INVT Programming Software & Manuals
NAME | VERSION/ SIZE |
DOWNLOAD |
---|---|---|
INVT Studio | V1.0/42MB | DOWNLOAD |
INVT INVERTER (VFD) Manual
NAME | SIZE | DOWNLOAD |
---|---|---|
INVT Inverter CHF100A Series User Manual |
4.5MB | DOWNLOAD |
INVT Inverter CHE100 Series User Manual |
1.8MB | DOWNLOAD |
INVT Inverter GD100-PV Series User Manual |
7.3MB | DOWNLOAD |
INVT Inverter GD100 Series User Manual |
9.2MB | DOWNLOAD |
INVT Inverter GD20-A Series User Manual |
6.4MB | DOWNLOAD |
INVT Inverter GD200 Series User Manual |
47MB | DOWNLOAD |
INVT Inverter GD200-A Series User Manual |
6.8MB | DOWNLOAD |
INVT Inverter GD300 Series User Manual |
17MB | DOWNLOAD |
INVT Inverter GD300 Lift Series User Manual |
9MB | DOWNLOAD |
INVT Inverter GD20 Series User Manual |
4MB | DOWNLOAD |
INVT Inverter GD20 UL Series User Manual |
5.8MB | DOWNLOAD |
INVT Inverter GD20-EU Series User Manual |
6.8MB | DOWNLOAD |
INVT Inverter GD350 Series User Manual |
20MB | DOWNLOAD |
INVT Inverter GD350-UL Series User Manual |
31MB | DOWNLOAD |
INVT Inverter GD350 IP54 Series User Manual | 21MB | DOWNLOAD |
INVT Inverter GD350 IP55 Series User Manual |
13MB | DOWNLOAD |
INVT Inverter GD350 A Series User Manual |
30MB | DOWNLOAD |
INVT Inverter GD18 Series User Manual |
3.7MB | DOWNLOAD |
INVT Inverter GD310-UL Series User Manual |
9.2MB | DOWNLOAD |
INVT Inverter GD10 Series User Manual |
5.7MB | DOWNLOAD |
INVT Inverter GD800 Series Software User Manual | 75MB | DOWNLOAD |
INVT Inverter GD800 Series Hardware User Manual | 30MB | DOWNLOAD |
INVT AC Servo User Manual
NAME | VERSION/ SIZE |
DOWNLOAD |
---|---|---|
INVT AC Servo DB100 Series User Manual |
V3.0/18MB | DOWNLOAD |
INVT AC Servo DA200 Series User Manual |
V1.0/5.8MB | DOWNLOAD |
INVT AC Servo SV-DL310 Series User Manual |
V1.0/7.0MB | DOWNLOAD |
INVT AC Servo SV-DA300 Series User Manual |
V1.0/27MB | DOWNLOAD |
INVT AC Servo DA180 Series User Manual |
V1.0/10MB | DOWNLOAD |
-
Perfect power systems EXT Series
Perfect Power System Phone: (800)-786-6915 FAX no: (800)-246-2346 Technical Assistance: [email protected] Document No.: 725-MAN, Rev.B All trademarks and registered trademarks are the property of their respective owners. Due to continuous product improvement, this document is subject to change withou …
EXT Series Inverter, 89
-
Motovario AM16 Series
TABLE OF CONTENTS CHAPTER 1 SAFETY PRECAUTIONS ……………………………………………………………………………………………… 1 1.1 BEFORE SUPPLYING POWER TO THE INVERTER ……………………………………………………………………………… 1 1.2 WIRING …………… …
AM16 Series Inverter, 115
-
Toshiba TOSVERT VF-AS3
E6582116Instruction Manual for Load Reduction NOTICE1. Read this manual carefully before installing or operating the inverter.2. All information contained in this manual will be changed without notice. …
TOSVERT VF-AS3 Inverter Drive, 19
-
ZCS AZZURRO Series
Identification: MD-AL-GI-00 Rev. 4.0 of 02/11/2020 — Application: GID Pile Reg. IT12110P00002965 — Share Capital € 100,000.00 fully paid up AR Company Reg. no. 03225010481 — REA AR no. 94189 ISO 9001 Certified Company — Certificate no. 9151 — CNS0 — IT-17778 Zucchetti Centro Sistemi S.p.A. — Green Innovation Divis …
AZZURRO Series Inverter, 45
-
Ningbo Ginlong Technologies Solis-20K
PV Grid Tie InverterInstallation and Operation ManualVer 1.3Solis Three Phase Inverter 2014, Ningbo Ginlong Technologies Co., LtdCNingbo Ginlong Technologies Co., Ltd.No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.China.Tel: +86 (0)574 6578 1806Fax: +86 (0)574 6578 1606If you enco …
Solis-20K Inverter, 26
-
PrimeVOLT PV-5000T-U
Ver. 2.1 (EN) FEB. 2016 Printed on Recycled Paper THREE PHASE ON-GRID PV INVERTER PV-5000T-U & PV-8000T-U & PV-10000T-U & PV-15000T-U & PV-20000T-U Installation & Operation Manual …
PV-5000T-U Inverter, 72
-
Mastervolt WHISPER 6 ULTRA
INSTALLATION MANUAL FOR MOBILE APPLICATIONS WHISPER 6 / 8 / 12 / 16 ULTRA — 1500 RPM — Mobile diesel generating set 230V / 50Hz Digital Diesel Control MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com V5. May 2009 Art.nr. 50200241 …
WHISPER 6 ULTRA Inverter, 48
-
SOLIS Single Phase Inverter
