Fleck 9100 sxt инструкция на русском

Pentair Fleck 9100 - SXT User Manual

  1. Manuals
  2. Brands
  3. Pentair Manuals
  4. Control Unit
  5. FLECK 9100 SXT
  6. User manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

loading

Related Manuals for Pentair Fleck 9100 — SXT

Summary of Contents for Pentair Fleck 9100 — SXT

  • Page 1
    Fleck 9100 — SXT…
  • Page 2: Original Settings

    User Guide Fleck 9100-SXT Original settings Installation settings Installation no. Controller type Valve type Valve serial no. Resin type Resin volume [°tH] [°tH] Inlet water hardness Outlet water hardness Tank size Tank capacity °tH] [kg] Brine tank size Salt quantity per regeneration Hydraulic settings Injector size BLFC…

  • Page 3
    User Guide Fleck 9100-SXT Maintenance record book Date¹ Description² Name³ Signature⁴ No. FR 1 Date Datum Fecha Data Datum 2 Description Beschreibung Descripción Descrizione Beschrijving 3 Nom Name Nombre Nome Naam 4 Signature Unterschrift Firma Firma Handtekening Ref. MKT-UG-008 / A — 27.10.2016 4 / 28…
  • Page 4: Limitation Of Liability

    Pentair shall not accept any liability for any loss or damage of profits, revenues, use, production, or contracts, or for any indirect, special or consequential loss or damage whatsoever. Please refer to the Pentair List Price to know more about terms and conditions applicable to this product.

  • Page 5: Technical Specifications

    User Guide Fleck 9100-SXT Safety 2.1. Safety tags location MADE IN XXXXXX Model By Pentair International LLC 123456789012345678 Model: Part number P/N: 123456789012345678 For Timer Only Electrical rating 1234567 12345678 1234567 1234567 Serial number : 123456789012345678901234 Serial Note: Ensure that the safety tags on the device are completely legible and clean. If necessary, replace them with new tags and put them in the same places.

  • Page 6: Description And Components Location

    User Guide Fleck 9100-SXT 3.3. Description and components location Drain Display Brine Down button Mixing device Up button Meter Regeneration button Inlet Outlet 3.4. By-passing If the system is equipped with a bypass and if a problem occurs, turn the valves to bypass the system as shown in the picture below.

  • Page 7: Operation

    User Guide Fleck 9100-SXT Feed Water Hardness Note: Determine the feed water hardness in °tH. Adjust the water hardness with Press to validate the selection and advance to the next parameter. Fixed reserve capacity Note: Determine the reserve capacity in Liter. Adjust the reserve capacity with Press to validate the selection.

  • Page 8
    www.fleck-russia.ru…

  • Page 1
    Model 2850 Service Manual IMPORTANT: Fill in Pertinent Information on Page 3 for Future Reference…
  • Page 2: Table Of Contents

    Table of Contents Job Specification Sheet……………………….3 General Commercial Pre-Installation Check List………………..4 3200 Timer Setting Procedure……………………..5 3210 Timer Settings…………………………. 6 3200 & 3210 Timer Series Regeneration Cycle Program Setting Procedure…………7 3200 Timer Assembly……………………….. 8 3200 Timer Assembly Parts List……………………..

  • Page 3: Job Specification Sheet

    Job Specification Sheet *Job No. *Model No. *Water Test *Capacity Per Unit *Mineral Tank Size Diameter Height *Brine Tank Size & Salt Setting per Regeneration *2850 Control Valve Specifications 1. Type of Timer A. 7 Day or 12 Day B. *625 to 10,625 Gallon Meter or *3,125 to 53,125 Gallon Meter or *Other C.

  • Page 4: General Commercial Pre-Installation Check List

    General Commercial Pre-Installation Check List WATER PRESSURE: A minimum of 25 pounds of water pressure is required for regeneration valve to operate effectively. ELECTRICAL FACILITIES: A continuous 115 volt, 60 Hertz current supply is required. Make certain the current supply is always hot and cannot be turned off with another switch. EXISTING PLUMBING: Condition of existing plumbing should be free from lime and iron buildup.

