    PREFACE Congratulation and thank you for your purchase of our unit. Our aim is to provide a high-quality generator set to achieve customer satisfaction, and we are confident that your choice will be justified. This manual provides correct installation, usage and maintenance instruction and gives all basic information to ensure satisfactory and reliable operation of our unit.
  • Page 4: Table Of Contents

    CONTENTS 1. Main Technical Specifications and Data 2. Preparatory Steps for Operation 3. Safety procedure for Servicing 4. Warm-up Procedure 5. Starting-up Procedure and running 6. Stop Procedure 7. The Functions of the Digital Panel 8. Electrical appliance 9. Malfunction and Countermeasures 10.

  • Page 5: Main Technical Specifications And Data

    1. Main Technical Specifications and Data MODEL ITEM Rated Frequency(Hz) Rated Power (KVA) 10.5 Max Power (KVA) 10.0 10.5 11.5 Rated Voltage (V) 240/120 400/230 416/240 115/230 37.5/75 13.7 14.6 Rated Current (A) 73.8/36.9 3600 3000 3600 Rated Rotation Speed (r/min) 3000 Single-phase Three-phase…

  • Page 6
    2. Modified coefficient table of ambient condition power MODEL The conditions of generator rated output: ITEM Altitude: 0 m Ambient temperature: 25 Relative humidity: 30% Mode KM2V80 Ambient modified coefficient: C (Relative humidity 30%) Type Two-cylinder, V-twins, Air-cooled, 4-stroke, Bow-wave type Dispacement (ml) Ambient temperature ( ) Altitude…
  • Page 7: Preparatory Steps For Operation

    2. PREPARATORY STEPS FOR OPERATION 12. APPENDIX 1. The choice of the electric cable 1. Environmental Requirements The choice of the electric cable depends on the allowable current of the cable 1-1 Outdoors use and the distance between the load and the generator. And the cable section 1) Install Generator in a dry and dustless place.

  • Page 8
    b.KDE12STA3 2. Preparation for the engine 2-1 Initial start check Check the each part of the generator before starting. Making sure that anybody near the generator is warned, before starting the generator. Be care of these parts in the generator, such as rotary parts, hot parts, high- voltage parts.
  • Page 9
    Three-phase 2-3 Check the following items for the initial start: (1) Check the engine oil a.KDE12STA (2) Check the cooling water in radiator. NOTE: Screw down (3) Check the fuel. (4) Check the fuel pipe. (5) Check the battery voltage. (6) Check the grounding protection.
  • Page 10
    b.KDE12EA3 (9) Clean the dirty and dusty in the unit. 1) Check the engine oil a) Check the engine oil level with oil dipstick. And the oil level should be between the H (high) and L (low) positions. b) If the oil level is lower than L position, add the engine oil. c) Check if the engine is clean or not.
  • Page 11
    Tighten the radiator cover by turn it in right after checking. Otherwise, the cooling water may be vaporized, causing a fatal fault. Single phase a.KDE12EA 3) Check the fan belt Check the tension and the extend length of the belt. Check the belt if good or not.
  • Page 12
    Digital panel electric system Troubleshooting Fault Reason 1. The fuse on the panel breaks Replace the fuse 2. The electric starting switch fails Check or replace the electric starting No display or poor connection switch 3. Poor connection of inserter Check module No.9, PIN inserter and data wire Refill in oil 1.
  • Page 13
    8) Clean the dirty and dusty in the unit. Fault Reason Solution Check the unit inner for dusty and dirty and clean it. Bad voltmeter Replace voltmeter Check the muffler and the places near the engine for trash or flammable materials Bad AVR Consult with dealer and clean them.
  • Page 14: Safety Procedure For Servicing

    Fault Reason Solution 3. SAFETY PRECATIONS FOR SERVICING engine oil is not enough. Fill engine oil Engine stops because of low oil Badness oil switch Replace switch 1. The installation and maintenance work should be operated by professional pressure. maintainer. Engine air cleaner wall up Replace filter 2.

  • Page 15: Warm-Up Procedure

    CAUTION 4. WARM-UP PROCEDURE The usage of the battery It will explode to cause a severe accident if the battery used in a wrong way. 1. Check the fuel before every start. Remove the negative terminal when servicing the generator. 2.

  • Page 16: Starting-Up Procedure And Running

    5. STARTING-UP&RUNNING PROCEDURE 10. SIMPLIFIED TROUBLESHOOTING GUIDE This guide is intended to give brief information for troubleshooting with no testing 1. According to the step of 1-10, finish the starting-up procedure. or measuring instruments to check the unit. 2. Ensure voltmeter indicates normal, (single phase: 230V, three phase: 400V) However, testing and measuring instruments are required to diagnose parts and 3.

