Brain bee clima 9000 multigas инструкция

Brain Bee 9000 Bus Plus User And Maintenance Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

9000 BUS PLUS

Mod. 9000 BUS PLUS

Service station for air conditioning systems of vehicles

with refrigerant gas R-134a.

User and maintenance manual

Ver. 1.0

loading

Summary of Contents for Brain Bee 9000 Bus Plus

  • Page 1
    9000 BUS PLUS Mod. 9000 BUS PLUS Service station for air conditioning systems of vehicles with refrigerant gas R-134a. User and maintenance manual Ver. 1.0…
  • Page 2
    9000 BUS Page intentionally left blank ENGLISH 2 / 73 CAP. 1 — CONTENTS…
  • Page 3: Table Of Contents

    5.13.1 AGRI&WORK FUNCTION (OPTION )………….31 CAP. 6 — TECHNICAL FEATURES ………………32 CAP. 7 — INSTALLATION………………..34 EQUIPMENT INSTALLATION………………34 7.1.1 Unpacking 9000 BUS PLUS …………….34 CAP. 8 — COMMISSIONING ………………..36 CONNECTIONS ………………….36 ………………36 OSITIONING AND CONNECTION FIRST TANK FILLING …………………37 NEW OIL BOTTLE FILLING ………………..38 TRACER BOTTLE FILLING ………………..38…

  • Page 4
    9000 BUS 10.1 REMARKS ……………………42 10.2 NON-CONDENSABLE GAS DISCHARGE…………..43 10.3 QUICK MODE AND ZERO TOLERANCE RECHARGE MODE……..44 CAP. 11 — AUTOMATIC CYCLES ………………45 11.1 AUTOMATIC A/C SYSTEM SERVICE …………….45 11.2 AUTOMATIC CYCLE (BUSES) ……………….45 11.2.1 Last cycle …………………45 11.2.2 User-defined cycles………………45 11.3 AUTOMATIC CYCLE (OTHER VEHICLES)…………..45 11.4…
  • Page 5: Cap. 2 — General Instructions

    It may be printed out solely for use by the user and operators of the equipment to which it refers. BRAIN BEE SPA and its staff (authors of the manual) are not liable for any consequences of improper use of the manual or equipment, and guarantees that the information given in the manual has been thoroughly verified.

  • Page 6: Warranty

    The warranty is void in all cases of improper use and failure to run the scheduled maintenance detailed in the manual. Brain Bee S.p.A. accepts no responsibility for any damage deriving from the non respect of the prescriptions indicated in the instructions and in particular those concerning the tool installation, use and maintenance.

  • Page 7: Technical Service Centers

    9000 BUS PLUS TECHNICAL SERVICE CENTERS A list of authorised Brain Bee service centres for CLIMA stations is available on the website www.brainbee.it 2.5.1 Repairs In case of failures or anomalies, the user can contact directly or through his own regional reseller a Brain Bee S.p.A authorised service centre to get help.

  • Page 8: Cap. 3 — Safety Conditions

    Body or person legally responsible for the equipment. 3.1.2 Personal safety information Brain Bee 9000 BUS PLUS A/C service station is particularly simple and reliable due to its adjustments and functions. When used correctly it presents no hazard for the operator, on condition that he observes the following general safety instructions and that the service station is regularly serviced (incorrect maintenance/use compromise the equipment’s safety).

  • Page 9
    Brain Bee S.p.A. service centre. The service station is equipped with safety switches which stops voltage supply in case of station components opening. Never rely on these protections only.
  • Page 10
    The mixture with other types of refrigerant produces serious damages to the conditioning and cooling systems. Mixed gases have to be disposed of according to the current regulations. Do not use the 9000 BUS PLUS station with compressed air systems.
  • Page 11
    A/C service station maintenance can be carried out exclusively by a trained operator or by a service man of a Brain Bee certified seller. If the maintenance is not performed according to the expected schedule, the tool will be blocked.
  • Page 12
    9000 BUS PLUS STOP FOR LONG PERIOD: Store the equipment in a safe place, disconnected from the mains, away from excessive temperatures, humidity and the risk of damaging impact. Contact the Technical Service to run a safety shutdown of the equipment, and if scrapping the unit, to drain and recycle the R134a gas as required by local legislation.
  • Page 13: Important Service Equipment Safety Information

    The equipment contains parts which can cause electrocution: shut off power to the equipment before servicing/repairing it. SAFETY DEVICES 9000 BUS PLUS is equipped with the following safety devices: SAFETY PRESSURE SWITCH: It stops the compressor in case of excessive pressure.

  • Page 14: Cap. 4 — Layout And Use Of The Manual

    9000 BUS PLUS CAP. 4 — LAYOUT AND USE OF THE MANUAL USE OF THE MANUAL This manual is an integral part of the equipment and must be kept in the equipment’s immediate vicinity by the purchaser • If the equipment is sold on to a new user, this manual must accompany it.

  • Page 15: Glossary

    The following refrigerant fluids may be used: o R-134a C2H2F4 — 1,1,1,2-Tetrafluoroethane A/C system: Motor vehicle air conditioning system. Equipment: 9000 BUS PLUS service station for recovery, recycling, vacuum, charge of A/C system. External tank: Refrigerant bottle used to fill the internal tank.

  • Page 16: Guidelines For Handling Refrigerant

    9000 BUS PLUS GUIDELINES FOR HANDLING REFRIGERANT 4.4.1 Precautions for refrigerant storage The refrigerant removed from the A/C system must be handled with care to prevent or minimise the risk of mixing with other refrigerants. The external canisters used to store the refrigerants must be clearly marked to prevent mixing different refrigerants.

