Частотный преобразователь italtecnica sirio universal инструкция

Italtecnica Sirio Universal Programming Manual

  1. Manuals
  2. Brands
  3. Italtecnica Manuals
  4. Inverter
  5. Sirio UNIVERSAL
  6. Programming manual

  • Bookmarks

Quick Links

Manual de programação

PT

GR

CZ

Návod na programovanie

SK

Programmeerhandleiding

NL

Manual de programare

RO

Rel. 2.0

04/2020

Sirio

Universal

Manuale di programmazione

Programming manual

Manuel de programmation

Programmieranleitung

Manual de programación

IT

EN

F

DE

E

RUS

loading

Related Manuals for Italtecnica Sirio Universal

Summary of Contents for Italtecnica Sirio Universal

  • Page 1
    Sirio Universal Manuale di programmazione Manual de programação Programming manual Manuel de programmation Návod na programovanie Programmieranleitung Programmeerhandleiding Manual de programación Manual de programare Rel. 2.0 04/2020…
  • Page 3
    PROGRAMMING (EN) DESCRIPTION OF THE BUTTONS Left-hand arrow: this scrolls back through the menu pages Right-hand arrow: this scrolls forwards through the menu pages On-Off/Reset: this switches the device from stand-by to operation mode and resets the unit in the event of alarms and/or errors.
  • Page 4
    INSTALLER PARAMETERS: These parameters can be found on hidden pages and usually they should only be changed in the installation phase. To access these pages switch the device to Stand- use the ge the parameters. To return to the main page press the button in the centre.
  • Page 5
    Nominal motor frequency: depending on which motor is used, it is possible to select a maximum nominal Nom.fre. output frequency from the inverter (50 or 60 Hz). Caution: an incorrect selection of the maximum frequency may cause damage to the pump; consult the manufacturer’s technical data carefully. 50 Hz Switching frequency: set the frequency of inverter switching.
  • Page 6
    Input function on the I/O board: choose the function associated to the digital input of the auxiliary I/O board I/O out (available on request). The settable values are: output disabled error: the output is activated (closed contact) in the presence of any error in Sirio pump in operation: the output is activated (contact closed) whenever Sirio controls the pump start-up auxiliary pump: enables control of an auxiliary pump at a set speed which starts up when the pump controlled by Sirio is no longer able to fulfil the needs of the system.
  • Page 7
    ADVANCED PARAMETERS: The advanced parameters are accessible only to the technical assistance service. For access to these parameters, it is necessary to contact the re-seller, a technical assistance centre or the manufacturer. The following table lists the advanced parameters for reference when technical assistance is required. REF.
  • Page 8
    ALARMS In the event of system anomalies or malfunctions, one of the following screens will appear on the Sirio display. Each error is coded with the letter «E» followed by a number from 0 to 13. The number which appears in brackets represents the number of recurrences of each error. To reset an alarm, after having resolved the cause, it is usually sufficient to press the central «reset»…
  • Page 9: Possible Malfunctions

    POSSIBLE MALFUNCTIONS: When one of the taps / outlets in the system is opened, the pump does not start, or there is a few seconds delay before it starts The DeltaP value is set too high or a check valve has been fitted downstream of the device. Try to increase the value of the start-up pressure Pmin and eliminate any valves after the Sirio.

  • Page 10: Maintenance

    MAINTENANCE: The Sirio is designed to keep maintenance requirements at a minimum. To guarantee the device a long working life and perfect functionality, always follow the instructions below: — ensure the device does not have to withstand temperatures of below 3° C; if this is not possible, make sure all the water inside it is drained out to prevent it from freezi — if the pump is equipped with intake filters, carry out regular checks to ensure they are clean;…

SIRIO UNIVERSAL

SIRIO UNIVERSAL XP

SIRIO UNIVERSAL — INTERIOR

TECHNICAL DATA

INSTALLATION WIZARD

POWER SUPPLY CONNECTION

1PH 230V MOTOR CONNECTION

3PH 230V MOTOR CONNECTION

Request information

INVERTER FOR ELECTRIC PUMPS CONTROL

Choose the comfort of constant pressure and the silence of the pump that only an inverter system can offer.

Universal model for electric pumps with single-phase 230V and three-phase 230V motor output.

Easy to install and set. At the initial start-up a wizard allows to choose the electric pump’s type, its power supply and the pressure of the system.

Dry running protection, over pressure protection, protection against leakages and against rotor blocking in one item only.

Applications

PROTECTION AGAINST DRY RUNNING

INVERTER WITH STEADY PRESSURE

PRODUCT DETAILS

Download product informations

RESERVED DOCUMENTS

Download reserved documents

Video

  • Features
  • Accessories
  • Optionals

• It controls the start and stop functions of the traditional electric pump (surface, vertical and submersible) and modulates the motor rotations according to the water request from the system. Hammering is reduced and inrush starting current avoided.
Constant pressure.
• Integrated pressure transducer.
• Possibility to desable the flow sensor if the water is not perfectly clean or ferrous.
Energy saving.
• Protection against dry running.
• Automatic reset in event of dry running.
Protection against leakages, over pressure, over heating, rotor blocking and abnormal power supply.
• Motor over current control.
Digital indication of the pressure, the voltage, the current and the motor frequency.
• Adjustment of the frequency with temperature’s increasing.
Programmable input and output for different functions (enable, double set-point, error, master/slave configuration).
• Multilingual display with 16 characters.
Wi-Fi connection from smartphone (optional)

• I/O expansion card available (1 input + 1 output).
• Cable for connection in twin booster sets 4×0.5 mm 2 100 cm (ACG.CBL.4X05.100).
• Interface module SIRIO X4 (ACG.MD.SRX4.230).
• Power supply protection module (ACG.MD.PROT.230).
• Version for high speed motor pump (90/100/140 Hz).
• Version for IPM motors.
• Advanced parameters accessible by an hidden menu.
• Wi-Fi connection module.