2014, Ningbo Ginlong Technologies Co., Ltd.CNingbo Ginlong Technologies Co., Ltd.No. 57 Jintong Road, Binhai Industrial Park, Xiangshan, Ningbo, Zhejiang, 315712, P.R.ChinaTel: +86 (0)574 6578 1806 Fax: +86 (0)574 6578 1606Email: [email protected]: www.ginlong.comPlease record the serial number of your inverter and q …
Single Phase Inverter Inverter, 18
Download or browse on-line these Operation Manual for INVT CHF100A-1R5G-S2 Inverter.
Summary of Contents:
[Page 1] INVT CHF100A-1R5G-S2 … |
[Page 2] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .1. TABLE OF CONTENTS SAFETY PRECAUTIONS…………………………………………………………………………….3 1. INTRODUCTION…………………….. |
[Page 3] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .2. 6.12 PB Group— Protection Function……………………………………………………..88 6.13 PC Group—Serial Communication……………………………. |
[Page 4] INVT CHF100A-1R5G-S2 … |
[Page 5] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .4. 1. INTRODUCTION 1.1 Technology Features ● Input & Output u Input Voltage Range: 380/220V±15% u Input Frequency Range: 47~63Hz u Output Voltage Range: 0~r… |
[Page 6] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .5. u Automatically keep the output voltage stable when input voltage fluctuating u Up to 25 fault protections: u Protect from over current, over voltage, under voltage… |
[Page 7] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .6. Model No. Rated output Power (kW) Rated input current (A) Rated output current (A) Size CHF100A-037G-2 37.0 132.0 130 F CHF100A-045G-2 45… |
[Page 8] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .7. 1.4 Parts Description Figure 1.2 Parts of inverter (15kw and below). |
[Page 9] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .8. Figure 1.3 Parts of inverter (18.5kw and above). |
[Page 10] INVT CHF100A-1R5G-S2 … |
[Page 11] INVT CHF100A-1R5G-S2 … |
[Page 12] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .11. 3.1 Environmental Requirement 3.1.1 Temperature Environment temperature range: -10°C ~ +40°C. Inverter will be derated at 4%/1°C if ambient temperature exceeds … |
[Page 13] INVT CHF100A-1R5G-S2 … |
[Page 14] INVT CHF100A-1R5G-S2 … |
[Page 15] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .14. 4.2 Terminal Configuration 4.2.1 Main Circuit Terminals (380VAC) R S T U V W (+) PB POWER MOTOR Figure 4.2 Main circuit termina… |
[Page 16] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .15. Figure 4.9 Main circuit terminals (7.5kW). Figure 4.10 Main circuit terminals (11~18.5kW). Figure 4.11 Main circuit terminals (22kW and bigger). the main cir… |
[Page 17] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .16. 4.3 Wiring Diagram 4.3.1 Typical Wiring Diagram Multifunctional On-Off Input 1 Multifunctional On-Off Input 2 Multifunctional On-Off Input 3 +24V 0-10V/0-20mA Analo… |
[Page 18] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .17. disconnect +24V with PW and connect PW with external power supply. u 485+ and 485- are optional for 485 communications. 4.3.2 Outpu and input signal connection Se… |
[Page 19] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .18. S1 S2 Mode of common collector(+24V is public point)exterior power PW COM +24V COM +24V COM PW +24V COM PW +24V S1 S2 Mode of common collector(+24V is… |
[Page 20] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .19. Figure4.17 Wiring at input side. 4.4.2 Wiring at inverter side of main circuit 4.4.2.1 DC reactor Inverters from 18.5kW to 90kW have built-in DC reactor which ca… |
[Page 21] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .20. EMC filter should be installed to minimize the leakage current caused by the cable and minimize the radio noise caused by the cables between the inverter and cable. … |
[Page 22] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .21. When two motors are running at the same time (i.e. winding application), one is in driving status and the other is in regenerative status. In this case the DC buses … |
[Page 23] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .22. 4.5.2 Control circuit terminals Terminal Description S1~S7 ON-OFF signal input, optical coupling with PW and COM. Input voltage range: 9~30V Input impedance: 3…. |