  • Page 17
    8. Load Daily check 1000 Check & service item CAUTION Clean the inner of the fuel tank. Replace the air cleaner element Do not start 2 or more machines simultaneously. Start them one by one. Do not use floodlight together with other machines. Check valve clearance.
  • Page 18: Stop Procedure

    5) Three-phase generating set 9. MALFUNCTION AND COUNTERMEASURES Balance three phases during the operation. Stop the engine for check if the tolerances exceed 20%. Be sure to keep the tolerance among three phases less than 20%. 1. Maintenance Schedule The load for each phase must below the rated load as well as the current must Check and clean replace less than rated current.

  • Page 19: The Functions Of The Digital Panel

    8. ELECTRIC APPLIANCE 7. THE FUNCTIONS OF THE DIGITAL PANEL Electric appliance particularly motor-driven equipment will produce very high current PVC Label (Single-phase) while starting, the below table provides the reference for connecting these apparatus to the generator set. WATTAGE EXAMPLE TYPICAL TYPE…

  • Page 20
    OUTPUT CURRENT: indicating generator current Three-phase current: Indicating generator current. Single phase power: Indicating generator power. VOLTAGE: indicating generator voltage Generator voltage: Indicating generator voltage. LONG-RANGE CONTROL: indicating long-range control using if or not Generator running: Indicating the existence of electrical power. RUNNING: indicating electric power exist if or not Running trouble: Indicating running trouble, check it according to the code map list.

Каталог

Генератор дизельный KIPOR KDE12000EA3

Генератор дизельный KIPOR KDE12000EA3

KIPOR

Генератор дизельный KIPOR KDE12000EA3

Подробнее

Генератор дизельный KIPOR KDE12000EA3

Способы получения

Рассчитать доставку

О товаре

Дизельный генератор Kipor KDE12000EA3 – установка предназначенная для питания оборудования во время аварии на основной электросети или при работе на удаленных объектах. Профессиональный дизельный двигатель с верхним расположением клапанов и смазкой под давлением рассчитан на длительную работу без остановок и имеет большой ресурс.

Дизельный генератор Kipor KDE12000EA3 – установка предназначенная для питания оборудования во время аварии на основной электросети или при работе на удаленных объектах. Профессиональный дизельный…

Показать ещеСвернуть

Характеристики

Производитель


KIPOR

?

В

напряжение


380/220

вид топлива


дизель

тип двигателя


4-х тактный

стартер


ручной/электростартер

эл. выходы 380/220/12 В


1/2/1

?

кВт

Мощность номинальная


8.8

?

кВт

Мощность максимальная


11

?

см3

объем двигателя


992

объем топливного бака (Литр)


25

?

А*ч

номинальный ток


36.9

Норма расхода топлива, л/маш.-час


1.5

Индикатор уровня топлива


да

Выход 12В


да

класс защиты


IP23

Датчик уровня масла


да

Колеса и ручки


нет

?

мм

габариты в упаковке


930x620x695 мм

Вес брутто


195

Вес нетто


185

Гарантия


1 год

Родина бренда


Германия

марка двигателя


Daihatsu KM2V86F

Все характеристики

Цена действительна только для интернет-магазина и может отличаться от цен в розничных магазинах

Не знаете как выбрать Генератор дизельный KIPOR KDE12000EA3?

Посетите наш магазин

alt

Пункт выдачи:
м.Авиамоторная, 2-й Кабельный проезд, дом 1, корпус 2, павильон 115

Свяжитесь с нами

alt

Наши менеджеры подробно расскажут о характеристиках
товара и помогут Вам выбрать подходящую модель

Подписывайтесь на наш Youtube

Как собрать Снегоуборщик SGC 4800E Huter??? Подробно расскажем в нашем новом обзоре!

Иверторные Генераторы CARVER : Обновленная линейка от 2 кВт до 5кВт, очень крутой дизайн!

  • Описание и характеристики
  • Отзывы
  • Похожие товары

Описание и характеристики

Дизельный генератор Kipor KDE12000EA3 – установка предназначенная для питания оборудования во время аварии на основной электросети или при работе на удаленных объектах. Профессиональный дизельный двигатель с верхним расположением клапанов и смазкой под давлением рассчитан на длительную работу без остановок и имеет большой ресурс.

Дизельный генератор Kipor KDE12000EA3 – установка предназначенная для питания оборудования во время аварии на основной электросети или при работе на удаленных объектах. Профессиональный дизельный…

Показать ещеСвернуть

Срок гарантии — 1 год на товары KIPOR

Официальная гарантия
1 год

Германия — родина бренда

Страна производителя Германия

Магазин инструментов — официальный поставщик
KIPOR

Официальный поставщик
KIPOR

Характеристики

Технические характеристики Генератор дизельный KIPOR KDE12000EA3

Производитель


KIPOR

?

В

напряжение


380/220

вид топлива


дизель

тип двигателя


4-х тактный

стартер


ручной/электростартер

эл. выходы 380/220/12 В


1/2/1

?

