RM-05

Remote mp with Zone Selector

loading

Related Manuals for Inter-m RM-05A

Summary of Contents for Inter-m RM-05A

  • Page 1
    RM-05 Remote mp with Zone Selector…
  • Page 2: Table Of Contents

    Contents Contents Welcome Warning……………………….1 Installation Environment……………………….2 Important Safety Instructions………………….2 Features ……………………….3 Accessories………………………..3 Operating Procedure ……………………3 Front Panel ……………………….4 Rear Panel ……………………….6 Applications ……………………….7 Block Diagram ……………………..8 Specifications ……………………..9 Service Procedures……………………….10 Schematic ………………………..10 Parts List ……………………….10 Variations and Options …………………..10 Warranty ……………………….10…

  • Page 3: Warning

    A personal welcome to you from the management and employees of Inter-M All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.

  • Page 4: Installation

    S3125A S3125A RM-05A…

  • Page 5: Features

    Highly sensitive condenser type Mic is used for clear broadcasting. — EXCLUSIVE USE FOR PAM-240A/360A, PCT-610/620 RM-05A is the dedicated remote control amplifier for PAM series, so it only can be used with PAM- 240A/360A, PCT-610/620. — MUTE FUNCTION FOR CHIME OUT Chime melody can be muted by simple operation.

  • Page 6: Front Panel

    Turn clockwise to increase and counter clockwise to decrease the microphone volume level. 3. POWER SWITCH Switches ON and OFF the microphone unit. 4. OUTPUT LEVEL METER Indicates the signal output level between –20dB and +10dB. 5. ZONE/CHANNEL LED INDICATOR Visual indication of the selected channel. RM-05A…

  • Page 7
    CHIME OFF CHIME ON CHIME OFF CHIME ON JUMPER1 JUMPER1 CHIME ON CHIME OFF 10. ALL ZONE LED INDICATOR Visual indication that all channels have been selected for broadcast. 11. ALL ZONE SELECTION SWITCH Selects all channels for broadcast. RM-05A…
  • Page 8: Rear Panel

    Rear Panel 1. REMOTE CONNECTION CABLE CONNECTOR Used to connect the RM-05A to the host amplifier PAM-240A/360A, PCT-610/620. * Refer to pin number as below You can use conveniently Remote Control (Speaker zone can be selected and chime can be operated)

  • Page 9: Applications

    REMOTE AMP WITH ZONE SELECTOR Applications Applications RM-05A…

  • Page 10: Block Diagram

    REMOTE AMP WITH ZONE SELECTOR Block Diagram Block Diagram MIC IN LEVEL TALK LEVEL CHIME POWER S/W DC 24V IN +18V REMOTE COM SW1~SW5 RM-05A…

  • Page 11: Specifications

    Impedance………………………Max 680Ω Sensitivity (0dB=1V/0/.1Pa at 1kHz) …………-45dB±4dB(0dB=1V/0.1Pa at 1kHz) Sensitivity Reduction………………….Within -3dB at 1.0V Current Consumption ……………………Max 0.5mA S/N Ratio ……………………..More than 55dB Standard Power Supply……………………DC 1.5V Weight Goose Neck……………………97g±10/0.2lb * Specifications and design subject to change without notice. RM-05A…

  • Page 12: Service

    To obtain specific warranty information and available service locations contact Inter-M directly(in Korea or the USA) or the authorized Inter-M Distributor for your specific country or region.

  • Page 13
    NOTE…
  • Page 14
    NOTE…
  • Page 15
    Inter-M, Ltd. (Korea) began operations in 1983. Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world. Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).

RM-05A Remote Amp with Zone Selector

Contents

Welcome

Warning………………………………………………………………………………………………………………………..

1

Installation

Environment……………………………………………………………………………………………………………………

2

Important Safety Instructions……………………………………………………………………………………………….

2

Features…………………………………………………………………………………………………………………………..

3

Accessories…………………………………………………………………………………………………………………….

3

Operating Procedure ………………………………………………………………………………………………………

3

Front Panel ……………………………………………………………………………………………………………………..

4

Rear Panel ………………………………………………………………………………………………………………………

6

Applications ……………………………………………………………………………………………………………………

7

Block Diagram ………………………………………………………………………………………………………………..

8

Specifications ………………………………………………………………………………………………………………….

9

Service

Procedures……………………………………………………………………………………………………………………

10

Schematic …………………………………………………………………………………………………………………….

10

Parts List ………………………………………………………………………………………………………………………

10

Variations and Options …………………………………………………………………………………………………

10

Warranty ………………………………………………………………………………………………………………………

10

Inter-M RM-05A User Manual

REMOTE AMP WITH ZONE SELECTOR

Welcomel

A personal welcome to you from the management and employees of Inter-M

All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.

We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.

Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK.

DO NOT REMOVE COVER (OR BACK).

NO USER-SERVICEABLE PARTS INSIDE.

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not expose the unit to rain or moisture.

This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.

Attentions: Pour prévenir les chocs électriques ne pas utiliser cette fiche polarisée avec un prolongateur, une prise de courant on une autre sortie de courant, sauf si les lames peuvent étre insérées à fond sans en laisser aucune partie à découvert.