  • Page 17: Cap. 5 — General Description

    9000 BUS PLUS CAP. 5 — GENERAL DESCRIPTION The advanced technology and innovative concept employed in designing and fabricating the 9000BUS PLUS makes it extremely simple and reliable in operation. With its vessel holding up to 32 kg of refrigerant, 9000BUS PLUS has been specifically designed for the maintenance and service of vehicle A/C systems containing large amounts of refrigerant, particularly buses.

  • Page 18: Front View (Exterior)

    9000 BUS PLUS FRONT VIEW (EXTERIOR) 1. New PAG oil container 1000 cc 2. Exhausted oil container 1000 cc 3. UV contrast fluid container 250 cc 4. Handles ONLY MAINTENANCE TECHNICIANS MAY REMOVE THE FRONT AND REAR DOORS OR THE TOP COVER CAP.

  • Page 19: Front View (Interior)

    9000 BUS PLUS FRONT VIEW (INTERIOR) 5. Vacuum pump 6. Refrigerant tank 40 L 7. Load cell 8. Non-condensable gas vent valve (automatic) ONLY MAINTENANCE TECHNICIANS MAY REMOVE THE FRONT AND REAR DOORS OR THE TOP COVER ENGLISH 19 / 73…

  • Page 20: Rear View (Exterior)

    9000 BUS PLUS REAR VIEW (EXTERIOR) 9. Caster wheels, with brakes 10. Handling wheels 11. Rear door ONLY MAINTENANCE TECHNICIANS MAY REMOVE THE FRONT AND REAR DOORS OR THE TOP COVER CAP. 5 — GENERAL DESCRIPTION 20 / 73 ENGLISH…

  • Page 21: Rear View (Interior)

    9000 BUS PLUS REAR VIEW (INTERIOR) 12. Manifold 13. Distiller 14. Dryer filter 15. Safety pressure switch 16. Oil separator 17. Compressor ONLY MAINTENANCE TECHNICIANS MAY REMOVE THE FRONT AND REAR DOORS OR THE TOP COVER ENGLISH 21 / 73…

  • Page 22: Right Side View

    9000 BUS PLUS RIGHT SIDE VIEW 18. HP hose and quick coupling 19. LP hose and quick coupling DO NOT USE THE UNIT UNLESS THE CHARGING HOSES (HP – LP) ARE CORRECTLY CONNECTED CAP. 5 — GENERAL DESCRIPTION 22 / 73…

  • Page 23: Left Side View

    9000 BUS PLUS LEFT SIDE VIEW 20. Main switch with 230 VAC MAINS SUPPLY FUSES (5×20 T 10A 250V) 21. USB type-B for direct connection to PC. 22. USB type-A for connection to USB 2.0 key or refrigerant identifier (optional) 23.

  • Page 24: Front Side View

    9000 BUS PLUS FRONT SIDE VIEW 24. Touch Screen graphic display 25. LP Gauge 26. HP gauge CAP. 5 — GENERAL DESCRIPTION 24 / 73 ENGLISH…

  • Page 25: Touchscreen

    9000 BUS PLUS TOUCHSCREEN All settings, controls and service functions are available on the touchscreen display. It also displays the service equipment’s status, the progress of A/C system service and any alarms and error messages. The touchscreen is the basic operator interface and can be operated with the fingers or some other object, such as a pen.

  • Page 26: Status Bar

    9000 BUS PLUS If you need to enter free text or identify a set of data, a keypad automatically appears (for example, for entering workshop data or at the end of the service cycle). Press for symbols STATUS BAR The status bar is in the upper part of the screen. When the unit is switched on, the vessel pressure (brown) is shown on the left and the residual gas weight in the vessel (green) on the right.

  • Page 27
    9000 BUS PLUS The following status bars are available. BROWN status bar • indicates the pressure level inside the vessel (value expressed in Bar). GREEN status bar • indicates the amount of refrigerant inside the vessel (value expressed in Kg).
  • Page 28: Function Keys

    9000 BUS PLUS 5.10 FUNCTION KEYS 9000 BUS PLUS has the following function keys By pressing this key for at least 2 seconds, the refrigerant amount to be charged inside the vehicle A/C system may be modified. Once the value has Refrigerant been changed, press the icon again to quit.

  • Page 29
    9000 BUS PLUS By pressing this key for at least 2 seconds, data relating to the selected vehicle may be read, if the vehicle is included in the Autodata database. Info By pressing this key for at least 2 seconds, the A/C system composition of the selected vehicle may be displayed, if the vehicle is included in the Autodata database.
  • Page 30: Eco Lock® Quick Couplers

    9000 BUS PLUS 5.11 ECO LOCK® QUICK COUPLERS ECO LOCK® is the INTELLIGENT COUPLER, Brain Bee patented, that with the suitable automated procedure in the software enables to: 1. reduce the non condensable gas formation inside the vessel ; 2. avoid the refrigerant dispersion in the air during the disconnection (puff effect);…

  • Page 31: Agri&Work Function (Option )

    9000 BUS PLUS • Degreasing detergent, to remove fluorescent tracer residues (Spray multinet) • Degreasing detergent for condenser (Condenser cleaner) • Flushing kit • Car A/C system sanitary spray • Cabin sanitary agent spray • Management software for A/C stations (Clima Solutions) that allows the data transfer from the CLIMA appliance to the management software for A4 report printing and annual balance management for gas charge/discharge (ref.