кВт

Мощность номинальная


8.8

?

кВт

Мощность максимальная


11

?

см3

объем двигателя


992

объем топливного бака (Литр)


25

?

А*ч

номинальный ток


36.9

Норма расхода топлива, л/маш.-час


1.5

Индикатор уровня топлива


да

Выход 12В


да

класс защиты


IP23

Датчик уровня масла


да

Колеса и ручки


нет

?

мм

габариты в упаковке


930x620x695 мм

Вес брутто


195

Вес нетто


185

Гарантия


1 год

Родина бренда


Германия

марка двигателя


Daihatsu KM2V86F

Все характеристики

Документация

Похожие товары

Распродажа остатков

Оставить отзыв

У данного товара нет отзывов. Станьте первым, кто оставил отзыв об этом товаре!

  • Сопутствующие товары

Технические характеристики дизельного генератора Kipor KDE12000EA3

Основная информация об электростанции Kipor KDE12000EA3
Производитель Kipor
Страна производителя Китай
Модель KDE12000EA3
Мощность (максимальная), кВт 9.35
Мощность (номинальная), кВт 8.5
Кол-во фаз три
Выходное напряжение, В 380
Максимальная сила тока, А 14.2
Тип запуска электростартер
Автомат ввода резерва отсутствует
Функция сварки отсутствует
Инвертор нет
Уровень шума, дБ 82
Диапазон рабочих температур -25…+30
Относительная влажность воздуха не более 98%
Двигатель
Модель двигателя Yanmar KD2V86F
Используемое топливо дизель
Удельный расход топлива, л/кВт*час 0.24
Расход топлива, л/час (при нагрузке 100%) 2.26
Расход топлива, л/час (при нагрузке 75%) 1.7
Расход топлива, л/час (при нагрузке 50%) 1.12
Частота вращения двигателя, об/мин 3000
Система охлаждения двигателя жидкостная
Силовой генератор
Тип альтернатора синхронный
Кол-во полюсов 4
Возбуждение генератора самовозбуждение
Защита от перегрузок есть
Габариты и вес
Тип исполнения на раме
Класс защиты IP23
Ёмкость топливного бака, л 25
Время автономной работы, ч 14.7
Длина, мм 930
Ширина, мм 620
Высота, мм 696
Масса, кг 185
Гарантийный срок 24 месяца или 1000 моточасов (для моделей с оборотами двигателя 3000 об/мин — 500 моточасов), в зависимости от того, какое событие наступит раньше.

Трёхфазная дизельная электростанция с электростартером KDE12000EA3 от китайского производителя Kipor рассчитана для бесперебойного электроснабжения строительных площадкок или небольших производственных площадей. Помимо этого, электростанция Kipor KDE12000EA3 — идеальный вариант для дома, загородного участка, в походах, на охоте или рыбалке. Конструкционные особенности электростанции позволяют использовать её и как аварийный, и как постоянный источник независимого электроснабжения. К данному генератору возможно подключить один или несколько электроприборов максимальной суммарной мощностью 9.35 кВт при напряжении 380 В. Современный двигатель внутреннего сгорания Yanmar KD2V86F жидкостного охлаждения со встроенным датчиком уровня масла (предотвращающим повреждение механизмов двигателя при его отсутствии) расходует при нагрузке 75% не более 1.7 л/ч дизельного топлива. Генератор в базовой комплектации снабжён топливным баком объёмом 25 л позволяющим автономно работать до 15 часов без дополнительной заправки. Также отличительной чертой генераторов данного типа является низкий уровень шума по сравнению с аналогами иных производителей, а качественный синхронный альтернатор позволяет добиться высокой точности выходного напряжения.

Динамика изменения цены на генератор Kipor KDE12000EA3

Отзывы о генераторе Kipor KDE12000EA3

Генераторы со схожими характеристиками от других производителей

Дизельный генератор Daewoo DDAE 10000DSE-3
(Южная Корея)

126 990 руб.

Дизельный генератор Leega LDG12-3 E
(Китай)

178 800 руб.

Дизельный генератор Champion DG10000E-3
(Китай)

196 700 руб.

Дизельный генератор АМПЕРОС АД 15-Т400 B
(Россия)

227 300 руб.

Дизельный генератор Elitech ДЭС 12000ЕТM
(Россия)

235 415 руб.

Дизельный генератор MOTOR АД15-Т400-R
(Россия)

300 779 руб.

Дизельный генератор CTG AD-13YA
(Китай)

368 552 руб.

Дизельный генератор Fubag DS 22 DAC ES
(Германия)

398 025 руб.

Дизельный генератор Вепрь АДП 10-Т400/230 ВЛ-БС
(Россия)

401 530 руб.

Дизельный генератор MVAE АД-18-400-Р
(Китай)

422 006 руб.