[Page 24] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .23. 4.5.3 Jumper on control board Jumper Description J2, J4 It is prohibited to be connected together, otherwise it will cause inverter malfunction. J16 Switch bet… |
[Page 25] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .24. Three necessary conditions or essentials of electromagnetic interference are: interference source, transmission channel and sensitive receiver. For customers, the s… |
[Page 26] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .25. ground, and the other side should connect to the motor cover. Installing an EMC filter can reduce the electromagnetic noise greatly. 4.6.3.2 Site wiring Power supp… |
[Page 27] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .26. Its value depends on distributed capacitances and carrier frequency of inverter. The over-ground leakage current, which is the current passing through the common gro… |
[Page 28] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .27. 5. OPERATION 5.1 Keypad Description 5.1.1 Keypad schematic diagram Figure 5.1 Keypad schematic diagram. 5.1.2 Function key description Key Name Function De… |
[Page 29] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .28. Key Name Function Description STOP/RESET Key In running status, restricted by P7.04, can be used to stop the inverter. When fault alarm, can be used to res… |
[Page 30] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .29. Have 5 digit LED , which can display all kinds of monitoring data and alarm codes such as reference frequency, output frequency and so on. 5.2 Operation Process … |
[Page 31] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .30. l This function code is not modifiable in running status, but modifiable in stop status. 5.2.2 Fault reset If the inverter has fault, it will prompt the related fa… |
[Page 32] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .31. 5.2.5 Shortcut menu setting Shortcut menu, in which parameters in common use can be programmed, provides a quick way to view and modify function parameters. In the … |
[Page 33] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .32. 5.3.4 Fault In fault status, inverter will display parameters of STOP status besides parameters of fault status. Press the 》/SHIFT to scroll through the paramete… |
[Page 34] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .33. 6. DETAILED FUNCTION DESCRIPTION 6.1 P0 Group—Basic Function Function Code Name Description Setting Range Factory Setting P0.00 Control model 0: V… |
[Page 35] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .34. 1: Terminal (LED flickering) The operation, including forward run, reverse run, forward jog, reverse jog etc. can be controlled by multifunctional input terminals. … |
[Page 36] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .35. Notice: The frequency reference should not exceed maximum frequency, and it is the basis of ramping time of ACC/DEC. Function Code Name Description Setting Ran… |
[Page 37] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .36. 0: Keypad: Please refer to description of P0.06 1: AI1 2: AI2 The reference frequency is set by analog input. AI1 is -10V~10V voltage input terminal, while AI2 i… |
[Page 38] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .37. For details, please refer to P0.07. Function Code Name Description Setting Range Factory Setting P0.09 Scale of frequency B command 0: Maximum fre… |
[Page 39] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .38. Figure 6.1 Acceleration and deceleration time. When the reference frequency is equal to the maximum frequency, the actual acceleration and deceleration time will … |
[Page 40] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .39. Figure 6.2 Effect of carrier frequency. The following table is the relationship between power rating and carrier frequency. Carrier f Model Highest Carrier f … |
[Page 41] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .40. Function Code Name Description Setting Range Factory Setting P0.16 Motor parameters autotuning 0: No action 1: Rotation autotuning 2: Static autot… |
