Кондиционер аксон инструкция к пульту

Acson AWM 07G' AWM 07GR User Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

Models:

AWM 07G/GR

AWM 09G/GR

AWM 10G/GR

AWM 15G/GR

AWM 20G/GR

AWM 25G/GR

AWM 301/301R

A5WM 07G/GR

A5WM 09G/GR

A5WM 10G/GR

A5WM 15G/GR

A5WM 20G/GR

A5WM 25G/GR

A5WM 311/301R

Wall Mounted Split Systems

AWM — G — 2007

Downloaded from AC-Manual.com Manuals

loading

Related Manuals for Acson AWM 07G’ AWM 07GR

Summary of Contents for Acson AWM 07G’ AWM 07GR

  • Page 1
    Models: AWM 07G/GR AWM 09G/GR AWM 10G/GR AWM 15G/GR AWM 20G/GR AWM 25G/GR AWM 301/301R A5WM 07G/GR A5WM 09G/GR A5WM 10G/GR A5WM 15G/GR A5WM 20G/GR A5WM 25G/GR A5WM 311/301R Wall Mounted Split Systems AWM — G — 2007 Downloaded from AC-Manual.com Manuals…
  • Page 2: Table Of Contents

    TABLE OF CONTENTS 1. NOMENECLATURE ………………..1 — PRODUCT LINE-UP ……………….. 3 2. FEATURES …………………… 7 3. APPLICATION INFORMATION — OPERATING RANGE ………………9 — REFRIGERANT CIRCUIT DIAGRAMS ………….. 10 — CONTROLLERS ………………..17 — INSTALLATION ………………..25 4. SOUND DATA ………………….39 5.

  • Page 3: Nomeneclature

    Model Type R : Heatpump Omitted if Cooling Only Series G : G series Capacity 10 : 9,500 Btu/h Model Name WM : Wall Mounted Refrigerant 5 : R410A Omitted if R22 Brand A : ACSON Downloaded from AC-Manual.com Manuals…

  • Page 4: Model Name

    R : Heatpump Omitted if Cooling Only Series C : C series Capacity 10 : 9,500 Btu/h Model Name LC : Single Split Condensing Unit Refrigerant 5 : R410A Omitted if R22 Model Brand A : ACSON Downloaded from AC-Manual.com Manuals…

  • Page 5: Product Line-Up

    Product Line Up INDOOR UNIT AWM-G SERIES PRODUCT LINE UP CLASSIFICATIONS Handset Air Purification ACIAD ACIAC ACIAC ACIAC ACIAC ACIAC AFDB 07GR ACIAC 09GR ACIAC 10GR ACIAC 15GR ACIAC 20GR ACIAC 25GR ACIAC 30FR AFCA Downloaded from AC-Manual.com Manuals…

  • Page 6
    INDOOR UNIT A5WM-G SERIES PRODUCT LINE UP CLASSIFICATIONS Handset Air Purification A5WM ACIAC ACIAC ACIAC ACIAC ACIAC ACIAC AFCA 07GR ACIAC 09GR ACIAC 10GR ACIAC 15GR ACIAC 20GR ACIAC 25GR ACIAC 301R AFCA Downloaded from AC-Manual.com Manuals…
  • Page 7
    OUTDOOR UNIT ALC PRODUCT LINE UP CLASSIFICATIONS Safety Refrigerant Ctrl + Fin Marking Market Devices ACPOE ACPIE ACPOD ACPID ACPOB ACPIB ACPOD ACPID ATPOD ACPOD ACPID ACPBD ACPOD ACPID ACPBD ATPOD ACPBD ACPOD ACPID ACPOD 18CR ACPID ACPBD ACPOD 20CR ACPID ACPBD ACPBD…
  • Page 8
    OUTDOOR UNIT A5LC PRODUCT LINE UP CLASSIFICATIONS Refrigerant Safety Devices Marking Others Compressor Ctrl + Fin A5LC ACPOE ACPOB ACPOC ACPOC ACPOC ACPOA 07CR ACPOE 10CR ACPOB 15CR ACPOC 20CR ACPOC 25CR ACPOC 28CR ACPOA Downloaded from AC-Manual.com Manuals…
  • Page 9: Features

    2. FEATURES • EASY INSTALLATION The wall mounted fan coil unit is easily installed because of its compact size, slimness and light weight. Slim and short outdoor unit can be easily installed even in a narrow balcony and passageway and yet have a stable profile.

  • Page 10: Self Diagnosis

    • HIGH EFFICIENCY HEAT EXCHANGER — The compact design of the 3-fold structure heat exchanger provides a large surface are for better and efficient heat exchange. The unique Hydrophilic slit fin has greatly improved the air flow and the contact surfaces with the air thus to boost the cooling capacity.

  • Page 11: Application Information

    3. APPLICATION INFORMATION Operating Range Ensure the operating temperature is in allowable range. Cooling only Cooling HIGH AMBIENT UNIT Caution : The use of your air conditioner outside the range of working temperature and humidity can result in serious failure. LOW AMBIENT Indoor temp.

  • Page 12: Refrigerant Circuit Diagrams

    Refrigerant Circuit Diagram Cooling Only Models MODEL : AWM 07G — ALC 07C A5WM 07G — A5LC 07C AWM 09G — ALC 09C A5WM 09G — A5LC 10C AWM 10G — ALC 10C A5WM 10G — A5LC 10C AWM 15G — ALC 15C A5WM 15G — A5LC 15C Downloaded from AC-Manual.com Manuals…

  • Page 13
    Cooling Only Models MODEL : AWM 20G — ALC 18C A5WM 20G — A5LC 20C AWM 20G — ALC 20C A5WM 25G — A5LC 25C MODEL : AWM 25G — ALC 25C A5WM 31F — A5LC 28C Downloaded from AC-Manual.com Manuals…
  • Page 14
    Cooling Only Models MODEL : AWM 30F — ALC 28C Downloaded from AC-Manual.com Manuals…
  • Page 15
    Heatpump Models MODEL : AWM 09GR — ALC 09CR A5WM 07GR — A5LC 07CR MODEL : AWM 10GR — ALC 10CR A5WM 09GR — A5LC 10CR A5WM 10GR — A5LC 10CR Downloaded from AC-Manual.com Manuals…
  • Page 16
    Heatpump Models MODEL : AWM 15GR — ALC 15CR A5WM 15GR — A5LC 15CR Downloaded from AC-Manual.com Manuals…
  • Page 17
    Heatpump Models MODEL : AWM 20GR — ALC 20CR A5WM 20GR — A5LC 20CR A5WM 25GR — A5LC 25CR MODEL : AWM 25GR — ALC 25CR Downloaded from AC-Manual.com Manuals…
  • Page 18
    Heatpump Models MODEL : AWM 30FR — ALC 28CR A5WM 30FR — A5LC 28CR Downloaded from AC-Manual.com Manuals…
  • Page 19: Controllers

    Controllers G12 Remote Controller Temperature Setting Personalised Setting • • Press and hold the button for 3s to To set the desired room initiate personalized setting. temperature, press the button to increase or decrease the set • Set the individual setting e.g. temperature.

  • Page 20: Indicator Lights

    Indicator Lights AWM / A5WM — G SERIES IR signal receiver When there is infrared remote control operating signal, the signal receiver on indoor unit will made a (beep) for signal acceptance confirmation. Cooling unit / Heatpump unit LED Indicator Lights for Cooling Unit / Heatpump The table below shows the LED indicator light for air Unit conditioner unit under normal operation and fault…

  • Page 21
    AWM 30F / 30FR , A5WM 31F / 30FR LED Indicator Lights For Cooling Unit LED Indicator Lights : Normal Operation And Fault Conditions For Cooling Unit Operation / Fault Indication Action Power Timer Sleep Timer on Sleep mode on Dry mode on Clean the filter and switch to high fan Frost prevention…
  • Page 22
    LED Indicator Lights For Heatpump Unit Cooling mode Dry mode Heat/Fan mode Sleep mode (red/green) LED Indicator Lights : Normal Operation And Fault Conditions For Cooling Unit Normal Operation / Fault Indication Action Cool Heat Sleep Cooling mode Dry mode Fan mode Heat mode Auto mode in heating operation…
  • Page 23: Controller Specifications

    Controller Specifications (A) 3 HOT SYSTEM (HEATING CYCLE) a) Hot start At the beginning of heating operation (cold start, after defrosting or thermostat resumes operation) the indoor fan operation is controlled in accordance with the temperature of the indoor heat exchanger to send warm air from the start.

  • Page 24
    Hot Keep (Apply to AWM-GR) After thermostat cut out, the indoor fan operation is controlled in accordance with the indoor heat exchanger temperature to utilize the extra heat and preserve indoor comfort. The indoor fan can be switched to ON, OFF by setting the slide switch shown in the diagram. This slide switch is located at the front frame cover.
  • Page 25
    (B) TURBO MODE (APPLY TO AWM-GR) TURBO function is available in COOL, HEAT and DRY modes only. When TURBO function is set, working temperature for cooling cycle is decreased by 2 C, working temperature for heating cycle is increased by 2 The indoor fan will force to HIGH fan.
  • Page 26
    (E) FROST PREVENTION AND FILTER CHECK In order to prevent the freezing of indoor coil, the controller will operate as follow. 1°C (F) AUTO RANDOM RESTART When power resumed, the unit will automatically restart and operate at the previous setting as before power failure occurred.
  • Page 27: Installation

    Installation Installation Diagram Downloaded from AC-Manual.com Manuals…

  • Page 28
    CAUTION: Before installing the unit, ensure that the power supply matches the power requirement of the air conditioner. 1) SELECTION OF LOCATION AND SPACE (A) INDOOR UNIT Install the fan coil (indoor) unit at a location with the following requirements •…
  • Page 29
    (B) OUTDOOR UNIT As condensing temperature rises, evaporating temperature rises and cooling capacity drops. In order to achieve maximum cooling capacity, the location selected for outdoor unit should fulfill the following requirements : • Install the condensing (outdoor) unit in a way such that hot air distributed by the outdoor condensing unit cannot be drawn in again (as in the case of short circuit of hot discharge air).
  • Page 30
    CONDENSED WATER DISPOSAL OF OUTDOOR UNIT (HEATPUMP UNIT ONLY) There are 2 holes on the base of outdoor unit for condensed water to flow out. Insert the drain elbow to • one of the holes. To install the drain elbow, first insert one portion of the hook to the base (portion A), then pull the drain •…
  • Page 31
    2) DRILLING HOLES AND MOUNTING INSTALLATION PLATE CAUTION: i) Please check the unit weight for each model. Always ensure that the wall is sufficiently strong to withstand the weight. If not, it is necessary to reinforce the wall with plate, beams or pillars. ii) The unit cannot be directly fixed onto the wall or the likes.
  • Page 32
    • Fixing method:- WOODEN REINFORCED CONCRETE BUILDING FRAME WALL NUT ANCHOR BOLT ANCHOR 3) INDOOR UNIT PREPARATION • • The refrigerant piping can be routed to the unit in 5 Carefully bend the pipes to the required position to direction, by using the cut outs in the unit casing. align with the hole.
  • Page 33
    6) WIRING ELECTRICAL CONNECTION • Wiring regulation on wire diameters differ from country to country. Please refer to your LOCAL ELECTRICAL CODES for field wiring rules. Be sure that installation comply with such rules and regulations. GENERAL PRECAUTIONS • Ensure that the rated voltage of the unit corresponds to the name plate before carrying out proper wiring according to the wiring diagram.
  • Page 34
    • Remove burr with the burr remover. Hold the flaring end down to prevent burrs from dropping inside pipe. • The exact length of pipe protruding from the face of the flare die is determined by the flaring tool. The table shows the use of an imperial die and riged die.
  • Page 35
    Steps : a) Directly connect the “Female” nut of orifice pipe to the liquid pipe. b) Flare the liquid pipe and connect it to the “Male” joint of the orifice pipe. ii) Outdoor Installation Space Is Limited If the orifice pipe can not be connected directly to the liquid valve due to limitation space, it can be connected between the liquid pipes.
  • Page 36
    c) Connect the “Female” nut of the orifice pipe to the “Male” joint. d) Flare another liquid pipe and connect it to the “Male”joint of the orifice pipe. 9) VACUUMING AND CHARGING • The precharged outdoor unit does not need any vacuuming or charging. However once it is connected, the connecting pipe line and the indoor need to be vacuumed before releasing the R22/R407C/R410A from the outdoor unit.
  • Page 37: Additional Charge

    5) Decision by low side pressure. Turn compressor on for 10 or 15 min. Standard Condition Heavy Load Condition Model Indoor 27°C / Outdoor 35°C Indoor 32°C / Outdoor 43°C kg/cm² psig kg/cm² psig AWM 07G 5.2 ~ 5.7 74.3 ~ 81.0 5.7 ~ 6.2 81.9 ~ 89.1 AWM 09G…

  • Page 38
    Diagram shows typical charging method. Note : R22 — Nil R410A — Nil CAUTION FOR R410A Avoid prolong exposure of an opened compressor, or the internal part of refrigerant piping to moist air. The POE oil in the compressor and piping can absorb moisture from air. 10) FINAL CHECKING •…
  • Page 39
    SPECIAL PRECAUTIONS WHEN DEALING WITH REFRIGERANT R410A UNIT 1) WHAT IS NEW REFRIGERANT R410A? R410A is a new HFC refrigerant which does not damage the ozone layer. The working pressure of this new refrigerant is 1.6 times higher than conventional refrigerant (R22), thus proper installation / servicing is essential.
  • Page 40
    d) When charging R410A, ensure that only liquid is being withdrawn from the cylinder or can. This is to ensure that only the original composition of R410A is being delivered into the system. The liquid composition can be different from the vapor composition. Invert cylinder Dip-pipe without dip-pipe…
  • Page 41: Sound Data

