INVERTER

INSTRUCTION MANUAL (BASIC)

FR-F740-00023 to 12120-EC

Thank you for choosing this Mitsubishi Inverter.

This Instruction Manual (basic) is intended for users who «just want to run the inverter».

If you are going to utilize functions and performance, refer to the Instruction Manual (applied) [IB-0600193ENG].

Please read the provided CD-ROM for the instruction manual (applied).

1

PRODUCT CHECKING AND PARTS IDENTIFICATION………………………… 1

2

INSTALLATION AND WIRING ……………………………………………………………. 2

2.1

Peripheral devices ………………………………………………………………………………………..3

2.2

Method of removal and reinstallation of the front cover ……………………………………..4

2.3

Installation of the inverter and instructions ……………………………………………………….6

2.4

Wiring………………………………………………………………………………………………………….7

2.5

Power-off and magnetic contactor (MC)…………………………………………………………24

2.6

Precautions for use of the inverter…………………………………………………………………25

3

DRIVE THE MOTOR ………………………………………………………………………… 27

3.1

Step of operation ………………………………………………………………………………………..27

3.2

Operation panel (FR-DU07) …………………………………………………………………………28

3.3

Overheat protection of the motor by the inverter (Pr. 9)……………………………………33

3.4

Start/stop from the operation panel (PU operation mode) ………………………………..34

3.5

Make a start and stop with terminals (external operation) ………………………………..42

4

ADJUSTMENT ………………………………………………………………………………… 50

4.1

Simple mode parameter list………………………………………………………………………….50

4.2

Increase the starting torque (Pr. 0)………………………………………………………………..51

4.3

Limit the maximum and minimum output frequency (Pr. 1, Pr. 2)………………………52

4.4

When the rated motor frequency is 60Hz (Pr. 3)……………………………………………..53

4.5

Change acceleration and deceleration time (Pr. 7, Pr. 8) …………………………………54

4.6

Energy saving operation (Pr. 60)…………………………………………………………………..55

4.7

Selection of the operation command and frequency command locations (Pr. 79) .57

4.8

Parameter clear, all parameter clear ……………………………………………………………..58

4.9

Parameter copy and parameter verification ……………………………………………………59

4.10

Parameter list……………………………………………………………………………………………..61

4.11

Extended parameters ………………………………………………………………………………….63

4.12

Parameter list……………………………………………………………………………………………..64

5

TROUBLESHOOTING ……………………………………………………………………… 89

5.1

Reset method of protective function………………………………………………………………89

5.2

List of alarm display …………………………………………………………………………………….90

5.3

Causes and corrective actions ……………………………………………………………………..91

5.4

Correspondences between digital and actual characters ……………………………….102

5.5

Check and clear of the alarm history……………………………………………………………103

5.6

Check first when you have troubles …………………………………………………………….105

6

PRECAUTIONS FOR MAINTENANCE AND INSPECTION ………………… 108

6.1

Inspection item………………………………………………………………………………………….108

7

SPECIFICATIONS …………………………………………………………………………. 116

7.1

Rating………………………………………………………………………………………………………116

7.2

Common specifications ……………………………………………………………………………..117

7.3

Outline dimension drawings ……………………………………………………………………….119

7.4

Heatsink protrusion attachment procedure …………………………………………………..128

CONTENTS

700

1

2

3

4

5

6

7

loading

Summary of Contents for Mitsubishi Electric F700

www.proektant.org > Файловый архив > АРХИВ ФАЙЛОВ «ЭЛЕКТРОТЕХНИЧЕСКИЙ» > Каталоги производителей > 

Файл загрузил: Юра 123

Дата загрузки: 07 Апреля 2015 года, 22:43

Название файла Руководство по эксплуатации FR-F700_Mitsubiishi Electric.pdf
Описание

  (13,83 Мб)

  [просмотреть]  [ссылка на файл]  [загрузок: 2743]

Номенклатурный номер 159493 от 09 02 2005. Версия В.

Преобразователи частоты FR-F 700. Руководство по эксплуатации

Метки (теги): ПЧ Mitsubishi 

Размещено 07 Апреля 2015 года, 22:43 пользователем Юра 123
(все файлы, размещённые этим пользователем)
Рейтинг У данного файла пока нет оценок.
Ссылка Ссылка на эту страницу с описанием

www.proektant.org > Файловый архив > АРХИВ ФАЙЛОВ «ЭЛЕКТРОТЕХНИЧЕСКИЙ» > Каталоги производителей > 

Здравствуйте, Гость

Сейчас Вы присутствуете на форумах в статусе Гостя.
Для начала общения надо

зарегистрироваться

или пройти авторизацию:
Вам не пришло письмо с кодом активации?

Имя   
Пароль   
 
(забыли пароль?)
 
