Compex ReadyLINK DS2216 Quick Install Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

«Quick Install Guide»

Compex

16-Port All 10/100

Switch

DS2216

Version 1.2

loading

Related Manuals for Compex ReadyLINK DS2216

Summary of Contents for Compex ReadyLINK DS2216

  • Page 1
    “Quick Install Guide” Compex 16-Port All 10/100 Switch DS2216 Version 1.2…
  • Page 2
    DS2216 Power 100M Half Trunking Priority Default Link /Act 12 13 15 16 Speed /Col Uplink Mode Figure 1: Front Panel View of DS2216 9 10 11 Power 100M Half Trunking Priority Default Link /Act 10 11 14 15 16 Speed /Col Mode…
  • Page 3: Table Of Contents

    • How to force a certain port to 10Mbps speed and Half-duplex mode ………………….. 10 • How to set up and connect Compex DS2216 for trunking ….12 • How to enable and select trunking ports ……….13 • How to enable priority mode for a port……….14 •…

  • Page 4: Technical Support For French Version

    Warranty Card for English Version …………I Warranty Card for German Version ……….. II Warranty Card for Russian Version………..III Warranty Card for French Version ………… IV Technical Support for English Version……….. TS-1 Technical Support for German Version ……… TS-2 Technical Support for Russian Version ………. TS-3 Technical Support for French Version ………..

  • Page 5: Introduction

    “Quick Install Guide” Compex 16-Port All 10/100 Fast Ethernet Switch DS2216 1. Introduction The key features of the Compex 16-Port All 10/100 Fast Ethernet Switch DS2216 are as follows • Each port supports 10Base-T and 100Base-TX connection through auto-negotiation •…

  • Page 6: Panel Features

    Trunking LED Select to enable/disable and select trunking ports Priority LED Select to set/reset/port priority. Default LED Select to reset switch to factory default setting. Power Socket Flexible power input (range 100-250VAC, 0.5A, 47-63Hz) Compex 16-Port All 10/100 Switch English DS2216…

  • Page 7
    • 10/100 N-Way Auto-Negotiation or Forced Mode By default, Compex DS2216 is configured to auto-negotiate for a highest possible operation mode between two nodes. Alternatively, the users are able to manually configure the speed (10/100Mbps) and the transmission mode (full/half duplex) of the ports.
  • Page 8: Specifications

    • Environment Operating Temperature: 0°C to 50°C Requirements Storage Temperature: -20°C to 70°C Operating Humidity: 10% to 80% RH Storage Humidity: 5% to 90% RH [RH = Relative Humidity] • MAC Address Table Compex 16-Port All 10/100 Switch English DS2216…

  • Page 9: Installation Of Compex Ds2216

    Physical Dimension 302mm x 123mm x 53mm (L x D x H) 5. Installation of Compex DS2216 Compex DS2216 can be installed as a desktop unit. Below list the installation steps. 1. Unpack the unit. 2. Choose a location near the devices to be connected and close to an electrical outlet.

  • Page 10: Implementation

    7. Buttons and LEDs Feature Description • Button operations There are two buttons on Compex DS2216 panel, “Set” and “Mode”. They are for setting and resetting enhanced functions. Two function groups, namely Status LED group and Option Mode LED group, can be selected from the Mode button:…

  • Page 11
    — Half: Set/reset/view pre-set duplex mode for all ports. — Trunking: Set/reset/view pre-set port trunking group(s). — Priority: Set/reset/view pre-set priority mode for all ports. — Default: Reset all ports configuration to factory defaults. English Compex 16-Port All 10/100 Switch DS2216…
  • Page 12: How To View All Active Ports Link/Act Status

    Full-Duplex mode. Those port LEDs not lighted up are either inactive or not connected. If there are active ports but their LEDs did not light up, then they are connected at Half-Duplex mode. Compex 16-Port All 10/100 Switch English DS2216…

  • Page 13: Advanced Configuration On Compex Ds2216

    8. Advanced Configuration on Compex DS2216 • How to force a certain port to 100Mbps speed and Half or Full- duplex mode This is a 2 steps operation. Note To configure a port to auto-negotiation mode, turn OFF that port LED in both 100M and Half mode setup.

