  • Page 1
    BRAVO 180S SERIES COMPUTER CROP SPRAYING 46718XXXX Software rel. 1.10.x INSTALLATION, USE AND MAINTENANCE…
  • Page 2: Legend Of Symbols

    This manual is an integral part of the equipment to which it refers and must accompany the equipment in case of sale or change of ownership. Keep it for any future reference; ARAG reserves the right to modify product specifications and instructions at any moment and without notice.

  • Page 3: Table Of Contents

    CONTENTS • Legend of symbols …………..2 12 User setting …………….25 12.1 Jobs setup …………..26 • Manual foreword and use …………4 12.2 Nozzle data * …………..27 • Manual use modes …………..4 12.3 Minimum regulation pressure * ……..28 12.4 Wheel selection ** …………28 •…

  • Page 4: Manual Foreword And Use

    • RESPONSIBILITY The installer must carry out workmanlike installations and ensure to the end user the perfect operation of the whole system both with ARAG components only and other brands’ components. ARAG always recommends using its components to install control systems.

  • Page 5: Product Description

    BRAVO DSB ARAG has designed and manufactured a diagnostics system for Bravo series computers and the systems they may be connected to. BRAVO DSB (code 467003) provides reliable diagnostics of computer, control unit or the whole system troubleshooting any potential problems experienced with the BRAVO DSB system.

  • Page 6: Package Content

    INSTALLATION PACKAGE CONTENT The table below indicates the components that you will find in the BRAVO computer package: BRAVO 180S COMPUTER Legend: 1 Bravo 180S 2 Instruction manual (DVD-ROM) 3 Power cable 4 Fixing kit 5 Power supply connector 6 Valve and sensor harness 7 Inductive speed sensor 8 Section valve connector seals Fig.

  • Page 7: Position On Farming Machine

    INSTALLATION POSITION ON FARMING MACHINE System recommended composition ASSEMBLY DIAGRAM FOR SPRAYER WITH DIAPHRAGM PUMP SYSTEM WITH MAIN VALVE Legend: Monitor Battery GPS receiver (optional) Filling pump Flowmeter External general control / external speed sensor Level sensor Pressure sensor Foam marker (crop spraying only) Speed sensor Control valve…

  • Page 8
    INSTALLATION ASSEMBLY DIAGRAM FOR SPRAYER WITH CENTRIFUGAL PUMP Legend: Monitor Battery GPS receiver (optional) Filling pump Flowmeter External general control / external speed sensor Level sensor Pressure sensor Foam marker (crop spraying only) Speed sensor Control valve 1÷5 Section valves Hydraulic unit INTENDED APPLICATIONS Fig.
  • Page 9: Computer Positioning

    • BRAVO 180S series computer must be placed in the control cabin of the farming machine. Observe the following precautions: — Do NOT install the monitor in areas where it would be subjected to excessive vibrations or shocks, to prevent any damage or accidental use of the control keys;…

  • Page 10: Bracket Fixing

    WARNING! DO NOT CONNECT HYDRAULIC UNITS OTHER THAN THE SPECIFIED ONES (SEE ARAG GENERAL CATALOGUE). ARAG IS NOT LIABLE FOR ANY DAMAGE TO THE PRODUCT, MALFUNCTION ERRORS AND ANY KIND OF RISK IF THE MODULE IS CONNECTED TO NON ORIGINAL UNITS OR UNITS NOT SUPPLIED BY ARAG.

  • Page 11: Computer Connection To The Farming Machine

    INSTALLATION COMPUTER CONNECTION TO THE FARMING MACHINE General precautions for a correct harness position • Securing the cables: — secure the harness so that it does not interfere with moving parts; — route the harnesses so that they cannot be damaged or broken by machine movements or twisting. •…

  • Page 12: Power Supply Connection

    INSTALLATION Power supply connection The package includes the power connector (Fig. 1 and Fig. 2 on page 6) to be connected to the farming machine battery; Fig. 13 shows the drilling template of the power connector. Connect the power connector to the battery wires using two 0.250″ faston connectors, as indicated in Fig. 11 and Fig. 12. Use the cable provided with the package (Fig.