  Запомнить  

если Вы не зарегистрированы, то

пройдите регистрацию

Последние файлы в архиве «Электротехнический»

Каталог светильников СВС Лайтинг (SVS Lighting)

загрузил: Чистильщик

18 Декабря 2022 года, 22:55

т.п. 26.0085 альбом 1 одноцепные , двухцепные жб о…

загрузил: Юра 123

02 Ноября 2021 года, 07:29

Шифр 24.0067 Расчетные пролеты для одноцепных и мн…

загрузил: Юра 123

13 Октября 2021 года, 15:06

Серия 3.407.1-177жб опоры ВЛ-0,4кВ для тяжёлых кли…

загрузил: Юра 123

02 Октября 2021 года, 15:30

Пособие по проектированию защиты от коррозии бетон…

загрузил: Юра 123

09 Сентября 2021 года, 06:53

Типовые проектные решения 407-03-433.87 Альбом 3

загрузил: Юра 123

18 Мая 2021 года, 11:15

Типовые проектные решения 407-03-433.87 Альбом 2

загрузил: Юра 123

18 Мая 2021 года, 11:13

Типовые проектные решения 407-03-433.87 Альбом 1 ч…

загрузил: Юра 123

18 Мая 2021 года, 11:11

типовые проектные решения 407-03-433.87 Альбом 1 ч…

загрузил: Юра 123

18 Мая 2021 года, 11:07

Типовые материалы для проектирования 407-03-641

загрузил: Юра 123

18 Мая 2021 года, 11:03

Типовой проект 407-03-624.91

загрузил: Юра 123

18 Мая 2021 года, 08:37

..»Пополам»..

загрузил: Юра 123

15 Мая 2021 года, 11:08

Забудский Е.И.Электрические машины.Трансформаторы….

загрузил: Юра 123

12 Мая 2021 года, 10:40

ОДМ 218.5.010-2018 «Типовые проектные решения по и…

загрузил: Виктop

14 Августа 2020 года, 11:35

Светодиодные светильники для спортзалов компании О…

загрузил: Строитель

24 Июля 2020 года, 09:59

Светодиодные светильники компании ООО «Тэнс». Прай…

загрузил: Строитель

24 Июля 2020 года, 09:57

Светодиодные светильники для ЖКХ компании ООО «Тэн…

загрузил: Строитель

24 Июля 2020 года, 09:56

Светодиодные светильники компании ООО «Тэнс». Прай…

загрузил: Строитель

24 Июля 2020 года, 09:56

Светодиодные уличные, магистральные, промышленные …

загрузил: Строитель

24 Июля 2020 года, 09:44

Инструкция по строительству кабельной канализации …

загрузил: Юра 123

25 Июня 2020 года, 09:57

INVERTER

INSTRUCTION MANUAL (BASIC)

FR-F740-00023 to 12120-EC

Thank you for choosing this Mitsubishi Inverter.

This Instruction Manual (basic) is intended for users who «just want to run the inverter».

If you are going to utilize functions and performance, refer to the Instruction Manual (applied) [IB-0600193ENG].

Please read the provided CD-ROM for the instruction manual (applied).

