- Manuals
- Brands
- Bonfiglioli Manuals
- DC Drives
- act 401
Manuals and User Guides for Bonfiglioli act 401. We have 2 Bonfiglioli act 401 manuals available for free PDF download: Operating Instructions Manual, Quick Start Manual
Bonfiglioli act 401 Operating Instructions Manual (218 pages)
Vectron Active 201/401 Series 230V/400V 0.55 kW … 132. kW frequency inverter
Brand: Bonfiglioli
|
Category: DC Drives
|
Size: 4.71 MB
Table of Contents
-
Installation Instructions
3
-
Table of Contents
4
-
Operating Instructions ACTIVE Operating Instructions ACTIVE 5
7
-
Operating Instructions ACTIVE Operating Instructions ACTIVE 7
9
-
1 General Safety Instructions and Information on Use
10
-
General Information
10
-
Purpose of the Frequency Inverters
11
-
Transport and Storage
11
-
Handling and Installation
11
-
Electrical Connection
12
-
Information on Use
12
-
Maintenance and Service
12
-
-
2 Scope of Supply
13
-
ACT 201 (up to 3.0 Kw) and ACT 401 (up to 4.0 Kw)
13
-
ACT 201 (4.0 up to 9.2 Kw) and ACT 401 (5.5 up to 15.0 Kw)
14
-
ACT 401 (18.5 up to 30.0 Kw)
15
-
ACT 401 (37.0 up to 65.0 Kw)
16
-
ACT 401 (75.0 up to 132.0 Kw)
17
-
-
3 Technical Data
18
-
General Technical Data
18
-
Technical Data of Control Electronics
19
-
ACT 201 (0.55 up to 3.0 Kw, 230 V)
20
-
ACT 201 (4.0 up to 9.2 Kw, 230 V)
21
-
ACT 401 (0.55 up to 4.0 Kw, 400 V)
22
-
ACT 401 (5.5 up to 15.0 Kw, 400 V)
23
-
ACT 401 (18.5 up to 30.0 Kw, 400 V)
24
-
ACT 401 (37.0 up to 65.0 Kw, 400 V)
25
-
ACT 401 (75.0 up to 132.0 Kw, 400 V)
26
-
Operation Diagrams
27
-
-
4 Mechanical Installation
28
-
ACT 201 (up to 3.0 Kw) and ACT 401 (up to 4.0 KW)
28
-
ACT 201 (4.0 up to 9.2 Kw) and ACT 401 (5.5 up to 15.0 Kw)
29
-
ACT 401 (18.5 up to 30.0 Kw)
30
-
ACT 401 (37.0 up to 65.0 Kw)
31
-
ACT 401 (75.0 up to 132.0 Kw)
32
-
-
5 Electrical Installation
33
-
EMC Information
34
-
Block Diagram
35
-
Optional Components
36
-
Connection of the Device
37
-
Dimensioning of the Conductor Cross Section
37
-
Typical Conductor Cross Sections
37
-
-
Mains Connection
38
-
Motor Connection
39
-
Motor Cable Length, Without Filter
39
-
Motor Cable Length, with Output Filter Du/Dt
39
-
Motor Cable Length, with Sine Filter
39
-
Group Drive
40
-
Speed Sensor Connection
40
-
-
Connection of a Brake Resistor
40
-
-
Connection of the Construction Sizes
41
-
ACT 201 (up to 3.0 Kw) and ACT 401 (up to 4.0 Kw)
41
-
ACT 201 (4.0 up to 9.2 Kw) and ACT 401 (5.5 up to 15.0 Kw)
43
-
ACT 401 (18.5 up to 30.0 Kw)
45
-
ACT 401 (37.0 up to 65.0 Kw)
47
-
ACT 401 (75.0 up to 132.0 Kw)
49
-
-
Control Terminals
51
-
Relay Output
52
-
Control Terminals — Terminal Diagram
53
-
Configuration 110 — Sensorless Control
53
-
Configuration 111 — Sensorless Control with Technology Controller
54
-
Configuration 410 — Sensorless Field-Oriented Control
54
-
Configuration 411 — Sensorless Field-Oriented Control with Technology Controller
55
-
Configuration 430 — Sensorless Field-Oriented Control, Speed or Torque Controlled
55
-
Configuration 210 — Field-Oriented Control, Speed Controlled
56
-
Configuration 211 — Field-Oriented Control, with Technology Controller
56
-
Configuration 230 — Field-Oriented Control, Speed and Torque Controlled
57
-
-
-
-
6 Control Unit KP500
58
-
Menu Structure
59
-
Main Menu
59
-
Actual Value Menu (VAL)
60
-
Parameter Menu (PARA)
61
-
Copy Menu (CPY)
62
-
Reading the Stored Information
62
-
Menu Structure
63
-
Selecting the Source
63
-
Selecting the Destination
64
-
Copy Operation
64
-
Error Messages
65
-
-
Read Data from the KP 500 Control Unit
66
-
Activating
66
-
Transfer Data
67
-
Reset to Normal Mode
68
-
-
Control Menu (CTRL)
68
-
Controlling the Motor Via the Control Unit
69
-
-
7 Commissioning of the Frequency Inverter
72
-
Switching on Mains Voltage
72
-
Setup Using the Control Unit
72
-
Configuration
73
-
Data Set
74
-
Motor Type
74
-
Machine Data
75
-
Plausibility Check
76
-
Parameter Identification
77
-
Application Data
79
-
Acceleration and Deceleration
79
-
Set Points at Multi-Functional Input
80
-
Selection of an Actual Value for Display