*Do not install this equipment in a confined space such as a book case or similar unit.

*The apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus. *Worded: “WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.”

Service Instructions

*Worded: «Caution: These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.»

*Location: Instruction Manual.

NOTE : This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.

* It can be heated up if you use this product in closed box or ill-ventilated place.

RM-05A 1

REMOTE AMP WITH ZONE SELECTOR

InstallationI t ll ti

Environment

Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

1.Read these instructions.

2.Keep these instructions.

3.Heed all warnings.

4.Follow all instructions.

5.Do not use this apparatus near water.

6.Clean only with dry cloth.

7.Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.

8.Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9.Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10.Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11.Only use attachments/accessories specified by the manufacturer.

12.Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.

13.Unplug this apparatus during lightning storms or when unused for long periods of time.

14.Refer all servicing to qualified service personnel. Servicing is required when the

apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has

been dropped. S3125A

S3125A

2 RM-05A

REMOTE AMP WITH ZONE SELECTOR

Features

— SPEAKER LINE CONTROL

Speaker zone of PAM-240A/360A, PCT-610/620 can be controlled by RM-05A.

— CHIME AND TALK FUNCTION

There are 4 levels of chime in PAM-240A/360A, PCT-610/620 which can be triggered by Chime/Talk Switch, and after chime is finished, announcement from mic will be made while pushing switch button.

— OUTPUT LEVEL METER

10 segments LED display on the front panel indicates signal output level of RM-05A at real time.

— MIC BROADCASTING

Highly sensitive condenser type Mic is used for clear broadcasting.

— EXCLUSIVE USE FOR PAM-240A/360A, PCT-610/620

RM-05A is the dedicated remote control amplifier for PAM series, so it only can be used with PAM240A/360A, PCT-610/620.

— MUTE FUNCTION FOR CHIME OUT

Chime melody can be muted by simple operation.

Operatingi Procedure

1.Ensure the Power Switch is selected to the on position.

2.Select which channel or combination of channels you wish to address by selecting the required CH1-CH5 buttons.

3.To address all the channels select the all button.

4.The CH1-CH5 and All buttons are latching type, when selected a LED lights to show the selection you have made.

5.When you are ready to make your address, press the Talk Switch and speak into the microphone.

6.Pressing the Talk Switch will also activate the Pre Announcement Chime facility (for set up details see instructions later in this manual)

7.The microphone output level can be adjusted using the level control located next to the gooseneck microphone connector.

8.After completion of the address the selected CH1-CH5 or All buttons must be deselected clearing the microphone ready for the next selection.

RM-05A 3

Loading…

Микрофонная консоль RM-05A предназначена для совместной работы с усилителями серии PAM и PCT. Для увеличения амплитуды выходного сигнала в консоли предусмотрен предварительный усилитель. С помощью кнопочного селектора на 5 зон возможна трансляция оповещения в любую выбранную зону или несколько зон одновременно. 

На передней панели микрофонной консоли RM-05A расположены регулятор чувствительности микрофона, кнопка включения микрофона, кнопки управления селектором зон, индикатор уровня входного сигнала. 

На задней панели микрофонной консоли RM-05A расположен разъем D-SUB для подключения к усилителю.

Основные характеристики RM-05A

Внутреннее сопротивление 600 Ом
Количество зон 5
Диапазон частот 120-16000 Гц
Напряжение питания 24 В
Максимальная потребляемая мощность 5 Вт
Потребляемая мощность в дежурном режиме 3,5 Вт
Габариты основания (Ш×В×Г) 197×62×207 мм
Габаритные размеры гибкого держателя  Ø19,4×420 мм
Масса (нетто) 1,08 кг

ИНСТРУКЦИИ, ФАЙЛЫ ДЛЯ INTER-M RM-05A

Руководство по эксплуатации

По запросу

Информация:

Цена указана с учетом НДС 20%.

Оптовые цены предоставляются по запросу.

Отгрузка со склада в Санкт-Петербурге.

Подробнее о доставке и оплате

Основные характеристики

Производитель Inter-M
Система оповещения Inter-M PAM-серия, SC-05EM
Селектор зон 5 зон
Встроенные источники сигнал «Гонг»
Диапазон частот 100 Гц-16 кГц
Линейный вход нет
Линейный выход 1В/600 Ом (симметричный)
Питание 24В DC/5 Вт

Все характеристики

Установка и обслуживание охранных систем в Санкт-Петербурге +7 (812) 448-08-18

Заказать монтаж

ОписаниеХарактеристикиДокументацияЗадать вопросДоставка

Назначение
Микрофонная консоль RM-05A предназначена для работы с трансляционными усилителями серии PAM, модели
PAM-340A/480A, PAM-510/520 или с блоком автоматического оповещения SC-05EM.
С помощью консоли RM-05A можно осуществлять передачу речевых сообщений и управлять зонами оповещения.

Конструктивные особенности

  • Настольный микрофон в гибком трубчатом держателе;
  • Селектор на 5 зон оповещения со световой индикацией активных зон;
  • Встроенный тональный сигнал привлечения внимания «Гонг»;
  • Пиковый индикатор уровня выходного сигнала;
  • Регулятор усиления (чувствительности) микрофона;
  • Питание консоли осуществляется по управляющему кабелю от усилителя или блока оповещения.