  • Page 32: Cap. 6 — Technical Features

    9000 BUS PLUS CAP. 6 — TECHNICAL FEATURES Vessels for R134a fluids Capacity 40 l Maximum operating pressure (PS) 20 bar PED category (Dir.97/23/EC) Weight of gas content Scale Maximum weight of gas content in the vessel 32 kg Safety valve…

  • Page 33
    9000 BUS PLUS 1 g resolution, ± 5 g accuracy with mechanical overload protection UV tracer automatic injection Timed Flushing With integrated solenoid valves and external accessory equipment System pressure diagnostics Manual and automatic (cars and industrial vehicles only) Database…
  • Page 34: Cap. 7 — Installation

    CAP. 7 — INSTALLATION EQUIPMENT INSTALLATION 7.1.1 Unpacking 9000 BUS PLUS RISK OF OVERTURNING The manufacturer disclaims all responsibility for damage to objects and/or persons resulting from the equipment being wrongly removed from the pallet, or from the operation being made by unsuitable personnel, with improper means/protections and without complying with the existing laws on manual handling of loads and with the operations described in this manual.

  • Page 35
    Keep the pallet, carton and scratch protection film for use when returning the unit. The unit rolls on wheels; the two smaller wheels can be locked. 9000 BUS PLUS is supplied with the accumulation tank empty. This prevents problems in shipping the unit.
  • Page 36: Cap. 8 — Commissioning

    9000 BUS PLUS CAP. 8 — COMMISSIONING CONNECTIONS The unit has to be positioned on a horizontal surface to ensure the correct operation. The unit has to be connected to the electric mains following instructions on the identification plate of the unit applied next to the main switch, mainly as to applicable voltage and power.

  • Page 37: First Tank Filling

    9000 BUS PLUS FIRST TANK FILLING Execute the following actions in sequence by following the display guided procedure and the illustrations on the summary sheet provided with the equipment: • Gas weight check • Oil weight check • Pressure check •…

  • Page 38: New Oil Bottle Filling

    9000 BUS PLUS NEW OIL BOTTLE FILLING The new oil bottle is on the left – looking at the unit from the front side. To fill it, it has to be extracted from its housing by means of the quick coupler on the top of the bottle;…

  • Page 39: Cap. 9 — Setup

    9000 BUS PLUS CAP. 9 — SETUP The SETUP menu enables you to set various parameters and switches: HYBRID FUNCTION • by selecting this entry, one may change the type of Oil to inject into the A/C system. Attention: the HYBRID KIT PRO (optional accessory) is required in order to run this function ECO LOCK®…

  • Page 40
    GAS TYPE: • by selecting this entry, you can learn the type of gas the unit is set for, to change the type of gas contact an Authorised Brain Bee Service Centre. CAP. 9 — SETUP 40 / 73 ENGLISH…
  • Page 41
    9000 BUS PLUS DEFAULT SETUP • by selecting this entry, one may reset the unit’s standard settings. Brain Bee reserves the right to add new parameters to make the equipment increasingly versatile and adaptable to market’s needs. ENGLISH 41 / 73…
  • Page 42: Cap. 10 — A/C System Recharge

    9000 BUS PLUS CAP. 10 — A/C SYSTEM RECHARGE 10.1 REMARKS The refrigerant recovery and the new recharge of a car A/C system work better if the car engine is hot. The service station has to be recently switched on in order to enable the possible vent of non condensable gases and complete the initial ventilation phase.

  • Page 43: Non-Condensable Gas Discharge

    9000 BUS PLUS 10.2 NON-CONDENSABLE GAS DISCHARGE The station is equipped with the AIR PURGE SYSTEM function, which allows automatically detecting and purging non-condensable gas (mainly air) accumulated within the tank. Periodically, basically every week, the station, the first time it is switched on that day, will suggest…

  • Page 44: Quick Mode And Zero Tolerance Recharge Mode

    9000 BUS PLUS 10.3 QUICK MODE AND ZERO TOLERANCE RECHARGE MODE MULTIGAS 9000 PLUS can apply two different refrigerant recharge modes; the first one is called Quick mode and features the opening of the recharge valve by injecting gas through the HP port.

  • Page 45: Cap. 11 — Automatic Cycles

    11.4 Vehicle selection from database (for Other vehicles only) Brain Bee offers customers purchasing a 9000 BUS PLUS the possibility of enhancing potentials of the UNIT through the Autodata database. (cars and industrial vehicles only). This database contains all data related to the A/C system of most vehicles. Hence, it will be possible to speed up the recharge operations of the system with the aid of the data provided by the database.

  • Page 46: User-Defined Cycles

    9000 BUS PLUS 11.6 User-defined cycles It allows loading the parameters of the automatic cycle previously saved by the user. 11.6.1 Automatic cycle parameters configuration After selecting the type of A/C system the main page is shown with the following preset values: •…

  • Page 47: Oil Type Replacement

    9000 BUS PLUS 11.6.2 OIL TYPE REPLACEMENT In order to set the oil type press several times the present icon until the icon that will be used for the service will appear (you can set only the following 4 types ).

  • Page 48: Cap. 12 — Manual Cycles

    9000 BUS PLUS CAP. 12 — MANUAL CYCLES 12.1 PRELIMINARY OPERATIONS It is necessary to connect both the LP (low pressure) – and HP (high pressure) couplers to the vehicle A/C system (Screw the valves only when required by the A/C station).