80
-
-
-
Check Direction of Rotation
81
-
Speed Sensor
82
-
Speed Sensor 1
82
-
Speed Sensor 2
83
-
-
Set-Up Via the Communication Interface
84
-
-
8 Inverter Data
86
-
Serial Number
86
-
Optional Modules
86
-
Inverter Software Version
86
-
Set Password
86
-
Control Level
87
-
User Name
87
-
Configuration
87
-
Language
90
-
Programming
90
-
-
9 Machine Data
91
-
Rated Motor Parameters
91
-
Further Motor Parameters
92
-
Stator Resistance
92
-
Leakage Coefficient
92
-
Magnetizing Current
93
-
Rated Slip Correction Factor
93
-
-
Internal Values
94
-
Speed Sensor 1
94
-
Operation Mode Speed Sensor 1
94
-
Division Marks, Speed Sensor 1
95
-
-
-
10 System Data
96
-
Actual Value System
96
-
Volume Flow and Pressure
96
-
-
11 Operational Behavior
97
-
Starting Behavior
97
-
Starting Behavior of Sensorless Control System
97
-
Starting Current
99
-
Frequency Limit
99
-
-
Flux Formation
99
-
-
Stopping Behavior
100
-
Switch-Off Threshold
102
-
Holding Time
102
-
-
Direct Current Brake
102
-
Auto Start
103
-
Search Run
104
-
Positioning
105
-
Reference Positioning
106
-
Error and Warning Behavior
111
-
-
-
Overload Ixt
111
-
Temperature
111
-
Controller Status
112
-
IDC Compensation Limit
112
-
Frequency Switch-Off Limit
112
-
Motor Temperature
113
-
Phase Failure
113
-
Automatic Error Acknowledgment
114
-
-
13 Reference Values
115
-
Frequency Limits
115
-
Slip Frequency
115
-
Percentage Value Limits
115
-
Frequency Reference Channel
116
-
Block Diagram
117
-
-
Reference Percentage Channel
119
-
Block Diagram
119
-
-
Fixed Reference Values
121
-
Fixed Frequencies
121
-
JOG-Frequency
121
-
Fixed Percentages
122
-
-
Frequency Ramps
122
-
Percentage Value Ramps
125
-
Block Frequencies
125
-
Motor Potentiometer
126
-
Motorpoti (MP)
127
-
Motorpoti (KP)
127
-
Controlling the Motor Via the Control Unit
128
-
-
Repetition Frequency Input
129
-
-
14 Control Inputs and Outputs
130
-
Multi-Function Input MFI1
130
-
Analog Input MFI1A
130
-
Characteristic
130
-
Scaling
132
-
Tolerance Band and Hysteresis
132
-
Filter Time Constant
133
-
Error and Warning Behavior
134
-
-
-
Multi-Function Output MFO1
134
-
Analog Output MFO1A
135
-
Output Characteristic
135
-
-
Frequency Output MFO1F
136
-
Scaling
136
-
-
-
Digital Outputs
137
-
Setting Frequency
138
-
Reference Value Reached
138
-
06/07 Operating Instructions ACTIVE
138
-
Flux Formation Ended
139
-
Open Brake
139
-
Current Limitation
139
-
External Fan
139
-
Warning Mask
140
-
-
Digital Inputs
142
-
Start Command
145
-
3-Wire-Control
145
-
Error Acknowledgment
146
-
Timer
146
-
Thermo-Contact
146
-
N-/M-Control Change-Over
146
-
Data Set Change-Over
147
-
Fixed Value Change-Over
148
-
Motor Potentiometer
149
-
-
Function Modules
149
-
Timer
149
-
Time Constant
150
-
-
Comparator
152
-
Logic Modules
153
-
-
-
15 F — Characteristic
158
-
Dynamic Voltage Pre-Control
159
-
-
16 Control Functions
160
-
Intelligent Current Limits
160
-
Voltage Controller
161
-
Technology Controller
165
-
Functions of Sensorless Control
173
-
Slip Compensation
173
-
Current Limit Value Controller
173
-
-
Functions of Field-Orientated Control
174
-
Current Controller
174
-
Torque Controller
176
-
Limit Value Sources
176
-
-
Speed Controller
177
-
Limitation of Speed Controller
179
-
Limit Value Sources
180
-
-
Acceleration Pre-Control
180
-
Field Controller
181
-
Limitation of Field Controller
182
-
-
Modulation Controller
182
-
Limitation of Modulation Controller
183
-
-
-
-
17 Special Functions
184
-
Pulse Width Modulation
184
-
Fan
185
-
Bus Controller
185
-
Brake Chopper and Brake Resistance
187
-
Dimensioning of Brake Resistor
188
-
-
Motor Circuit Breaker
189
-
V-Belt Monitoring
190
-
Motor Chopper
191
-
Temperature Adjustment
192
-
Encoder Monitoring
193
-
Actual Values
194
-
Actual Values of the Frequency Inverter
194
-
Actual Values of the Machine
195
-
Actual Value Memory
196
-
Actual Values of the System
197
-
Error Protocol
199
-
Error List Description
199
-
Error Messages
199
-
Error Environment
201
-
Operational and Error Diagnosis
203