Технические характеристики RM-05A Inter-M

Производитель Inter-M
Система оповещения Inter-M PAM-серия, SC-05EM
Селектор зон 5 зон
Встроенные источники сигнал «Гонг»
Диапазон частот 100 Гц-16 кГц
Линейный вход нет
Линейный выход 1В/600 Ом (симметричный)
Отношение сигнал/шум более 50 дБ
Управление зонами «сухие контакты», нормально-разомкнутые
Питание 24В DC/5 Вт
Размеры 194х60х205 мм
Вес 1.08 кг

Вы можете задать свой вопрос по данному товару.

Задать вопрос:

Чтобы добавить свой вопрос, пожалуйста, заполните форму ниже.

Доставка товаров

Доставка заказов осуществляется со склада в Санкт-Петербурге через транспортные компании и службы курьерской доставки.

Доставка заказа может осуществляться:

  • до терминала транспортной компании в ближайшем от Вас городе;
  • на точный адрес, доставка «до двери».

Наши преимущества

Проекты под ключ

Разрабатываем проекты под индивидуальные задачи и бюджет

Монтаж и обслуживание

Осуществляем техническое обслуживание и ремонт оборудования

Качество и надежность

На рынке с 2002 года. Наши сотрудники — это инженеры с большим опытом

Гарантии

Работаем по договору. Гарантия на все работы до 3-х лет.

Выгодные условия

Скидки на комплексные поставки оборудования и работы

С этим товаром покупают

Товары категории

Inter-M RM-05A

Консоль микрофонная RM-05A

Код: 5774

В избранное

В сравнение

Функционал: Консоль микрофонная

Единица измерения: шт

Вес: 2,100 кг

Объём: 0,01443 м3

Основной склад: Под заказ

Уточняйте у менеджера Розничная цена

Оставить отзыв

Микрофонная панель Inter-M на 5 зон для усилителей серии PAM и PCT, 120-16000 Гц

ОСОБЕННОСТИ:

— Усиление микрофонного сигнала
Микрофонная панель имеет встроенный предварительный усилитель, увеличивающий амплитуду выходного сигнала.
— Удаление до 500 метров от усилителя
Качество работы микрофонной панели не снижается при удалении до 500 метров от усилителя системы оповещения.
— Работа с настольными системами серий PAM и PCT
Микрофонная панель предназначена для совместной работы с настольными микшер-усилителями: PAM-340A, PAM-480A, PAM-510, PAM-520, PCT-610, PCT-620.
— Подавление окружающего шума
Микрофон панели RM-05A имеет кардиоидную характеристику направленности, обладая максимальной чувствительностью к звуковым сигналам с фронтального направления и очень низкой с тылового направления, что значительно снижает влияние постороннего шума.
— Эффективное подавление помех
Выходной каскад встроенного предварительного усилителя построен по балансной схеме. Благодаря такому схемотехническому решению обеспечивается эффективное подавление помех, наводимых на соединительном кабеле между микрофонной панелью и усилителем системы оповещения.
— Удобная пространственная фиксация микрофона
Гибкая конструкция консольного держателя позволяет быстро и легко фиксировать микрофон в необходимом пространственном положении.
— Пять зон трансляции
Кнопочный селектор позволяет выбрать для оповещения пять независимых зон. Выбор зон для одновременного вещания возможен в любой комбинации.

ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ:

Диапазон частот: 120-16000 Гц
Количество зон: 5
Внутреннее сопротивление: 600 Ом
Назначение: микрофонные панели
Потребляемая мощность в дежурном режиме: 3,5 Вт
Максимальная потребляемая мощность: 5 Вт
Напряжение питания: 24 В
Масса (нетто): 1,08 кг
Масса оборудования с упаковкой: 1,64 кг
Габаритные размеры упаковки (Ш×В×Г): 380×157×261 мм
Габаритные размеры гибкого держателя (D?В): Ø19,4×420 мм
Габаритные размеры основания (Ш?В?Г): 197×62×207 мм

Функционал

Консоль микрофонная

Вы можете произвести примерный расчёт доставки на данный товар для розничного магазина (количество принимается равным 1шт.), для более точного расчёта добавьте товар в корзину, расчёт стоимости будет произведён при переходе на страницу корзины. Для клиентов B2B-портала доставка расчитывается менеджером.

  • Самовывоз со склада в Москве на Ярославском шоссе
  • Курьерская доставка по Москве (только в пределах МКАД)
  • Курьерская доставка по Москве (за пределы МКАД)
  • Самовывоз из пункта Boxberry (Москва)
  • Доставка по России Boxberry

Стоимость доставки: 0 руб.

Понравилась статья? Поделить с друзьями:
  • Инструкция scan tool pro obd2 на русском
  • Инструкция intellicharger new i2 на русском
  • Инструкция rdu 1a выносной дисплей по эксплуатации
  • Инструкция scala rider freecom 4
  • Инструкция insert into содержит неизвестное имя поля