    4. SOUND DATA Sound Pressure Level (Measured In Anechoic Room) WALL MOUNTED FAN COIL UNIT Speed 1/1 Octave Sound Pressure Level (dB, ref 20µPa) Overall Noise Model (dBA) Criteria (RPM) 125 Hz 250 Hz 500 Hz 1k Hz 2k Hz 4k Hz 8k Hz HIGH…

  • Page 42
    AWM 07G, 09 G/GR , A5WM 07 / 09 G/GR NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 Low Fan NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 10 G/GR , A5WM 10 G/GR NC CURVES NC-45 NC-40 High Fan…
  • Page 43
    AWM 15 G/GR , A5WM 15 G/GR NC CURVES NC-45 NC-40 High Fan NC-35 Medium Fan NC-30 NC-25 NC-20 Low Fan 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 20 G/GR , A5WM 20 G/GR NC CURVES High Fan NC-45 Medium Fan NC-40 Low Fan…
  • Page 44
    AWM 25 G/GR , A5WM 25 G/GR NC CURVES High Fan Medium Fan NC-45 Low Fan NC-40 NC-35 NC-30 NC-25 NC-20 1000 2000 4000 8000 Octave-band frequency (Hz) AWM 311/301R , A5WM 311/301R NC CURVES NC-50 NC-45 High Fan NC-40 Medium Fan Low Fan NC-35…
  • Page 45: Engineering And Physical Data

    5. ENGINEERING AND PHYSICAL DATA General Data — Cooling Only (R22) AWM 07G AWM 09G INDOOR UNIT MWM 007G MWM 009G MODEL ALC 07C ALC 09C OUTDOOR UNIT MLC 007C MLC 009C Btu/h 7000 9000 NOMINAL CAPACITY 2050 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT POWER SOURCE V/Ph/Hz…

  • Page 46
    General Data — Cooling Only (R22) INDOOR UNIT AWM 10G AWM 15G MWM 010G MWM 015G MODEL ALC 10C ALC 15C OUTDOOR UNIT MLC 010C MLC 015C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1100 NOMINAL RUNNING CURRENT POWER SOURCE 220-240/1/50 V/Ph/Hz…
  • Page 47
    General Data — Cooling Only (R22) INDOOR UNIT AWM 20G AWM 20G MWM 020G MWM 020G MODEL ALC 18C ALC 20C OUTDOOR UNIT MLC 018C MLC 020C Btu/h 18000 19000 NOMINAL CAPACITY 5280 5570 NOMINAL TOTAL INPUT POWER 1,810 1,807 NOMINAL RUNNING CURRENT POWER SOURCE 220-240/1/50…
  • Page 48
    General Data — Cooling Only (R22) INDOOR UNIT AWM 25G AWM 311 MWM 025G MWM 030F MODEL ALC 25C ALC 28C OUTDOOR UNIT MLC 025C MLC 028C Btu/h 23,500 27000 NOMINAL CAPACITY 6,890 7913 NOMINAL TOTAL INPUT POWER 2,530 2732 NOMINAL RUNNING CURRENT 11.3 13.1…
  • Page 49
    General Data — Heatpump Only (R22) AWM 09GR INDOOR UNIT MWM 009GR MODEL ALC 09CR OUTDOOR UNIT MLC 009CR Btu/h 9000 NOMINAL COOLING CAPACITY 2640 Btu/h 9000 NOMINAL HEATING CAPACITY 2640 NOMINAL TOTAL INPUT POWER (COOLING) NOMINAL TOTAL INPUT POWER (HEATING) NOMINAL RUNNING CURRENT (COOLING) NOMINAL RUNNING CURRENT (HEATING) POWER SOURCE…
  • Page 50
    General Data — Heatpump (R22) INDOOR UNIT AWM 10GR AWM 15GR MWM 010GR MWM 015GR MODEL OUTDOOR UNIT ALC 10CR ALC 15CR MLC 010CR MLC 015CR Btu/h 9500 12000 NOMINAL COOLING CAPACITY 2780 3520 Btu/h 9500 12000 NOMINAL HEATING CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER (COOLING)
  • Page 51
    General Data — Heatpump (R22) INDOOR UNIT AWM 20GR AWM 20GR MWM 020GR MWM 020GR MODEL OUTDOOR UNIT ALC 18CR ALC 20CR MLC 018CR MLC 020CR Btu/h 18000 19000 NOMINAL COOLING CAPACITY 5280 5570 Btu/h 18400 19500 NOMINAL HEATING CAPACITY 5390 5720 NOMINAL TOTAL INPUT POWER (COOLING)
  • Page 52
    General Data — Heatpump (R22) AWM 25GR AWM 301R INDOOR UNIT MWM 025GR MWM 030FR MODEL ALC 25CR ALC 28CR OUTDOOR UNIT MLC 025CR MLC 028CR Btu/h 23,500 27000 NOMINAL COOLING CAPACITY 6,890 7913 Btu/h 24,000 27000 NOMINAL HEATING CAPACITY 7,030 7913 NOMINAL TOTAL INPUT POWER (COOLING)
  • Page 53
    General Data — Cooling Only (R410A) A5WM 07G A5WM 09G INDOOR UNIT M5WM 007G M5WM 009G MODEL A5LC 07C A5LC 09C OUTDOOR UNIT M5LC 007C M5LC 010C Btu/h 7500 9000 NOMINAL CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER NOMINAL RUNNING CURRENT POWER SOURCE 220-240/1/50 V/Ph/Hz…
  • Page 54
    General Data — Cooling Only (R410A) A5WM 10G A5WM 15G INDOOR UNIT M5WM 010G M5WM 015G MODEL A5LC 10C A5LC 15C OUTDOOR UNIT M5LC 010C M5LC 015C Btu/h 9500 12000 NOMINAL CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER 1230 NOMINAL RUNNING CURRENT POWER SOURCE 220-240/1/50 V/Ph/Hz…
  • Page 55
    General Data — Cooling Only (R410A) A5WM 20G A5WM 25G INDOOR UNIT M5WM 020G M5WM 025G MODEL A5LC 20C A5LC 25C OUTDOOR UNIT M5LC 020C M5LC 025C Btu/h 18000 / <18000> 21000 / <22500> NOMINAL CAPACITY — 1Ø / <3Ø> 5280 / <5280>…
  • Page 56
    General Data — Cooling Only (R410A) A5WM 311 INDOOR UNIT M5WM 031F MODEL A5LC 28C OUTDOOR UNIT M5LC 028C Btu/h 26000 / <26000> NOMINAL CAPACITY — 1Ø / <3Ø> 7620 / <7620> NOMINAL TOTAL INPUT POWER — 1Ø / <3Ø> 2560 / <2631>…
  • Page 57
    General Data — Heatpump (R410A) A5WM 07GR A5WM 09GR INDOOR UNIT M5WM 007GR M5WM 009GR MODEL OUTDOOR UNIT A5LC 07CR A5LC 09CR M5LC 007CR M5LC 010CR Btu/h 7500 9000 NOMINAL COOLING CAPACITY 2200 2640 Btu/h 7500 9000 NOMINAL HEATING CAPACITY 2200 2640 NOMINAL TOTAL INPUT POWER (COOLING)
  • Page 58
    General Data — Heatpump (R410A) A5WM 10GR A5WM 15GR INDOOR UNIT M5WM 010GR M5WM 015GR MODEL OUTDOOR UNIT A5LC 10CR A5LC 15CR M5LC 010CR M5LC 015CR Btu/h 9500 12000 NOMINAL COOLING CAPACITY 2780 3520 Btu/h 9500 12000 NOMINAL HEATING CAPACITY 2780 3520 NOMINAL TOTAL INPUT POWER (COOLING)
  • Page 59
    General Data — Heatpump (R410A) A5WM 20GR A5WM 25GR INDOOR UNIT M5WM 020GR M5WM 025GR MODEL A5LC 20CR A5LC 25CR OUTDOOR UNIT M5LC 020CR M5LC 025CR Btu/h 17850 / <18000> 20350 / <22500> NOMINAL COOLING CAPACITY — 1Ø / <3Ø> 5230 / <5280>…
  • Page 60
    General Data — Heatpump (R410A) A5WM 311 INDOOR UNIT M5WM 030FR MODEL A5LC 28CR OUTDOOR UNIT M5LC 028CR Btu/h 26000 / <26000> NOMINAL COOLING CAPACITY — 1Ø / <3Ø> 7620 / <7620> Btu/h 26000 / <26000> NOMINAL HEATING CAPACITY — 1Ø / <3Ø> 7620 / <7620>…
  • Page 61: Components Data

    Components Data — Cooling Only (R22) AWM 07G AWM 09G INDOOR UNIT MWM 007G MWM 009G MODEL ALC 07C ALC 09C OUTDOOR UNIT MLC 007C MLC 009C TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DIRECT DRIVE DIAMETER 97/3.8 mm/in…

  • Page 62
    Components Data — Cooling Only (R22) AWM 10G AWM 15G INDOOR UNIT MWM 010G MWM 015G MODEL ALC 10C ALC 15C OUTDOOR UNIT MLC 010C MLC 015C TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT 97/3.8 DIAMETER mm/in…
  • Page 63
    Components Data — Cooling Only (R22) AWM 20G AWM 20G INDOOR UNIT MWM 020G MWM 020G MODEL ALC 18C ALC 20C OUTDOOR UNIT MLC 018C MLC 020C TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT 108/4.25 DIAMETER mm/in…
  • Page 64
    Components Data — Cooling Only (R22) AWM 25G AWM 311 INDOOR UNIT MWM 025G MWM 030F MODEL ALC 25C ALC 28C OUTDOOR UNIT MLC 025C MLC 028C TYPE CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DIRECT DRIVE…
  • Page 65
    Components Data — Heatpump (R22) AWM 09GR INDOOR UNIT MWM 009GR MODEL ALC 09CR OUTDOOR UNIT MLC 009CR TYPE ANTI FUNGUS SKEW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 97/3.8 LENGTH mm/in 617.5/24.3 TYPE INDUCTION INDOOR FAN QUANTITY MOTOR…
  • Page 66
    Components Data — Heatpump (R22) AWM 10GR AWM 15GR INDOOR UNIT MWM 010GR MWM 015GR MODEL ALC 10CR ALC 15CR OUTDOOR UNIT MLC 010CR MLC 015CR TYPE ANTI FUNGUS SKEW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DRIVE DIRECT DIAMETER 97/3.8 mm/in…
  • Page 67
    Components Data — Heatpump (R22) AWM 20GR AWM 20GR INDOOR UNIT MWM 020GR MWM 020GR MODEL ALC 18CR ALC 20CR OUTDOOR UNIT MLC 018CR MLC 020CR TYPE CROSS FLOW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DRIVE DIRECT DIAMETER 108/4.25 mm/in 810/31.9…
  • Page 68
    Components Data — Heatpump (R22) AWM 25GR AWM 311R INDOOR UNIT MWM 025GR MWM 030FR MODEL ALC 25CR ALC 28CR OUTDOOR UNIT MLC 025CR MLC 028CR TYPE CROSS FLOW FAN ANTI FUNGUS CROSS FLOW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DRIVE DIRECT…
  • Page 69
    Components Data — Cooling Only (R410A) A5WM 07G A5WM 09G INDOOR UNIT M5WM 007G M5WM 009G MODEL A5LC 07C A5LC 10C OUTDOOR UNIT M5LC 007C M5LC 010C TYPE ANTI FUNGUS SKEW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DIRECT DRIVE DIAMETER mm/in…
  • Page 70
    Components Data — Cooling Only (R410A) A5WM 10G A5WM 15G INDOOR UNIT M5WM 010G M5WM 015G MODEL A5LC 10C A5LC 15C OUTDOOR UNIT M5LC 010C M5LC 015C TYPE ANTI FUNGUS SKEW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DIRECT DRIVE DIAMETER mm/in…
  • Page 71
    Components Data — Cooling Only (R410A) A5WM 20G A5WM 25G INDOOR UNIT M5WM 020G M5WM 025G MODEL A5LC 20C A5LC 25C OUTDOOR UNIT M5LC 020C M5LC 025C TYPE ANTI FUNGUS SKEW FAN QUANTITY ACRYLO NITRILE STYRENE MATERIAL INDOOR FAN DIRECT DRIVE DIAMETER mm/in…
  • Page 72
    Components Data — Cooling Only (R410A) A5WM 311 INDOOR UNIT M5WM 031F MODEL A5LC 28C OUTDOOR UNIT M5LC 028C TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE…
  • Page 73
    Components Data — Heatpump (R410A) A5WM 07GR A5WM 09GR INDOOR UNIT M5WM 007GR M5WM 009GR MODEL A5LC 07CR A5LC 10CR OUTDOOR UNIT M5LC 007CR M5LC 010CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER…
  • Page 74
    Components Data — Heatpump (R410A) A5WM 10GR A5WM 15GR INDOOR UNIT M5WM 010GR M5WM 015GR MODEL A5LC 10CR A5LC 15CR OUTDOOR UNIT M5LC 010CR M5LC 015CR TYPE ANTI FUNGUS SKEW FAN CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER…
  • Page 75
    Components Data — Heatpump (R410A) A5WM 20GR AWM 25GR INDOOR UNIT M5WM 020GR M5WM 025GR MODEL A5LC 20CR ALC 25CR OUTDOOR UNIT M5LC 020CR M5LC 025CR TYPE CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 108/4.25 LENGTH…
  • Page 76
    Components Data — Heatpump (R410A) A5WM 311R INDOOR UNIT M5WM 030FR MODEL A5LC 28CR OUTDOOR UNIT M5LC 028CR TYPE ANTI FUNGUS CROSS FLOW FAN QUANTITY MATERIAL ACRYLO NITRILE STYRENE INDOOR FAN DRIVE DIRECT DIAMETER mm/in 106 / 4.17 LENGTH mm/in 950 / 37.4 TYPE INDUCTION…
  • Page 77: Performance Data