[Page 42] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .41. Function Code Name Description Setting Range Factory Setting P0.17 Restore parameters 0: No action 1: Restore factory setting 2: Clear fault record… |
[Page 43] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .42. l The starting frequency could be less than the lower frequency limit (P0.05). l P1.01 and P1.02 take no effect during FWD/REV switching. Figure 6.3 Starting di… |
[Page 44] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .43. time, which can be determined by the multifunctional ON-OFF input terminals (P5 Group). Function Code Name Description Setting Range Factory Setting P1.0… |
[Page 45] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .44. Figure 6.4 DC braking diagram. Function Code Name Description Setting Range Factory Setting P1.11 Dead time of FWD/REV 0.0~3600.0s 0.0~3600.0 … |
[Page 46] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .45. 0: Running at the lower frequency limit (P0.05): The inverter runs at P0.05 when the running frequency is less than P0.05. 1: Stop: This parameter is used to preven… |
[Page 47] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .46. on Notice: l This function only takes effect if run command source is terminal control. l If P1.15 is set to be 0, when power on, inverter will not start even i… |
[Page 48] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .47. according to motor nameplate, and then perform autotuning. l The power rating of inverter should match the motor. If the bias is too big, the control performances … |
[Page 49] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .48. Function Code Name Description Setting Range Factory Setting P3.04 ASR integral time K i 2 0.01~10.00s 0.01~10.00 1.00s P3.05 ASR switching po… |
[Page 50] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .49. u Increase the proportional gain (Kp) as far as possible without creating oscillation. u Reduce the integral time (Ki) as far as possible without creating oscillatio… |
[Page 51] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .50. Under speed control model, output torque matches load torque automatically, but limited by P3.07. Under torque control model, output torque is limited by upper and … |
[Page 52] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .51. 2~4: Torque_stepdown curve. It is applicable for variable torque load, such as blower, pump and so on. Please refer to following figure. Notice:Vb= Motor rated vo… |
[Page 53] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .52. Figure 6.9 Torque boost by hand. Function Code Name Description Setting Range Factory Setting P4.03 V/F frequency 1 0.00Hz~P4.05 0.00~P4.05 0.00… |
[Page 54] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .53. Function Code Name Description Setting Range Factory Setting P4.09 Slip compensation limit 0.00~200.0% 0.00~200.00 0.0% The slip compensation fun… |
[Page 55] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .54. restraining oscillation.When the running frequency is lower than P4.13, P4.11 is valid, when the running frequency higher than P4.13, P4.12 is valid. 6.6 P5 Group—… |
[Page 56] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .55. Setting value Function Description coasts to stop by its mechanical inertia. 7 Reset fault Resets faults that have occurred. It has the same function as S… |
[Page 57] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .56. Setting value Function Description reference 4 20 Multi-step speed pause Keep current step unchanged no matter what the input status of four multi-step sp… |
[Page 58] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .57. Setting value Function Description control mode speed control mode. 30 Forbid the function of ACC/DEC ACC/DEC is invalid and maintains output frequen… |
[Page 59] INVT CHF100A-1R5G-S2 … |
[Page 60] INVT CHF100A-1R5G-S2 … |
[Page 61] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .60. Function Code Name Description Setting Range Factory Setting P5.13 AI1 lower limit corresponding setting -100.0%~100.0% -100.0~100.0 0.0% P5.14 … |