  • Page 13: Harness Connection To The Control Unit, The Hydraulic Unit And The Available Functions

    • Take care not to break, pull, tear or cut the cables. • Use of unsuitable cables not provided by ARAG automatically voids the warranty. • ARAG is not liable for damages to the equipment, persons or animals caused by failure to observe the above instructions. Multicore cable connection Connect the multicore cable to the monitor (connections 1 and 2 on page 9) and the other cable end to the control unit and the hydraulic unit.

  • Page 14: Hydraulic Valve Connection

    INSTALLATION Hydraulic valve connection Bravo 180S can control up to 7 hydraulic functions through double-acting valves. Fix the connectors to the relevant valves according to the initials indicated in your assembly general diagram (7.1 System recommended composition). • Position seal ( ) onto connector ( ), then connect the latter pressing it fully home ( during this operation, take special care not to bend valve electric contacts.

  • Page 15: Connection Of Sensors And Other Available Functions

    • pressure sensor; • level sensor • foam marker. All ARAG sensors use the same type of connector. Connect the sensor connector to the relevant harness; make sure it is correctly fitted and push it until locking it. Fig. 18 Fig.

  • Page 16: Setup

    SETUP SETUP 10.1 Computer switching on/off • Ordinary switching on Software version Bravo 180S — — — — — M e n u — — — — — SPR Ver 1.8.0 — — — S p ray i ng — — Fig.

  • Page 17: Use Of Keys For Setup

    SETUP 10.2 Use of keys for setup Language English 1 Press the arrow keys in succession to move across the menu items.   next item, previous item); the selected item will be displayed (Fig. 23). Units of measur. 2 Press to access the menu: during set-up, a cursor blinks on the display (Fig.

  • Page 18: Advanced Setup

    ADVANCED SETUP ADVANCED SETUP The computer can be set-up with the all data required to ensure a correct distribution of the treatment product. This operation must be done once only, when installing the computer. 11.1 Tests and checks before programming Before proceeding with computer programming check the correct installation of all components (control unit and sensors), the connection to the power supply and the connection to the components (general control unit and sensors).

  • Page 19: Language

    ADVANCED SETUP 11.2 Language Language Set the language of Bravo 180S, among those available. English > Italian, English, Spanish, Portuguese, French, German, Polish, Croatian, Hungarian, Greek, Russian, Turkish, Czech. Fig. 29 11.3 Units of measur. Set the units of measurement used for Bravo 180S. Units of measur.

  • Page 20: Device Connect

    ADVANCED SETUP 11.6 Device connect. Enable / disable any connection to an external. Ext. device > Device connect. Serial LOG External device None Ext. device setup enables Bravo 180S to receive the spraying data of the variable application rate from serial LOG a connected device (e.g.: DELTA 80), the item transmits, in turn, to the serial port a string of data…

  • Page 21: Valves

    : indicate the type of installed main control valve. 2-Ways : drain valve (valve TYPE — Arag 463 series) 3-Ways : main valve (valve TYPE — Arag 464 — 471 series) 11.10 Flowmeter Flowmeter Select the type of flowmeter installed:…

  • Page 22: Flowmeter Constant

    ADVANCED SETUP 11.11 Flowmeter constant This parameter sets the flowmeter constant value: it indicates how many pulses are sent by the flowmeter per unit of Flowmeter sprayed fluid. 2271 pls/gal The constant value is indicated on the label on your flowmeter. For the parameter value of ORION flowmeters only, to be entered in the computer, refer to section «Technical data»…

  • Page 23: Tank Source

    ADVANCED SETUP 11.16 Tank source In this menu select a tank level reading mode. Tank source The management of the , described in par. 11.17, will be different according to the selected mode. Tank source Possible options: Manual > Manual Level Sensor The level sensor installed in the system allows displaying the tank level in real time.