Мини-контейнер

Цена: от 81 000 руб.

Комплект расходных материалов

Цена: от 10 266 руб.

Перейти к контенту

Kipor KDE12EA Operation Manual

  1. Manuals
  2. Brands
  3. Kipor Manuals
  4. Inverter
  5. KDE12EA
  6. Operation manual
  • Contents
    Table of Contents

  • Bookmarks

Quick Links

R

GENERATOR

WUXI KIPOR POWER CO., LTD.

Single-phase:

KDE12EA

KDE12STA

Three-phase:

KDE12EA3

KDE12STA3

Related Manuals for Kipor KDE12EA

Summary of Contents for Kipor KDE12EA

  • Page 1
    GENERATOR WUXI KIPOR POWER CO., LTD. Single-phase: KDE12EA KDE12STA Three-phase: KDE12EA3 KDE12STA3…
  • Page 3
    PREFACE Congratulation and thank you for your purchase of our unit. Our aim is to provide a high-quality generator set to achieve customer satisfaction, and we are confident that your choice will be justified. This manual provides correct installation, usage and maintenance instruction and gives all basic information to ensure satisfactory and reliable operation of our unit.
  • Page 4: Table Of Contents

    CONTENTS 1. Main Technical Specifications and Data 2. Preparatory Steps for Operation 3. Safety procedure for Servicing 4. Warm-up Procedure 5. Starting-up Procedure and running 6. Stop Procedure 7. The Functions of the Digital Panel 8. Electrical appliance 9. Malfunction and Countermeasures 10.

  • Page 5: Main Technical Specifications And Data

    1. Main Technical Specifications and Data MODEL ITEM Rated Frequency(Hz) Rated Power (KVA) 10.5 Max Power (KVA) 10.0 10.5 11.5 Rated Voltage (V) 240/120 400/230 416/240 115/230 37.5/75 13.7 14.6 Rated Current (A) 73.8/36.9 3600 3000 3600 Rated Rotation Speed (r/min) 3000 Single-phase Three-phase…

  • Page 6
    2. Modified coefficient table of ambient condition power MODEL The conditions of generator rated output: ITEM Altitude: 0 m Ambient temperature: 25 Relative humidity: 30% Mode KM2V80 Ambient modified coefficient: C (Relative humidity 30%) Type Two-cylinder, V-twins, Air-cooled, 4-stroke, Bow-wave type Dispacement (ml) Ambient temperature ( ) Altitude…
  • Page 7: Preparatory Steps For Operation

    2. PREPARATORY STEPS FOR OPERATION 12. APPENDIX 1. The choice of the electric cable 1. Environmental Requirements The choice of the electric cable depends on the allowable current of the cable 1-1 Outdoors use and the distance between the load and the generator. And the cable section 1) Install Generator in a dry and dustless place.

  • Page 8
    b.KDE12STA3 2. Preparation for the engine 2-1 Initial start check Check the each part of the generator before starting. Making sure that anybody near the generator is warned, before starting the generator. Be care of these parts in the generator, such as rotary parts, hot parts, high- voltage parts.
  • Page 9
    Three-phase 2-3 Check the following items for the initial start: (1) Check the engine oil a.KDE12STA (2) Check the cooling water in radiator. NOTE: Screw down (3) Check the fuel. (4) Check the fuel pipe. (5) Check the battery voltage. (6) Check the grounding protection.
  • Page 10
    b.KDE12EA3 (9) Clean the dirty and dusty in the unit. 1) Check the engine oil a) Check the engine oil level with oil dipstick. And the oil level should be between the H (high) and L (low) positions. b) If the oil level is lower than L position, add the engine oil. c) Check if the engine is clean or not.
  • Page 11
    Tighten the radiator cover by turn it in right after checking. Otherwise, the cooling water may be vaporized, causing a fatal fault. Single phase a.KDE12EA 3) Check the fan belt Check the tension and the extend length of the belt. Check the belt if good or not.
  • Page 12
    Digital panel electric system Troubleshooting Fault Reason 1. The fuse on the panel breaks Replace the fuse 2. The electric starting switch fails Check or replace the electric starting No display or poor connection switch 3. Poor connection of inserter Check module No.9, PIN inserter and data wire Refill in oil 1.
  • Page 13
    8) Clean the dirty and dusty in the unit. Fault Reason Solution Check the unit inner for dusty and dirty and clean it. Bad voltmeter Replace voltmeter Check the muffler and the places near the engine for trash or flammable materials Bad AVR Consult with dealer and clean them.
  • Page 14: Safety Procedure For Servicing

    Fault Reason Solution 3. SAFETY PRECATIONS FOR SERVICING engine oil is not enough. Fill engine oil Engine stops because of low oil Badness oil switch Replace switch 1. The installation and maintenance work should be operated by professional pressure. maintainer. Engine air cleaner wall up Replace filter 2.