[Page 62] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .61. Function Code Name Description Setting Range Factory Setting P5.19 AI2 upper limit 0.00V~10.00V 0.00~10.00 10.00V P5.20 AI2 upper limit corres… |
[Page 63] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .62. Notice: The output of HDO terminal is OC (open collector) output. Function Code Name Description Setting Range Factory Setting P6.01 HDO ON- OFF outpu… |
[Page 64] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .63. Setting Value Function Description 11 Simple PLC step completed After simple PLC completes one step, inverter will output ON signal for 500ms. 12 PLC cycle … |
[Page 65] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .64. Setting Value Function Range 8 AI1 voltage -10~10V 9 AI2 voltage/current 0~10V/0~20mA 10 HDI frequency 0.1~50.0kHz Function Code Name Description S… |
[Page 66] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .65. Function Code Name Description Setting Range Factory Setting P6.11 AO2 lower limit 0.0~100.0% 0.0~100.0 0.0% P6.12 AO2 lower limit correspo… |
[Page 67] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .66. 6.8 P7 Group—Display Interface Function Code Name Description Setting Range Factory Setting P7.00 User password 0~65535 0~65535 0 The password pr… |
[Page 68] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .67. Function Code Name Description Setting Range Factory Setting communication control (P0.02=0 or 2) 3: Always valid Notice: l The value of P7.04 only … |
[Page 69] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .68. If Bit is 0, the parameter will not be displayed; If Bit is 1, the parameter will be displayed. Press 》/SHIFT to scroll through these parameters in right order . … |
[Page 70] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .69. Function Code Name Description Setting Range Factory Setting P7.08 Stop status display selection 0~0xFFFF 0~0xFFFF 0x00FF P7.08 determines the… |
[Page 71] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .70. Function Code Name Description Setting Range Factory Setting P7.11 Rectify module temperature 0~100.0℃ P7.12 IGBT module temperature 0~… |
[Page 72] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .71. Function Code Name Description Setting Range Factory Setting P7.20 Output frequency at current fault Output frequency at current fault. P7.21 … |
[Page 73] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .72. 6.9 P8 Group—Enhanced Function Function Code Name Description Setting Range Factory Setting P8.00 Acceleration time 1 0.1~3600.0s 0.1~3600.0 De… |
[Page 74] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .73. Notice: l If P8.11 is 0, the skip function is invalid. l If both P8.09 and P8.10 are 0, the skip function is invalid no matter what P8.11 is. l Operation is … |
[Page 75] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .74. Figure 6.18 Traverse operation diagram. Center frequency (CF) is reference frequency. Traverse amplitude (AW) =center frequency (CF) * P8.12% Jitter frequency =… |
[Page 76] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .75. The count pulse input channel can be S1~S4 (≤200Hz) and HDI. If function of output terminal is set as preset count reached, when the count value reaches preset c… |
[Page 77] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .76. frequency of FDT level (FDT level — FDT lag), as shown in following figure. Figure 6.20 FDT level and lag diagram. Function Code Name Description Setting Ran… |
[Page 78] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .77. When the motor outputs rated torque, actual frequency drop is equal to P8.24. User can adjust this parameter from small to big gradually during commissioning. The re… |
[Page 79] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .78. Function Code Name Description Setting Range Factory Setting P8.27 Overmodulation 0: Invalid 1: Valid 0~1 0 The function is applicable in the inst… |