  • Page 5: 3200 Timer Setting Procedure

    3200 Timer Setting Procedure How To Set Days On Which Water Conditioner Is To Regenerate: Rotate the skipper wheel until the number “1” is at the red pointer. Set the days that regeneration is to occur by slid- ing tabs on the skipper wheel outward to expose trip fin- gers.

  • Page 6: 3210 Timer Settings

    3210 Timer Settings Typical Programming Procedure How To Manually Regenerate Your Water Condi- tioner At Any Time: Calculate the gallon capacity of the system, subtract the necessary reserve requirement and set the gallons Turn the manual regeneration knob clockwise. available opposite the small white dot on the program This slight movement of the manual regeneration wheel gear.

  • Page 7: 3200 & 3210 Timer Series Regeneration Cycle Program Setting Procedure

    3200 & 3210 Timer Series Regeneration Cycle Program Setting Procedure (Brine Tank Refill Separate from Rapid Rinse) How To Set The Regeneration Cycle Program: The regeneration cycle program on your water condi- tioner has been factory preset, however, portions of the cycle or program may be lengthened or shortened in time to suit local conditions.

  • Page 8: 3200 Timer Assembly

    3200 Timer Assembly Page 8…

  • Page 9: 3200 Timer Assembly Parts List

    3200 Timer Assembly Parts List 1….1….. 13870….Housing, Timer, 3200 2….1….. 13011….Arm, Cycle Actuator 3….1….. 40096-24….Dial 12AM Regen Assy, Black 40096-02….Dial 2AM Regen Assy, Black 4.

  • Page 10: 3210 Timer Assembly

    3210 Timer Assembly Page 10…

  • Page 11: 3210 Timer Assembly Parts List

    3210 Timer Assembly Parts List Item No. Quantity Part No. Description 1….1….13870-01….Housing Assembly, Timer, 3210 2….1….13802…….Gear, Cycle Actuator 3….1….40096-24….Dial 12AM Regen Assy, Black 40096-02….Dial 2AM Regen Assy, Black 4….1….13886…….Knob, 3200 5.

  • Page 12: Control Valve With 1700 Injector Assembly

    Control Valve with 1700 Injector Assembly Page 12…

  • Page 13: Control Valve With 1700 Injector Assembly Parts List

    Control Valve with 1700 Injector Assembly Parts List Item No. Quantity Part No. Description 1….1….. 16250…….Valve Body, 2850 16250-01….Valve Body, 2850, Machd 2….6….. 16101…….Seal, 2850 3….5….. 16638…….Spacer, 9500/2850 4….1….. 16092…….Piston, 2850 5.

  • Page 14: Environmental Power Head Assembly

    Environmental Power Head Assembly Page 14…

  • Page 15: Environmental Power Head Assembly Parts List

    Environmental Power Head Assembly Parts List Item No. Quantity Part No. Description 1…..1….. 18697-15…….. Backplate, Hinged 2……….. 3200 Clock Timer Assy… 3200 Clock Timer Assy 3200 Meter Timer Assy… 3200 Meter Timer Assy 3…..1….. 41543……..Motor, Drive, 115V, 50/60 Hz 41544.

  • Page 16: Control Drive Assembly

    Control Drive Assembly Page 16…

  • Page 17: Control Drive Assembly Parts List

    Control Drive Assembly Parts List Item No. Quantity Part No. Description 1….1….. 40264…….Backplate, SS/SVO, w/T Screws — 3200 7 Day 2….1…………Timer — 3200 12 Day — 3210 Meter 3….1….. 40084-12….Power Cord, 12’ US, Round, 120V Sys 5, 6, 7 & 2900/3150/3900 #4 4.

  • Page 18: Manual Drive Assembly & Parts List

    Manual Drive Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 12593…….Backplate, Manual 2….1….. 12592…….Bracket, Lever Position 3….1….. 12596…….Screw, Spec Mach, 1/4 — 20 x 1/2 4.