  • Page 49: Injection

    9000 BUS PLUS 12.4 INJECTION In the main menu select MANUAL CYCLES and then INJECTION. Set the following items (See Chap. 5.8): amount of refrigerant that will be charged into the system and the amount of refrigerant contained in the inner tank of the UNIT.

  • Page 50: Flushing (With Optional Accessories)

    9000 BUS PLUS 12.5 FLUSHING (with optional accessories) After performing a lot of recharge cycles or after replacing components or parts of the /AC circuit on a vehicle it is advisable to carry out a system flushing. The system washing (Flushing) consists in purifying the vehicle cooling system through several R134a or R1234yf gas flushes, by recovering it each time, so that the impurities can be filtered little by little through the additional filter.

  • Page 51: Emptying Hoses

    9000 BUS PLUS PRESSURE VALUES CHANGE CONSIDERABLY WHEN AMBIENT TEMPERATURE CHANGES. 12.7 EMPTYING HOSES To empty the recharge hoses completely perform the HOSES EMPTYING phase. Select in the menu the HOSES EMPTYING function (for the touch screen use, see table chap. 5.8).

  • Page 52: Cap. 13 — Maintenance

    9000 BUS PLUS CAP. 13 — MAINTENANCE 9000 BUS PLUS is a highly reliable A/C service system with excellent quality parts, manufactured with the most advanced available production techniques. Please contact an authorized technical service centre for all maintenance interventions and to purchase spare parts.

  • Page 53: Self Leak Test

    60 hours of operation. LONG LIFE PUMP is a Brain Bee patented special function allowing to extend even to 1000 hours the life of the pump oil used in the station.

  • Page 54
    (For the touchscreen use, see chap. 5.8) When 9000 BUS PLUS is switched on, if the expiry of the 60-hour period is coming (9 hours before, that is 15 % of the period), a black bar as in the picture below is displayed.
  • Page 55: Filters Replacement

    To increase its autonomy, the station is fitted with a battery of 2 dryer filters. The software will notify when the dryer filer of 9000 BUS PLUS must be replaced (see Chap. 13.3.1).

  • Page 56: Message For Filters Almost Exhausted

    13.4.2 MESSAGE FOR FILTERS ALMOST EXHAUSTED When 9000 BUS PLUS is switched on, if the filterable amount of 150 kg is coming to an end (that is 15 % of the amount) a black bar is displayed as shown below.

  • Page 57: Vessel Filling (A/C Service Station Tank)

    9000 BUS PLUS To access the COUNTERS menu, from the main menu enter the MAINTENANCE menu and press COUNTERS. (For the touchscreen use, see chap. 5.8) COUNTERS display the following information: • Pump activation • Compressor activation • Pump oil remaining time •…

  • Page 58: Non-Condensable Gas Discharge

    This mode guarantees a higher level of the service quality. 13.9 SYSTEM INFORMATION By selecting this function, you can display the identifying codes and the electronic boards software version of the 9000 BUS PLUS station. 13.10 MAINTENANCE OF PRINTER To change the roll of paper follow instructions below: Open the lid of the printer as shown.

  • Page 59: Periodic Checks

    (of commissioning or period requalification) do not establish different frequencies.. The checks must be performed by the bodies in charge of the country where 9000 BUS PLUS is commissioned, in compliance with the national laws/rules and the respective procedures. Please…

  • Page 60
    • If the automatic safety valve trips, contact technical service to have the unit checked over, resolve any problems and replace the valve if necessary. SUCTION UNIT 9000 BUS PLUS Art. 3.3 (Dir. 97/23/EC) • Make sure no corrosion and leakages are present.
  • Page 61
    Periodically check that the external charging hoses, red (HP) and blue (LP), are in good order and undamaged. In case damages to the hoses are detected, stop using 9000 BUS PLUS and contact the technical customer service for the related replacement.
  • Page 62: Cap. 14 — Disposal

    9000 BUS PLUS CAP. 14 — DISPOSAL 14.1 A/C SERVICE UNIT DISPOSAL At the end of its service life, the unit must be disposed of as follows: • Contact the service centre to have the refrigerant in the unit recovered and recycled.

  • Page 63: Cap. 15 — Spare Parts

    • UV tracer • Thermal paper rolls Further spare parts are available through the Service Centres authorised by Brain Bee S.p.A. or by its reseller. WARNING Using non-original / unapproved spare parts or accessories can compromise the safety of 9000 BUS PLUS.

  • Page 64: Cap. 16 — Message And Alarm Codes

    CAP. 16 — MESSAGE AND ALARM CODES Please find below the list of message and alarm codes that could be detected by the 9000BUS PLUS software. If there are alarms, it is advisable to apply to Your supplier or service Partner. Notice/Warning messages are coded with Wxxx code on the title of the window.