    6. PERFORMANCE DATA Interpolation and Extrapolation method can be used to get the total capacity, TC and sensible capacity, SC at those temperatures which are not stated out in the table. Example: Model: AWM 10G / ALC 10C Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Solution: Overall…

  • Page 78
    Details: Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 24°C DB, 15°C WB Outdoor Condition: 35°C DB Outdoor DB ° C Indoor DB Indoor WB ° C ° C TC (kW) SC (kW) 2.623 1.892 2.687 1.794 Total capacity, TC…
  • Page 79
    Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 35°C DB Outdoor DB ° C Indoor DB Indoor WB ° C ° C TC (kW) SC (kW) 2.558 1.403 2.558 1.990 Total capacity, TC ⇒…
  • Page 80
    Step: To obtain the Total capacity and Sensible capacity for (a) Indoor Condition: 23°C DB, 15°C WB Outdoor Condition: 37°C DB Outdoor DB ° C Indoor DB Indoor WB ° C ° C TC (kW) SC (kW) TC (kW) SC (kW) TC (kW) SC (kW) 2.558…
  • Page 81: Performance Tables

    R22 Models (Cooling Only) MODEL : AWM 07G / ALC 07C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.418 1.484 2.249 1.335 2.080 1.186 1.910 1.037 1.741 0.889 1.538 0.710 2.453 1.349…

  • Page 82
    R22 Models (Cooling only) MODEL : AWM 10G / ALC 10C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.169 1.968 2.966 1.780 2.762 1.592 2.558 1.403 2.355 1.215 2.111 0.989 3.206 1.800…
  • Page 83
    R22 Models (Cooling only) MODEL : AWM 20G / ALC 18C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.954 3.645 5.566 3.311 5.179 2.977 4.791 2.642 4.404 2.308 3.939 1.907 6.132 3.309…
  • Page 84
    R22 Models (Cooling only) MODEL : AWM 25G / ALC 25C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.657 5.145 7.196 4.692 6.735 4.238 6.275 3.785 5.814 3.331 5.261 2.787 7.728 4.693…
  • Page 85: Cooling Mode

    R22 Models (Heatpump) MODEL : AWM 09GR / ALC 09CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.163 2.063 2.934 1.852 2.705 1.641 2.476 1.430 2.247 1.219 1.972 0.966 3.205…

  • Page 86
    R22 Models (Heatpump) MODEL : AWM 10GR / ALC 10CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.169 1.968 2.966 1.780 2.762 1.592 2.558 1.403 2.355 1.215 2.111 0.989 3.206…
  • Page 87
    R22 Models (Heatpump) MODEL : AWM 15GR / ALC 15CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.852 2.383 3.608 2.179 3.365 1.974 3.121 1.769 2.877 1.564 2.584 1.318 4.062…
  • Page 88
    R22 Models (Heatpump) MODEL : AWM 20GR / ALC 18CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.954 3.645 5.566 3.311 5.179 2.977 4.791 2.642 4.404 2.308 3.939 1.907 6.132…
  • Page 89
    R22 Models (Heatpump) MODEL : AWM 20GR / ALC 20CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.778 3.640 5.473 3.396 5.169 3.153 4.864 2.909 4.559 2.666 4.194 2.373 6.026…
  • Page 90
    R22 Models (Heatpump) MODEL : AWM 25GR / ALC 25CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.657 5.145 7.196 4.692 6.735 4.238 6.275 3.785 5.814 3.331 5.261 2.787 7.728…
  • Page 91
    R22 Models (Heatpump) MODEL : AWM 311R / ALC 28CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 8.187 5.330 7.772 4.967 7.356 4.604 6.941 4.241 6.525 3.877 6.026 3.441 8.441…
  • Page 92
    R410A Models (Cooling only) MODEL : A5WM 07G / A5LC 07C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.541 1.631 2.345 1.434 2.152 1.241 1.959 1.048 1.766 0.854 1.535 0.623 2.588 1.515…
  • Page 93
    R410A Models (Cooling only) MODEL : A5WM 10G / A5LC 10C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.028 1.998 2.824 1.793 2.631 1.600 2.439 1.407 2.247 1.215 2.016 0.983 3.110 1.857…
  • Page 94
    R410A Models (Cooling only) MODEL : A5WM 20G / A5LC 20C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.147 3.507 4.918 3.236 4.654 3.002 4.390 2.769 4.126 2.535 3.809 2.255 5.349 3.308…
  • Page 95
    R410A Models (Cooling only) MODEL : A5WM 311 / A5LC 28C Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.648 4.989 7.255 4.595 6.798 4.252 6.341 3.908 5.884 3.565 5.336 3.153 7.911 4.701…
  • Page 96
    R410A Models (Heatpump) MODEL : A5WM 07GR / A5LC 07CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.247 1.520 2.115 1.388 1.997 1.269 1.878 1.151 1.760 1.032 1.618 0.890 2.329…
  • Page 97
    R410A Models (Heatpump) MODEL : A5WM 09GR / A5LC 10CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 2.779 1.868 2.617 1.706 2.474 1.562 2.330 1.419 2.187 1.275 2.014 1.102 2.868…
  • Page 98
    R410A Models (Heatpump) MODEL : A5WM 10GR / A5LC 10CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.107 2.083 2.884 1.859 2.669 1.644 2.455 1.429 2.241 1.214 1.983 0.956 3.179…
  • Page 99
    R410A Models (Heatpump) MODEL : A5WM 15GR / A5LC 15CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 3.618 2.383 3.422 2.162 3.193 1.960 2.965 1.757 2.736 1.555 2.461 1.312 3.728…
  • Page 100
    R410A Models (Heatpump) MODEL : A5WM 20GR / A5LC 20CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.147 3.507 4.918 3.236 4.654 3.002 4.390 2.769 4.126 2.535 3.809 2.255 5.349…
  • Page 101
    R410A Models (Heatpump) MODEL : A5WM 25GR / A5LC 25CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.276 4.244 5.917 3.885 5.599 3.567 5.282 3.250 4.964 2.932 4.583 2.551 6.510…
  • Page 102
    R410A Models (Heatpump) MODEL : A5WM 311R / A5LC 28CR COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.648 4.989 7.255 4.595 6.798 4.252 6.341 3.908 5.884 3.565 5.336 3.153 7.911…
  • Page 103
    R410A Models (Cooling only) MODEL : A5WM 20G / A5LC 20C (3 PHASE) Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.206 3.550 4.976 3.280 4.711 3.049 4.447 2.818 4.182 2.587 3.864 2.310…
  • Page 104
    R410A Models (Cooling only) MODEL : A5WM 311 / A5LC 28C (3 PHASE) Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.648 4.989 7.255 4.595 6.798 4.252 6.341 3.908 5.884 3.565 5.336 3.153…
  • Page 105
    R410A Models (Heatpump) MODEL : A5WM 20GR / A5LC 20CR (3 PHASE) COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 5.206 3.550 4.976 3.280 4.711 3.049 4.447 2.818 4.182 2.587 3.864…
  • Page 106
    R410A Models (Heatpump) MODEL : A5WM 25GR / A5LC 25CR (3 PHASE) COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 6.762 4.377 6.391 3.963 5.957 3.582 5.523 3.202 5.089 2.821 4.568…
  • Page 107
    R410A Models (Heatpump) MODEL : A5WM 311R / A5LC 28CR (3 PHASE) COOLING MODE Outdoor DB°C ID DB°C ID WB°C TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) TC(kW) SC(kW) 7.648 4.989 7.255 4.595 6.798 4.252 6.341 3.908 5.884 3.565 5.336…
  • Page 108: Dimensional Data

    7. DIMENSIONAL DATA INDOOR UNIT MODEL : AWM 07G / 07GR / 09G / 09GR A5WM 07G / 07GR / 09G / 09GR Note : Dimension in mm OUTDOOR UNIT MODEL : ALC 09C / 09CR A5LC 07C / 07CR Note : Dimension in mm Downloaded from AC-Manual.com Manuals…

  • Page 109
    INDOOR UNIT MODEL : AWM 10G / 10GR / 15G / 15GR A5WM 10G / 10GR / 15G / 15GR Note : Dimension in mm OUTDOOR UNIT MODEL : ALC 10C / 10CR / 15C / 15CR A5LC 10C / 10CR / 15C / 15CR Note : Dimension in mm Downloaded from AC-Manual.com Manuals…
  • Page 110: Indoor Unit

    INDOOR UNIT MODEL : AWM 20G / 20GR / 25G / 25GR A5WM 20G / 20GR / 25G / 25GR Note : Dimension in mm OUTDOOR UNIT MODEL : ALC 18C / 20C / 20CR / 25C / 25CR A5LC 20C / 20CR / 25C / 25CR For A5LC / ALC 25 C/CR Note : Dimension in mm MODEL…

  • Page 111
    INDOOR UNIT MODEL : A5WM 311 / 301R Note : Dimension in mm OUTDOOR UNIT MODEL : A5LC 28C / 28CR For M5LC / MLC 028 C/CR Only Note : Dimension in mm MODEL ALC 28C/28CR A5LC 28C/28CR Downloaded from AC-Manual.com Manuals…
  • Page 112: Electrical Data

    8. ELECTRICAL DATA AWM 07G AWM 09G INDOOR UNIT MWM 007G MWM 009G MODEL ALC 07C ALC 09C OUTDOOR UNIT MLC 007C MLC 009C INSULATION GRADE POWER SOURCE V/Ph/Hz 220-240/1/50 220-240/1/50 RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.11 0.11 MOTOR OUTPUT POLES…

  • Page 113
    AWM 20G AWM 20G INDOOR UNIT MWM 020G MWM 020G MODEL ALC 18C ALC 20C OUTDOOR UNIT MLC 018C MLC 020C INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR 0.22 RATED RUNNING CURRENT MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz…
  • Page 114
    AWM 09GR MWM 009GR INDOOR UNIT MODEL ALC 09CR MLC 009CR OUTDOOR UNIT INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR 0.11 RATED RUNNING CURRENT MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER OUTDOOR MOTOR RATED RUNNING CURRENT 0.18…
  • Page 115
    AWM 20GR AWM 20GR INDOOR UNIT MWM 020GR MWM 020GR MODEL ALC 18CR ALC 20CR OUTDOOR UNIT MLC 018CR MLC 020CR INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR 0.22 RATED RUNNING CURRENT MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz…
  • Page 116
    A5WM 07G A5WM 09G INDOOR UNIT M5WM 007G M5WM 009G MODEL A5LC 07C A5LC 10C OUTDOOR UNIT M5LC 007C M5LC 010C INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR 0.11 RATED RUNNING CURRENT MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz…
  • Page 117
    A5WM 20G A5WM 25G INDOOR UNIT M5WM 020G M5WM 025G MODEL A5LC 20C A5LC 25C OUTDOOR UNIT M5LC 020C M5LC 025C INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.29 MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE…
  • Page 118
    A5WM 07GR A5WM 09GR INDOOR UNIT M5WM 007GR M5WM 009GR MODEL A5LC 07CR A5LC 10CR OUTDOOR UNIT M5LC 007CR M5LC 010CR INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR 0.11 RATED RUNNING CURRENT MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz…
  • Page 119
    A5WM 20GR A5WM 25GR INDOOR UNIT M5WM 020GR M5WM 025GR MODEL A5LC 20CR A5LC 25CR OUTDOOR UNIT M5LC 020CR M5LC 025CR INSULATION GRADE 220-240/1/50 POWER SOURCE V/Ph/Hz RATED INPUT POWER INDOOR MOTOR RATED RUNNING CURRENT 0.22 0.29 MOTOR OUTPUT POLES INSULATION GRADE 220-240/1/50 POWER SOURCE…
  • Page 120: Wiring Diagrams

    9. WIRING DIAGRAMS COOLING ONLY MODELS OUTDOOR UNIT MODEL : ALC 09C / 010C , A5LC 07C / 10C / 15C INDOOR UNIT MODEL : AWM 09G / 10G , A5WM 07G / 09G / 10G / 15G (WITH IONIZER) Downloaded from AC-Manual.com Manuals…

  • Page 121
    COOLING ONLY MODELS OUTDOOR UNIT MODEL : ALC 15C INDOOR UNIT MODEL : AWM 15G (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 122
    COOLING ONLY MODELS OUTDOOR UNIT MODEL : ALC / A5LC 20C / 25C INDOOR UNIT MODEL : AWM / A5WM 20G / 25G (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 123
    COOLING ONLY MODELS OUTDOOR UNIT MODEL : ALC 18C INDOOR UNIT MODEL : AWM 20G (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 124
    COOLING ONLY MODELS OUTDOOR UNIT MODEL : ALC 28C, A5LC 28C INDOOR UNIT MODEL : AWM 311, A5WM 311 Downloaded from AC-Manual.com Manuals…
  • Page 125
    HEATPUMP MODELS OUTDOOR UNIT MODEL : ALC 09CR / 10CR , A5LC 07CR / 10CR / 15CR INDOOR UNIT MODEL : AWM 09GR / 10GR , A5WM 07GR / 10GR / 15GR (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 126
    HEATPUMP MODELS OUTDOOR UNIT MODEL : ALC 15CR INDOOR UNIT MODEL : AWM 15GR (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 127
    HEATPUMP MODELS OUTDOOR UNIT MODEL : ALC / A5LC 20CR / 25CR INDOOR UNIT MODEL : AWM / A5WM 20GR / 25GR (WITH IONIZER) Downloaded from AC-Manual.com Manuals…
  • Page 128
    HEATPUMP MODELS OUTDOOR UNIT MODEL : ALC 28CR, A5LC 28CR INDOOR UNIT MODEL : AWM 301R, A5WM 301R Downloaded from AC-Manual.com Manuals…
  • Page 129: Servicing And Maintenance

    10. SERVICING AND MAINTENANCE Off the unit Unscrew the air discharge housing Flip open the air discharge housing Clean the blower Close the air discharge housing and tighten it with screw The unit is designed to give a long life operation with minimum maintenance required. However, it should be regularly checked and the following items should be given due attention.