-
Status Display
203
-
Status of Digital Signals
203
-
Controller Status
204
-
Warning Status
205
-
Parameter List
206
-
-
Advertisement
BONFIGLIOLI act 401 Quick Start Manual (96 pages)
Brand: BONFIGLIOLI
|
Category: DC Drives
|
Size: 6.97 MB
Table of Contents
-
Italiano
3
-
Table of Contents
3
-
Installazione Meccanica
4
-
Installazione Elettrica
7
-
Avvertenze EMI
7
-
ACT 201 (a 3,0 Kw) E ACT 401 (a 4,0 Kw)
8
-
ACT 201 (da 4,0 Kw a 9,2 Kw) E ACT 401 (da 5,5 Kw a 15,0 Kw)
8
-
ACT 401 (da 18,5 Kw a 30,0 Kw)
9
-
ACT 401 (da 37,0 Kw a 65,0 Kw)
9
-
ACT 401 (da 75,0 Kw a 132,0 Kw)
10
-
Messa in Servizio con Unità DI Comando KP500
11
-
Morsetti DI Comando
11
-
Funzioni Dei Tasti
12
-
Messa in Servizio Guidata
12
-
Impostazioni Dei Parametri
14
-
Grandezze DI Funzionamento
17
-
Messaggi Dell’unità DI Comando
17
-
Messaggi DI Avviso Ed Errore Durante Il Funzionamento
18
-
Messaggi DI Avviso Ed Errore Durante la Messa in Servizio
19
-
-
English
21
-
Mechanical Installation
22
-
Electrical Installation
25
-
EMC Information
25
-
ACT 201 (4.0 Kw to 9.2 Kw) and ACT 401 (5.5 Kw to 15.0 Kw)
26
-
ACT 201 (up to 3.0 Kw) and ACT 401 (up to 4.0 Kw)
26
-
ACT 401 (18.5 Kw to 30.0 Kw)
27
-
ACT 401 (37.0 Kw to 65.0 Kw)
27
-
ACT 401 (75.0 Kw to 132.0 Kw)
28
-
Commissioning Via the Control Unit KP500
29
-
Control Terminals
29
-
Functions of Keys
30
-
Guided Commissioning
30
-
Parameter Settings
32
-
Actual Values
35
-
Control Unit Messages
35
-
Warning and Error Messages During Operation
36
-
Warning and Error Messages During Guided Commissioning
37
-
-
Deutsch
39
-
Mechanische Installation
40
-
Elektrische Installation
43
-
EMV — Hinweise
43
-
ACT 201 (4,0 Kw bis 9,2 Kw) und ACT 401 (5,5 Kw bis 15,0 Kw)
44
-
ACT 201 (bis 3,0 Kw) und ACT 401 (bis 4,0 Kw)
44
-
ACT 401 (18,5 Kw bis 30,0 Kw)
45
-
ACT 401 (37,0 Kw bis 65,0 Kw)
45
-
ACT 401 (75,0 Kw bis 132,0 Kw)
46
-
Inbetriebnahme mit der Bedieneinheit KP500
47
-
Steuerklemmen
47
-
Geführte Inbetriebnahme
48
-
Tastenfunktionen
48
-
Parametereinstellungen
51
-
Istwerte
54
-
Meldungen der Bedieneinheit
54
-
Warn- und Fehlermeldungen während des Betriebs
55
-
Warn- und Fehlermeldungen während der Inbetriebnahme
56
-
-
Français
59
-
Installation Mécanique
60
-
Avertissements EMI
63
-
Installation Électrique
63
-
ACT 201 (de 4,0 Kw À 9,2 Kw) Et ACT 401 (de 5,5 Kw À 15,0 Kw)
64
-
ACT 201 (À 3,0 Kw) Et ACT 401 (À 4,0 Kw)
64
-
ACT 401 (de 18,5 Kw À 30,0 Kw)
65
-
ACT 401 (de 37,0 Kw À 65,0 Kw)
65
-
ACT 401 (de 75,0 Kw À 132,0 Kw)
66
-
Bornes de Commande
67
-
Mise en Service Avec Unité de Commande KP500
67
-
Fonction des Touches
68
-
Mise en Service Guidée
68
-
Configuration des Paramètres
70
-
Grandeurs de Fonctionnement
73
-
Messages de L’unité de Commande
73
-
Messages D’avertissement Et D’erreur Pendant Le Fonctionnement
74
-
Messages D’avertissement Et D’erreur Pendant la Mise en Service
75
-
-
Español
77
-
Instalación Mecánica
78
-
Advertencias EMI
81
-
Instalación Eléctrica
81
-
ACT 201 (a 3,0 Kw) y ACT 401 (a 4,0 Kw)
82
-
ACT 201 (de 4,0 Kw a 9,2 Kw) y ACT 401 (de 5,5 Kw a 15,0 Kw)
82
-
ACT 401 (de 18,5 a 30,0 Kw)
83
-
ACT 401 (de 37,0 Kw a 65,0 Kw)
83
-
ACT 401 (de 75,0 Kw a 132,0 Kw)
84
-
Bornes de Control
85
-
Puesta en Servicio con Consola de Programación KP500
85
-
Funciones de las Teclas
86
-
Puesta en Servicio Guiada
86
-
Ajustes de Los Parámetros
88
-
Mensajes de la Consola de Programación
91
-
Valores de Funcionamiento
91
-
Mensajes de Aviso y Error Durante el Funcionamiento
92
-
Mensajes de Aviso y Error Durante la Puesta en Servicio
93
-
Advertisement
Related Products
-
BONFIGLIOLI Active ACT 401-05
-
BONFIGLIOLI Active ACT 401-07
-
BONFIGLIOLI Active ACT 401-09
-
BONFIGLIOLI Active ACT 401-11
-
BONFIGLIOLI Active ACT 401-12
-
BONFIGLIOLI Active ACT 401-13
-
BONFIGLIOLI Active ACT 401-21
-
BONFIGLIOLI Active ACT 401-22
-
BONFIGLIOLI Active ACT 401-23
-
BONFIGLIOLI Active ACT 401-25
Bonfiglioli Categories
DC Drives
Engine
Inverter
Industrial Equipment
Controller
More Bonfiglioli Manuals
Рекомендуемые сообщения
-
#1
Всем привет.