  • Page 19: 1600 Brine System Assembly & Parts List

    1600 Brine System Assembly & Parts List Item No. Quantity Part No. Description 1….1……10328……Fitting, Elbow, 90 Deg. 1/4 PT x 3/8T 2….1……12767……Screen, Brine 3….2……10332……Fitting, Insert, 3/8 4….

  • Page 20: 1700 Brine System Assembly

    1700 Brine System Assembly Page 20…

  • Page 21: 1700 Brine System Assembly Parts List

    1700 Brine System Assembly Parts List Item No. Quantity Part No. Description 1….1….. 14792…….Plug, End, Brine Valve 2….1….. 13201…….Quad Ring, -020 3….1….. 12085…….Washer, Flow, 1.2 GPM 12086…….Washer, Flow, 1.5 GPM 12087…….Washer, Flow, 2.0 GPM 12088…….Washer, Flow, 2.4 GPM 12089…….Washer, Flow, 3.0 GPM 12090…….Washer, Flow, 3.5 GPM…

  • Page 22: 1710 Brine System Assembly & Parts List

    1710 Brine System Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 41202…….Brine Valve, 1700, Plastic, Top 2….1….. 14785-01….Retainer, Flow Control 3….1….. 14811…….O-Ring, -210, 560CD, Brine 4….1….. 14798…….Spacer, 1700, Brine 5.

  • Page 23: 1600 Service Valve Operator Assembly & Parts List

    1600 Service Valve Operator Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 11749…….Guide, Brine Valve Stem 2….1….. 10250…….Ring, Retaining 3….1….. 10249…….Spring, Brine Valve 4….1….. 12550…….Quad Ring, -009 5.

  • Page 24: 2300 Safety Brine Valve Assembly & Parts List

    2300 Safety Brine Valve Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 60027-FFA….Safety Brine Valve Body, 2300 Fitting Facing Arm 60027-FFS….Safety Brine Valve Body Fitting Facing Stud 2….1….. 60028-30….Float Assy, 2300, 30”, Blue/White 60026-30SAN..Float Assy, 2350, 30”, HW 3.

  • Page 25: 2310 Safety Brine Valve Assembly & Parts List

    2310 Safety Brine Valve Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 60014…….Safety Brine Valve Assy, 2310 2….1….. 60068…….Float Assy, 2310, w/30” Rod ……….60026-30….Float Assy, 2350, 30” Red/Wht 3.

  • Page 26: 2350 Safety Brine Valve Assembly & Parts List

    2350 Safety Brine Valve Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 60038…….Safety Brine Valve, 2350 1A….1….. 61024…….Actuator Assy, 2350 Brine 2….1….. 60026-30….Float Assy, 2350, 30” Red/Wht ……….60026-30SAN..Float Assy, 2350, 30”, HW 3.

  • Page 27: 1″ Meter Assembly & Parts List

    1” Meter Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 14959…….Body, Meter, 2750 2….1….. 13882…….Post, Meter Impeller 3….1….. 13509…….Impeller, Meter 4….1….. 13847…….O-ring, -137, Std/560CD, Meter 5A….

  • Page 28: 1/2″ Meter Assembly & Parts List

    1 1/2” Meter Assembly & Parts List Item No. Quantity Part No. Description 1….1….. 17569…….Body, Meter, 2850/9500 2….1….. 13882…….Post, Meter Impeller 3….1….. 13509…….Impeller, Meter 4….1….. 13847…….O-Ring, -137, Std/560CD, Meter 5A….

  • Page 29
    Notes Page 29…
  • Page 30: Service Assemblies

    Service Assemblies 24 Hour Gear Assemblies 60034-xx… 1700 Brine Valve Assy 19205….Gear Assy, 24 Hour, Silver, 5600, (Specify flow control 1.0 — 5.0) 12 A.M. 60604-xx… Model 1710 Brine Valve Assy 60519-02 Gear Assy, 3200 24 Hour 2 Times/. (Specify flow control 1.0 — 5.0) Day, w/Silver Label 60519-03.

