Mindeo ms3690 1d bt инструкция на русском

Mindeo MS3690 User Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

MS3690 Lightweight Data Terminal

User Manual

Version: MS3690_UM_EN_V1.0.2

loading

Related Manuals for Mindeo MS3690

Summary of Contents for Mindeo MS3690

  • Page 1
    MS3690 Lightweight Data Terminal User Manual Version: MS3690_UM_EN_V1.0.2…
  • Page 3
    Notice MS3690 is a lightweight programmable data terminal. A SDK based on C is provided including user-friendly IDE and fully functional APIs. Before operating the terminal, please make sure you carefully read the following information to ensure that your terminal is able to perform at the level for which it is designed.
  • Page 4: Table Of Contents

    Contents Notice …………………………… ii Contents …………………………iii 1 Specifications ……………………….1 1-1 Technical specifications …………………… 1 1-2 Default settings for each barcode ………………..4 1-3 Dimensions ……………………… 6 1-4 Parts of the terminal ……………………7 1-5 Keys Introduce ……………………..8 1-6 Parts of the cradle …………………….

  • Page 5
    6 User customized application software for MS3690 …………….. 31 6-1 Auto Run ……………………….. 31 6-2 Execute ……………………….31 6-3 Download ………………………. 31 7 Barcode programming instructions ………………..32 7-1 Example: Single-parameter setting by scanning 1D barcodes ……….32 7-2 Decode illumination and decode aiming pattern ……………. 33 7-3 DPM, Multiple symbols, Structured append, etc.
  • Page 6: Specifications

    1 Specifications 1-1 Technical specifications Table 1-1 Technical specifications MS3690-1D MS3690-2D Bluetooth: 30m(line of sight) Working range Wi-Fi: 100m(line of sight) Bluetooth: 2.4–2.5GHz, Bluetooth 4.0/3.0/2.1+EDR, Class 2 Radio link Wi-Fi:2.4GHz, compliant with Wi-Fi IEEE 802.11 b/g/n protocol standards Bluetooth: HID keyboard, SPP, BLE…

  • Page 7
    Standby time 14 days 7 days Bluetooth: 22 hours Bluetooth: 19 hours Working time Wi-Fi: 13 hours Wi-Fi: 12 hours (based on 1 scan/5 seconds) (based on 1 scan/5 seconds) Light source 650nm visible laser diode white light Image size 1280×800 pixels Scanning angle Horizontal:42°,vertical:26.5°…
  • Page 8
    Humidity 5% to 95%(non-condensing) Laser safety: EN60825-1,Class 1 EMC:EN55022,EN55024 Electrical safety: EN60950-1 Safety Illumination: 0~100,000LUX Protection class: IP65 Drop resistance: Multiple 1.2m(4.9ft)drops to concrete Environmental: RoHS compliant *Bluetooth and Wi-Fi are optional (Alternative).
  • Page 9: Default Settings For Each Barcode

    1-2 Default settings for each barcode Table 1-2 Default settings Check Read Check digit digit Min.code Proprietary Code type code enable verification transmis length code ID sion √ √ √ (12) UPC-A √ √ √ (8) UPC-E √ √ (8) UPC-E1 √…

  • Page 10
    Note: The settings for ISBN/ISSN and EAN-13 must be the same. Fixed-length barcodes. The settings for GS1 DataBar Truncated and GS1 DataBar must be the same.
  • Page 11: Dimensions

    1-3 Dimensions Figure 1-1 Dimensions of the terminal Figure 1-2 Dimensions of the cradle Note: There are two types of cradle, one is a Bluetooth cradle, which can communicate with the terminal for Bluetooth; the other is a charging cradle, which only supports the charging function.