Достался такой частотник bonfiglioli act 401 редкий зверь в нашей местности. Нету панели оператора. Его можно программировать через rs 232, но модуль rs232, и модуль rs485 и другие модули, это дополнительные опции, у меня их нет. Но есть разъем в который подключаются все эти модули. Внимание вопрос ! Можно ли в этом разъеме нащупать rs232 ? Или там свой сигнал и он работает преобразуется в том модуле который вставлен?
Поделиться сообщением
Ссылка на сообщение
-
#2
Скорее всего там голый UART и питание. Проследить по дорожкам на какую микросхему идет и глянуть на нее даташит.
Поделиться сообщением
Ссылка на сообщение
-
#3
В 13.09.2021 в 20:44, mitridat сказал:
Можно ли в этом разъеме нащупать rs232 ?
Можно. Но только USART кейлоггером и сниффером. Правда вероятность, что получится очень мала.
Поделиться сообщением
Ссылка на сообщение
-
#4
Хотя если есть программа к нему то тогда просто подключить ПК на прямую без преобразования интерфейсов. Да можно.
Поделиться сообщением
Ссылка на сообщение
-
#5
1 час назад, UVV-1983 сказал:
Можно. Но только USART кейлоггером и сниффером. Правда вероятность, что получится очень мала.
Проще тогда найти платку с интерфейсом.
В общем понял что задание не мое
Поделиться сообщением
Ссылка на сообщение
-
#6
Тут дело то в чём, в том что есть программа на компьютере которая обменивается какой то информацией с приводом. Этот обмен состоит из каких то определённых пакетов сложенных возможно из восьми или шестнадцати битных чисел. Пакеты из этих чисел могут быть разной длены и состоять не только из полезной информации но и иметь расчёт CRC контрольной суммы либо CRC8 или CRC16 и эта сумма тоже привязывается к пакету. Мало того может быть диалоговая схема общения. Скажу так если у вас есть такая программа то можно подключиться без преобразователя.
Поделиться сообщением
Ссылка на сообщение
Для публикации сообщений создайте учётную запись или авторизуйтесь
Вы должны быть пользователем, чтобы оставить комментарий
Войти
Уже есть аккаунт? Войти в систему.
Войти
-
Последние посетители
0 пользователей онлайн
Ни одного зарегистрированного пользователя не просматривает данную страницу
|
|
Ремонт частотного преобразователя BONFIGLIOLI, впрочем, как и ремонт частотников других производителей имеет ряд особенностей в силу своего конструктива. Частотные преобразователи, точнее их начинка делятся на две части:
- Аппаратная часть,
- Программная часть.
Частотники данного производителя не являются исключением из правил, именно поэтому ремонт частотного преобразователя BONFIGLIOLI имеет точно такой же ряд особенностей, как и у других преобразователей.
Диагностировать ту или иную неисправность помогают коды ошибок частотного преобразователя, которые отображаются на небольшом дисплее, расположенном на лицевой панели привода. Коды ошибок частотного преобразователя BONFIGLIOLI в зависимости от серии описаны в инструкции, пользователя которые можно скачать с нашего сайта.
Ремонт частотных преобразователей BONFIGLIOLI, как и любых других преобразователей, выпущенных под другими брендами, всегда начинается с аппаратной части, после успешного ремонта аппаратной части наступает очередь программной.
Настройка частотного преобразователя BONFIGLIOLI также прописана в инструкции завода производителя, для каждой серии частотных преобразователей настройка будет индивидуальной, так как каждая линейка преобразователей решает свои собственные задачи, этим обусловливается широкая номенклатура данного промышленного оборудования.
