output Power Capacity rating listed in the Specifications table.
Features
Power Switch The Line-R provides a front panel power switch (l = on) / (O = off) which functions as the master power switch for the Line-R and all devices connected to the device.
Push Button Circuit Breaker The Line-R provides a push button circuit breaker on the rear panel of the unit to protect it from being overloaded. If the circuit breaker trips, unplug the last device connected to the unit and push the circuit breaker fully inward.
NOTICE RISK OF EQUIPMENT DAMAGE
The total power consumption of all equipment plugged into the Line-R must not exceed the ratings listed in the Specifications table below. A total load in excess of the listed ratings will cause the push button circuit breaker to trip.
Failure to follow these instructions can result in equipment damage.
Line-R
Automatic Voltage Regulator Models LE600I and LE1200I
Lights when input voltage is high.
Flashes when input voltage is above rated Input Voltage Range.
Input voltage is normal.
Lights when input voltage is low.
Flashes when input voltage is below rated Input Voltage Range.
The power switch applies and removes power to/ from the Line-R (l = on) / (O = off).
Power Switch
AC Outlets (4)
(connect equipment here)
User Selectable
Voltage Switch
(see Select Input Voltage) Push Button
Circuit Breaker
Connect Your Detachable Device
Power Cord Here and to an AC Wall Outlet
Connect the Supplied Power Cord from any Outlet to Your
Device
Installation Placement — Install the Line-R in a protected environment free of excessive dust,
mechanical vibration, inflammable gases and explosive or corrosive atmospheres.
Do not block the top or side air vents on the unit. Allow 1 inch (2.5 cm) minimum vent clearance.
Select Input Voltage — The Line-R provides a three-position User Selectable Voltage Switch for adjusting the input voltage for the region where it is being used (example: Russia — 220V, Denmark — 230V, United Kingdom — 240V). Slide the switch to select the proper voltage for your location.
Plug the Line-R into the Wall Outlet — Detach your computer’s power cord from the back of your computer and use it to plug the Line-R into the wall socket. Use one of the two power cords supplied with the Line-R to reconnect your computer to any of the four outlets on the back of the Line-R. The Line-R should only be used in buildings having proper grounding on a branch circuit protected by a fuse or circuit breaker.
Connect Your Equipment — Plug equipment into the Line-R rear-panel outlets and switch the equipment ON. The equipment will not be powered until the Line-R is switched ON.
Switch ON the Line-R — Press the front panel power switch to the on (l) position. This switch may be used as the master switch for the device and all equipment connected to it.
Specifications Characteristics Model LE600I Model LE1200I
Maximum Output Power Capacity 600 W or 600 VA 1200 W or 1200 VA
Nominal Output Voltage 220, 230, or 240V (User Selectable)
Nominal Input Current 2.6 A 5.2 A
Acceptable Voltage Range Tolerance 160 — 270V (Selector Switch set to 220V)
166 — 280V (Selector Switch set to 230V)
170 — 290V (Selector Switch set to 240V)
Rated Input Voltage 250Vac
Maximum Acceptable Input Voltage 300V
Surge Energy 300 Joules
Output Regulation 10%
Response Time < 2 AC Cycles
Efficiency >92%
Nominal Frequency 47 — 63 Hz
Number of Outlets 4
Operating Temperature 32 — 104F (0 — 40C)
Relative Humidity 0 — 95% Non-condensing
Dimensions 4.6 x 8.4 x 5.5 inches (118 x 214 x 141 mm)
Weight 3.1 kg (6.8 lb) 4.2 kg (9.2 lb)
2.5 cm
(1 inch)
Limited Warranty Schneider Electric IT (SEIT) warrants its products to be free from defects in materials and workmanship for a period of two (2) years from the date of purchase. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Return Material Authorization (RMA) number from SEIT or a SEIT service center. Products must be returned to SEIT or an SEIT service center with transportation charges prepaid and must be accompanied by a brief description of the problem encountered and proof of date and place of purchase. This warranty does not apply to equipment which has been damaged by accident, negligence, or misapplication or has been altered or modified in any way. This warranty applies to the original purchaser who must have proper registered the product within 10 days of purchase.
EXCEPT AS PROVIDED HEREIN, SEIT MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF MERCHANTIBILITY AND FITNESS FOR A PARTICULAR PURPOSE. Some countries do not permit limitation or exclusion of implied warranties; therefore, the aforesaid limitation(s) or exclusion(s) may not apply to the purchaser.
EXCEPT AS PROVIDED ABOVE, IN NO EVENT SHALL SEIT BE LIABLE FOR DIRECT, INDIRECT, SPECIAL, INCIDENTAL, OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OF THIS PRODUCT, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE. Specifically, SEIT is not liable for any costs, such as lost profits or revenue, loss of equipment, loss of use of equipment, loss of software, loss of data, costs of substitutes, claims by third parties, or otherwise. This warranty gives you specific legal rights and you may also have other rights which may vary from location to location.
APC by Schneider Electric IT Customer Support Worldwide For country specific customer support, go to the