[Page 80] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .79. Function Code Name Description Setting Range Factory Setting P9.00 PID preset source selection 0: Keypad 1: AI1 2: AI2 3: HDI 4: Multi-step 5: Com… |
[Page 81] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .80. Function Code Name Description Setting Range Factory Setting P9.06 Differential time (Td) 0.00~10.00s 0.00~10.00 0.00s Optimize the responsiveness… |
[Page 82] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .81. Figure 6.25 Reducing long-cycle oscillation diagram. l Reducing short-cycle oscillation If the oscillation cycle is short and oscillation occurs with a cycle app… |
[Page 83] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .82. Figure 6.27 Relationship between bias limit and output frequency. Function Code Name Description Setting Range Factory Setting P9.09 Feedback lost … |
[Page 84] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .83. 0: Stop after one cycle: Inverter stops automatically as soon as it completes one cycle, and It needs run command to start again. 1: Hold last frequency after one c… |
[Page 85] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .84. Function Code Name Description Setting Range Factory Setting PA.07 2 nd Step running time 0.0~6553.5 s(m) 0.0~6553.5 0.0s PA.08 Multi-step s… |
[Page 86] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .85. Function Code Name Description Setting Range Factory Setting PA.23 10 th Step running time 0.0~6553.5 s(m) 0.0~6553.5 0.0s PA.24 Multi-step … |
[Page 87] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .86. Figure 6.29 Multi-steps speed operation diagram. Terminal Step Multi-step speed reference1 Multi-step speed reference2 Multi-step speed reference3 Multi… |
[Page 88] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .87. Function Code Name Description Setting Range Factory Setting PA.35 ACC/DEC time selection for step 8~15 0~0XFFFF 0~0XFFFF 0 These parameters a… |
[Page 89] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .88. High byte BIT 8 BIT 9 BIT 10 BIT 11 BIT 12 BIT 13 BIT 14 BIT 15 PA.34 0 1 1 0 1 1 0 0 PA.35 0 0 0 0 0 1 0 1 So t… |
[Page 90] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .89. Function Code Name Description Setting Range Factory Setting PB.01 Output phase-failure protection 0: Disable 1: Enable 0~1 1 Notice: Please be cau… |
[Page 91] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .90. rated power of motor. l Motor overload protection time: 60s with 200% of rated current. For details, please refer to above figure. Function Code Name Descripti… |
[Page 92] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .91. Figure 6.32 Over-voltage stall function. Function Code Name Description Setting Range Factory Setting PB.08 Auto current limiting threshold 50~200% … |
[Page 93] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .92. change; therefore, it is recommended not to enable the function when inverter needs to output stable frequency l During auto current limiting process, if PB.08 is … |
[Page 94] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .93. This value is depending on model. Function Code Name Description Setting Range Factory Setting PB.13 D etection time cof overtorque 0.0~60.0s 0~60 … |
[Page 95] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .94. Function Code Name Description Setting Range Factory Setting PC.02 Data format 0: RTU, 1 start bit, 8 data bits, no parity check, 1 stop bit. 1: RTU… |
[Page 96] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .95. Function Code Name Description Setting Range Factory Setting according to P1.06 (if P0.01=2) 3: No alarm but stop according to P1.06 0: When communicat… |
[Page 97] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .96. 6.14 PD Group—Supplementary Function Function Code Name Description Setting Range Factory Setting PD.00-PD.09 Reserved 6.15 PE Group—… |
[Page 98] INVT CHF100A-1R5G-S2 … |
[Page 99] INVT CHF100A-1R5G-S2 CHF100A series high performance universal inverter .98. Fault Code Fault Type Reason Solution UV DC bus Under-voltage 1.Open phase occurred with power supply. 2.Momentary power loss occurred 3.Wiring t… |
[Page 100] INVT CHF100A-1R5G-S2 … |