  • Page 24: Spraying Menu

    ADVANCED SETUP 9 Immediately after that, the computer passes to the calibration start screen: Calib. phase Calib. phase Activate Main > the display shows the message Activate Main 10 Start the spraying system: open, in succession, ALL section valves and the main control (switches in position Calib.

  • Page 25: User Setting

    USER SETTING USER SETTING Before starting a treatment, some settings are necessary for a correct job. Once all necessary data have been set, it is possible to immediately start spraying. ACCESS TO THE USER MENU User setting (from computer on) •…

  • Page 26: Jobs Setup

    USER SETTING 12.1 Jobs setup In this menu it is possible to set 10 different types of treatments. 1/10 32.1 GPA — First select the job to be set (Fig. 59). Job number Fig. 59 Rate Type Rate Type — After selecting the job, the computer automatically passes to the setting screen of for the selected treatment (Fig.

  • Page 27: Nozzle Data

    USER SETTING 12.2 Nozzle data This menu allows setting and viewing the values of the nozzles being used. Nozzles type Nozzles type — First select , Fig. 62). — Then the computer automatically passes to the selection of the nozzle to be set (Fig. 63). ISO nozzles CAN NOT BE MODIFIED.

  • Page 28: Minimum Regulation Pressure

    USER SETTING 12.3 Minimum regulation pressure This menu allows setting a pressure value below which BRAVO 180S blocks the automatic regulation function Min. reg. press. Disabled : block disabled). Disabled The control is active ONLY during treatment AUTOMATIC control (par. 14.3.1). For the procedure to be followed in case of alarms, please refer to par.

  • Page 29: Level Correction

    USER SETTING 12.7 Level correction Level correction If the sprayed fluid has a different density than the water one, the computer could display wrong measurements; 133.53 oz/gal to correct them change the sprayed fluid weight for 1 l of product. Fig.

  • Page 30: Totalizers

    USER SETTING 12.11 Totalizers • there is a totalizer for each preset job (10 available), plus the «T00» one (that can not be reset) which includes all jobs Totalizers performed by the device. Export • the current job data are summed to the relevant totalizer each time you select a new job (par. 14.1). Export •…

  • Page 31: Use

    13.1 Display Percentage variation according to the set output value Active pendrive 32.1 GPA < Output value during treatment LEFT side of the active foam marker Master OFF > Disabled spraying RIGHT side of the active foam marker Tank level lower 32.1 GPA ƒ…

  • Page 32: Treatment Preliminary Settings

    TREATMENT PRELIMINARY SETTINGS Par. 11.8 Speed sensor 11.5 Boom width 12.1 Job setup TO BE CARRIED OUT 12.2 Nozzle data UPON FIRST USE 12.3 Minimum regulation pressure OF THE COMPUTER After having carried out the indicated settings 12.5 Minimum speed start the treatment selecting between MANUAL 12.8 Display contrast…

  • Page 33: Application Rate Regulation

    14.4 Automatic closure of the main valve BRAVO 180S can automatically switch off the main valve through an external ARAG* navigator: the navigator can autonomously manage valve opening and closing, thus preventing the overlapping of already-sprayed areas. To be able to use the automatic closure, connect the navigator to BRAVO 180S and perform the procedure for AUTOMATIC operation (par.

  • Page 34: Output Menu

    14.5 Output menu This menu contains the description of the functions available during the treatment.   A sub-menu is available for almost all data; to gain access to it press keys at the same time for 1 second. • Instantaneous speed indication The driving speed simulation allows spraying the product even without a Speed simul.

  • Page 35: Tank Filling

    14.5.1 Tank filling Master OFF Spraying Menu Tank level 1 From the , press until selecting Tank level 2 Press the keys at the same time to access the tank filling procedure. Tank source The filling will be managed in different ways according to the mode preset in the menu (par.