  • Page 12: Parts Of The Terminal

    1-4 Parts of the terminal Figure 1-3 Parts of the terminal ○ 1 Blue LED (Bluetooth power); Green LED (Decode success); Red LED (Charging indicator) ○ 2 OLED ○ 3 Left soft key ○ 4 Right soft key ○ 5 Up navigation key ○…

  • Page 13: Keys Introduce

    1-5 Keys Introduce Operations, such as scrolling and selecting menus, moving a cursor, or scanning a barcode, are controlled by trigger keys and stroke keys. Table 1-3 Key functions Key/Action/Feature Part Position Description ○ Left soft key Functionalities are identified by the screen display. In general, the acknowledge/non-acknowledge of ○…

  • Page 14: Parts Of The Cradle

    1-6 Parts of the cradle Figure 1-4 Parts of the cradle ○ 19 Charging (Green) ○ 20 USB interface ○ 21 Firmware upgrade key…

  • Page 15: Introduction To Installation

    2 Introduction to installation 2-1 Installing a USB HID keyboard wired terminal Note: The default interface of the terminal is Bluetooth/Wi-Fi. Please change the interface to USB HID Keyboard (See 5-2 Data Transfer). Refer to Figure 2-1, plug one end of the USB cable to the terminal. Plug the other end into the USB port of the computer.

  • Page 16
    Figure 2-2 Diagram of replacing the Lithium-ion battery…
  • Page 17: Getting Started

    3 Getting started 3-1 Power on/off terminal Power on terminal: Press the Power/Sleep key for two seconds. Power off terminal: Press the Power/Sleep key for two seconds. 3-2 Charge terminal Please charge the terminal before the first time of use. There are three methods of charging battery as demonstrated in Figure 3-1.

  • Page 18
    Power off : Press the Wi-Fi Wi-Fi Power on Wi-Fi : Press the Wi-Fi…
  • Page 19: Introduction To Oled Display

    4 Introduction to OLED display OLED display icons Note1: The OLED screen is designed to display barcode scanning, Bluetooth/Wi-Fi network establishing, data transfer, system setting and other information. Note2: The display area is 64 dots (V) by 128 dots (H). The backlight will be switched off automatically if time of no operation exceeds a programmable duration (see 5-3 System setting Table 4-1 OLED display icons…

  • Page 20: Oled Display Menu

    The Home menu consists of five items, which are described in details in the following chapters. Table 4-2 depicts the hierarchy chart of the OLED display menu. Note: Items that are labeled ‘*’ are default selections. Table 4-2 OLED display menu Hierarchy chart Menu MS3690(BT) MS3690(Wi-Fi) 1. G ood-read of f S can M ode 2. M om ent ary* 3.

  • Page 21
    Hierarchy chart Menu MS3690(BT) MS3690(Wi-Fi) 1. D i sabl e 1. D i sabl e* O ut O f R ange A ut o R econnect i on 2. E nabl e* 2. E nabl e W i -F i * 1.
  • Page 22
    Hierarchy chart Menu MS3690(BT) MS3690(Wi-Fi) 1. USA* 2. Turkish F 3..S t at i on W i -F i A ccess P oi nt Bluetooth BLE Slave 1. U S A * U S B H I D K eyboard 2.
  • Page 23
    Hierarchy chart Menu MS3690(BT) MS3690(Wi-Fi) V i ew M em ory E rase V i ew M em ory E rase C onnect i on I nf o S yst em I nf orm at i on B l uet oot h I nf o…
  • Page 24: Operations Of The Terminal

    Continuous — The terminal always keeps scanning, and it does not matter when the Scan key is released or duration is elapsed. Note: MS3690-2D do not support “Continuous” mode. 5-1-2 Input Data Manually Using the virtual keypad, user can input a barcode manually, and then send the barcode to the host or store in the terminal.(The maximum length of barcode is 20.)

  • Page 25: Add Time/Date

    Step 1: Enable Quantity Enter, press the Scan Key to read a barcode. Example display: Step 2: Press Right Soft Key to the window below. Step 3: Use Navigation Keys to move the cursor, Scan/Select Key to select number(s), Right Soft Key to delete selected number(s).