  • Page 15: Warm-Up Procedure

    CAUTION 4. WARM-UP PROCEDURE The usage of the battery It will explode to cause a severe accident if the battery used in a wrong way. 1. Check the fuel before every start. Remove the negative terminal when servicing the generator. 2.

  • Page 16: Starting-Up Procedure And Running

    5. STARTING-UP&RUNNING PROCEDURE 10. SIMPLIFIED TROUBLESHOOTING GUIDE This guide is intended to give brief information for troubleshooting with no testing 1. According to the step of 1-10, finish the starting-up procedure. or measuring instruments to check the unit. 2. Ensure voltmeter indicates normal, (single phase: 230V, three phase: 400V) However, testing and measuring instruments are required to diagnose parts and 3.

  • Page 17
    8. Load Daily check 1000 Check & service item CAUTION Clean the inner of the fuel tank. Replace the air cleaner element Do not start 2 or more machines simultaneously. Start them one by one. Do not use floodlight together with other machines. Check valve clearance.
  • Page 18: Stop Procedure

    5) Three-phase generating set 9. MALFUNCTION AND COUNTERMEASURES Balance three phases during the operation. Stop the engine for check if the tolerances exceed 20%. Be sure to keep the tolerance among three phases less than 20%. 1. Maintenance Schedule The load for each phase must below the rated load as well as the current must Check and clean replace less than rated current.

  • Page 19: The Functions Of The Digital Panel

    8. ELECTRIC APPLIANCE 7. THE FUNCTIONS OF THE DIGITAL PANEL Electric appliance particularly motor-driven equipment will produce very high current PVC Label (Single-phase) while starting, the below table provides the reference for connecting these apparatus to the generator set. WATTAGE EXAMPLE TYPICAL TYPE…

  • Page 20
    OUTPUT CURRENT: indicating generator current Three-phase current: Indicating generator current. Single phase power: Indicating generator power. VOLTAGE: indicating generator voltage Generator voltage: Indicating generator voltage. LONG-RANGE CONTROL: indicating long-range control using if or not Generator running: Indicating the existence of electrical power. RUNNING: indicating electric power exist if or not Running trouble: Indicating running trouble, check it according to the code map list.

Инструкция в формате — PDF

Количество страниц — 24 страницы

Размер — 1.6 МБ

Доступно — Бесплатное скачивание

Доступно — Онлайн чтение

background image 9.35 Мощность (номинальная), кВт 8.5 Кол-во фаз три Выходное напряжение, В 380 Максимальная сила тока, А 14.2 Тип запуска электростартер Автомат ввода резерва отсутствует Функция сварки отсутствует Инвертор нет Уровень шума, дБ 82 Диапазон рабочих температур -25…+30 Относительная влажность воздуха не более 98%

Двигатель
Модель двигателя Yanmar KD2V86F
Используемое топливо дизель
Удельный расход топлива, л/кВт*час 0.24
Расход топлива, л/час (при нагрузке 100%) 2.26
Расход топлива, л/час (при нагрузке 75%) 1.7
Расход топлива, л/час (при нагрузке 50%) 1.12
Частота вращения двигателя, об/мин 3000
Система охлаждения двигателя жидкостная
Силовой генератор
Тип альтернатора синхронный
Кол-во полюсов 4
Возбуждение генератора самовозбуждение
Защита от перегрузок есть
Габариты и вес
Тип исполнения на раме
Класс защиты IP23
Ёмкость топливного бака, л 25
Время автономной работы, ч 14.7
Длина, мм 930
Ширина, мм 620
Высота, мм 696
Масса, кг 185
Гарантийный срок 24 месяца или 1000 моточасов (для моделей с оборотами двигателя 3000 об/мин — 500 моточасов), в зависимости от того, какое событие наступит раньше.

Трёхфазная дизельная электростанция с электростартером KDE12000EA3 от китайского производителя Kipor рассчитана для бесперебойного электроснабжения строительных площадкок или небольших производственных площадей. Помимо этого, электростанция Kipor KDE12000EA3 — идеальный вариант для дома, загородного участка, в походах, на охоте или рыбалке. Конструкционные особенности электростанции позволяют использовать её и как аварийный, и как постоянный источник независимого электроснабжения. К данному генератору возможно подключить один или несколько электроприборов максимальной суммарной мощностью 9.35 кВт при напряжении 380 В. Современный двигатель внутреннего сгорания Yanmar KD2V86F жидкостного охлаждения со встроенным датчиком уровня масла (предотвращающим повреждение механизмов двигателя при его отсутствии) расходует при нагрузке 75% не более 1.7 л/ч дизельного топлива. Генератор в базовой комплектации снабжён топливным баком объёмом 25 л позволяющим автономно работать до 15 часов без дополнительной заправки. Также отличительной чертой генераторов данного типа является низкий уровень шума по сравнению с аналогами иных производителей, а качественный синхронный альтернатор позволяет добиться высокой точности выходного напряжения.