  • Page 31
    Service Assemblies 61560-01… Meter Assy, In-Line, w/1” NPT Service Equipment Plstc Connector 16174….Silicone, 2 oz. Tube 61560-07… Meter Assy, In-Line, w/1” NPT 16586-8….. Silicone, Dow #7 8 Lb Brass Connector 16516….Stuffer Assy, 2850/9500 61560-09.
  • Page 32: Service Instructions

    Service Instructions Problem Cause Correction 1. Water conditioner fails to A. Electrical service to unit has A. Assure permanent electrical service regenerate. been interrupted (check fuse, plug, pull chain, or switch) B. Timer is defective. B. Replace timer. C. Power failure. C.

  • Page 33: General Service Hints For Meter Control

    Service Instructions Problem Cause Correction 8. Softener fails to draw brine. A. Drain line flow control is A. Clean drain line flow control. plugged. B. Injector is plugged. B. Clean injector C. Injector screen plugged. C. Clean screen. D. Line pressure is too low. D.

  • Page 34: Water Conditioner Flow Diagrams

    Water Conditioner Flow Diagrams 1 Service Position Hard water enters unit at valve inlet and flows down through the mineral in the mineral tank. Conditioned water enters center tube through the bottom distributor, then flows up through the center tube, around the piston, and out the outlet of the valve. 2 Backwash Position 3 Brine Position Hard water enters unit at valve inlet, flows through…

  • Page 35
    Water Conditioner Flow Diagrams 4 Slow Rinse Position Hard water enters unit at valve inlet, flows up into injector housing and down through nozzle and throat, around the piston, down through mineral, enters center tube through bottom distributor, flows up through center tube, around piston and out through drain line. 6 Brine Tank Refill Position 5 Rapid Rinse Hard water enters unit at valve inlet, flows directly…
  • Page 36: Flow Data & Injector Draw Rates

    Flow Data & Injector Draw Rates Page 36…

  • Page 37: System #4 — Typical Single Tank Installation With Optional Meter

    System #4 — Typical Single Tank Installation with Optional Meter Page 37…

  • Page 38: System #5 Interlock — Typical Twin Tank Installation With Optional Meter Interlock And No Hard Water Bypass

    System #5 Interlock — Typical Twin Tank Installation with Optional Meter Interlock and No Hard Water Bypass Page 38…

  • Page 39: System #6 — Twin Series Regeneration Installatio Nwith A Remote Meter

    System #6 — Twin Series Regeneration Installation with a Remote Meter Page 39…

  • Page 40: System #7 — Twin Alternator Installation With A Remote Meter

    System #7 — Twin Alternator Installation with a Remote Meter Page 40…

  • Page 41: System #4 — Single Valve Regeneration Immediate And Delayed Valve Wiring

    System #4 — Single Valve Regeneration Immediate and Delayed Valve Wiring Page 41…

  • Page 42: System #4 — With Remote Starter Valve Wiring

    System #4 — with Remote Starter Valve Wiring Page 42…

  • Page 43: System #5 — Interlocked Regeneration Valve Wiring

    System #5 — Interlocked Regeneration Valve Wiring 40502-01_REVB 40502-02_REVB Page 43…

  • Page 44: System #6 — Series Regeneration Valve Wiring

    System #6 — Series Regeneration Valve Wiring 13632-01_REVK 13632-02_REVL Page 44…

  • Page 45: System #7 — Alternating Regeneration 230V / 3-Way Solenoid Output Valve Wiring

    System #7 — Alternating Regeneration 230V / 3-Way Solenoid Output Valve Wiring 19138-01_REVD 19138-02_REVD Page 45…

  • Page 46: System #7 — Alternating Regeneration 24V / 120V / 3-Way Solenoid Output Valve Wiring

    System #7 — Alternating Regeneration 24V / 120V / 3-Way Solenoid Output Valve Wiring 17727-01_REVD 17727-02_REVD Page 46…