  • Page 65
    9000 BUS PLUS CODE MESSAGE When it occurs Possible Actions situations W036 FURTHER OIL During oil Insufficient Increase the vacuum INJECTION NOT injection phase vacuum level phase time, check the POSSIBLE A/C system tightness. W044 VESSEL EMPTY During flushing Gas level is too…
  • Page 66
    9000 BUS PLUS Alarm messages are coded Axxx in the window title bar. Alarms immediately terminate the procedure and prevent its resumption. CODE MESSAGE When it can Possible causes Actions occur A000 EEPROM NOT Electronics EEPROM Replace the logic electronic…
  • Page 67
    9000 BUS PLUS CODE MESSAGE When it can Possible causes Actions occur A033 CIRCUIT LEAKAGE During the Leakage in the Identify the leak position in vacuum, circuit or in the the vehicle or connected vessel filling vehicle fittings. system and have it…
  • Page 68
    9000 BUS PLUS CODE MESSAGE When it can Possible causes Actions occur A037 FURTHER During gas Hoses not Caution: before REFRIGERANT injection phase connected to proceeding, empty out INJECTION NOT vehicle A/C the hoses. POSSIBLE system; tap Repeat the recovery closed;…
  • Page 69
    9000 BUS PLUS CODE MESSAGE When it can Possible causes Actions occur A047 LP LEAKAGE During the At the end of the Empty the vehicle (follow gas recovery gas injection, in the procedure guided by and hoses the Eco-Lock the displayed messages)
  • Page 70: Cap. 17 — Maintenance Forms

    9000 BUS PLUS CAP. 17 — MAINTENANCE FORMS 9000 BUS PLUS Serial Number ………………………………………. MAINTENANCE FORM Vacuum pump oil change Date Maintenance technician identification Maintenance technician signature and stamp CAP. 17 — MAINTENANCE FORMS 70 / 73 ENGLISH…

  • Page 71
    9000 BUS PLUS MAINTENANCE FORM Dryer filter change Date Maintenance technician identification Maintenance technician signature and stamp ENGLISH 71 / 73 CAP. 17 — MAINTENANCE FORMS…
  • Page 72
    9000 BUS PLUS MAINTENANCE FORM Gas receiver load cell check Date Result of check Maintenance technician Maintenance technician (pass/fail) identification signature and stamp CAP. 17 — MAINTENANCE FORMS 72 / 73 ENGLISH…
  • Page 73
    9000 BUS PLUS MAINTENANCE FORM Other checks/maintenance/repairs Date Result of Maintenance Maintenance technician check technician signature and stamp (pass/fail) identification ENGLISH 73 / 73 CAP. 17 — MAINTENANCE FORMS…

Brain Bee Clima 9000 Multigas автомтическая установка для заправки автокондицинеров. 

 Полностью автоматическая установка для заправки и обслуживания систем кондиционерования воздуха. В базовой комплектации поставляется для работы с газом R134a, в будущем возможно переоснащение для работы с газом R1234yf (комплект приобретается отдельно) Установка позволяет выполнять полный цикл обслуживания системы кондиционирования как в автоматическом (имеется встроенная база данных автомобилей), так и в ручном режимах. Оснащена сенсорным дисплеем на русском языке.

Гарантия – 1 год.  Возможность продления – до 3 лет.  

Срок окупаемости установки в сезон – 1-2 недели.

 Особенности установки:

  • Очистка откаченного из авто хладогента  посредством функции MULTIPASS
  • Автоматический подогрев внутреннего баллона  во время вакуумирования
  • Защита,  препятствующая проникновению влаги в емкость с маслом и УФ красителем – Функция OIL CARE
  • Диагностика утечек. Функция UV TRACER, позволяющая производить впрыск УФ красителя  в систему кондиционирования авто.
  • Автоматический воздушный клапан, сбрасывающий скопившиеся неконденсируемые газы из внутреннего баллона. Функция  ускоряет  восстановление хладагента, гарантирует его чистоту в системе автомобиля
  • Работу установки осуществляет  блок  электромагнитных клапанов 

Подробно о CLIMA-9000:

Минимум времени – максимум прибыли

Оборудование для заправки автомобильных кондиционеров CLIMA-9000 – это сочетание стильного дизайна и ультрасовременных высоких технологии. Полная автоматизация всех функций установки  плюс мощное  ПО,   обеспечивают быструю очистку системы кондиционирования, фильтрацию и восстановление хладагента без лишнего вмешательства персонала, который в это время может быть эффективно задействован в других процессах. 

ПО для CLIMA-9000 не вызывает лишних затруднений, оно постоянно совершенствуется, его обновление происходит максимально просто и быстро.

При проектировании установки CLIMA-9000 были приняты во внимание все нюансы расположения внутренних элементов, требующих периодического технического обслуживания. Доступ к ним максимально прост и замена любого компонента не составляет труда.  Все шланги установки оборудованы быстрыми соединениями, нет необходимости открывать корпус установки для их отсоединения.

Цветной сенсорный ЖК дисплей

Управление установкой логичное и элементарное — для выбора любой из операций необходимо сделать всего несколько нажатий на ЖК диплей. Параметры дисплея гарантируют отличную читаемость информации на экране при любом освещении.

Встроенная БД параметров систем кондиционирования автомобилей

База данных CLIMA-9000 содержит самую полную информацию параметров систем кондиционирования всех известных на рынке автомобилей:

  • Позволяет автоматически определить параметры заправки и обслуживания
  • Не имеет срока действия  и может быть обновлена в любое время
  • Возможность внесения в базу ручных настроек неограниченного числа параметров
  • Гарантирует 100% правильность обслуживания каждого автомобиля

Отчеты о работе

Встроенный принтер позволяет делать распечатки для клиентов по выполненным работам.
 

Маневренность и управляемость

Система колес оборудования для заправки автомобильных кондиционеров рассчитана на беспрепятственное перемещение внутри ограниченного пространства по бетонному неровному полу.

Мощность

Мощность вакуумного насоса — 10 м³час, позволяет существенно сократить время выполнения функции закачки хладагента из/в систему кондиционирования автомобиля.

Большое количество заправок

26-литровый баллон для хладагента позволяет выполнить больше чем 100 заправок

Безопасность

Ценность установки так же в ее соответствии самым строгим инструкциям в области безопасности и качества.
CLIMA-9000 соответствует необходимым европейским стандартам относительно электрической, механической и экологической безопасности.