Динамика изменения цены на генератор Kipor KDE12000EA3

Отзывы о генераторе Kipor KDE12000EA3

Генераторы со схожими характеристиками от других производителей

Дизельный генератор Daewoo DDAE 10000DSE-3
(Южная Корея)

126 990 руб.

Дизельный генератор Leega LDG12-3 E
(Китай)

178 800 руб.

Дизельный генератор Champion DG10000E-3
(Китай)

196 700 руб.

Дизельный генератор АМПЕРОС АД 15-Т400 B
(Россия)

227 300 руб.

Дизельный генератор Elitech ДЭС 12000ЕТM
(Россия)

235 415 руб.

Дизельный генератор MOTOR АД15-Т400-R
(Россия)

300 779 руб.

Дизельный генератор CTG AD-13YA
(Китай)

368 552 руб.

Дизельный генератор Fubag DS 22 DAC ES
(Германия)

398 025 руб.

Дизельный генератор Вепрь АДП 10-Т400/230 ВЛ-БС
(Россия)

401 530 руб.

Дизельный генератор MVAE АД-18-400-Р
(Китай)

422 006 руб.



Мини-контейнер

Цена: от 81 000 руб.

Комплект расходных материалов

Цена: от 10 266 руб.

Перейти к контенту

Kipor KDE12EA Operation Manual

  1. Manuals
  2. Brands
  3. Kipor Manuals
  4. Inverter
  5. KDE12EA
  6. Operation manual
  • Contents
    Table of Contents

  • Bookmarks

Quick Links

R

GENERATOR

WUXI KIPOR POWER CO., LTD.

Single-phase:

KDE12EA

KDE12STA

Three-phase:

KDE12EA3

KDE12STA3

Related Manuals for Kipor KDE12EA

Summary of Contents for Kipor KDE12EA

  • Page 1
    GENERATOR WUXI KIPOR POWER CO., LTD. Single-phase: KDE12EA KDE12STA Three-phase: KDE12EA3 KDE12STA3…
  • Page 3
    PREFACE Congratulation and thank you for your purchase of our unit. Our aim is to provide a high-quality generator set to achieve customer satisfaction, and we are confident that your choice will be justified. This manual provides correct installation, usage and maintenance instruction and gives all basic information to ensure satisfactory and reliable operation of our unit.
  • Page 4: Table Of Contents

    CONTENTS 1. Main Technical Specifications and Data 2. Preparatory Steps for Operation 3. Safety procedure for Servicing 4. Warm-up Procedure 5. Starting-up Procedure and running 6. Stop Procedure 7. The Functions of the Digital Panel 8. Electrical appliance 9. Malfunction and Countermeasures 10.

  • Page 5: Main Technical Specifications And Data

    1. Main Technical Specifications and Data MODEL ITEM Rated Frequency(Hz) Rated Power (KVA) 10.5 Max Power (KVA) 10.0 10.5 11.5 Rated Voltage (V) 240/120 400/230 416/240 115/230 37.5/75 13.7 14.6 Rated Current (A) 73.8/36.9 3600 3000 3600 Rated Rotation Speed (r/min) 3000 Single-phase Three-phase…

  • Page 6
    2. Modified coefficient table of ambient condition power MODEL The conditions of generator rated output: ITEM Altitude: 0 m Ambient temperature: 25 Relative humidity: 30% Mode KM2V80 Ambient modified coefficient: C (Relative humidity 30%) Type Two-cylinder, V-twins, Air-cooled, 4-stroke, Bow-wave type Dispacement (ml) Ambient temperature ( ) Altitude…
  • Page 7: Preparatory Steps For Operation

    2. PREPARATORY STEPS FOR OPERATION 12. APPENDIX 1. The choice of the electric cable 1. Environmental Requirements The choice of the electric cable depends on the allowable current of the cable 1-1 Outdoors use and the distance between the load and the generator. And the cable section 1) Install Generator in a dry and dustless place.