  • Page 130
    PRE START UP MAINTENANCE (AFTER EXTENDED SHUTDOWN) – Inspect thoroughly and clean indoor and outdoor units. – Clean or replace air filters. – Clean condensate drain line. – Clean clogged indoor and outdoor coils. – Check fan imbalance before operation. –…
  • Page 131: Troubleshooting

    11. TROUBLESHOOTING When a malfunction of the air conditioner unit is detected, immediately switch off the main power supply before proceeding with the following troubleshooting procedures. The following are common fault conditions and simple troubleshooting tips. If any other fault conditions which are not listed occur, contact your nearest local dealer.

  • Page 132
    Diagnostic Guidelines By means of pressure reading: Pressure Data Probable cause Circuit High side ● 1. Overcharged with refrigerant. Low side ● 2. Non-condensable gases in refrigerant circuit (e.g. air) 3. Obstructed air-intake / discharge. 4. Hot air short circuiting in outdoor unit. High side ●…
  • Page 133
    By means of diagnostic flow chart: Generally, there are two kinds of problems, i.e. starting failure and insufficient cooling/heating. “Starting failure” is caused by electrical defect while improper application or defects in refrigerant circuit causes “Insufficient cooling / heating”. i) Diagnosis of Electric Circuit The most common causes of air conditioner failure to “start”…
  • Page 134
    ii ) Diagnosis of Refrigerant Circuit / Application There might be some causes where the unit starts running but does not perform satisfactorily, i.e. insufficient cooling. Judgement could be made by measuring temperature difference of indoor unit’s intake and discharge air as well as running current.
  • Page 135
    Satisfactory operation with temperature difference of air intake & discharge of indoor unit 14°C to 20°C. * ( * value is for reference only ) Downloaded from AC-Manual.com Manuals…
  • Page 136: Exploded View & Parts List

    12. EXPLODED VIEW AND PARTS LIST INDOOR UNIT MODEL: A5WM / AWM 07G / 07GR / 09G / 09GR / 10G / 10GR / 15G / 15GR Downloaded from AC-Manual.com Manuals…

  • Page 137
    A5WM / AWM 07G / 09G / 10G / 15G No Descriptions Part No No Descriptions Part No Assy., Chassis 12 Air Discharge Housing A5WM / AWM 07/09G R50124064147 A5WM / AWM 07/09G R50124062325 A5WM / AWM 10/15G R50124064151 A5WM / AWM 10/15G R50124062326 Fan, Motor 13 Lower Louver…
  • Page 138
    MODEL: A5WM / AWM 20G / 20GR / 25G / 25GR Downloaded from AC-Manual.com Manuals…
  • Page 139
    Model : A5WM / AWM 20G / 25G No Descriptions Part No No Descriptions Part No Assy., Chassis R50124068170 Drain Hose R10024015319 Fan, Motor Assy., Control Box R50044071955 AWM 20G R03034074205 10 Assy., Control Box Cover R50124071418 AWM 25G R03034074204 11 Assy., Front Cover R50124071425 Cross Flow Fan…
  • Page 140
    MODEL: AWM 30F / 30FR, A5WM 31F / 30FR Downloaded from AC-Manual.com Manuals…
  • Page 141
    MODEL : A5WM 311 / AWM 311 No Descriptions Part No No Descriptions Part No ASSY, INSTALLATION BRACKET R50014050721 11 ASSY, CONTROL BOX R50044090264 ASSY. CHASSIS R50124050703 12 LED LIGHT BRACKET R12014050679 PIPING CLAMP R07014024546 13 G12 HANDSET R04084065328 FAN BUSH BRACKET R12014050709 14 CONTROL BOX COVER R12014050681…
  • Page 142
    Model : ALC 07C No Descriptions Part No No Descriptions Part No ASSY,PAN BASE SL07C R50014057372 12 PANEL,LEFT R01014052510 COMPRESSOR, 2RS122D5BC02 PANEL,RIGHT R04019029041 R01014084434 Matsushita (SL07/09C/CR)(639.4FL) ASSY., OUTDOOR COIL — (5)SL09C 14 ASSY,CONTROL PANEL SL07C R50044092695 R50024087206 7MM RL 15 PANEL,TOP/FRONT R01014052512 VALVE,BRACKET R01014051164…
  • Page 143
    Model : ALC 09C No Descriptions Part No No Descriptions Part No ASSY,PAN BASE SL07C R50014057372 10 PANEL,LEFT R01014052510 ASSY., OUTDOOR COIL — (5)SL09C PANEL,RIGHT R50024087206 R01014084434 7MM RL (SL07/09C/CR)(639.4FL) VALVE BRACKET R01014051164 12 ASSY,CONTROL PANEL SL09C R50044089886 COMPRESSOR, 2PS156D3CB02 13 PANEL,TOP/FRONT R01014052512 R04019027628…
  • Page 144
    Model : ALC 10 / 15C No Descriptions Part No No Descriptions Part No ASSY,PAN BASE SL10/15C R50014051158 14 ASSY,VALVE COVER R50124051173 ASSY,OUTDOOR COIL SL15C/CR R50024087838 PANEL,TOP/FRONT R01014051171 COMPRESSOR, 2PS206D2AF02 R04019027709 ASSY,FRONT GRILLE (SL10C/15C) R50124056700 MATSUSHITA VALVE BRACKET R01014051164 FAN PROPELLER, DIA401.0 R03019015339 OZ42000 SHUNDE Assy, 2 way flare valve 1/4″…
  • Page 145
    Model : ALC 18 / 20C No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 13 PANEL TOP (SL20C/25C/28C/CR) R01014070596 ASSY,OUTDOOR COIL 7mm coil ASSY FRONT GRILLE R50124072880 (SL20C/25C/28C/CR) MLC 018C R50024089940 MLC 020C R50024084570 PLASTIC,HANDLE R12014057948 SL07C/09C/10C/15C/CR BRACKET MOTOR (SL20C/CR) R01014070601…
  • Page 146
    Model : ALC 25C No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 13 PANEL TOP (SL20C/25C/28C/CR) R01014070596 ASSY. OUTDOOR COIL (SL25C) ASSY FRONT GRILLE R50024089206 R50124072880 7MM COIL DIET (SL20C/25C/28C/CR) PLASTIC,HANDLE BRACKET MOTOR (SL25C/28C/CR) R01014070948 R12014057948 SL07C/09C/10C/15C/CR MOTOR, MSL25C-502-WL ASSY VALVE COVER…
  • Page 147
    Model: ALC 09CR No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014057372 10 Fan Blade R03019004131 Assy., Condenser Coil R50024064204 11 Left Panel R01014052510 Valve Bracket R01014051164 12 Right Panel R01014052509 Compressor 13 Assy. Control Panel R50044059032 ALC 09CR R50049016211 14 Assy., Front Panel…
  • Page 148
    Model: ALC 10CR / 15CR No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014051158 11 Left Panel R01014051166 Assy., Condenser Coil 12 Right Panel R01014051167 ALC 10CR R50024065601 13 Assy., Front Panel R01014051171 ALC 15CR R50024060071 14 Assy. Control Panel Valve Bracket R01014051164 ALC 10CR…
  • Page 149
    Model: ALC 18CR / 20CR No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 13 PANEL TOP (SL20C/25C/28C/CR) R01014070596 ASSY,OUTDOOR COIL 7mm coil ASSY FRONT GRILLE R50124072880 (SL20C/25C/28C/CR) ALC 18CR R50024090296 ALC 20CR R50024075143 PLASTIC,HANDLE R12014057948 SL07C/09C/10C/15C/CR BRACKET MOTOR (SL20C/CR) R01014070601 16 ASSY VALVE COVER (SL20C/CR)
  • Page 150
    Model: ALC 25CR No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 13 PANEL TOP (SL20C/25C/28C/CR) R01014070596 ASSY. OUTDOOR COIL(SL25CR)2 ASSY FRONT GRILLE R50024088731 R50124072880 ROW 7MM COIL (SL20C/25C/28C/CR) PLASTIC,HANDLE BRACKET MOTOR (SL25C/28C/CR) R01014070948 R12014057948 SL07C/09C/10C/15C/CR MOTOR, MSL25C-502-WL ASSY VALVE COVER R03039028207 R50124073905…
  • Page 151
    OUTDOOR UNIT MODEL: A5LC 07C No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014057372 10 Left Panel R01014052510 Assy., Condenser Coil R50024064720 11 Right Panel R01014052509 Valve Bracket R01014051164 12 Assy. Control Panel R50044054806 Compressor R04019019592 13 Assy., Front Panel R01014052512 Assy., Partition R50064065275…
  • Page 152
    Model: A5LC 10C / 15C No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014051158 11 Right Panel R01014051167 Assy., Condenser Coil R50024064721 12 Assy., Front Panel R01014051171 Valve Bracket R01014051164 13 Assy. Control Panel Compressor A5LC 10C R50044058195 A5LC 10C R04019019590…
  • Page 153
    MODEL: A5LC 20C No Descriptions Part No No Descriptions Part No Assy. Base Pan 10 Compressor ALC 18C R50014077978 ALC 18C R50049022614 A5LC/ALC 20C R50014013884 ALC 20C R04019018334 Assy. Outdoor Coil A5LC 20C R04019021361 ALC 18C R50024077968 11 Front Panel, Left R01014070597 ALC 20C R50024070651…
  • Page 154
    MODEL: A5LC 25 / 28C No Descriptions Part No No Descriptions Part No Assy. Base Pan R50014073884 11 Front Panel, Left R01014070947 Assy. Outdoor Coil 12 Service Panel R01014070949 ALC 25C/28C R50024070959 13 Terminal Cover Panel R01014070838 A5LC 25C/28C R50024079238 14 Assy.
  • Page 155
    MODEL: A5LC 07CR No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014057372 12 Right Panel R01014052509 Assy., Condenser Coil R50024064720 13 Assy. Control Panel R50044059032 Valve Bracket R01014051164 14 Assy., Front Panel R01014052512 Compressor R04019019592 15 Assy., Valve Cover R50124055172 Assy., Partition R50064065275…
  • Page 156
    Model: A5LC 10CR / 15CR No Descriptions Part No No Descriptions Part No Assy., Base Pan R50014051158 11 Left Panel R01014051166 Assy., Condenser Coil 12 Right Panel R01014051167 A5LC 10CR R50024064721 13 Assy., Front Panel R01014051171 A5LC 15CR R50024066517 14 Assy. Control Panel Valve Bracket R01014051164 A5LC 10CR…
  • Page 157
    MODEL: A5LC 20CR No Descriptions Part No No Descriptions Part No Assy. Base Pan R50014073884 11 Front Panel, Left R01014070597 Assy. Outdoor Coil 12 Service Panel R01014070598 ALC 20CR R50024077089 13 Terminal Cover Panel R01014070838 A5LC 20CR R50024075143 14 Assy. Control Panel Motor Bracket R01014070601 ALC 20CR…
  • Page 158
    MODEL: A5LC 25CR / 28CR No Descriptions Part No No Descriptions Part No Assy. Base Pan R50014073884 11 Front Panel, Left R01014070947 Assy. Outdoor Coil 12 Service Panel R01014070949 ALC 25CR/28CR R50024077092 13 Terminal Cover Panel R01014070838 A5LC 25CR/28CR R50024075147 14 Assy.
  • Page 159
    Model : A5LC 20C (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 PLASTIC,HANDLE R12014057948 SL07C/09C/10C/15C/CR ASSY,OUTDOOR COIL R50024079078 (5SL20C)2RX28THX18FPI 15 ASSY VALVE COVER (SL20C/CR) R50124072885 BRACKET MOTOR (SL20C/CR) R01014070601 16 ASSY,CAPILLARY TUBE (5SL20C) R50024081921 MOTOR, MSL20C/25C-501 64W 17 PARTITION (SL20C/CR) R01014070603…
  • Page 160
    Model : A5LC 25C (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY VALVE COVER ASSY PAN BASE (SL20/25/28C(R)) R50014073884 R50124073905 (SL25C/28C/CR) ASSY,OUTDOOR COIL ASSY,CAPILLARY TUBE (5SL25C- R50024079238 R50024092169 (5SL25C)2RX34THX18FPI 3PHASE) BRACKET MOTOR (SL25C/28C/CR) R01014070948 17 PARTITION (SL25C/28C/CR) R01014070951 MOTOR, MSL20C/25C-501 64W PLASTIC HANDLE FRONT…
  • Page 161
    Model : A5LC 28C (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY VALVE COVER ASSY PAN BASE (SL20/25/28C(R)) R50014073884 R50124073905 (SL25C/28C/CR) ASSY,OUTDOOR COIL R50024079238 16 ASSY,CAPILLARY TUBE (5SL28C) R50024079593 (5SL25C)2RX34THX18FPI 17 PARTITION (SL25C/28C/CR) R01014070951 BRACKET MOTOR (SL25C/28C/CR) R01014070948 PLASTIC HANDLE FRONT R12014070955…
  • Page 162
    Model : A5LC 20CR (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY,PAN BASE (5SL20C/CR) R50014078281 15 ASSY VALVE COVER (SL20C/CR) R50124072885 ASSY,OUTDOOR COIL (5SL20C/CR- R50024075143 16 ASSY,CAPILLARY TUBE (5SL20CR) R50024081904 2RX28TH) BRACKET MOTOR (SL20C/CR) R01014070601 ASSY,TUBING 4-WAY VALVE R50024080655 (5SL20CR) MOTOR,YDK64-6C/MSL25C-501-…
  • Page 163
    Model : A5LC 25CR (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY VALVE COVER ASSY PAN BASE (SL20/25/28C(R)) R50014073884 R50124073905 (SL25C/28C/CR) ASSY. OUTDOOR COIL ASSY,CAPILLARY TUBE (5SL25CR- R50024075147 R50024092178 (5SL25CR/28CR) 3PHASE) ASSY,TUBING 4-WAY VALVE BRACKET MOTOR (SL25C/28C/CR) R01014070948 R50024080572 (5SL25CR)
  • Page 164
    Model : A5LC 28CR (3 PHASE) No Descriptions Part No No Descriptions Part No ASSY VALVE COVER ASSY PAN BASE (SL20/25/28C(R)) R50014073884 R50124073905 (SL25C/28C/CR) ASSY. OUTDOOR COIL ASSY,CAPILLARY TUBE (5SL25CR- R50024075147 R50024092178 (5SL25CR/28CR) 3PHASE) 17 ASSY, TUBING 4WV (5SL28CR) R50024080540 BRACKET MOTOR (SL25C/28C/CR) R01014070948 18 ASSY PARTITION (SL25C/28C/CR)
  • Page 165
    While upmost care is taken in ensuring that all details in the publication are correct at time of going to press, we are constantly striving for improvement and therefore reserve the rights to alter model specifications and equipment without prior notice. Details of specifications andequipment are also subject to change to suit local conditions and equirements and not all models are available in every market.