1

PRODUCT CHECKING AND PARTS IDENTIFICATION………………………… 1

2

INSTALLATION AND WIRING ……………………………………………………………. 2

2.1

Peripheral devices ………………………………………………………………………………………..3

2.2

Method of removal and reinstallation of the front cover ……………………………………..4

2.3

Installation of the inverter and instructions ……………………………………………………….6

2.4

Wiring………………………………………………………………………………………………………….7

2.5

Power-off and magnetic contactor (MC)…………………………………………………………24

2.6

Precautions for use of the inverter…………………………………………………………………25

3

DRIVE THE MOTOR ………………………………………………………………………… 27

3.1

Step of operation ………………………………………………………………………………………..27

3.2

Operation panel (FR-DU07) …………………………………………………………………………28

3.3

Overheat protection of the motor by the inverter (Pr. 9)……………………………………33

3.4

Start/stop from the operation panel (PU operation mode) ………………………………..34

3.5

Make a start and stop with terminals (external operation) ………………………………..42

4

ADJUSTMENT ………………………………………………………………………………… 50

4.1

Simple mode parameter list………………………………………………………………………….50

4.2

Increase the starting torque (Pr. 0)………………………………………………………………..51

4.3

Limit the maximum and minimum output frequency (Pr. 1, Pr. 2)………………………52

4.4

When the rated motor frequency is 60Hz (Pr. 3)……………………………………………..53

4.5

Change acceleration and deceleration time (Pr. 7, Pr. 8) …………………………………54

4.6

Energy saving operation (Pr. 60)…………………………………………………………………..55

4.7

Selection of the operation command and frequency command locations (Pr. 79) .57

4.8

Parameter clear, all parameter clear ……………………………………………………………..58

4.9

Parameter copy and parameter verification ……………………………………………………59

4.10

Parameter list……………………………………………………………………………………………..61

4.11

Extended parameters ………………………………………………………………………………….63

4.12

Parameter list……………………………………………………………………………………………..64

5

TROUBLESHOOTING ……………………………………………………………………… 89

5.1

Reset method of protective function………………………………………………………………89

5.2

List of alarm display …………………………………………………………………………………….90

5.3

Causes and corrective actions ……………………………………………………………………..91

5.4

Correspondences between digital and actual characters ……………………………….102

5.5

Check and clear of the alarm history……………………………………………………………103

5.6

Check first when you have troubles …………………………………………………………….105

6

PRECAUTIONS FOR MAINTENANCE AND INSPECTION ………………… 108

6.1

Inspection item………………………………………………………………………………………….108

7

SPECIFICATIONS …………………………………………………………………………. 116

7.1

Rating………………………………………………………………………………………………………116

7.2

Common specifications ……………………………………………………………………………..117

7.3

Outline dimension drawings ……………………………………………………………………….119

7.4

Heatsink protrusion attachment procedure …………………………………………………..128

CONTENTS

700

1

2

3

4

5

6

7

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

INVERTER

INSTRUCTION MANUAL (BASIC)

FR-F720-0.75K to 110K

FR-F740-0.75K to 560K

Thank you for choosing this Mitsubishi Inverter.

This Instruction Manual (basic) is intended for users who «just want to run the inverter».

If you are going to utilize functions and performance, refer to the Instruction Manual (applied) [IB-0600177ENG].

The Instruction Manual (applied) is separately available from where you purchased the inverter or your Mitsubishi

sales representative.

1

PRODUCT CHECKING AND PARTS IDENTIFICATION …………………………1

2

INSTALLATION AND WIRING …………………………………………………………….2

2.1

Peripheral devices ………………………………………………………………………………………..3

2.2

Method of removal and reinstallation of the front cover……………………………………..5

2.3

Installation of the inverter and instructions……………………………………………………….7

2.4

Wiring………………………………………………………………………………………………………….8

2.5

Connection of stand-alone option units………………………………………………………….28

2.6

Power-off and magnetic contactor (MC) ………………………………………………………..36

2.7

Precautions for use of the inverter ………………………………………………………………..37

2.8

Failsafe of the system which uses the inverter ……………………………………………….39

3

DRIVE THE MOTOR …………………………………………………………………………40

3.1

Step of operation ………………………………………………………………………………………..40

3.2

Operation panel (FR-DU07) …………………………………………………………………………41

3.3

Overheat protection of the motor by the inverter (Pr. 9) …………………………………..46

3.4

When the rated motor frequency is 50Hz (Pr. 3) …………………………………………….47

3.5

Start/stop from the operation panel (PU operation mode) ………………………………..48

3.6

Start and stop using terminals (External operation)…………………………………………57

4

ADJUSTMENT …………………………………………………………………………………65

4.1

Simple mode parameter list………………………………………………………………………….65

4.2

Increasing the starting torque (Pr. 0)……………………………………………………………..66

4.3

Limiting the maximum and minimum output frequency (Pr. 1, Pr. 2)………………….67

4.4

Changing acceleration and deceleration time (Pr. 7, Pr. 8) ………………………………68

4.5

Energy saving operation (Pr. 60)…………………………………………………………………..69

4.6

Selection of the operation command and frequency command locations (Pr. 79).71

4.7

Parameter clear, all parameter clear……………………………………………………………..72

4.8

Parameter copy and parameter verification ……………………………………………………73

4.9

Parameter list……………………………………………………………………………………………..75

5

TROUBLESHOOTING …………………………………………………………………….102

5.1

Reset method of protective function…………………………………………………………….102

5.2

List of fault or alarm display………………………………………………………………………..103

5.3

Causes and corrective actions ……………………………………………………………………104

5.4

Correspondences between digital and actual characters ……………………………….115

5.5

Check and clear of the faults history ……………………………………………………………116

5.6

Check first when you have a trouble ……………………………………………………………118

6

PRECAUTIONS FOR MAINTENANCE AND INSPECTION………………….125

6.1

Inspection item………………………………………………………………………………………….125

7

SPECIFICATIONS…………………………………………………………………………..134

7.1

Rating………………………………………………………………………………………………………134

7.2

Common specifications ……………………………………………………………………………..136

7.3

Outline dimension drawings ……………………………………………………………………….138

7.4

Heatsink protrusion attachment procedure …………………………………………………..149

CONTENTS

700

1

2

3

4

5

6

7

loading

Summary of Contents for Mitsubishi Electric F700

Like this post? Please share to your friends:
  • Частотный преобразователь mitsubishi a500 инструкция
  • Частотный преобразователь ls s100 инструкция
  • Частотный преобразователь лидер в601 инструкция
  • Частотный преобразователь kewo ad800n инструкция
  • Частотный преобразователь лидер а300 инструкция