  • Page 8
    b.KDE12STA3 2. Preparation for the engine 2-1 Initial start check Check the each part of the generator before starting. Making sure that anybody near the generator is warned, before starting the generator. Be care of these parts in the generator, such as rotary parts, hot parts, high- voltage parts.
  • Page 9
    Three-phase 2-3 Check the following items for the initial start: (1) Check the engine oil a.KDE12STA (2) Check the cooling water in radiator. NOTE: Screw down (3) Check the fuel. (4) Check the fuel pipe. (5) Check the battery voltage. (6) Check the grounding protection.
  • Page 10
    b.KDE12EA3 (9) Clean the dirty and dusty in the unit. 1) Check the engine oil a) Check the engine oil level with oil dipstick. And the oil level should be between the H (high) and L (low) positions. b) If the oil level is lower than L position, add the engine oil. c) Check if the engine is clean or not.
  • Page 11
    Tighten the radiator cover by turn it in right after checking. Otherwise, the cooling water may be vaporized, causing a fatal fault. Single phase a.KDE12EA 3) Check the fan belt Check the tension and the extend length of the belt. Check the belt if good or not.
  • Page 12
    Digital panel electric system Troubleshooting Fault Reason 1. The fuse on the panel breaks Replace the fuse 2. The electric starting switch fails Check or replace the electric starting No display or poor connection switch 3. Poor connection of inserter Check module No.9, PIN inserter and data wire Refill in oil 1.
  • Page 13
    8) Clean the dirty and dusty in the unit. Fault Reason Solution Check the unit inner for dusty and dirty and clean it. Bad voltmeter Replace voltmeter Check the muffler and the places near the engine for trash or flammable materials Bad AVR Consult with dealer and clean them.
  • Page 14: Safety Procedure For Servicing

    Fault Reason Solution 3. SAFETY PRECATIONS FOR SERVICING engine oil is not enough. Fill engine oil Engine stops because of low oil Badness oil switch Replace switch 1. The installation and maintenance work should be operated by professional pressure. maintainer. Engine air cleaner wall up Replace filter 2.

  • Page 15: Warm-Up Procedure

    CAUTION 4. WARM-UP PROCEDURE The usage of the battery It will explode to cause a severe accident if the battery used in a wrong way. 1. Check the fuel before every start. Remove the negative terminal when servicing the generator. 2.

  • Page 16: Starting-Up Procedure And Running

    5. STARTING-UP&RUNNING PROCEDURE 10. SIMPLIFIED TROUBLESHOOTING GUIDE This guide is intended to give brief information for troubleshooting with no testing 1. According to the step of 1-10, finish the starting-up procedure. or measuring instruments to check the unit. 2. Ensure voltmeter indicates normal, (single phase: 230V, three phase: 400V) However, testing and measuring instruments are required to diagnose parts and 3.

  • Page 17
    8. Load Daily check 1000 Check & service item CAUTION Clean the inner of the fuel tank. Replace the air cleaner element Do not start 2 or more machines simultaneously. Start them one by one. Do not use floodlight together with other machines. Check valve clearance.
  • Page 18: Stop Procedure

    5) Three-phase generating set 9. MALFUNCTION AND COUNTERMEASURES Balance three phases during the operation. Stop the engine for check if the tolerances exceed 20%. Be sure to keep the tolerance among three phases less than 20%. 1. Maintenance Schedule The load for each phase must below the rated load as well as the current must Check and clean replace less than rated current.

  • Page 19: The Functions Of The Digital Panel

    8. ELECTRIC APPLIANCE 7. THE FUNCTIONS OF THE DIGITAL PANEL Electric appliance particularly motor-driven equipment will produce very high current PVC Label (Single-phase) while starting, the below table provides the reference for connecting these apparatus to the generator set. WATTAGE EXAMPLE TYPICAL TYPE…

  • Page 20
    OUTPUT CURRENT: indicating generator current Three-phase current: Indicating generator current. Single phase power: Indicating generator power. VOLTAGE: indicating generator voltage Generator voltage: Indicating generator voltage. LONG-RANGE CONTROL: indicating long-range control using if or not Generator running: Indicating the existence of electrical power. RUNNING: indicating electric power exist if or not Running trouble: Indicating running trouble, check it according to the code map list.

Инструкция в формате — PDF

Количество страниц — 24 страницы

Размер — 1.6 МБ

Доступно — Бесплатное скачивание

Доступно — Онлайн чтение

Электроагрегат дизельный 

KDE12EA3     KDE12EA 

KDE12STA3  KDE12STA   

Предыдущая страница

Следующая страница

Оглавление инструкции

  • Страница 1 из 25

    Электроагрегат дизельный KDE12EA3 KDE12EA KDE12STA3 KDE12STA

  • Страница 2 из 25

    ВВОДНАЯ ЧАСТЬ. Поздравляем Вас и благодарим за покупку агрегата KIPOR. Наша цель – предложить покупателям высококачественный дизельный генератор для удовлетворения их потребностей, и мы убеждены, что вы сделали правильный выбор. В данном руководстве, посвященном в основном вопросам эксплуатации

  • Страница 3 из 25

    СОДЕРЖАНИЕ. 1. ОСНОВНЫЕ ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ И ДАННЫЕ………………………4 2. ПОДГОТОВКА К ЭКСПЛУАТАЦИИ……………………………………………………………….5 3. МЕРЫ ПРЕДОСТОРОЖНОСТИ ПРИ ОБСЛУЖИВАНИИ………………………………..9 4. ПРОГРЕВ

