Фильтр для бассейна intex sf80220 2 инструкция

Model SF80220-2

220-240 V~, 50 H

Z

Model SF70220-2

220-240 V~, 50 H

Z

Model SF60220-2

220-240 V~, 50 H

Z

MAX. WATER TEMPERATURE 35°C

For illustrative purposes only.

Don’t forget to try these other fine Intex products: pools, pool

accessories, inflatable pools and in-home toys, airbeds and boats

available at fine retailers or visit our website.

Due to a policy of continuous product improvement, Intex reserves

the right to change specifications and appearance, which may

result in updates to the instruction manual without notice.

®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous

licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen

Ländern der Welt in Lizenz von/Intex Marketing Ltd. to/à/a/an Intex Development Co. Ltd., G.P.O Box 28829, Hong

Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801 • Distributed in the European Union by/Distribué

dans l’Union Européenne par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union durch/Intex Trading

B.V., Venneveld 9, 4705 RR Roosendaal – The Netherlands

www.intexcorp.com

(342IO) SAND FILTER PUMP ENGLISH 7.5″ X 10.3″ PANTONE 295U 06/11/2018

IMPORTANT

SAFETY RULES

Please read, understand, and follow all

instructions carefully before installing

and using this product. Keep for future

reference.

, 250 W, Hmax 5 m Hmin 0.19 m IPX4

, 450 W, Hmax 7.5 m Hmin 0.19 m IPX4

, 550 W, Hmax 7.5 m Hmin 0.19 m IPX4

©2018 Intex Marketing Ltd. — Intex Development Co. Ltd. — Intex Recreation Corp.

All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle

Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/

Gedruckt in China.

English

342A

342-*A*-R0-1906

Intex SF80220-2 Water Pump PDF User Guides and Manuals for Free Download: Found (1) Manuals for Intex SF80220-2 Device Model (Owner’s Manual)

More Water Pump Device Models:

  • STM

    594 TITAN

    ItemNo. PartNumber Descripon12345601‐004612502‐000098603‐000825704‐000823505‐000827006‐0008272LeverPin—Steel—3/8”x1‐3/4”CoerPinLeverLink—CastIronPlungerPin—SteelPackingGland—CastIronGlandPac …

    594 TITAN Water Pump, 2

  • Grundfos

    Unilift CC 5 M1

    Service instructionsUnilift CC1 / 896581224 0406GB8Contents1. Identification …………………………………………………………………………………………………………………… 21.1 Nameplate ………………………………………………………………………………….. …

    Unilift CC 5 M1 Water Pump, 8

  • Lochinvar

    BLT2026

    LTV VALVE APPLICATION INSTRUCTIONS FOR LOW TEMPERATURE PROTECTIONCOPPER-FIN AND POWER-FIN MODELS CB 495 — 2066 / CH 401 — 2071 AND PB 501 — 2000INS7238 Rev CKit components:VAL30000 — 1 1/2″ VALVEModels: CB 45 — 500• VAL20000 1 1/2″ LTV Valve • INS7238 Instruction Sheet VAL3048 — 2″ VALVEMod …

    BLT2026 Water Pump, 8

  • EBARA

    SB3

    SB3Stampato su carta riciclataNessun albero è stata abbattuto Marchio “Angelo Blu”Printed on recycled paperNo tree was fallenLabel “Blue Angel”Imprimé sur papier recycléAucun arbre n’a été abattu Label “Ange Bleu”Auf Recyclingpapier gedrucktKein Baum wurde gefällt Marke “Blauer Engel”Impreso en …

    SB3 Water Pump, 23

Recommended Documentation:

SETUP INSTRUCTIONS (continued)

Sand loading:

IMPORTANT: Use No. 20 silica sand or glass sand with particle size range 0.45 to 0.85 mm

(0.018 to 0.033 inches) and a Uniformity Coefficient less than 1.75.

Only use the filter media specified by the manufacturer.

NOTE: Before loading the tank with sand, ensure the center pipe hub assembly is

securely in place at the bottom of the tank, and vertically centered inside the tank.

1.

Place the sand shield (6) over the top of the center pipe. Pour the sand into the tank at

a slow rate (see drawing 15).

2.

Fill the tank approximately half way, remove the sand shield (6) from the top (see

drawing 16).

6

3.

Evenly distribute the sand inside the tank, then fill the tank with some water to provide a

cushioning effect when the remaining sand is poured in. This prevents the center pipe hub

(7) from excessive shock (see drawing 17). Place the sand shield (6) back and continue to

pour the sand into the tank.

4.

Sand shall be filled between the «MAX» and «MIN» marked gauge on the center pipe (see

drawings18).

MAX

MIN

5.

Remove the sand shield (6) (see drawing 16) and evenly spread and level out the sand by

hand (see drawing 17).

6.

Wash away all sand around the top edge of the tank.

SAVE THESE INSTRUCTIONS

(342IO) SAND FILTER PUMP ENGLISH 7.5″ X 10.3″ PANTONE 295U 06/11/2018

15

17

7

English

6

7

MAX

MAX

MIN

MIN

MAX

MIN

Page 10