  • Page 47
    Notes Page 47…
  • Page 48
    P/N 16510 Rev. F 02/06…
  • Комплектующие
  • Управляющие клапаны
  • Управляющие клапаны Fleck
  • Fleck 9100
  • Fleck 9100/1600 1″ SXT

Артикул: FL16655-01
Производитель: Pentair, USA

  • Описание
  • Характеристики
  • Инструкции

Управляющий клапан Fleck Fleck 9100/1600 1″ SXT — реагентный управляющий клапан, устанавливается на установки умягчения непрерывного действия. Тип работы — попеременный (маятниковый). Один корпус находится в режиме работы, другой в режиме регенерации или ожидания. Оснащен контроллером SXT, имеет встроенный расходомер 1″ — крыльчатка. Выход на регенерацию — по счетчику/таймеру. Материал проточной части — норил. Диаметр посадочной резьбы — 2,5″. Вход/выход — 1″. Дренажная линия — 1/2″. Тип солевой системы — 1600, диаметр реагентной линии — 3/8″.

Получить консультацию специалиста

Параметр

Описание

Материал исполнения  корпуса

Норил

Диаметры для подключения:

1”

-Вход, мм

25

-Выход, мм

25

-Дренаж, мм

12,7

Диаметр дистрибьютора (водоподъемной трубы)  , дюйм

1,05

Размер посадочной резьбы, дюймы

2,5

Тип посадки блока на корпус фильтра

верхняя

Номинальный расход воды, м3/ч

4,4

Максимальный расход воды, м3/ч

5,6

Контроллер:

Электронный контроллер SXT (регенерация по таймеру, по расходу воды)

Высота блока от верха корпуса фильтра, мм

160

Диапазон применения для корпусов фильтров, дюймы

6- 16

Характеристики электропитания

220В — 50Гц

Рабочее давление, Бар

1,8 — 8,5

Рабочая температура, градусы       

1 — 40

fleck 9100

Описание

Клапан управления Fleck 9100 идеальное решение для организации непрерывной работы системы умягчения воды. Клапан имеет высокую прочность и надежность.

Преимущества

  • Управление двумя фильтрами
  • Не восприимчив к коррозии
  • Полностью программируемые стадии регенерации
  • Оптимальная цена

Цена по запросу

В наличии

Краткие технические характеристики INFO

Материал Пластик
Рабочее давление 1,8 — 8,5 бар
Рабочая температура 1 — 43 °С
Сервисная производительность 4,0 м3
Обратная промывка 1,9 м3
Вход/выход 3/4″ или 1″
Посадочное отверстие 2,5″
Рекомендуемые диаметры фильтров 6 — 16″
Опции Upflow, Байпас, Подмес

Документация PDF

Москва, Красноармейская улица, д. 11 корпус 1

fleck.ru

fleck.ru

fleck.ru

Главная

Каталог

Управляющий клапан Fleck 9100/1600SXT/3/4″ (12″, 2/3.5/1)xxxxxxxxxxxx

Pentair FLECK

Клапан управляющий 9100/1600SXT/3/4″ (12″, 2/3.5/1)  

Подробнее

Цена действительна только для интернет-магазина и может отличаться от цен в розничных магазинах

Описание

Модель 9100 — прочный и надежный клапан из полимерного материала, армированного волокном. Он является коррозионно-стойким и устойчивым к ультрафиолетовому излучению. Модель 9100 может выполнять регенерацию сразу же, как только в этом возникает необходимость, обеспечивая непрерывную подачу умягченной воды даже во время регенерации. Идеально подходит для небольших коммерческих / больших бытовых систем, требующих использования двух корпусов. Использование 100 % емкости корпуса перед переключением на второй корпус экономит соль и воду.

Характеристики

Управление


с электронным управлением по расходу (дуплекс — переменное)

Ном.произв-сть (м³/ч)


4,0

Электропитание (В)


220-24B

Тип упаковки


Коробка

Температура воды (°С)


1 — 43

Давление на входе (бар)


1,8 — 8,5

Присоед.размер(ы)


1″


Наличие