Ремонт частотных преобразователей BONFIGLIOLI в сервисном центре
Компания «Кернел» производит ремонт частотных преобразователей BONFIGLIOLI в с 2002 года. За время существования компании наши сотрудники накопили колоссальный опыт в ремонте преобразователей частоты такого известного производителя как BONFIGLIOLI. Ремонт подобного промышленного оборудования ответственное и сложное занятие, требующие максимальной отдачи, профессионализма и максимально полной материальной базе.
Специалисты нашего сервисного центра максимальное внимание уделяют качеству исполнения ремонта, программирования и настройке промышленных преобразователей частоты, не зависимо от производителя данного промышленного оборудования. Именно поэтому мы смело даем гарантию на все выполненные работы шесть месяцев.
Ремонт частотных преобразователей BONFIGLIOLI в производится исключительно с использованием оригинальных запасных частей, на компонентном уровне с применением высокотехнологичного диагностического оборудования, квалифицированным персоналом с инженерным образованием.
В случае выхода из строя преобразователя частоты на вашем производстве либо появились проблемы с приводом, которые вы не можете решить самостоятельно, мы всегда рады вам помочь. Специалисты нашего сервисного центра в минимальные сроки проведут глубокую диагностику с последующим ремонтом частотного преобразователя BONFIGLIOLI.
Инженеры сервисного центра выполняют качественный ремонт частотных преобразователей BONFIGLIOLI в всех серий, когда-либо выпускаемых компанией.
BONFIGLIOLI ACTIVE Cube |
ACU210-01, ACU210-03, ACU210-05, ACU210-07, ACU210-09, ACU210-11, ACU210-13, ACU210-15, ACU210-18, ACU210-21 |
BONFIGLIOLI ACTIVE Agile |
AGL402-02 1, AGL402-03 1, AGL402-05 1, AGL402-07 1, AGL402-09, AGL402-11 1, AGL402-13 1, AGL402-15 2, AGL402-18 2, AGL402-19 2 |
BONFIGLIOLI ACTIVE ANG |
ANG210-11, ANG210-19, ANG410-09, ANG410-18, ANG410-25, ANG410-37, ANG510-55, ANG510-61, ANG610-53, ANG610-59 |
BONFIGLIOLI ACTIVE Series |
ACT401-05, ACT401-07, ACT401- 09, ACT401- 11, ACT401-12, ACT401- 13, ACT401-15, ACT401-22, ACT401-25, ACT401-33 |
BONFIGLIOLI LMD |
LMD037-Y1 1, LMD037-Y2 1, LMD037-D1 1, LMD037-D2 1, LMD075-Y1 1, LMD075-D2 1, LMD150-Y1 1, LMD300-D1 1 |
BONFIGLIOLI VCB |
VCB400-010, VCB400-014, VCB400-018, VCB400-025, VCB400-034, VCB400-045, VCB400-060, VCB400-075, VCB400-115, VCB400-180 |
BONFIGLIOLI SYNTHESIS |
SYN10 S 220 01 AF, SYN10 S 220 07 AF, SYN10 S 220 09 AF, SYN10 T 400 05 AF, SYN10 T 400 07 AF, SYN10 T 400 09 AF |
BONFIGLIOLI SYNPLUS |
SPL200-03F, SPL200-07F, SPL200-11F, SPL200-13F, SPL400-11F, SPL400-13F, SPL400-17F, SPL400-19F, SPL400-21F, SPL400-23F |
BONFIGLIOLI S2U standard |
S2U230S-02 (1), S2U230S-03 (1), S2U230S-07 (1), S2U230S-11 (2), S2U230S-13 (2) |
BONFIGLIOLI S2U IP66 |
S2U230S-07 F IP66 (1), S2U230S-13 F IP66 (2), S2U400T-07 F IP66 (1), S2U400T-18 F IP66 (2), S2U400T-21 F IP66 (3), S2U400T-25 IP66 (3) |
BONFIGLIOLI AEC |
AEC401-19, AEC401-22, AEC401-25, AEC401-29, AEC401-33, AEC401-37, AEC401-43, AEC401-45, AEC401-47, AEC401-49 |
В данной таблице присутствуют далеко не все частотные преобразователи и сервопривода BONFIGLIOLI ремонт которых предлагает наш сервисный центр.
Настройка частотного преобразователя BONFIGLIOLI, программирование
Настройка частотных преобразователей BONFIGLIOLI (программирование) происходит в рамках установленных производителем правил, существует общий алгоритм по программированию (настройке частотных преобразователей), относящийся ко всем производителям данного промышленного оборудования. Ниже представлена пошаговая инструкция по настройке частотных преобразователей BONFIGLIOLI.
- Выбор режима управления приводом BONFIGLIOLI (управление по показанию датчиков, дистанционное управление, дистанционное управление).
- В случае использования отдельного (выносного) монитора, настраивается вывод на него технической информации.
- Далее определяем конфигурацию подключения серводвигателя. На данной стадии задаются такие параметры как- возможность применения обратной связи либо без ее применения, а в память блока заносятся данные по: величине крутящего момента, мощности потребителей, номинальное значения частоты, напряжение, ток и скорости вращения ротора.
- Программируется минимально допустимая величина напряжения и частоты, а также время ускорения ротора от ноля до номинального значения.