  • Page 14: Mode

    LED for that port number you want to set. If it is not lighted up it is already in 10Mbps mode. Do nothing. Setup is completed. If it lights up, go to (2b) to toggle to 10Mbps mode. Compex 16-Port All 10/100 Switch English DS2216…

  • Page 15
    Forced to 100Mbps speed and Half-Duplex mode Forced to 10Mbps speed and Half-Duplex mode Forced to 100Mbps speed and Full-Duplex mode Reset to normal auto-negotiation mode Table 1: Force Port Speed and Duplex mode English Compex 16-Port All 10/100 Switch DS2216…
  • Page 16: How To Set Up And Connect Compex Ds2216 For Trunking

    100 meters long. 3. Connect them up as shown below. Assuming 4 ports group trunking is selected. Compex DS2216 unit one uses ports from Group 1 and Compex DS2216 unit two uses ports from Group 2. Compex DS2216 Unit One…

  • Page 17: How To Enable And Select Trunking Ports

    See [Table2 – Single Trunk Grouping] and [Table 3 – Dual trunks combinations] below. Trunking Trunk Ports Speed Active Ports Group Group 1 400Mbps 2,10 600Mbps 2,9,10 800Mbps 1,2,9,10 Group 2 400Mbps 7,15 600Mbps 7,8,15 800Mbps 7,8,15,16 Table 2: Single Trunk Grouping English Compex 16-Port All 10/100 Switch DS2216…

  • Page 18: How To Enable Priority Mode For A Port

    Table 3: Dual Trunks Combinations • How to enable priority mode for a port Compex DS2216 supports advanced traffic priority features. It provides two levels of priority: normal and high priority. Packets in high priority mode will arrive sooner at the destination MAC address.

  • Page 19: How To Set Default Mode

    2. Now press the Set button and hold it down for about 3 seconds until all ports LEDs flash once. Now the switch is restore to Factory Default Setting. The factory default setting of Compex DS2216 is No trunking, Normal Priority, each port runs in Auto-Negotiation mode. •…

  • Page 20: Troubleshooting

    9. Troubleshooting LED Indicators The LEDs of Compex DS2216 can function as useful troubleshooting aids. If Power LED does not light up, check that: • Plug/cord is properly inserted into the socket. • The ON/OFF switch is turned ON. If LINK/ACT LED does not light up, check that: •…

  • Page 21: German Language

    Compex, Inc. may make improvements and/or changes to the product and/or specifications of the product described in this guide, without prior notice. Compex, Inc. will not be liable for any technical inaccuracies or typographical errors found in this guide. Changes are periodically made to the information contained herein and will be incorporated into later versions of the guide.

  • Page 22: Warranty Registration Card

    [M-0088-V2.3C] You can register via Internet at: http://www.cpx.com or http://www.compex.com.sg Or E-mail: support@compex.com.sg with the following information: To activate the warranty, please complete this card and return to Compex within ninety (90) days of purchase date. Product: Purchase Date: Revision:…

  • Page 23
    +49 (0) 6074 — 93974 (24-hour access) Support Email: readylink@compex.com.sg Asia, Australia, New Zealand, Middle East and the rest of the World ! Write Compex Systems Pte Ltd 135, Joo Seng Road #08-01, PM Industrial Building Singapore 368363 » Call Tel: (65) 6286-1805 (8 a.m.-5 p.m.
  • Page 24
    Manual Number: M-0313-V1.2C M-0313-V1.2G M-0313-V1.2R M-0313-V1.2F Version 1.2 , 2002…

  • Главная
  • Статьи и справочные материалы
  • Архив до 2010 года
  • управляемый коммутатор DynaStack DS2216

DS2216, управляемый коммутатор 10/100Mbps, 16 портов

DynaStack DS2216 фирмы Compex обеспечивает идеальное решение для настольного коммутатора. Расширенные свойства 16 портового коммутатора, для скоростей 10/100 Mбит/с, с поддержкой Fast Ethernet, обычно используются в высокопроизводительных коммутаторах. Это установка приоритета, объединение портов (транк) и установка принудительного режима работы. Вместе с дополнительными кнопками включения питания (PowerButtons), эти свойства размещены теперь в виде сенсоров на передней панели переключателя. DynaStack DS2216 осуществляет полную, при отсутствии коллизий, пропускную способность во всем диапазоне и, также, способен к предоставлению возможности каскадирования с помощью 4 портов между двумя модулями DS2216. Связанные порты могут быть сконфигурированы с приоритетом, который может быть затребован любым, критичным к полосе пропускания, программным приложением. При работе в принудительном режиме, DS2216 может позволить работу с одновременным использованием обеих скоростей и дуплексного режима, соответственно сконфигурированными, в отличие от наиболее простых переключателей, которые работают в режиме автоматической установки связи между двумя узлами.