  • Page 26: Sum Total

    Shenzhen” on the OLED screen. Note: The default database files are named SYS_DB.IDX and SYS_DB.DAT. In order to utilize the database functionality user should NOT change these file names and these two files are properly stored to the flash disk. 5-1-6-2 No Duplication When user scans the barcode, the terminal retrieves the database for a match in the meantime.

  • Page 27: Wi-Fi

    5-2-2 Wi-Fi The terminal can be configured to send data to a PC/Notebook/PAD/other instrument which equipped with an integrated Wi-Fi module or receive data from these instruments under the same WLAN.(See 5-3-2 Wi-Fi) Auto reconnection – By enable, when terminal’s Wi-Fi is power on, it will try to set up the WLAN and the connections with the host which it last connected.

  • Page 28: Data Batch

    to be deleted should be deselected and then deleted. 5-2-5-3 Format Note 1: The format function is a quick way to empty a whole U Disk. Note 2: Please format the U Disk once before the first time of use. Caution: 1.

  • Page 29
    5-3-1-2 Configure Bluetooth SPP profile communication Note : Make sure the Bluetooth module of the terminal is powered on (blue LED is on) and the selected profile is SPP. Step 1: Press Left Soft Key to the SPP List, if no connection record, press Left Soft Key to search. Wait for about 20 seconds and then the devices list will be shown Step 2: Use Navigation Key to move the cursor and press Scan/Select Key to connect.
  • Page 30: Wi-Fi

    Key to disconnect it. Cradle List DC0D3000091D DC0D3000091F √ Search Disconnect 5-3-2 Wi-Fi The terminal can be configured to send data to a PC, Notebook, PDA, and other instrument which equipped with an integrated Wi-Fi module or receive data from these instruments under the same WLAN. Two wireless operating modes have been provided: Station Mode and Access Point Mode.

  • Page 31
    Step 2: Press Left-Soft Key to search for device. Step 3: Wait for about 3 seconds, the terminal will list the serviceable WLAN around. “ ” indicates that the password-protected WLAN which needs the passphrase for accessing the wireless network. The screen shows as follow: Step 4: Press the Right-Soft Key to enter the DHCP setting menu, press the navigational key to select whether enable DHCP, and press the Scan/Select Key to confirm.
  • Page 32
    Notice: 1. Make sure the target host has been set up as a server and open the TCP/IP service, or it cannot set up the communication channel with host successfully. 2. If the target host address is a domain name, ensure the DNS setting of the terminal is open; If the target host address is an IP address, ensure that the DNS setting of the terminal is closed.
  • Page 33: Usb Hid Keyboard

    Set Wi-Fi Access Point Mode for data communication. The steps are as follows. Step 1: When enter the Access Point Setting Menu. The screen shows as follow: Press Up-Soft Key to get IP and port. Step 2: Press Set to change SSID, Passphrase, IP and Port. Step 3: Press SetUp to Set up a hot point.

  • Page 34: Default Setting

    5-3-11 Default Setting All parameters of the terminal return to default setting. Table 5-2 Default setting of terminal Items Option English* Language Chinese TR Chinese UTF-8* character encoding Big5 …… Volume Middle* High Disable* Keystone Enable Disable* Vibration Enable 30s* Backlight timeout Screen Luminance Middle*…

  • Page 35: Wi-Fi

    5-4-3 Wi-Fi Wi-Fi information includes the current wireless operating mode, connection information, IP, and socket information. The screen shows as follow. 5-4-4 Firmware Version User can view the firmware version of the terminal and scan engine.

  • Page 36: User Customized Application Software For Ms3690

    6 User customized application software for MS3690 With the support of MS3 SDK, The terminal supports user customized application software development. User customized application software is developed with the support of the terminal system API. For more detail about user customized application software development please refer to the MS3 SDK help files.