- И в завершении, в программу управления частотным преобразователем BONFIGLIOLI вносятся функциональные данные со значениями отдельных клемм и особенностями сигналов. Отмечаются действия оборудования, выполняющиеся автоматически при отсутствии информации поступающей в оперативном режиме с датчика.
В некоторых частотниках существует пункт наличия/отсутствия фильтра в цепи питания двигателя. Этот пункт отвечает за подключение различных видов нагрузок, в том случае, когда возможно выбрать нормальное или инверсное изменение частоты при повышении уровня сигнала обратной связи.
Все настройки частотных преобразователей BONFIGLIOLI приведены в технической документации ниже в удобном формате (PDF) который можно скачать на свой компьютер, распечатать или просто открыть на нашем сайте.
Коды ошибок частотного преобразователя BONFIGLIOLI Synplus
В процессе работы выходит из строя даже самое надежное промышленное оборудование. В данной статье мы приведем ошибки частотного преобразователя BONFIGLIOLI, а точнее BONFIGLIOLI Synplus. Частотники в наше время нашли широкое применения в абсолютно всех сферах промышленности управляя как мини моторами в оргтехнике, так и гигантскими двигателями в горнодобывающей промышленности.
Для простоты общения со столь сложной электроникой все частотные преобразователи оснащены небольшими дисплеями с помощью которых выводятся информационные сообщения с кодами ошибок, расшифровав которые можно сразу же узнать причину ее возникновения. Если учесть распространенность данной промышленной электроники, то появляется острая нужда в расшифровке кодов ошибок частотных преобразователей. В этой статье мы рассмотрим одного из самых известных производителей промышленной электроники имеющему уважение во всем мире, BONFIGLIOLI.
Существует несколько видов ошибок, некоторые из них можно устранить автоматически, а некоторые возможно исправить только, обратившись в специализированный сервисный центр. В таблицах ниже приведены коды ошибок частотного преобразователя BONFIGLIOLI и их расшифровка.
Ошибки частотного преобразователя BONFIGLIOLI Synplus которые невозможно сбросить вручную.
Код ошибки |
Ошибка |
Причина |
Устранение |
CPF |
Программная ошибка |
Влияние внешних помех |
Установите параллельно катушке магнитного контактора, который вызывает помехи, RC импульсный поглотитель |
EPR |
Ошибка EEPROM |
Дефект внутренней памяти EEPROM преобразователя |
Заменить EEPROM |
0V |
В состоянии останова напряжение слишком велико |
Повреждение внутренней измерительной цепи |
Вернуть частотный преобразователь для ремонта |
LV |
В состоянии останова напряжение слишком мало |
|
|
OH |
В состоянии останова частотный преобразователь перегревается |
|
|
CTER |
Токовый датчик сигнализирует ошибку |
Ошибка токового датчика или повреждение внутренней цепи |
Вернуть частотный преобразователь для ремонта |
Ошибки частотного преобразователя BONFIGLIOLI Synplus которые можно сбросить вручную или автоматически.
Код ошибки |
Ошибка |
Причина |
Устранение |
OC-S |
Перегрузка по току при старте |
|
|
OC-D |
Перегрузка по току при замедлении |
1. Установленное время замедления слишком маленькое |
Установите большее время замедления |
OC-A |
Перегрузка по току при разгоне |
|
|
OC-C |
Перегрузка по току при фиксированной скорости |
|
|
OV-C |
Слишком высокое напряжение при работе/ замедлении |
|
|
OVSP |
Превышение скорости при работе |
|
|
Err4 |
Внезапная остановка работы ЦПУ |
Влияние помех извне |
Вернуть частотный преобразователь для ремонта, если данная ошибка часто повторяется. |
Ошибки частотного преобразователя BONFIGLIOLI Synplus которые возможно сбросить вручную.
Код ошибки |
Ошибка |
Причина |
Устранение |
OC |
Перегруз по току в состоянии останова |
|
|
OL1 |
Перегрузка двигателя |
|
|
OL2 |
Перегрузка частотного преобразователя |
Тяжелая нагрузка |
Увеличьте мощность частотного преобразователя |
OL3 |
Перегрузка по моменту |
|
|
LV-C |
Слишком низкое напряжение при работе |
|
|
OH-C |
При работе температура радиатора слишком высокая |
|
|
Преобразователь частоты разработан таким образом, что он пытается избежать аварийных отключений путем ограничения момента, перенапряжения и т.п. Появление сбоев при вводе в эксплуатацию или вскоре после него обычно свидетельствует о неверной настройке или неправильном подключении. Возникновение неисправностей или проблем после длительного режима бесперебойной работы обычно происходит по причине изменений в системе или ее окружении (например, в результате износа).
Полный список всех возможных ошибок частотных преобразователей BONFIGLIOLI можно посмотреть и скачать в файлах ниже.