На чтение 6 мин Просмотров 2.1к. Опубликовано 16.10.2017 Обновлено 15.05.2018

Торговая марка Acson принадлежит малазийской компании «O.Y.L. Manufacturing Company». Товары бренда появились на российском рынке сравнительно недавно, но уже успели зарекомендовать себя как качественная, современная, надежная продукция. Кондиционеры данной марки можно купить на территории 50 мировых стран.

Наиболее приоритетная задача производителя – реализация программы, основанной на постоянном совершенствовании качества готовой продукции при максимальном снижении конечной цены. Такая политика компании никоим образом не отражается на качестве изделий и закупаемых комплектующих. Уже долгое время Аксон сотрудничает исключительно с проверенными поставщиками, зарекомендовавшими себя на мировом рынке бытовой и производственной техники: Copeland, Matsushita, Bristol.

Содержание

  1. Основные линейки кондиционеров
  2. Кассетные системы кондиционирования
  3. Наполно-потолочные модели кондиционеров
  4. Канальные мультисплит
  5. Бытовые системы кондиционирования
  6. Сравнение характеристик популярных моделей
  7. Инструкции к пульту управления и кондиционерам Acson
  8. Коды ошибок кондиционеров Acson
  9. Отзывы пользователей

Основные линейки кондиционеров

Производитель, безусловно, заинтересован в привлечении как можно большего количества новых клиентов, поэтому постоянно расширяет и дополняет линейки выпускаемых сплит-систем. Благодаря продуманной рыночной стратегии бренд Эксон укрепил позиции не только в Малайзии, но в Европе, России, странах бывшего СНГ. Климатическая техника марки встречается в 80 странах, благодаря расширенной сети дистрибьюторов.

Сплит-системы Acson выпускаются в нескольких вариантах в зависимости от предназначения:

  1. Мини-чиллеры.
  2. Фанкойл.
  3. Канальные мультисплит средней и увеличенной мощности.
  4. Широкий модельный ряд кондиционеров Аксон бытового назначения.

Климатическое оборудование разрабатывается и производится на объектах компании «O.Y.L. Manufacturing Company Sdn. Bhd.» (O.Y.L.). В производственные ресурсы предприятия входят несколько современных заводов, работающих на базе последних технологий и научных инноваций. Марка располагает более 10 психометрических испытательных лабораторий и собственным исследовательско-конструкторским центром (R&D Center), являющимся крупнейшим в Юго-Восточной Азии.

Кассетные системы кондиционирования

Установка кондиционера кассетного типа осуществляется в подвесные потолки. После предварительной разметки конструкции фиксируются подвесными стержнями и анкерными гайками. При выборе подобной модели не менее важно правильно установить дренажную систему и отрегулировать трубный зажим. В комплект кассетного кондиционера входят:

  • одна из реверсивных моделей внутреннего блока;
  • наружный блок;
  • проводной (беспроводной) пульт к кондиционеру Acson.

В зависимости от мощности отдельно взятой модели, такие «кассетники» справятся с помещением площадью до 50 м2. Последние модели кассетных установок оснащены одновременно ионизирующим, антибактериальным и дезодорирующим фильтрами. Подключенные кондиционеры возможно объединить в одну сеть с дистанционным пультовым управлением.

Наполно-потолочные модели кондиционеров

Отличие линейки напольно-потолочного оборудования в том, что установка внутреннего блока допустима как на стеновой поверхности (под потолком), так и на полу. Как и большинство моделей, система отлично справляется с охлаждением и обогревом, позволяя в минимальные сроки добиться оптимальных показателей микроклимата. Модели напольно-подпотолочных конструкций выпущены в двух сериях: «C» и «D». Основными характеристиками подобных кондиционеров являются:

  • создание комфортных условий на площади до 160 м2;
  • потребление мощности в 3 кВт и выше рассчитано на однофазную и трехфазную сеть;
  • оповещение о действующем режиме и возникшей неисправности посредством светодиодного блока;
  • имеется «турбо»-режим, позволяющий создать желаемый микроклимат всего за 20 минут.

Сплит-системы относятся к оборудованию промышленного и полупромышленного назначения. Климатические устройствам из этой категории значительно превосходят своих собратьев по стоимости, но и гораздо мощнее их. Таким образом, установка способна эффективно функционировать в пределах помещений, общей площадью 80-160 м2.

Канальные мультисплит

Выпускаются в сериях «ACC» и «ALS». Имеют встроенное микропроцессорное управление. Отличаются следующим:

  • наличие четырех мощностей работы;
  • обслуживание объектов площадью от 28 м2 до 67 м2;
  • вентиляторный двигатель работает на четырех скоростях.

Устройства призваны создать не только комфортные температурные условия, но и оптимальный уровень влажности. Канальные приборы в количестве до 4-х внутренних блоков допустимо подключать к одному внешнему. При этом каждый из подключенных приборов может быть оснащен встроенным ионизатором воздуха и плазменным фильтром.

Бытовые системы кондиционирования

Компания учитывает пожелания своих клиентов и старается расширить линейку выпускаемых бытовых кондиционеров. В данный момент в линейке настенных мультисплит есть модели:

  • инверторного типа;
  • кондиционеры серии «On/Off»;
  • отдельная линейка приборов, работающая только на охлаждение.

Инверторные мультисплит рассчитаны на варианты рабочего режима на охлаждение и обогрев. Кроме этого, «inverter»-системы оснащены режимом вентиляции, поддержанием достигнутой температуры в режиме «auto». Кондиционеры с обозначением «inverter» эффектны в помещениях до 30-35 м2 и способны безопасно функционировать при внешней температуре в -15°С.

Серия сплит-систем серии «On/Off» призваны работать как в режимах охлаждение/обогрев, так и только на охлаждение. Отличаются следующими характеристиками:

  • наличие таймера включения/отключения;
  • опция дезодорирующего фильтра;
  • возможность регулирования скорости работы вентилятора;
  • функция запоминания выполненных настроек.

Настенные мультисплит в зависимости от модели способны обслуживать от 20 до 65 м2, при этом не только меняя температуру, но и придавая воздуху кристальную свежесть. Большинство последних линеек кондиционеров (как и инверторных, так и «on/off») оснащены высокоэффективной трехступенчатой системой фильтрации и плазменным стерилизатором. Такая обработка поступающих воздушных масс полностью избавляет их от вредных примесей, бактерий и опасных для человека вирусов.

Сравнение характеристик популярных моделей

Техническая характеристика Наименование модели
A5WMY10LR A5WM15G2R RCM50DR
Воздушный поток, м3/мин 9,78 9,78 22,3
Мощность охлаждения, Вт 2550 3520 14068
Мощность обогрева, Вт 2840 3520 14068
Потребление при охлаждении, Вт 730 1230 5115
Потребление при обогреве, Вт 700 1080 4517
Уровень шума (max), дБ 40 42 58
Обслуживаемая площадь (max), м2 25-30 50 140

Инструкции к пульту управления и кондиционерам Acson

Ко всем кондиционерам марки Acson прилагается инструкция. Данное руководство предоставляет покупателю такие сведения, как:

  • рекомендации по монтажу и подключению приборов;
  • основные правила по эксплуатации;
  • техническое обслуживание системы и устранение возникших неполадок.

Помимо схематичного изображения сплит-систем с обозначением элементов, в буклет входит и подробная инструкция к пульту. В данном разделе инструкции полностью разъясняется значение каждой кнопки дистанционного устройства и значков, отображаемых на дисплее.

Коды ошибок кондиционеров Acson

Все модели Аксон оснащены высокоэффективной системой самодиагностики. Такая дополнительная функция не только контролирует работу прибора, но и защищает его. По завершении самодиагностики неисправностей на дисплее устройства высвечиваются коды ошибок. Каждый код ошибки указывает на конкретную причину сбоя.

Отзывы пользователей

При использовании оборудования Acson покупателя отмечают такие «плюсы», как:

  • абсолютная бесшумность устройств;
  • простота управления и настройки режимов;
  • минимальное техническое обслуживание;
  • высокая производительность.

Согласно отзывам, широкий модельный ряд товаров позволяет подобрать оптимально подходящую модель в зависимости от строения и площади обслуживаемого объекта.

В настоящее время вы находитесь на странице с руководствами Acson кондиционер. Выберите один из продуктов, чтобы сразу перейти к руководству по этому продукту. Не можете найти Acson ? Тогда попробуйте вбить в поле поиска Acson и модель, чтобы найти нужное руководство Acson. На ManualsPDF.ru в настоящее время имеется 38 руководств Acson . Самые популярные Acson кондиционер:

  • Acson GS02
  • Acson G12
  • Acson AWM 301

Последнее добавленное руководство Acson было добавлено 2017-12-05, и это Acson A5CM 15 E.

В настоящее время вы находитесь на странице с руководствами Acson кондиционер. Выберите один из продуктов, чтобы сразу перейти к руководству по этому продукту. Не можете найти Acson ? Тогда попробуйте вбить в поле поиска Acson и модель, чтобы найти нужное руководство Acson. На ManualsPDF.ru в настоящее время имеется 38 руководств Acson . Самые популярные Acson кондиционер:

  • Acson GS02
  • Acson G12
  • Acson AWM 10G-GR

Последнее добавленное руководство Acson было добавлено 2017-12-05, и это Acson A5CM 15 E.

Приветствую всех на сайте Кондиционерщик! Сегодня я постараюсь написать наиболее понятную инструкцию по управлению бытовой сплит-системой. Надеюсь, что после прочтения каждый пользователь сможет управлять абсолютно любым кондиционером.

Значки на кондиционереПеред включением «сплита» убедитесь, что температура на улице соответствует его условиям эксплуатации. Если для вашей модели вы не знаете допустимых уличных температур, то не рекомендую включать прибор при температуре на улице ниже нуля градусов. Подробнее об этом читайте здесь.

Начну с того, что для использования кондиционера он должен быть подключен к сети. Обычно он подключается или вилкой в розетку или через «автомат» в электрическом щитке. При подаче «питания» на прибор вы услышите звуковой сигнал от внутреннего блока или увидите разовое открытие/закрытие жалюзи. Если электропитание не поступает, то читайте возможные причины.

P.S. Бывает, что некоторые кондиционеры автоматически включаются после подачи «питания» – в этом нет ничего страшного. Просто продолжайте его настраивать по инструкции.

Далее берем в руки пульт…Кнопки кондиционера

Инструкция к пульту кондиционера – что означают кнопки и значки

Расположу все функции и кнопки в порядке важности от часто нажимаемых к редко используемым.