  • Page 37: Barcode Programming Instructions

    7 Barcode programming instructions 7-1 Example: Single-parameter setting by scanning 1D barcodes Important notes: 1. During the process of programming, LED is lighting to indicate the programming correctness. LED will go off if any incorrect programming operation performed. 2. After each successful programming, LED will go off and the terminal will beep twice. 3.

  • Page 38: Decode Illumination And Decode Aiming Pattern

    7-2 Decode illumination and decode aiming pattern Decode illumination mode: Enable illumination causes the terminal to turn on the illumination to aid decoding. Disable illumination to turn off illumination for the terminal during decoding. Better quality images could be obtained with illumination support. The effectiveness of the illumination decreases as the distance to the target increases.

  • Page 39: Dpm, Multiple Symbols, Structured Append, Etc. Read Setting

    7-3 DPM, Multiple symbols, Structured append, etc. read setting 2D symbols read: A global setting of 2D symbols readability. DPM format read: By setting Enable, the terminal can read 2D symbols in DPM (Direct Park Marking) format. Some barcodes in DPM format are shown below. Multiple symbols &…

  • Page 40
    Vertical centering read: By setting Enable, the terminal reads only the barcode centered by the aimer in vertical direction. However, the terminal will read either one of two barcodes which are positioned horizontally. See example below.
  • Page 41
    Multiple-scan setting Single-scan setting Alpha. Option barcode Option entry Follow respective 2D symbol setting All 2D OFF All 2D ON Only PDF417 ON 2D symbols read Only QR code ON Only Data Matrix ON Only MaxiCode ON Only Aztec Code ON Only Han Xin Code ON Disable DPM format read…
  • Page 42
    Note: The instruction of calibrating the aimer in vertical centering direction. Scan the barcode on this page. The terminal will give three musical short beeps to indicate entering calibration mode. Press the trigger of the terminal while maintaining the distance of about 15cm between the exit window of the terminal and this paper.
  • Page 43: Scanning Mode And Some Global Settings

    7-4 Scanning mode and some global settings Scanning mode: Good-read off -The trigger button must be pressed once to activate scanning. The light source of terminal stops scanning when there is a successful reading or no code is decoded after the Stand-by duration elapsed.

  • Page 44
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Good-read off Scanning mode Momentary Continue 01-99 Standby duration 01-99 (second) 00-FF Same barcode delay time 00-FF (50ms) 00-09 Double confirm 00-09 (00: no ) Global Max. code length 04-99 1D symbol 04-99 Global Min.
  • Page 45
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Data output delay in 00-FF continue-scan mode 00-99 (100ms) FF (Never) ASCII Character encoding system UTF-8 Windows-1251 Decode-data transfer type Serial in USB HID mode Parallel…
  • Page 46: Upc-A

    7-5 UPC-A Read: Format System character Data digits (10 digits) Check digit Check digit verification: The check digit is optional. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Code ID is a one-or-two-character string used to represent the symbol upon a succeeding reading.

  • Page 47
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF Code ID setting 00-FF (ASCII) <A>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncation/Expansion…
  • Page 48: Upc-E

    7-6 UPC-E Read: Format System character “0” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.

  • Page 49
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF Code ID setting 00-FF (ASCII) <D>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncate leading zeros…
  • Page 50: Upc-E1

    7-7 UPC-E1 Read: Format System character “1” Data digits (6 digits) Check digits Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.

  • Page 51
    Multiple-scan setting Single-scan setting Alpha. Option barcode Option entry Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF Code ID setting 00-FF (ASCII) <D>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncation/Expansion…
  • Page 52: Isbn/Issn)

    7-8 EAN-13 (ISBN/ISSN) Read: Format Data digits (12 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted. EAN-13 code ID setting: Refer to Code ID setting of UPC-A.

  • Page 53
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-FF EAN-13 code ID setting 00-FF (ASCII) <A>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits Disable…
  • Page 54: Ean-8

    7-9 EAN-8 Read: Format Data digits (7 digits) Check digit Check digit verification: The check digit is optional and made as the sum of the numerical value of the data digits. Check digit trans.: By setting Enable, check digit will be transmitted. Code ID setting: Refer to Code ID setting of UPC-A.