Частотный преобразователь BONFIGLIOLI, скачать инструкции по эксплуатации
Ниже вы можете скачать руководства по эксплуатации частотных преобразователей BONFIGLIOLI
Частотный преобразователь BONFIGLIOLI LMD инструкция |
Поделиться сообщениемСсылка на сообщение
Скорее всего там голый UART и питание. Проследить по дорожкам на какую микросхему идет и глянуть на нее даташит. Поделиться сообщениемСсылка на сообщение
Можно. Но только USART кейлоггером и сниффером. Правда вероятность, что получится очень мала. Поделиться сообщениемСсылка на сообщение
Хотя если есть программа к нему то тогда просто подключить ПК на прямую без преобразования интерфейсов. Да можно. Поделиться сообщениемСсылка на сообщение
Проще тогда найти платку с интерфейсом. В общем понял что задание не мое Поделиться сообщениемСсылка на сообщение
Тут дело то в чём, в том что есть программа на компьютере которая обменивается какой то информацией с приводом. Этот обмен состоит из каких то определённых пакетов сложенных возможно из восьми или шестнадцати битных чисел. Пакеты из этих чисел могут быть разной длены и состоять не только из полезной информации но и иметь расчёт CRC контрольной суммы либо CRC8 или CRC16 и эта сумма тоже привязывается к пакету. Мало того может быть диалоговая схема общения. Скажу так если у вас есть такая программа то можно подключиться без преобразователя. Поделиться сообщениемСсылка на сообщениеДля публикации сообщений создайте учётную запись или авторизуйтесьВы должны быть пользователем, чтобы оставить комментарий ВойтиУже есть аккаунт? Войти в систему. Войти
Ремонт частотного преобразователя BONFIGLIOLI, впрочем, как и ремонт частотников других производителей имеет ряд особенностей в силу своего конструктива. Частотные преобразователи, точнее их начинка делятся на две части:
Частотники данного производителя не являются исключением из правил, именно поэтому ремонт частотного преобразователя BONFIGLIOLI имеет точно такой же ряд особенностей, как и у других преобразователей. Диагностировать ту или иную неисправность помогают коды ошибок частотного преобразователя, которые отображаются на небольшом дисплее, расположенном на лицевой панели привода. Коды ошибок частотного преобразователя BONFIGLIOLI в зависимости от серии описаны в инструкции, пользователя которые можно скачать с нашего сайта. Ремонт частотных преобразователей BONFIGLIOLI, как и любых других преобразователей, выпущенных под другими брендами, всегда начинается с аппаратной части, после успешного ремонта аппаратной части наступает очередь программной. Настройка частотного преобразователя BONFIGLIOLI также прописана в инструкции завода производителя, для каждой серии частотных преобразователей настройка будет индивидуальной, так как каждая линейка преобразователей решает свои собственные задачи, этим обусловливается широкая номенклатура данного промышленного оборудования. Ремонт частотных преобразователей BONFIGLIOLI в сервисном центреКомпания «Кернел» производит ремонт частотных преобразователей BONFIGLIOLI в с 2002 года. За время существования компании наши сотрудники накопили колоссальный опыт в ремонте преобразователей частоты такого известного производителя как BONFIGLIOLI. Ремонт подобного промышленного оборудования ответственное и сложное занятие, требующие максимальной отдачи, профессионализма и максимально полной материальной базе. Специалисты нашего сервисного центра максимальное внимание уделяют качеству исполнения ремонта, программирования и настройке промышленных преобразователей частоты, не зависимо от производителя данного промышленного оборудования. Именно поэтому мы смело даем гарантию на все выполненные работы шесть месяцев. Ремонт частотных преобразователей BONFIGLIOLI в производится исключительно с использованием оригинальных запасных частей, на компонентном уровне с применением высокотехнологичного диагностического оборудования, квалифицированным персоналом с инженерным образованием. В случае выхода из строя преобразователя частоты на вашем производстве либо появились проблемы с приводом, которые вы не можете решить самостоятельно, мы всегда рады вам помочь. Специалисты нашего сервисного центра в минимальные сроки проведут глубокую диагностику с последующим ремонтом частотного преобразователя BONFIGLIOLI. Инженеры сервисного центра выполняют качественный ремонт частотных преобразователей BONFIGLIOLI в всех серий, когда-либо выпускаемых компанией.
В данной таблице присутствуют далеко не все частотные преобразователи и сервопривода BONFIGLIOLI ремонт которых предлагает наш сервисный центр. Настройка частотного преобразователя BONFIGLIOLI, программированиеНастройка частотных преобразователей BONFIGLIOLI (программирование) происходит в рамках установленных производителем правил, существует общий алгоритм по программированию (настройке частотных преобразователей), относящийся ко всем производителям данного промышленного оборудования. Ниже представлена пошаговая инструкция по настройке частотных преобразователей BONFIGLIOLI.