  1. Чтобы включить кондиционер нужно один раз нажать кнопку «on/off» – обычно это самая большая выделенная ярким цветом кнопка.Значок включения/выключения

Возможно, после нажатия кнопки прибор запустится не сразу (это зависит от выбранного режима и температуры).

  1. Чтобы включить нужный режим есть кнопка «Mode» (может быть отображена на пульте в виде нескольких маленьких значков – снежинка/солнышко/капелька). При её нажатии режимы кондиционера переключаются последовательно. В большинстве приборов 5 режимов:
  • автоматический (надпись «auto» или значок «треугольника» или другое);
  • охлаждение (надпись «cool» или значок «снежинка»);
  • обогрев (надпись «heat» или значок «солнышко»);
  • осушение (надпись «dry» или значок «капелька»);
  • вентилирование (надпись «fan» или значок «вентилятора» — важно не путать режим «fan» с кнопкой регулировки скорости «fan»).Значок на кнопке переключения режимов

После включения нужного режима важно подождать 5-10 минут пока «кондёр» перестроится.

P.S. Редко попадаются пульты, где режимы включаются не кнопкой Mode, а отдельными кнопками режимов – Cool, Heat, Dry и прочее.

  1. Чтобы настроить температуру на каждом пульте есть кнопки «Temp». Они могут быть в виде «стрелок» или значков «+»/«-».Значки регулировки температуры в комнате

Принцип работы простой – какую температуру настроили на пульте, такую кондиционер будет поддерживать в комнате. Например, если настроили 25, то далее прибор будет стараться поддерживать в помещении +25 градусов (многие ошибочно думают что чем выше цифра, тем холоднее прибор будет дуть – это неверно!!!)

P.S.

  • Конечно, если кондиционер неправильно рассчитан, то он никогда не добьется нужной температуры.
  • На некоторых моделях настроенная цифра автоматически меняется на текущую температуру в комнате – не путайтесь!!!
  • Кондиционер не будет холодить, если на пульте вы настроили 25, а в комнате, допустим, уже 24 градуса. Тоже касается и режима обогрева (прибор не будет греть, если в комнате нужная температура уже достигнута).
  1. Чтобы изменить скорость потока воздуха из внутреннего блока нужно найти кнопку «Fan speed» (это может быть просто «Fan» или просто «Speed», или значок «вентилятора»).Значок настройки скорости вентилятора

На дисплее скорость вращения вентилятора отображается в виде шкалы или надписей low/med/high/auto (медленная/средняя/быстрая/автоматическая скорости). При настройке автоматической скорости прибор сам выбирает с какой скоростью в данный момент крутить вентилятор.

Настройка скорости не влияет на значение настроенной температуры (например, если настроили 25 градусов, то они же будут поддерживаться). Эта функция влияет лишь на быстроту охлаждения помещения (быстроту достижения заданной температуры).

Важно не путать регулировку скорости вращения вентилятора «Fan», и режим работы «Fan» (вентилирование – переключается при помощи кнопки «Mode»). Также не путаем автоматическую скорость вращения вентилятора с автоматическим режимом работы прибора («Auto» — переключается также при помощи кнопки «Mode»).

  1. Чтобы изменить направление потока воздуха нужно найти кнопку «Swing» или «Air flow» или «Air direction» (она может быть в виде значков «похожих на стрелки» или «похожих на скобки»).Значок настройки направления воздушного потока

Поток у любого кондиционера регулируется в двух направлениях –  вверх/вниз и вправо/влево. Вверх/вниз у любого кондиционера регулируется кнопкой на пульте. А вот вправо/влево может быть регулировка и в ручном виде (в этом случае будьте осторожны и лучше выключите кондиционер).

Вариаций работы кнопки «Swing» вверх/вниз бывает несколько:

  • бывает, что направление меняется в самом простом режиме (один раз нажали – шторки «плавают», второй раз нажали – шторки зафиксировались в любой точке амплитуды);
  • бывает, что направление меняется пошагово (один раз нажали – шторка на шаг передвинулась, второй раз нажали – шторки еще на шаг передвинулись и так далее);
  • бывает, что положение меняется, как показывает схематическое изображение на дисплее пульта.

Рекомендую с настройкой направления потока поэкспериментировать, чтобы найти самое безопасное положение (чтобы поток воздуха не дул на людей и на зоны отдых домочадцев – подробнее читайте здесь)

Это были основные кнопки, которые есть абсолютно на каждом пульте. Далее разберем дополнительные, более редкие кнопки и функции.

  1. Чтобы включить «режим сна» используются кнопки «Sleep» (так же может быть «Good sleep»). Алгоритм работы данной функции у всех кондиционеров разный, но объединяет их то, что вентилятор работает на самых медленных оборотах. В данном режиме может автоматически изменяться настроенная температура не более чем на 2 градуса – это происходит постепенно в течение нескольких часов. Связано это с фазами сна человека, чтобы температура ночью при засыпании, пробуждении и в фазе глубокого сна была наиболее комфортной и безопасной.Значок активации режима сна

На дисплее в режиме сна часто изображается значок «в виде луны». Подробнее как работает именно ваша модель при активации данной опции можно узнать только в инструкции по его эксплуатации (идет с документами к «сплиту»).

Примерно такую же функцию выполняет тихий режим «Quiet», только температура автоматически не изменяется.

  1. Чтобы максимально быстро охладить помещение используется так называемый «турбо режим». Кнопки на пульте имеют надписи «Turbo», «Jet», «Jet cool», «Powerful», «Hi power», или значок похожий на значок «ускоренного вентилятора». Чтобы активировать ускоренное охлаждение нужно один раз нажать соответствующую кнопку. После чего вентилятор внутреннего блока начинает вращаться с наибольшей скоростью. При достижении заданной температуры «турбо режим» автоматически отключается. Так же его можно отключить самостоятельно повторным нажатием кнопки.Значки Turbo на кондиционере
  2. Чтобы запрограммировать время включения или отключения прибора используется таймер. У разных кондиционеров кнопки настроек таймера отличаются. У каких-то моделей всего одна кнопка («Timer»), у каких-то моделей на настройку времени предусмотрен целый блок кнопок («Clock», «Timer on», «Timer off», «On», «Off», «Cancel», «Set» и различные стрелки). У таких моделей настройка интуитивно более понятна – нужно сначала настроить текущее время, затем время включения или отключения «кондёра». А в моделях, где всего одна кнопка «Таймер», функцию переключения времени выполняют стандартные кнопки (регулировки температуры, вентилятора и прочие).Значок таймера на кнопке пульта

В большинстве случаев настройка начинается с нажатия кнопки «Timer». А далее лучше пользоваться инструкцией для конкретной модели для настройки текущего времени, времени включения или отключения «сплита». Если инструкция утеряна, то попробуйте найти её в интернете. Крайний вариант это пытаться настроить время и таймер так называемым «методом тыка».

  1. Чтобы отключить подсветку индикации на внутреннем блоке, на некоторых пультах предусмотрена кнопка «Light» (так же может быть «Led display»). Эта функция просто отключает подсветку, если она раздражает, например, ночью. Ни на какие настройки отключение дисплея не влияет и кондиционер продолжает работать в настроенном режиме. Чтобы включить подсветку нужно повторно нажать на кнопку «Light».Значок отключения дисплей на внутреннем блоке
  2. Чтобы активировать функцию самоочистки внутреннего блока на некоторых моделях есть кнопка «Clean» (может быть «Auto clean», «X-fan», «Blow»). Смысл этой функции заключается в том, чтобы просушить детали внутреннего блока от влаги (таким образом предотвратить появление плесени). Работает эта опция после выключения сплит-системы – вентилятор внутреннего блока продолжает вращаться некоторое время (обычно до 20 минут). При активации автоочистки (самоочистки) на дисплее пульта обычно загорается значок похожий на вентилятор. Поэтому очень легко перепутать эту опцию со стандартной регулировкой скорости вентилятора.Значок активирующий автоочистку испарителя
  3. Чтобы активировать ионизатор или плазменный генератор для некоторых кондиционеров предусмотрена кнопка «Plasma» (может быть «Ion» или что-то подобное). Благодаря этой функции включается в работу дополнительный фильтр, осуществляющий в общем смысле две функции:
  • очищает воздух от пыли и микробов;
  • обогащает воздух отрицательными ионами.Значки ионизатора

Осуществляется это благодаря электростатическому полю, создаваемым дополнительным устройством во внутреннем блоке кондиционера. Опция полезная, если она есть на вашей модели, то обязательно пользуйтесь.

  1. Чтобы настроить поддержание температуры по датчику в пульте, а не по датчику во внутреннем блоке, на некоторых моделях предусмотрена кнопка «I-Feel». Данная опция призвана более точно поддерживать температуру в зоне отдыха человека. Но, по моему мнению, вполне можно настроить комфортную температуру и с традиционным датчиком.Значки для регулировки температуры по датчику в пульте дистанционного управления
  2. Чтобы посмотреть текущую температуру в комнате на некоторых пультах предусмотрена кнопка «Temp». При ее нажатии на дисплее пульта или на дисплее внутреннего блока отображается текущая температура в помещении. Через несколько секунд после нажатия на данную кнопку, снова показывается настроенная температура. На некоторых кондиционерах текущая температура может показываться постоянно на внутреннем блоке устройства (отображается автоматически после настройки температуры).Значок просмотра текущей температуры в помещении

«Скрытые» кнопки на пультах сплит-систем

На некоторых пультах есть «углубленные» кнопки, которые нажимаются тонким предметом. Это обычно кнопки «Reset» – сбрасывает настройки пульта к заводским (обычно к автоматическим). И кнопка «Lock», которая блокирует пульт от случайного нажатия (или, например, от детей). Чтобы разблокировать нужно нажать её повторно.Знаки блокировки и сброса настроек пульта

Последовательность настройки любого кондиционера

  1. Сначала включаем кондиционер в «сеть»;
  2. Включаем прибор кнопкой «On/off»;
  3. Выбираем нужный режим кнопкой «Mode». Ждем 10 минут, и параллельно продолжаем настройку по следующим пунктам;
  4. Настраиваем нужную температуру кнопками «Temp» или стрелками;
  5. Если требуется, то настраиваем нужную скорость вращения вентилятора;
  6. Если требуется, то настраиваем направление потока воздуха регулировками жалюзи «Swing»;
  7. Если требуется, то активируем дополнительные опции – ионизатор, самоочистка, «i-feel», «sleep», «turbo» и прочие.

P.S. Если в комнате текущая температура соответсвует настроенной, то кондиционер не будет холодить (или греть в зависимости от режима).

Значки и кнопки на внутреннем блоке сплит-системы

Скрытая кнопка по крышкой внутреннего блокаПрактически на всех внутренних блоках есть одна «волшебная кнопка», с помощью которой можно включить кондиционер с автоматической настройкой. Обычно она малозаметна – находится под передней крышкой блока на корпусе или на дисплее. Обозначается «auto» или «on/off». Настроить необходимые параметры при помощи этой кнопки нельзя – потребуется пульт, хотя бы универсальный (если утерян штатный). Подробнее об этой скрытой кнопке читайте по ссылке ниже (на статью про включение кондиционера без пульта).

Инструкции по настройке кондиционера в различных режимах

Если вам нужно включить кондиционер в определенном режиме, то на моем сайте уже есть все инструкции:

  • включение кондиционера на охлаждение;
  • настройка на обогрев;
  • включение автоматического режима;
  • настройка режима осушки;
  • включение режима вентиляции;
  • настройка кондиционера без пульта;
  • управление сплит-системой при помощи телефона.

Рассмотренные в данной статьи кнопки и функции наиболее часто встречаются на пультах, но и попадаются «навороченные» пульты, где тоже есть все те же опции, только обозначены необычно. Примеры: круглые пульты на LG Stylist, так же на пультах Electrolux непонятные обозначения и прочие.

На этом, пожалуй всё… Если статья была для вас полезна, то оставляйте комментарии!

На чтение 6 мин Просмотров 2к. Опубликовано 16.10.2017 Обновлено 15.05.2018

Торговая марка Acson принадлежит малазийской компании «O.Y.L. Manufacturing Company». Товары бренда появились на российском рынке сравнительно недавно, но уже успели зарекомендовать себя как качественная, современная, надежная продукция. Кондиционеры данной марки можно купить на территории 50 мировых стран.

Наиболее приоритетная задача производителя – реализация программы, основанной на постоянном совершенствовании качества готовой продукции при максимальном снижении конечной цены. Такая политика компании никоим образом не отражается на качестве изделий и закупаемых комплектующих. Уже долгое время Аксон сотрудничает исключительно с проверенными поставщиками, зарекомендовавшими себя на мировом рынке бытовой и производственной техники: Copeland, Matsushita, Bristol.

Содержание

  1. Основные линейки кондиционеров
  2. Кассетные системы кондиционирования
  3. Наполно-потолочные модели кондиционеров
  4. Канальные мультисплит
  5. Бытовые системы кондиционирования
  6. Сравнение характеристик популярных моделей
  7. Инструкции к пульту управления и кондиционерам Acson
  8. Коды ошибок кондиционеров Acson
  9. Отзывы пользователей

Основные линейки кондиционеров

Производитель, безусловно, заинтересован в привлечении как можно большего количества новых клиентов, поэтому постоянно расширяет и дополняет линейки выпускаемых сплит-систем. Благодаря продуманной рыночной стратегии бренд Эксон укрепил позиции не только в Малайзии, но в Европе, России, странах бывшего СНГ. Климатическая техника марки встречается в 80 странах, благодаря расширенной сети дистрибьюторов.