Характеристики:

  • 16 10/100 Mbps портов
  • Поддержка Full duplex / Half duplex
  • Автосогласование портов 10 и 100 Mbps
  • Поддерживает до 16K MAC адресов
  • Макс.дистанция: 100Base-TX — до 100 м, UTP Cat 5 кабель. 10Base-T — до 100 м, UTP Cat 3,4,5 кабель.
  • LED индикация портов (питание, full/half duplex, состояние связи, скорость и активность соединения)
  • Возможность установки приоритета и принудительного режима работы
  • Поддержка 4-х портового транка
  • Порт UpLink для соединения с другим коммутатором или концентратором
  • «Store-and-forward» технология, безошибочная передача данных
  • Фильтрация динамических адресов
  • Встроенный блок питания

Информация для заказа:

Партномер Описание
DSR2216 Коммутатор 16×10/100Base-TX, 19″

Подпишитесь на скидки
и новости компании



Коммутатор (switch) поступил в ремонт с заявленным дефектом «не работает, лампочки на передней панели мигают». После вскрытия корпуса коммутатора было установлено, что в качестве источника питания в нём используется модуль YCL NAD-32 DC OUTPUT +3.3V/3A +5V 1A (маркировка платы — PCB214), вырабатывающий напряжение питания +3.3V (точнее — +3.3V и +5V, но последнее — не используется основной платой устройства), выполненная на основе микросхемы ШИМ-контроллера UC3842AN. В ходе проверки, на этой плате выявлен неисправный (внешне «вздутия» у него нет, остаточная ёмкость около 600uF) электролитический конденсатор C3 1000uF-25V (тип — Gloria +85°C), стоящий непосредственно на выходе однополупериодного выпрямителя. После замены данного конденсатора, работоспособность коммутатора была восстановлена.

P.S. Данный коммутатор поступил в ремонт вторично, с тем же заявленным дефектом. На этот раз оказались неисправными следующие элементы: микросхема ШИМ-контроллера UC3842AN, полевой транзистор Q1 2SK2141 (маркировка  — K2141), электролитический конденсатор выпрямителя сетевого напряжения C6 33uF-400V (тип — J.J ® 105°C), резисторы R3 10 Ω/0.25W и R4 0.9 Ω/2W, сетевой предохранитель F1 T2AL250V. После замены всех данных элементов, работоспособность коммутатора была восстановлена.

Читайте также :

» Материнская плата FUJITSU SIEMENS COMPUTERS D2581-A12

Материнская плата выполнена на основе чипсета INTEL iQ33 и предназначена для использования с процессорами имеющими сокет LGA775, она…

» Материнская плата GIGABYTE GA-8I945GZME-RH

(REV:1.0) выполнена на основе чипсета INTEL 945GZ, и предназначена для использования с процессорами, имеющих Socket LGA775. Она поступила в ремонт с…

» Монитор PHILIPS 150B4

Монитор поступил в ремонт с заявленным дефектом «не включается». Основные модули монитора: LG.PHILIPS LCD LS150X05 (A4); скалера (WK:0325) 3138 103 5689.2; …

» Блок питания microlab M-ATX-360W (3)

Блок питания поступил в ремонт с заявленным дефектом «не работает». В ходе проверки, на WAN NIEN VER:1.3 0301C, были выявлены неисправные…

» Ноутбук lenovo 3000 C200

поступил в ремонт после пролития жидкости в район кнопок управления и верхней части клавиатуры. После разборки ноутбука, в ходе…

1

9

10

11

Power

100M

Half

Trunking

Priority

Default

Link

/Act

Set

9

10

11

12 13

14

15 16

Speed

FDX

/Col

1

2

3

4

5

6

7

8

Mode

2

3

Figure 1: Front Panel View of DS2216

6

9 10 11

Power

100M Half

Trunking

Priority

Default

Link

/Act

Set

9

10 11

12

13

14 15 16

Speed

FDX

/Col

1

2

3

4

5

Mode

7

8

Figure 2: Front Panel View of DS2216 (Section)

100-250VAC 0.5A 47-63Hz

Figure 3: Back Panel View of DS2216

12

13

14

15

16

Uplink

4

12

13

9

10

11

6

7

8

This device complies with

Part 15 of the FCC Rules.