  • Страница 4 из 25

    4

  • Страница 5 из 25

    5

  • Страница 6 из 25

    6

  • Страница 7 из 25

    7

  • Страница 8 из 25

    8

  • Страница 9 из 25

    8) Проверьте отсутствие утечки воды и масла. Осмотрите агрегат полностью, откройте дверцу для того, чтобы убедиться в отсутствии утечки воды и масла. В случае выявления утечки обратитесь по вопросу техобслуживания к вашему поставщику KIPOR Убедитесь, что нагрузка не превышает допустимый уровень

  • Страница 10 из 25

    10

  • Страница 11 из 25

    11

  • Страница 12 из 25

    12

  • Страница 13 из 25

    13

  • Страница 14 из 25

    14

  • Страница 15 из 25

    15

  • Страница 16 из 25

    ¤ Обратитесь за консультацией к поставщикам KIPOR. 16

  • Страница 17 из 25

    17

  • Страница 18 из 25

    18

  • Страница 19 из 25

    19

  • Страница 20 из 25

    Обозначение неисправностей и их устранение _____________________________________________________________________________ Обознач. неиспр. на дисплее Дисплей не выдаѐт показаний P 01 P 02 P 03 Возможные причины неисправности Перегорел предохранитель Нет с контакта с замком электрической двери Нет

  • Страница 21 из 25

    P 08 Температура охлаждающей жидкости слишком высокая Снимите нагрузку с генератора, оставьте его работать на холостых оборотах до тех пор пока температура охлаждающей жидкости не упадѐт до нормы. Недостаточное количество охлаждающей жидкости Добавьте охлаждающую жидкость до нормы Индикатор

  • Страница 22 из 25

    22

  • Страница 23 из 25

    23

  • Страница 24 из 25

    www.kipor-power.ru

  • Страница 25 из 25

Перегрев Двигателя

Перерасход Топлива В Процессе Работы

Перегорание Обмотки Генератора

Сильно Стучит Двигатель

В Области Генератора Присутствует Запах Горелой Обмотки

Спад Энергии

Колеблется Скорость

Нет Выхода Электричества

Нет Сварочного Тока
Наряжение С Генератора Выходит , Сварочный Инвертор Включается , Перегрева Нет ,Ампераж И Дуга Регуляторы Работают На Экране Пишет Ампераж , А На Кабеля Невыходит Ни Масса Ни Фаза ,- В Чем Проблема С Инвертором , Где Искать В Первую Очередь.?

Генератор Новый. Еще Не Работал Не Заводится Нет Искры. Свеча Рабочая

Генератор Kipor Kge12E
Большой Ток. 270-290V Как Исправить На 220V

Не Добавляет Обороты При Сварке
При Работе В Режиме Сварки Не Поднимает Обороты, В Чем Причина

Дымит Двигатель
Сильный Дым Из Выхлопной Трубы

Кратон Gg 095
Как Натянуть Пружину Стартера Если Порвалась Верёвка В

Через 20 Мин. Автоматика Дизеля Останавливает Его По Аварии: Напряжение По Трем Фазам.

Авария По Напряжению По 3М Фазам

Не Заводится Двигатель
Пол Года Не Работал, Подсоединил Аккумулятор, Вращает Стартер, Двигатель Не Запускается!

Нет Искры На Свече
Работал, Закончился Бензин, Незаводиться Проверили Пропала Искра

Большие Обороты
Большие Обороты На Холостом Ходу

Не Запускается Установка При Нажатии На Кнопку Пуск.
Работала Слетела Минусовая Клемма, Установка Перестала Работать , При Нажатии Кнопки Пуск Запуск Установки Не Происходит.

Глохнет
Заводится Хорошо, Но Через Минуту Глохнет

После Запуска Двигателя Выключается
После Запуска Двигателя, При Нагрузке Самопроизвольно Выключается. На Мониторе Высвечивается Значек Sos И Аккумулятор.

Зарядка Аккумулятора
Аккумулятор Садится, Не Заряжается. Не Работает Без Аккумулятора

Не Работает Соленоид Воздушной Заслонки
При Запуске С Дистанционного Пульта Не Закрывается Воздушная Заслонка

Не Работает Соленоид Воздушной Заслонки
При Запуске С Дистанционного Пульта Не Закрывается Воздушная Заслонка

Глохнет
После Запуска В Процессе Работы Снимаю Клемму С Аккумулятора И Генератор Глохнет

Невыдаёт Стабильные 220 Иольт
Полетел Стабилизатор Напрения

Понравилась статья? Поделить с друзьями:
  • Дигоксин таблетки инструкция по применению цена отзывы аналоги кому прописывают
  • Дизельная горелка lamborghini eco 8 инструкция
  • Дигоксин таблетки инструкция по применению и для чего дозировка взрослым
  • Дигоксин фармлэнд инструкция по применению
  • Дигоксин таблетки инструкция по применению взрослым и для чего назначают взрослым