OTHER PRODUCTS


Plumbing Connections

Plumbing Connections

• Plastic plumbing connection with up to 10 bar guaranteed tightness
• 1 «or 1» 1/4 straight fitting
• Male or revolving female outlet connection available
• Fitting with 90 ° elbow available
• Quick installation thanks to the revolving connection
• Easy removal of the device from the system for short maintenance
• Internal rubber gasket replacing hemp or teflon, guarantees quick assembly and prevents check valve malfunctions
• Compatible with any control device available on the market
• Lower cost than brass connection
 


NETTUNO THREE-PHASE

NETTUNO THREE-PHASE

Features

Features and materials
QUICK INSTALLATION
ENERGY SAVING
STEADY PRESSURE


NETTUNO UNIVERSAL

NETTUNO UNIVERSAL

Features

Features and materials
QUICK INSTALLATION
ENERGY SAVING
STEADY PRESSURE

UNIPUMP

Частотный преобразователь SIRIO Italtecnica — электронное устройство управления с частотным регулированием. SIRIO подключается к однофазной электросети 230 В, на выходе дает трехфазное напряжение 230 B. Руководство по монтажу и эксплуатации.

Скачать
Pdf 9.21 Mb
Язык: RU

Related Devices:

  • NSM KR 80
  • Italtecnica NETTUNO 3P-13A
  • Italtecnica Brio 2000
  • GRUNDFOS ALLDOS Vaccuperm VGA-117 Series
  • EVE aqua 20EAI4101
  • Burkert 8644 AirLINE
  • Italtecnica Sirio Entry 230
  • GVS K-BUS AMRW-24/10.1

Types of Manuals:

The main types of Italtecnica Sirio UNIVERSAL instructions:

  • User guide — rules of useing and characteristics
  • Service manual — repair, diagnostics, maintenance
  • Operation manual — description of the main functions of equipment

Controller, Inverter Instructions by Italtecnica:


  • CanadianSolar CSI-25KTL-GS-FL

    CANADIAN SOLAR INC. Global Headquarters: $~ CanadianSolar 545 Speedvale Avenue, West Guelph, Ontario N1 K 1 E6, Canada Tel: +1 519 837 1881 Sales Inquiries Email: [email protected] Technical Inquiries Email: [email protected] CANADIAN SOLAR (USA), INC. North America Headquarters: 3000 Oak Road, Ste …

    CSI-25KTL-GS-FL Inverter, 39

  • Goodwe ET Series

    ET SERIES USER MANUALHYBRID INVERTEROffical websiteJIANGSU GOODWE POWER SUPPLY TECHNOLOGY CO.,LTD No. 90 Zijin Rd., New District, Suzhou, 215011, China www.goodwe.com [email protected] Master App SEMS Portal App SEMS Portal websitewww.semsportal.comLinkedIn340-00446-01Ver 1.02020-09-24 …

    ET Series Inverter, 20

  • LS STARVERT-iV5

    i Safety instructions Thank you for purchasing LS Vector Drives! SAFETY INSTRUCTIONS To prevent injury and property damage, follow these instructions. Incorrect operation due to ignoring instructions will cause harm or damage. The seriousness of which is indicated by the following symbols. …

    STARVERT-iV5 Inverter, 142

  • Meanwell A301-1K0

    MEANWELL DC/AC POWER INVERTERS A301/A302-1K0 = 1000 Watts A301/A302-1K7 = 1500 Watts A301/A302-2K5 = 2500 Watts A301 = 12VDC input A302 = 24VDC input 230VAC output Don’t disassemble Keep away from moisture Keep away from fire & heat Don’t stack inverters Maintain good ventilation …

    A301-1K0 Inverter, 13

  • Mitsubishi Electric FR-E800

    INVERTERINVERTER FR-E800 Instruction Manual (Communication)EHEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPANIB(NA)-0600871ENG-E(2011)MEE Printed in Japan Specifications subject to change without notice.FR-E800Instruction Manual (Communication)Compact, high functionality invertersModelFR- …

    FR-E800 Inverter, 226

  • Omron VARISPEED J7 —

    351Varispeed J7CIMR-J7AZVarispeed J7Small, simple and smart• V/f controlled inverter• Compact size• Good torque performance: 100% torque at 1.5 Hz, 150% at 3 Hz• 150% overload / 60sec• Overload detection function.• Motor thermal function• Freely configurable V/f curve• 4 programmable digital input• 1 …

    VARISPEED J7 — Inverter, 14

Italtecnica Sirio Universal Programming Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

Manual de programação

PT

Εγχειρίδιο προγραμματισμού

GR

Programovací příručka

CZ

Návod na programovanie

SK

Programmeerhandleiding

NL

Manual de programare

RO

Rel. 2.0

04/2020

Manual de programare

Sirio

Universal

Manuale di programmazione

Руководство по программированию

Programming manual

Manuel de programmation

Programmieranleitung

Manual de programación

IT

EN

F

DE

E

RUS

loading

Related Manuals for Italtecnica Sirio Universal

Summary of Contents for Italtecnica Sirio Universal

Like this post? Please share to your friends:
  • Частотный преобразователь веспер е3 8100 инструкция
  • Частотный преобразователь vemper vr100 инструкция по эксплуатации
  • Частотный преобразователь vector 100 инструкция
  • Частотный преобразователь веспер е4 8400 инструкция
  • Частотный преобразователь suswe 360 инструкция на русском языке