Технические характеристики:

Управление и программное обеспечение

  • Цветной ЖК дисплей 4,3″ 480х272 широкий экран, 65536 цветов
  • Управление — Сенсорный экран
  • Термопринтер
  • Встроенная БД автомобилей
  • Обновление программного обеспечения с помощью —  RS232

Внутренний баллон для хладагента R134a

  • Объем баллона — 26 литров
  • Вместимость  в соответствии директивы PED — 19,6 литров
  • Максимальное рабочее давление соответствует директиве PED – 20 бар
  • Автономный подогрев баллона — Да

Емкости для масла и УФ красителя

  • Емкость для нового масла — 250мл
  • Емкость для отработанного масла — 250мл
  • Емкость для ультрафиолетового красителя — 250мл
  • Точность задания веса масла — ± 1гр.

Прочие характеристики

  • Мощность вакуумного насоса — 6 м³час
  • Минимальный уровень вакуумизации  — 0,05 мбар
  • Рабочий объем компрессора для откачки хладaгента — 14СС
  • Ресурс фильтра осушителя — 45кг
  • Автоматический клапан сброса неконденсируемых газов — Да
  • Электронные краны в магистралях низкого и высокого давлений — Да
  • Длина шлангов высокого и низкого давлений — 4,5 метра
  • Цифровые манометры высокого и низкого давлений  в баллоне — Да
  • Электронные весы — Да
  • Габариты (ШхГхВ) — 641x763x1200 мм
  • Вес — 100 кг
  • Питание — 50 Гц — 220-240 Вольт — 800 Вт

Спрашивайте дополнительно:

  • Flushing kit  Набор для промывки системы кондиционирования.  Позволяет промыть систему кондиционирования автомобиля, произвести её фильтрацию и очистку от инородных механических частиц и влаги.

Доставка и оплата

Доставка по Москве и Московской области осуществляется силами собственного автопарка.
Стоимость доставки внутри МКАД. Рассчитывается индивидуально в зависимости от адреса доставки,
габаритов и веса груза. Минимальная стоимость доставки- 500 рублей.
Стоимость доставки по Московской области. Стоимость доставки по Москве +30руб/км от МКАД до Вашего адреса.
Отправка грузов по РФ. Мы готовы отправить Ваш заказ в любой регион РФ, любой транспортной компанией по Вашему желанию.
Единственное условие- у ТК должна быть погрузочная площадка (офис) в Москве. Доставка до транспортных компаний (при отправке
в регионы РФ)- бесплатно. За доставку в Ваш город Вы оплачиваете непосредственно перевозчику.

Грузы массой свыше 15 кг доставляются до подъезда, либо ворот Вашего предприятия.
Выгрузка товара производится только после оплаты. 
До оплаты Вы можете вскрыть и осмотреть груз, проверить его комплектацию, в кузове автомобиля.

Внимание! После отъезда курьера претензии по внешнему виду, комплектности и количеству товара не принимаются!
Обязательно сохраняйте неповрежденной упаковку товара!

Оплатить товары Вы можете следующими способами:

1. Безналичный расчет. Принимаем безналичные платежи от физических и юридических лиц.
2. Наличный расчет. В офисе нашей компании, либо при доставке курьером по Москве и МО.
3. Банковской картой. Согласно выставленного счета в любом отделении банка. 

Обмен и возвратВо избежание негатива и недопонимания просим Вас внимательно изучить данный пункт перед покупкой товара.

Обращаем Ваше внимание, что после отъезда курьера претензии по количеству товара, механическим повреждениям и комплектации  товара не принимаются.

  Согласно Закону о Правах Потребителей наш интернет-магазин принимает возврат оборудования и инструмента,

приобретенного физическими лицами для личного использования в течении 14 календарных дней с момента приобретения. Оборудование не должно иметь следов эксплуатации, механических повреждений, должны быть сохранены все заводские ярлыки, упаковка в неповрежденном виде.

  Обращаем Ваше внимание, что подавляющее большинство товаров на нашем сайте является технически сложным профессиональным оборудованием, которое не подлежит возврату и обмену по каким-либо причинам, если оно находится в исправном состоянии.

  Также просим Вас учесть, что ЗоПП распространяется только на товары, приобретенные

для собственного применения. То есть на профессиональное оборудование- подъемники, шиномонтажное оборудование, гидравлическое оборудование, специнструмент для автосервиса и т.д., не распространяется, в т.ч. если оно приобретено частным лицом.В отношении юридических лиц и индивидуальных предпринимателей ЗоПП не действует. То есть товары приобретенные на юр.лицо, или ИП возврату и обмену не подлежат.

Если у Вас остались любые вопросы- обратитесь к менеджеру по продажам до приобретения, мы постараемся решить Ваш вопрос в частном порядке.

Автоматическая заправочная станция CLIMA MULTIGAS 9000 Plus – построена на технологии объемного впрыскивания и отвечает требованиям к работе, новый интерфейс со встроенными аналоговыми манометрами.

Лучшая из технологий Brain Bee для максимальной производительности рабочего места.

Применение:

  • предназначена для полного автоматического выполнения работы с хладагентом R134a. (возможность работы с R-1234YF)
  • с новой функцией Agri&Work (опция) может быть интегрирована для сельскохозяйственных и землеройно-транспортных машин

Описание установки CLIMA MULTIGAS 9000 Plus:

Благодаря передовым технологиям дизайна Brain Bee 1234 Technology, Multigas 9000 Plus  может легко преобразован из R-134a в R-1234yf, если потребуется в будущем с помощью специального комплекта (опция 600 EUR), тем самым получая двойную окупаемость первоначальных инвестиций.