Сплит-системы Acson выпускаются в нескольких вариантах в зависимости от предназначения:

  1. Мини-чиллеры.
  2. Фанкойл.
  3. Канальные мультисплит средней и увеличенной мощности.
  4. Широкий модельный ряд кондиционеров Аксон бытового назначения.

Климатическое оборудование разрабатывается и производится на объектах компании «O.Y.L. Manufacturing Company Sdn. Bhd.» (O.Y.L.). В производственные ресурсы предприятия входят несколько современных заводов, работающих на базе последних технологий и научных инноваций. Марка располагает более 10 психометрических испытательных лабораторий и собственным исследовательско-конструкторским центром (R&D Center), являющимся крупнейшим в Юго-Восточной Азии.

Кассетные системы кондиционирования

Установка кондиционера кассетного типа осуществляется в подвесные потолки. После предварительной разметки конструкции фиксируются подвесными стержнями и анкерными гайками. При выборе подобной модели не менее важно правильно установить дренажную систему и отрегулировать трубный зажим. В комплект кассетного кондиционера входят:

  • одна из реверсивных моделей внутреннего блока;
  • наружный блок;
  • проводной (беспроводной) пульт к кондиционеру Acson.

В зависимости от мощности отдельно взятой модели, такие «кассетники» справятся с помещением площадью до 50 м2. Последние модели кассетных установок оснащены одновременно ионизирующим, антибактериальным и дезодорирующим фильтрами. Подключенные кондиционеры возможно объединить в одну сеть с дистанционным пультовым управлением.

Наполно-потолочные модели кондиционеров

Отличие линейки напольно-потолочного оборудования в том, что установка внутреннего блока допустима как на стеновой поверхности (под потолком), так и на полу. Как и большинство моделей, система отлично справляется с охлаждением и обогревом, позволяя в минимальные сроки добиться оптимальных показателей микроклимата. Модели напольно-подпотолочных конструкций выпущены в двух сериях: «C» и «D». Основными характеристиками подобных кондиционеров являются:

  • создание комфортных условий на площади до 160 м2;
  • потребление мощности в 3 кВт и выше рассчитано на однофазную и трехфазную сеть;
  • оповещение о действующем режиме и возникшей неисправности посредством светодиодного блока;
  • имеется «турбо»-режим, позволяющий создать желаемый микроклимат всего за 20 минут.

Сплит-системы относятся к оборудованию промышленного и полупромышленного назначения. Климатические устройствам из этой категории значительно превосходят своих собратьев по стоимости, но и гораздо мощнее их. Таким образом, установка способна эффективно функционировать в пределах помещений, общей площадью 80-160 м2.

Канальные мультисплит

Выпускаются в сериях «ACC» и «ALS». Имеют встроенное микропроцессорное управление. Отличаются следующим:

  • наличие четырех мощностей работы;
  • обслуживание объектов площадью от 28 м2 до 67 м2;
  • вентиляторный двигатель работает на четырех скоростях.

Устройства призваны создать не только комфортные температурные условия, но и оптимальный уровень влажности. Канальные приборы в количестве до 4-х внутренних блоков допустимо подключать к одному внешнему. При этом каждый из подключенных приборов может быть оснащен встроенным ионизатором воздуха и плазменным фильтром.

Бытовые системы кондиционирования

Компания учитывает пожелания своих клиентов и старается расширить линейку выпускаемых бытовых кондиционеров. В данный момент в линейке настенных мультисплит есть модели:

  • инверторного типа;
  • кондиционеры серии «On/Off»;
  • отдельная линейка приборов, работающая только на охлаждение.

Инверторные мультисплит рассчитаны на варианты рабочего режима на охлаждение и обогрев. Кроме этого, «inverter»-системы оснащены режимом вентиляции, поддержанием достигнутой температуры в режиме «auto». Кондиционеры с обозначением «inverter» эффектны в помещениях до 30-35 м2 и способны безопасно функционировать при внешней температуре в -15°С.

Серия сплит-систем серии «On/Off» призваны работать как в режимах охлаждение/обогрев, так и только на охлаждение. Отличаются следующими характеристиками:

  • наличие таймера включения/отключения;
  • опция дезодорирующего фильтра;
  • возможность регулирования скорости работы вентилятора;
  • функция запоминания выполненных настроек.

Настенные мультисплит в зависимости от модели способны обслуживать от 20 до 65 м2, при этом не только меняя температуру, но и придавая воздуху кристальную свежесть. Большинство последних линеек кондиционеров (как и инверторных, так и «on/off») оснащены высокоэффективной трехступенчатой системой фильтрации и плазменным стерилизатором. Такая обработка поступающих воздушных масс полностью избавляет их от вредных примесей, бактерий и опасных для человека вирусов.

Сравнение характеристик популярных моделей

Техническая характеристика Наименование модели
A5WMY10LR A5WM15G2R RCM50DR
Воздушный поток, м3/мин 9,78 9,78 22,3
Мощность охлаждения, Вт 2550 3520 14068
Мощность обогрева, Вт 2840 3520 14068
Потребление при охлаждении, Вт 730 1230 5115
Потребление при обогреве, Вт 700 1080 4517
Уровень шума (max), дБ 40 42 58
Обслуживаемая площадь (max), м2 25-30 50 140

Инструкции к пульту управления и кондиционерам Acson

Ко всем кондиционерам марки Acson прилагается инструкция. Данное руководство предоставляет покупателю такие сведения, как:

  • рекомендации по монтажу и подключению приборов;
  • основные правила по эксплуатации;
  • техническое обслуживание системы и устранение возникших неполадок.

Помимо схематичного изображения сплит-систем с обозначением элементов, в буклет входит и подробная инструкция к пульту. В данном разделе инструкции полностью разъясняется значение каждой кнопки дистанционного устройства и значков, отображаемых на дисплее.

Коды ошибок кондиционеров Acson

Все модели Аксон оснащены высокоэффективной системой самодиагностики. Такая дополнительная функция не только контролирует работу прибора, но и защищает его. По завершении самодиагностики неисправностей на дисплее устройства высвечиваются коды ошибок. Каждый код ошибки указывает на конкретную причину сбоя.

Отзывы пользователей

При использовании оборудования Acson покупателя отмечают такие «плюсы», как:

  • абсолютная бесшумность устройств;
  • простота управления и настройки режимов;
  • минимальное техническое обслуживание;
  • высокая производительность.

Согласно отзывам, широкий модельный ряд товаров позволяет подобрать оптимально подходящую модель в зависимости от строения и площади обслуживаемого объекта.

  • Страница 1 из 35

    СПЛИТ-СИСТЕМЫ НАСТЕННОГО ТИПА ACSON. РУКОВОДСТВО ПО МОНТАЖУ, ЭКСПЛУАТАЦИИ И ОБСЛУЖИВАНИЮ. Опубликовано TopClimat

  • Страница 2 из 35

    СПЛИТ-КОНДИЦИОНЕРЫ НАСТЕННОГО ТИПА ВНУТРЕННИЕ БЛОКИ ТОЛЬКО ОХЛАЖДЕНИЕ AWM 07F AWM 10F РЕВЕРСИВНЫЕ МОДЕЛИ AWM 07FR AWM 10FR НАРУЖНЫЕ БЛОКИ ALC 07B ALC 10B ALC 07BR ALC 10BR РУКОВОДСТВО ПО МОНТАЖУ, ЭКСПЛУАТАЦИИ И ОБСЛУЖИВАНИЮ Äàòà èçä. — ôåâðàëü 2002 ã. 1 Опубликовано TopClimat

  • Страница 3 из 35

    В данном р оводстве приведены основные требования и ре омендации по монтаж и э спл атации сплит-системы, соблюдение оторых необходимо для обеспечения безопасной и орре тной работы обор дования. Для соответствия национальным правилам и стандартам мо т потребоваться специальные настрой и и ре

  • Страница 4 из 35

    WARNING! ВАЖНО! Провода сетево о абеля данно о ондиционера имеют след ющ ю цветов ю мар иров : Желто-зеленый .. Провод заземления Синий ……………. Н левой провод Коричневый ……. Силовой провод Та а цвет проводов сетево о абеля может не соответствовать цветовой мар иров е, идентифицир ющей

  • Страница 5 из 35

    КОМПЛЕКТУЮЩИЕ И АКСЕССУАРЫ ВНУТРЕННИЙ БЛОК № Наименование МОНТАЖНОЕ ОСНОВАНИЕ Кол. 5 Для подсоединения абеля 2. Винты М8 х 5/8” 2 Для монтажа держателя п льта 3. Элементы питания (ААА) 2 Для п льта правления 4. П льт правления с держателем 2 Для правления бло ом ДРЕНАЖНАЯ ЗАГЛУШКА ВИНИЛОВАЯ ЛЕНТА

  • Страница 6 из 35

    НАРУЖНЫЙ БЛОК ALC 07/10/15 B/BR 270.0 5 15 39 348 318 68.5 15 39 740 129 482 129 5 270 152 55 65 ПРИМЕЧАНИЕ: все размеры 20 20 20 92 165.5 494 232.5 474 141.0 47 2.5 266 азаны в мм CAUTION! При монтаже и обсл живании след ет соблюдать осторожность, чтобы не задеть острые рая и поверхности

  • Страница 7 из 35

    ƒ Место, выбранное для монтажной позиции, должно быть хорошо проветриваемым, чтобы возд х, подаваемый на охлаждение онденсатора, постоянно обновлялся. ƒ Констр ция, на оторой станавливается бло , должна обладать достаточной нес щей способностью, чтобы выдержать е о вес, а та же иметь зв о-и вибропо

  • Страница 8 из 35

    На рис н е азаны величины ре оменд емых сбободных зазоров от стено бло а. Мин. 50 мм Выше ровня лаз Мин. 50 мм Мин. 50 мм РЕКОМЕНДУЕМЫЕ СВОБОДНЫЕ ЗАЗОРЫ ДЛЯ ПРОВЕДЕНИЯТЕХНИЧЕСКОГО ОБСЛУЖИВАНИЯ И РЕМОНТА НАПРАВЛЕНИЕ ВОЗДУШНОГО ПОТОКА УСТАНОВКА МОНТАЖНОГО ОСНОВАНИЯ CAUTION! ƒ Перед началом монтажа

  • Страница 9 из 35

    ПОДГОТОВКА ВНУТРЕННЕГО БЛОКА К МОНТАЖУ ФИКСАЦИЯ БЛОКА НА МОНТАЖНОМ ОСНОВАНИИ Выньте бло из па ов и, поместите на ровн ю поверхность и снимите фи сир ющие винты, оторыми репится лицевая панель. Повесьте бло на монтажное основание в верхней е о части. ВЫБОР НАПРАВЛЕНИЯ ТРУБНЫХ ЛИНИЙ Линии хлада ента

  • Страница 10 из 35

    МОНТАЖ ТРУБОПРОВОДА ХЛАДАГЕНТА ДЛИНА ТРУБНОЙ ЛИНИИ И ВЫСОТА ПОДЪЕМА ВНУТРЕННИЙ БЛОК Слиш ом длинный тр бопровод хлада ента приводит снижению надежности и производительности ондиционера. При наличии в тр бопроводе большо о оличества из ибов величивается сопротивление пото хлада ента, а,

  • Страница 11 из 35

    ПОДСОЕДИНЕНИЕ ТРУБНЫХ ЛИНИЙ К БЛОКАМ ƒ Отцентр йте подсоединяем ю тр б и соответств ющий патр бо бло а, а затем затяните р ой оничес ю ай на тр бе. ТРУБНЫЙ СОЕДИНИТЕЛЬ РАЗВАЛЬЦОВАННАЯ ТРУБА ƒ После это о, для о ончательно о репления ай и, затя ивайте ее ай овертом до тех пор, по а не слышите хара

  • Страница 12 из 35

    РЕВЕРСИВНЫЕ МОДЕЛИ Конта тная олод а нар жно о бло а Конта тная олод а вн тренне о бло а Провод (6м) от датчи а температ ры теплобменни а онденсатора 4 WV Реле 4 WV OF OF COMP COMP N МОДЕЛЬ 07ЕR Параметры эле тропитания 230В /1Ф/ 50 Гц + Потребляемая мощность (охлаждение + вентиляция) Вт

  • Страница 13 из 35

    •При от рытии вентиля произойдет подача азообразно о хлада ента во вн тренний бло , в рез льтате, ондиционер б дет отов для зап с а. •В лючите ондиционер на 10 — 15 мин т, а затем снимите по азания манометра на стороне низ о о давления. При нормальной работе станов и величина давления должны быть в

  • Страница 14 из 35

    НЕОБХОДИМЫЕ ОБЩИЕ ПРОВЕРКИ ПЕРЕД ЗАПУСКОМ КОНДИЦИОНЕРА РЕКОМЕНДУЕТСЯ: •Убедиться в возможности свободно о вращательно о движения рыльчат и вентилятора и жалюзийных заслоно вн тренне о бло а, поворачивая их р ой. •Убедиться в наличии хороше о возд хообмена в месте расположения нар жно о бло а.