  • Page 36: Maintenance / Diagnostics / Repairs

    MAINTENANCE / DIAGNOSTICS / REPAIRS MAINTENANCE / DIAGNOSTICS / REPAIRS 15.1 Operation errors The indicated messages blink alternatively Machine stopped! 0.0 gpa 0.0 MPH 0.0 MPH Fig. 97 MESSAGE ON DISPLAY / Par. REMEDY MODE CAUSE MAN. Disable Main 13.2.2 •…

  • Page 37: Troubleshooting

    MAINTENANCE / DIAGNOSTICS / REPAIRS 15.2 Troubleshooting FAULT CAUSE REMEDY • Check power supply connection (par. 8.2) No power supply The display does not switch on Computer is OFF • Press the ON key Valve controls take no effect Valves not connected •…

  • Page 38: Technical Data

    MAINTENANCE / DIAGNOSTICS / REPAIRS TECHNICAL DATA • Advanced menu Data Description Min. Max. DEFAULT Other values that can be set / Notes English, Italian, Spanish, Portuguese, French, German, Language Display language English Polish, Croatian, Hungarian, Greek, Russian, Turkish, Czech.. Units of measur.

  • Page 39: Computer Technical Data

    TECHNICAL DATA • Output values Data Min. Max. Description Notes 99999,9 US: GPA Quantity of sprayed fluid for unit of Volume applied Shown on the first line of the display, during treatment 0.00 99999,99 US TURF: GPK surface Speed 199,9 US — US TURF: MPH Vehicle driving speed Present only if YES has been set in the advanced…

  • Page 40: End-Of-Life Disposal

    Dispose of the system in compliance with the established legislation in the country of use. GUARANTEE TERMS 1. ARAG s.r.l. guarantees this apparatus for a period of 360 days (1 year) from the date of sale to the client user (date of the goods delivery note).

  • Page 41
    Notes…
  • Page 42
    Only use genuine ARAG accessories or spare parts to make sure manufacturer guaranteed safety conditions are maintained in time. Always refer to ARAG spare parts catalogue. 42048 RUBIERA (Reggio Emilia) — ITALY Via Palladio, 5/A Tel. +39 0522 622011 Fax +39 0522 628944 http://www.aragnet.com…

  • GREAT PLAINS 3P1006NT

    Manufacturing, Inc.www.greatplainsmfg.com© Copyright 2018 Printed 2018-06-06 151-144MENTable of Contents IndexTable of Contents IndexORIGINAL INSTRUCTIONSOperator Manual3P1006NTSemi-Mounted 10-Foot No-Till DrillRead the operation manual entirely. When you see this symbol, thesubsequent instructions and warnings are se …

    3P1006NT Farm Equipment, 102

  • horsch Tiger MT

    This does not replace the operating instructions!Pay attention to the safety instructions and warnings in the operating instructions! Keep the operating instructions on board.Operators must have read and understood the complete operating instructions before working with the machine!Tiger AS / MT with slewing undercarri …

    Tiger MT Farm Equipment, 2

  • Ferrari FUTURA 2016

    FUTURAITENFR2016FERRARICOSTRUZIONI MECCANICHE Strada Squadri, 6 — 46040 GUIDIZZOLOMANTOVA — ITALYTel. +39 0376 819342Fax +39 0376 840205www.ferraricostruzioni.comIstruzioni originaliTranslation of the original instructionsTraduction des instructions originalesÜbersetzung der OriginalanleitungTraducción de las instruc …

    FUTURA 2016 Farm Equipment, 250

  • Barreto 912RM

    912 Operator’s Manual 12/4/14 Page 1 of 12 THE MODEL 912RM/912HM HYDRAULIC TRENCHER OPERATOR’S MANUAL TRENCHER INTENDED USE This machine is designed for digging trenches in “normal” ground of reasonably soft dirt and stones up to 6” (15cm) in diameter. …