  • Все функции, касающиеся технического обслуживания, очистки газа и системы осуществляет на станции мощное программное обеспечение, и не требует присутствие оператора во время осуществления процедуры заправки, что дает право оператору свободно оптимизировать свое время, присутствуя на другом платном ремонте.
  • Электронные датчики давления и клапаны.
  • Сердце 9000 Плюс: интерфейс на LCD дисплее — сенсорный экран отображает все функции,  видимость в любых условиях освещения
  • Air purge system (система очистки газа) — новая автоматическая эксклюзивная функция от Brain Bee (присутствует во всей гамме установок), позволяющая оператору умело удалять из баллона с хладагентом неконденсируемые газы (вместо традиционной ручной операции — по показаниям манометра)
  • Функция Oil Clean. Больше нет отходов — часто препятствующие внешние факторы (например, температура) не позволяют удалить оставшееся в установке масло, что может снизить точность последующей заправки, вызывая потери свежего масла и приводя к неэффективным результатам. Благодаря функции OIL CLEAN («чистота масла»), установка позволяет более эффективно удалить откачиваемое масло в финальной стадии и сохранить газ (обычно используемый при традиционной технологии, чтобы облегчить слив масла).
  • Super Charge («Супер-заправка») — работа установки позволяет получить те же условия, которые могли бы быть созданы при помощи системы подогрева баллона. И результаты при этом значительно лучше при любых климатических условиях, откачка хладагента из автомобиля всегда полна и безупречна. Соответственно для последующей заправки – требуется меньшее время (без каких-либо дополнительных функций), а также экономится электроэнергия.
  • HPV Pump насос. Вакуум вне всякого сравнения — как и в других установках Brain Bee применен HPV Pump (высокопроизводительный вакуумный насос).
  • Long Life Pump (патент) – специальная функция, позволяющая увеличить ресурс работы насоса установки до 1000 часов. Выполняется когда установка не используется, при этом автоматически запускается цикл регенерации (очистки) масла насоса.
  • Разъемы ECO Lock (патент Brain Bee). Данное конструктивное решение позволяет сэкономить хладагент, обеспечивает безопасность оператора и защиту окружающей среды – за счет предотвращения выхода хладагента при отсоединении заправочных шлангов от автомобиля
  • База данных: установки имеют обширную базу данных для R134a, которая может быть обновлена через USB-порт. Автоматически обеспечиваются необходимые параметры заправки для выбранного автомобиля. Все стадии рабочего цикла оптимизированы, максимальная производительность гарантирована.

Технические характеристики:

  • Тип используемого хладагента R134a (R-1234YF)
  • Объем баллона (л) 26
  • Клавиатура — Touch (сенсорная)
  • Принтер — Тепловой, 24-колонки
  • Система защиты давления (bar) 20
  • Минимальное вакуумное давление (m/bar) 0,05
  • Вместимость контейнера для слитого PAG-масла (мл) 250
  • Вместимость контейнера для заливаемого PAG-масла (мл) 250
  • Вместимость контейнера для маркировочной жидкости (мл) 250
  • Производительность вакуумного насоса (м3/час) 10
  • Ресурс фильтра осушителя (кг) 45
  • Длина шлангов высокого и низкого давления (м) 4,5
  • Электропитание (В) 220
  • Потребляемая мощность (Вт) 800
  • Вес (кг) 86

ВАЖНО:

 для работы с газом R-1234YF необходимо приобрести набор для перехода с газа R-134a на R-1234YF — 600 EURO


Технические характеристики

Ввод параметров
автоматический

Объем бака (л)
26

Производительность (л/мин)
160

Тип фреона
R134a, R1234yf

  • BRAIN BEE CLIMA 9000 ENG subtitled

    BRAIN BEE CLIMA 9000 ENG subtitled

  • BRAIN BEE CLIMA 9000 ENG subtitled

    BRAIN BEE CLIMA 9000 ENG subtitled

СПОСОБЫ ДОСТАВКИ

Самовывоз в Москве
Самовывоз в пунктах выдачи заказов СДЭК
Доставка курьером
Доставка транспортными компаниями

СПОСОБЫ ОПЛАТЫ
Оплата наличными 
Безналичный расчет
Перечисление на карту СБ РФ

Полностью автоматическая установка для заправки и обслуживания систем кондиционерования воздуха Brain Bee CLIMA MULTIGAS 9000 Plus. В базовой комплектации поставляется для работы с газом R134a, в будущем возможно переоснащение для работы с газом R1234yf (комплект приобретается отдельно). Установка позволяет выполнять полный цикл обслуживания системы кондиционирования как в автоматическом (имеется встроенная база данных автомобилей), так и в ручном режимах. Оснащена сенсорным дисплеем на русском языке.