  • Страница 15 из 35

    ИДЕНТИФИЦИРУЮЩАЯ ТАБЛИЦА СВЕТОВЫХ ИНДИКАТОРОВ “ХОЛОДНЫХ” МОДЕЛЕЙ 07F/10F (инди ация нормальных рабочих словий, сбоев и неисправностей) Обозначения : Ïîñòîÿííîå âûñâå÷èâàíèå ñâåòîèíäèêàòîðà POWER Ýëåêòðîïèòàíèå SLEEP Íî÷íîé ðåæèì TIMER Ðàáîòà ïî òàéìåðó DRY Ñâåòîèí èêàòîð ìîæåò áûòü âêëþ÷åí èëè

  • Страница 16 из 35

    ИДЕНТИФИЦИРУЮЩАЯ ТАБЛИЦА СВЕТОВЫХ ИНДИКАТОРОВ РЕВЕРСИВНЫХ МОДЕЛЕЙ 07FR/10FR (инди ация нормальных рабочих словий, сбоев и неисправностей) COOL DRY FAN HEAT Режим Вентиляция Режим на рева охлаждения ос шения Режим SLEEP FILTER CHECK Ночной Засорение режим фильтра Нормальные рабочие словия/ сбои и

  • Страница 17 из 35

    ПОЛЬЗОВАНИЕ ПУЛЬТОМ УПРАВЛЕНИЯ ФУНКЦИОНАЛЬНЫЕ ВОЗМОЖНОСТИ ПУЛЬТА УПРАВЛЕНИЯ 1. ON/OFF — В лючение/Вы лючение бло а •Кондиционер в лючается и вы лючается одно ратным нажатием ноп и. 6 2. MODE — ноп а выбора рабоче о режима •Рабочий режим выбирается последовательным нажатием ноп и MODE •Рабочие

  • Страница 18 из 35

    НАСТЕННЫЙ МОНТАЖ ПУЛЬТА УПРАВЛЕНИЯ •С помощью винтов за репите держатель п льта на стене. Убедитесь в том, что при расположении п льта в выбранной позиции б дет выполняться нормальная передача и прием правляющих си налов. •Для фи 1 2 сации п льта в держателе выполните след ющее: Вставьте п льт в

  • Страница 19 из 35

    Для правильной станов и режима охлаждения (COOL): •Нажатием ноп и MODE выберите режим охлаждения. •Установите треб емые температ р ( став ) и с орость вентилятора. Для правильной станов и режима ос шения (DRY): CAUTION! •Нажатием ноп и MODE выберите режим ос шения. •Установите треб ем ю температ р

  • Страница 20 из 35

    ВКЛЮЧЕНИЕ И ОТКЛЮЧЕНИЕ КОНДИЦИОНЕРА ПО ПРОГРАММЕ ТАЙМЕРА •Для а тивизации таймера необходимо нажать ноп TIMER. На дисплей при этом выводятся цифры, обозначающие период времени (в часах), по истечении оторо о ондиционер должен автоматичес и в лючиться или вы лючиться, в зависимости от те ще о стат

  • Страница 21 из 35

    ЗАЩИТА ТЕПЛОБМЕННИКА ОТ ОБМЕРЗАНИЯ При за рязнении возд шно о фильтра температ ра испарения хлада ента понижается, что, в рез льтате, вызывает обмерзание теплообменни а испарителя. В этом сл чае начинает высвечиваться соответств ющий светоинди атор, а а толь о температ ра испарения дости ает -20С,

  • Страница 22 из 35

    РЕКОМЕНДАЦИИ ПО ЭКСПЛУАТАЦИИ • Польз ясь ондиционером, не переохлаждайте помещение, та а это нецелесообразно с точ и зрения энер озатрат, а та же вредно для здоровья. • Избе айте наличия в помещении источни ов дополнительных тепловыделений. • Не доп с айте попадания на ондиционер прямых солнечных л

  • Страница 23 из 35

    ОПЦИОНАЛЬНЫЙ ФИЛЬТР фильтр выполняет двойн ю ф н цию: 1) тон ая очист а возд ха 2) дезодорация возд ха 1 СТУПЕНЬ 2 СТУПЕНЬ ЭЛЕКТРОСТАТИЧЕСКИЙ ФИЛЬТР ТОНКОЙ ОЧИСТКИ ДЕЗОДОРИРУЮЩИЙ ФИЛЬТР Эле тростатичес ий полипропиленовый фильтр с предварительной заряд ой предназначен для очист и возд ха от ми рос

  • Страница 24 из 35

    ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ WARNING! Перед проведением любых работ по техничес ом обсл живанию и ремонт обязательно от лючите ондиционер от источни а питания! Кондиционер предназначен для продолжительной работы и треб ет лишь минимально о техничес о о обсл живания с проведением в основном необходимых

  • Страница 25 из 35

    ТЕХНИЧЕСКОЕ ОБСЛУЖИВАНИЕ НАРУЖНОГО БЛОКА Нар жные бло и серии ALC с онстр ированы та им образом, что их техничес ое обсл живание не представляет сложностей. При снятии верхней, бо овой, лицевой и тыльной панели все вн тренние омпоненты бло а становятся ле о дост пными. При нормальных словиях э спл

  • Страница 26 из 35

    ВЫЯВЛЕНИЕ НЕИСПРАВНОСТЕЙ (для пользователя) При возни новении а ой-либо неисправности или сбоя в работе ондиционера след ет немедленно от лючить е о от источни а питания. Ниже приведена таблица пользователя для выявления наиболее возможных неисправностей. ПРИЧИНЫ НЕИСПРАВНОСТЬ 1. По истечении более

  • Страница 27 из 35

    ВЫЯВЛЕНИЕ НЕИСПРАВНОСТЕЙ (для сервисной сл жбы) ДИАГНОСТИКА ПО ПОКАЗАНИЯМ МАНОМЕТРА ВОЗМОЖНАЯ ПРИЧИНА ВЫСОКОГО ДАВЛЕНИЯ НИЗКОГО ДАВЛЕНИЯ ВЫСОКОГО ДАВЛЕНИЯ НИЗКОГО ДАВЛЕНИЯ ВЫСОКОГО ДАВЛЕНИЯ НИЗКОГО ДАВЛЕНИЯ ОЧЕНЬ ВЫСОКОЕ ПОВЫШЕННОЕ НОРМАЛЬНОЕ ПОНИЖЕННОЕ ЛИНИЯ КОНТУРА ХЛАДАГЕНТА ОЧЕНЬ НИЗКОЕ

  • Страница 28 из 35

    ДИАГНОСТИКА ПО БЛОК-СХЕМАМ 1) Диа ности а эле тричес ой цепи Нет охлаждения/ на рева Бло не зап с ается Проверьте параметры эле тросети: — напряжение, — фазы, — частот Проверьте став и п льта правления Проверьте сетевой провод Проверьте разъединитель цепи и предохранитель Вентилятор не зап с ается

  • Страница 29 из 35

    2) Диа ности а онт ра хлада ента/ провер а правильности э спл атации Недостаточное охлаждение Зап с есть Высо ая на р з а Проверьте цир ляцию возд ха Конт р хлада ента За рязнение теплообменни ов нар жно о/вн тренне о бло ов Утеч и За поривание апиллярной тр б и, фильтра-ос шителя и т.д. За

  • Страница 30 из 35

    ПЕРЕЧЕНЬ ЗАПАСНЫХ ЧАСТЕЙ ВНУТРЕННЕГО БЛОКА (AWM 07F/07FR/10F/10FR) 11 1 5 4 6 10 9 3 12 2 8 7 1. КОРПУСНАЯ КОРОБКА В КОМПЛЕКТЕ 7. ВОЗДУХОРАСПРЕДЕЛИТЕЛЬНЫЕ ЖАЛЮЗИ В КОМПЛЕКТЕ 2. ЭЛЕКТРОДВИГАТЕЛЬ ВЕНТИЛЯТОРА 8. БЛОК УПРАВЛЕНИЯ В КОМПЛЕКТЕ 3. ВЕНТИЛЯТОР ПЕРЕКРЕСТНОГО ПОТОКА 9. ДЕРЖАТЕЛЬ ТЕРМИСТОРА 4.

  • Страница 31 из 35

    ПЕРЕЧЕНЬ ЗАПАСНЫХ ЧАСТЕЙ НАРУЖНОГО БЛОКА (ALC 07B/ 07BR/10B/10BR) 8 7 6 5 9 4 10 3 1 2 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 1. ТЫЛЬНАЯ ПАНЕЛЬ 14. ПЛОСКАЯ ШАЙБА 2. ВЕРХНЯЯ ПАНЕЛЬ 15. ГАЙКА КОМПРЕССОРА (РЕЗЬБА М8) 3. ТЕПЛООБМЕННИК КОНДЕНСАТОРА 16. ОСНОВАНИЕ БЛОКА В КОМПЛЕКТЕ 4. МОНТАЖНОЕ

  • Страница 32 из 35

    ЭЛЕКТРОСХЕМЫ INDOOR UNIT MODEL : AWM 07F / 10F OUTDOOR UNIT MODEL : ALC 07B / 10B 31 Опубликовано TopClimat

  • Страница 33 из 35

    ЭЛЕКТРОСХЕМЫ INDOOR UNIT MODEL : AWM 07FR / 10FR FIELD SUPPLY WIRING OUTDOOR UNIT MODEL : ALC 07BR / 10BR 32 Опубликовано TopClimat

  • Страница 34 из 35

    ÌÎÄÅËÜ ÂÍÓÒÐÅÍÍÈÉ ÁËÎÊ ÍÀÐÓÆÍÛÉ ÁËÎÊ ÍÎÌÈÍÀËÜÍÀß ÕËÀÄÎÏÐÎÈÇÂÎÄÈÒÅËÜÍÎÑÒÜ ÍÎÌÈÍÀËÜÍÀß ÒÅÏËÎÏÐÎÈÇÂÎÄÈÒÅËÜÍÎÑÒÜ ÂÅÍÒÈËßÒÎÐ ÎÁÙÀß ÏÎÒÐÅÁËßÅÌÀß ÌÎÙÍÎÑÒÜ ÎÕËÀÆÄÅÍÈÅ ÍÀÃÐÅ ÐÀÁÎ×ÈÉÒÎÊ ÎÕËÀÆÄÅÍÈÅ ÍÀÃÐÅ ÏÀÐÀÌÅÒÐÛ ÝËÅÊÒÐÎÏÈÒÀÍÈß ÕËÀÄÀÃÅÍÒ ÒÈÏ ÂÅÍÒÈËßÒÎÐÀ ÐÀÑÕÎÄ ÂÎÇÄÓÕÀ ÝËÅÊÒÐÎÄÂÈÃÀÒÅËÜ ÂÅÍÒÈËßÒÎÐÀ ÒÐÓÁÛ

  • Страница 35 из 35
  • РУКОВОДСТВО ПО ИСПОЛЬЗОВАНИЮ

    1. Источник сигналов

    • Источник, откуда сигнал будет передаваться.

    2. Индикация передачи сигнала

    • Мигает для подтверждения того, что последняя установка была

    передана на модуль.

    3. Кнопка «ВКЛ/ВЫКЛ» (ON/OFF)

    • Нажмите один раз для включения кондиционера.

    • Вновь нажмите для остановки модуля.

    4. Установка температуры

    • Для установки желаемой температуры в комнате, нажмите ▲или ▼

    для повышения или понижения установленной температуры.

    • Диапазон установленной температуры варьируется от 16°С до 30°С

    (При наличии от 20°С до 30°С).

    • Одновременно нажмите обе кнопки для переключения ▲ и ▼ от

    установки °С к °F.

    5. Режим работы

    • Нажмите кнопку MODE (РЕЖИМ) для выбора типа режима работы.

    • Только для охлаждения, возможные режимы: COOL ( ) (ХОЛОД), DRY

    ( ) (ОСУШЕНИЕ) и FAN ( ) (BЕНТИЛЯЦИЯ).

    • Для обогревательного насоса возможные режимы: AUTO ( ) (АВТО),

    COOL ( ) (ХОЛОД), DRY ( ) (ОСУШЕНИЕ), FAN ( ) (ВЕНТИЛЯЦИЯ)

    и HEAT ( ) (ОБОГРЕВ).

    6. Выбор скорости вентилятора

    • Нажмите кнопку

    вентилятора в следующем порядке:

    • Прекратите нажимание, как только на дисплее экрана появится

    желаемая скорость вентилятора.

    7.

    Функция турбо

    • Нажмите

    • Температура повышается в комнате при режиме HEAT (ОБОГРЕВ),

    понижается при режиме COOL (ХОЛОД) или DRY (ОСУШЕНИЕ).

    Скорость вентилятора повысится, если он не установлен на

    максимальную скорость.

    • Температура и скорость вентилятора вернутся на установленное

    функционирование при повторном нажатии

    • Возможны только при режимах HEAT (ОБОГРЕВ), COOL (ХОЛОД) и

    DRY (ОСУШЕНИЕ).

    8. Установка включения таймера

    • Нажмите кнопку SET для запуска функции включения таймера.

    • Установите желаемое время включения беспрерывным нажатием

    кнопки SET. Если таймер установлен на 7:30 утра, то кондиционер

    включится ровно в 7:30 утра.

    OM-G12-0104-Acson

    для непрерывного переключения скорости

    Низк –––: Сред –––: Высок –––: Авто

    для быстрого охлаждения или операции обогрева.

    11

    11

    или после 20 минут.

    11/21/05, 10:51 AM

    Понравилась статья? Поделить с друзьями:
  • Кондиционер whirlpool gz 10b e1 инструкция
  • Кондиционер whirlpool dg11j1 39 инструкция
  • Кондиционер whirlpool amc 987 инструкция
  • Кондиционер whirlpool 6 sense инструкция пульт управления
  • Кондиционер wellton wap 212 инструкция