В некоторых частотниках существует пункт наличия/отсутствия фильтра в цепи питания двигателя. Этот пункт отвечает за подключение различных видов нагрузок, в том случае, когда возможно выбрать нормальное или инверсное изменение частоты при повышении уровня сигнала обратной связи. Все настройки частотных преобразователей BONFIGLIOLI приведены в технической документации ниже в удобном формате (PDF) который можно скачать на свой компьютер, распечатать или просто открыть на нашем сайте. Коды ошибок частотного преобразователя BONFIGLIOLI SynplusВ процессе работы выходит из строя даже самое надежное промышленное оборудование. В данной статье мы приведем ошибки частотного преобразователя BONFIGLIOLI, а точнее BONFIGLIOLI Synplus. Частотники в наше время нашли широкое применения в абсолютно всех сферах промышленности управляя как мини моторами в оргтехнике, так и гигантскими двигателями в горнодобывающей промышленности. Для простоты общения со столь сложной электроникой все частотные преобразователи оснащены небольшими дисплеями с помощью которых выводятся информационные сообщения с кодами ошибок, расшифровав которые можно сразу же узнать причину ее возникновения. Если учесть распространенность данной промышленной электроники, то появляется острая нужда в расшифровке кодов ошибок частотных преобразователей. В этой статье мы рассмотрим одного из самых известных производителей промышленной электроники имеющему уважение во всем мире, BONFIGLIOLI. Существует несколько видов ошибок, некоторые из них можно устранить автоматически, а некоторые возможно исправить только, обратившись в специализированный сервисный центр. В таблицах ниже приведены коды ошибок частотного преобразователя BONFIGLIOLI и их расшифровка. Ошибки частотного преобразователя BONFIGLIOLI Synplus которые невозможно сбросить вручную.
Ошибки частотного преобразователя BONFIGLIOLI Synplus которые можно сбросить вручную или автоматически.
Ошибки частотного преобразователя BONFIGLIOLI Synplus которые возможно сбросить вручную.
Преобразователь частоты разработан таким образом, что он пытается избежать аварийных отключений путем ограничения момента, перенапряжения и т.п. Появление сбоев при вводе в эксплуатацию или вскоре после него обычно свидетельствует о неверной настройке или неправильном подключении. Возникновение неисправностей или проблем после длительного режима бесперебойной работы обычно происходит по причине изменений в системе или ее окружении (например, в результате износа). Полный список всех возможных ошибок частотных преобразователей BONFIGLIOLI можно посмотреть и скачать в файлах ниже. Частотный преобразователь BONFIGLIOLI, скачать инструкции по эксплуатацииНиже вы можете скачать руководства по эксплуатации частотных преобразователей BONFIGLIOLI
Сброс ошибок частотных преобразователей BONFIGLIOLIКомпания «Кернел» производит ремонт промышленной электроники и оборудования с 2002 года. За это время мы накопили колоссальный опыт в том числе опыт в ремонте частотных преобразователей BONFIGLIOLI. Ремонт подобной промышленной электроники ответственное и сложное занятие, требующие максимальной отдачи, профессионализма и максимально полной материальной базе. Специалисты нашего сервисного центра уделяют максимальное внимание к качеству исполнения ремонта, программирования и настройке промышленного преобразователя частоты, не зависимо от производителя данного промышленного оборудования. Именно поэтому мы смело даем гарантию на все выполненные работы шесть месяцев. Ремонт частотных преобразователей производится исключительно с использованием оригинальных запасных частей, на компонентном уровне с применением высокотехнологичного оборудования, квалифицированным персоналом с инженерным образованием. Если на вашем производстве появились проблемы с частотным преобразователем, которые вы не можете решить самостоятельно, мы всегда рады вам помочь. Обращайтесь в сервисный центр «Кернел». Специалисты нашей компании в минимальные сроки проведут глубокую диагностику и последующий ремонт частотного преобразователя. Оставьте заказ на ремонт оборудования используя форму на сайте, либо свяжетесь с нашими менеджерами, сделать это очень просто. Схемы подключения частотного преобразователя BONFIGLIOLIСхемы подключений частотных преобразователей BONFIGLIOLI могут отличатся друг от друга даже если эти преобразователи относятся ко одной линейке. Схема подключения преобразователя зависит от многих факторов таких как потребляемая частотным преобразователем нагрузка или питающая сеть к которой подключается частотник 200V – 380V и конечно же зависит от CPU в паре, с которым предполагается работа преобразователя. Ниже приведены схемы подключения частотных преобразователей BONFIGLIOLI:
Оставьте заявку на ремонт промышленного оборудования используя форму на сайте, либо свяжетесь с нашими менеджерами, сделать это очень просто. Оставить заявку на ремонт частотных преобразователей BONFIGLIOLIУ вас вышел из строя частотник? Вам необходим срочный ремонт частотных преобразователей BONFIGLIOLI в ? Оставьте заявку на ремонт нажав на одноименную кнопку в верхней правой части экрана либо свяжитесь с нашими менеджерами. Связаться с ними можно несколькими способами:
Далеко не полный список производителей промышленной электроники и оборудования, ремонтируемой в нашей компании. Диапазон мощности,кВТ: (ACT401) 0.55…132 кВт, 3-х фазное напряжение 320…528 В Тип управления: Различные методы векторного управления: простое/сложное векторное управление с датчиком/без датчика обратной связи Перегрузочная способность: 150% на 60 сек, 200% на 1с Электромагнитный фильтр: Встроенный до 9,2 кВт (EN61800-3) Основные характеристики:
Модули расширения: Увеличение количества аналоговых, цифровых входов и выходов Системная шина, подключение энкодеров различнных типов Модули обмена данными: RS 232, RS 485, Profibus-DP, CANopen Клавиатура: Съемная клавиатура КР500 с функцией копирования параметров Основные характеристики программного обеспечения:
|