Особенности установки:

  • Очистка откаченного из авто хладогента  посредством функции MULTIPASS
  • Автоматический подогрев внутреннего баллона  во время вакуумирования
  • Защита,  препятствующая проникновению влаги в емкость с маслом и УФ красителем – Функция OIL CARE
  • Диагностика утечек. Функция UV TRACER, позволяющая производить впрыск УФ красителя  в систему кондиционирования авто.
  • Автоматический воздушный клапан, сбрасывающий скопившиеся неконденсируемые газы из внутреннего баллона. Функция  ускоряет  восстановление хладагента, гарантирует его чистоту в системе автомобиля
  • Работу установки осуществляет  блок  электромагнитных клапанов

Подробно о CLIMA-9000:

Оборудование для заправки автомобильных кондиционеров CLIMA-9000 – это сочетание стильного дизайна и ультрасовременных высоких технологии. Полная автоматизация всех функций установки  плюс мощное  ПО,   обеспечивают быструю очистку системы кондиционирования, фильтрацию и восстановление хладагента без лишнего вмешательства персонала, который в это время может быть эффективно задействован в других процессах.

ПО для CLIMA-9000 не вызывает лишних затруднений, оно постоянно совершенствуется, его обновление происходит максимально просто и быстро.

При проектировании установки CLIMA-9000 были приняты во внимание все нюансы расположения внутренних элементов, требующих периодического технического обслуживания. Доступ к ним максимально прост и замена любого компонента не составляет труда.  Все шланги установки оборудованы быстрыми соединениями, нет необходимости открывать корпус установки для их отсоединения.

Цветной сенсорный ЖК дисплей

Управление установкой логичное и элементарное ― для выбора любой из операций необходимо сделать всего несколько нажатий на ЖК диплей. Параметры дисплея гарантируют отличную читаемость информации на экране при любом освещении.

Встроенная БД параметров систем кондиционирования автомобилей

База данных CLIMA-9000 содержит самую полную информацию параметров систем кондиционирования всех известных на рынке автомобилей:

  • Позволяет автоматически определить параметры заправки и обслуживания
  • Не имеет срока действия  и может быть обновлена в любое время   
  • Возможность внесения в базу ручных настроек неограниченного числа параметров
  • Гарантирует 100% правильность обслуживания каждого автомобиля

Отчеты о работе

  • Встроенный принтер позволяет делать распечатки для клиентов по выполненным работам.
  • Маневренность и управляемость
  • Система колес рассчитана на беспрепятственное перемещение внутри ограниченного пространства по бетонному неровному полу.

Мощность

Мощность вакуумного насоса ― 6 м³час, позволяет существенно сократить время выполнения функции закачки хладагента из/в систему кондиционирования автомобиля.

Большое количество заправок

26-литровый баллон для хладагента позволяет выполнить больше чем 100 заправок

Безопасность

Ценность установки так же в ее соответствии самым строгим инструкциям в области безопасности и качества.
CLIMA-9000 соответствует необходимым европейским стандартам относительно электрической, механической и экологической безопасности.

  • Производитель: Brain Bee S.p.A.
  • Страна производитель: Италия
  • Тип: Автомат
  • Хладагент: R134A, R1234yf
  • Производительность до, л/мин: 165
  • Мощность, кВт: 0,8
  • Длина шланга со щупом, м: 4,5
  • Сеть, В: 220
  • Наличие дисплея: Да
  • Меню на русском языке: Да
  • Встроенная руссифицированная БД: Да
  • Наличие принтера: Да
  • Наличие весов: Да
  • Точность весов ±, г: 1
  • Объём ёмкости для хладагента, л: 26
  • Рабочая температура мин, °C: -5
  • Рабочая температура макс, °C: +40
  • Применение: Легковой, Грузовой
  • Ширина, мм: 763
  • Длина, мм: 641
  • Высота, мм: 1200
  • Масса, кг: 86
  • Гарантия, мес: 12

Важно! Вещи которые стоит уточнить у менеджера

Цена и наличие – в связи с колебанием курса валют возможны неточности до 10%.

Комплектность и характеристики, т.к. они могут быть изменены заводом изготовителем!     

5 фактов о нашей компании, которые вы могли не знать.

  • Безналичный/наличный расчёт, предоставление документов для вывоза в страны ЕАЭС.
  • Доставка во все регионы России. Возможность поставки Беларусь, Казахстан.
  • Бесплатная доставка до терминала ТК «Деловые линии» и «ПЭК»
  • Отгрузка с 3 – х складов, Москва, Санкт-Петербург, Екатеринбург.
  • Наша площадка является мульти брендовой, мы предоставляем самый большой ассортимент под Ваш запрос! Вы можете сравнить Ваш выбор с аналогами вместе менеджером компании!

Успейте приобрести Установка для заправки автомобильных кондиционеров Brain Bee Clima Multigas 9000 Bus Plus по выгодной цене раньше своих конкурентов! Модель 1010350205XX хорошо зарекомендовала себя на Российском рынке цена-качество! Производитель постарался максимально усовершенствовать выбранный вами товар, обеспечив этим безупречное качество среди конкурентов.

Рохли гидравлические

Впрыск масла
Автоматический

Впрыск УФ краски
Автоматический

Габаритные размеры (ДхШхВ), мм
673 х 738 х 1200

Длина шлангов, м
4,5

Манометры
Стрелочные

Масса, кг
130

Наличие принтера
Да

Объём внутреннего баллона, л
40

Определение утечек
Автоматическое вакуумом

Откачка масла
Электронные весы

Подогрев баллона
Функция Super Charge

Тип установки
Полностью автоматическая

Экран / Ввод данных
Сенсорный дисплей

Характеристика подставки

Производитель
Brain Bee (Италия)

Понравилась статья? Поделить с друзьями:
  • Brahmi churna инструкция по применению порошок
  • Brahmarasayanam инструкция по применению на русском языке
  • Bragman турбо дрожжи инструкция по применению
  • Bragman 48 universal инструкция по применению на русском
  • Brady bmp21 plus инструкция на русском