    912RM Construction Equipment, 12

  • Checchi & Magli PLASTIC-STOP PLUS

    Cod. 998676/1 MANUALE D’USO E MANUTENZIONE USE AND MAINTENANCE MANUAL MANUEL D’UTILISATION ET D’ENTRETIEN BEDIENUNGS-UND WARTUNGSANLEITUNG MANUAL DE USO Y MANTENIMIENTO04/2015Istruzioni originaliOriginal instructionNotices originalesOriginalanleitungInstrucciones originalesPLASTIC — STOPPLUS …

    PLASTIC-STOP PLUS Farm Equipment, 184

  • Gaspardo FBR Plus

    Cod. G19503010 2010-12USO E MANUTENZIONE — PARTI DI RICAMBIOUSE AND MAINTENANCE — SPARE PARTSGEBRAUCH UND WARTUNG — ERSATZTEILEEMPLOI ET ENTRETIEN — PIECES DETACHEESEMPLEO Y MANTENIMIENTO — PIEZAS DE REPUESTOITENDEFRES*)*) Valido per Paesi UE*) Valid for EU member countries*) Valable dans les Pays UE*) Gilt für EU …

    FBR Plus Farm Equipment, 136

  • Hurricane 3-PT-Swinger

    December 2010 Model Number: 3-PT -Swinger Serial Number: __________ HURRICANE DITCHER CO., INC. 2425 Cathlinette Rd. Vincennes, IN 47591 812-886-9663 Fax 812-886-0530 www.hurricane-ditcher.com e-mail: info@hurricane-d …

    3-PT-Swinger Farm Equipment, 18

  • Schulte SRW1400

    © 2016 Alamo Group Inc.SRW1400Published 08/16 S/N: R20011130602-R20011314712 Inclusive Part No. R200-010COPERATOR’S MANUAL Schulte Industries Ltd.PO Box 70Englefeld SaskatchewanCanada S0K 1N0Tel. (306) 287-3715Fax. (306) 287-3355Parts Fax. (306) 287-4066Web: www.schulte.caPIVOTING ROCK WINDROWERTh …

    SRW1400 Farm Equipment, 90

This manual provides instructions to assemble, connect and set the computers of the BRAVO 180S family.

Any other information is provided in specific sheets to be used exclusively by the installer, containing specific information of each computer model.

MANUAL USE MODES

The section of this manual dedicated to the installation contains information for installers. For this reason we have used technical terms without

providing explanations which would be necessary for end users only.

THE INSTALLATION MUST BE CARRIED OUT BY AUTHORISED AND SKILLED PERSONNEL ONLY. THE MANUFACTURER IS

NOT RESPONSIBLE FOR ANY OPERATION SPECIFIED IN THIS MANUAL CARRIED OUT BY UNAUTHORISED OR UNSKILLED

PERSONNEL.

LIMITATIONS

The descriptions of the assembly phases refer to a «general» computer, so specific models will not be mentioned, unless a certain installation procedure

concerns exclusively one computer type.

RESPONSIBILITY

The installer must carry out workmanlike installations and ensure to the end user the perfect operation of the whole system both with ARAG components

only and other brands’ components.

ARAG always recommends using its components to install control systems.

The installer will be held responsible for any malfunction if he decides to use other brands’ components even without actually changing the system

parts or harness.

The compatibility check with components and accessories of other manufacturers shall be carried out by the installer.

If the computer or the ARAG components installed together with other brands’ components get damaged because of what stated above, no direct or

indirect warranty will be provided.

4

INTRODUCTION

Понравилась статья? Поделить с друзьями:
  • Arsl 109 hotpoint ariston инструкция по применению
  • Arsl 105 ariston инструкция на русском
  • Arsl 100 аристон инструкция по эксплуатации на русском
  • Arsenal gsm auto 12f3 инструкция
  • Arrow helicopter 588 инструкция по применению