  • Page 55
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit trans. Enable 00-FF Code ID setting 00-FF (ASCII) <C>* 00-66 Insert group selection 00-66 None 2 digits Supplement digits 5 digits 2 or 5 digits None Truncation/Expansion…
  • Page 56: Code 39 (Code 32, Trioptic Code 39)

    7-10 Code 39 (Code 32, Trioptic Code 39) Read: Format Start character (*) Data digits (variable) Check digit (optional) End character (*) Check digit verification: The check digit is optional and made as the sum module 43 of the numerical value of the data digits.

  • Page 57
    Multiple-scan setting Single-scan setting Option barcode Option Alpha.entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <M>* 00-66 Insert group selection 00-66 Standard Format…
  • Page 58
    Multiple-scan setting Single-scan setting Option barcode Option Alpha.entry Code 32 Prefix “A” Disable transmission Enable Disable Trioptic Code 39 read Enable Trioptic Code 39 Start/End Disable transmission Enable…
  • Page 59: Interleaved 2 Of 5

    7-11 Interleaved 2 of 5 Read: Format Data digits (Variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. There are two optional check digit algorithms: the specified Uniform Symbol Specification (USS) and the Optical Product Code Council (OPCC).

  • Page 60
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification OPCC Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <I>* 00-66 Insert group selection 00-66…
  • Page 61: Industrial 2 Of 5 (Discrete 2 Of 5)

    7-12 Industrial 2 of 5 (Discrete 2 of 5) Read: Format Data digits (variable) Max./Min. code length: Refer to Max./Min. code length of 7-10 Code Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.

  • Page 62: Matrix 2 Of 5

    7-13 Matrix 2 of 5 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 10 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.

  • Page 63: Codabar

    7-14 Codabar Read: Format Start character Data digits (variable) Check digit (optional) End character Check digit verification: The check digit is made as the sum module 16 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.

  • Page 64
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry abcd/abcd ABCD/TN*E abcd/tn*e Disable Start/End transmission Enable Disable Start/End character equality Enable…
  • Page 65: Code 128

    7-15 Code 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min. code length: Refer to Max./Min. code length of 7-10 Code Code ID setting: Refer to Code ID setting of UPC-A.

  • Page 66
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable Check digit verification Enable Disable Check digit transmission Reserved 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <K>* 00-66 Insert group selection 00-66 Disable…
  • Page 67: Ucc/Ean 128

    7-16 UCC/EAN 128 Read: Format Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max. /Min. code length: Refer to Max./Min. code length of 7-10 Code Code ID setting: Refer to Code ID setting of UPC-A.

  • Page 68
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Read Disable Enable Check digit verification Disable Enable Check digit transmission Disable Reserved Max. code length 00-99 00-99 Min. code length 00-99 00-99 Code ID setting 00-FF 00-FF (ASCII) <K>* Insert group selection 00-66 00-66 Disable…
  • Page 69: Isbt 128

    7-17 ISBT 128 Read: Format Start character (“=” or “&”) Data digits (variable) Check digit (optional) Check digit verification: The check digit is made as the sum module 103 of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.

  • Page 70: Code 93

    7-18 Code 93 Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The check digit is made as the sum module 47 of the numerical values of all data digits. Check digit transmission: By setting Enable, check digit will be transmitted. Max./Min.

  • Page 71: Code 11

    7-19 Code 11 Read: Format Data digits (variable) Check digit 1 (optional ) Check digit 2 (optional) Check digit verification: The check digit is presented as the sum module 11 of all data digits. Check digit transmission: By setting Enable, check digit 1 and check digit 2 will be transmitted upon your selected check digit verification method.

  • Page 72
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable One digit Check digit verification Reserved Reserved Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting 00-FF (ASCII) <V>* 00-66…
  • Page 73: Msi/Plessey

    7-20 MSI/Plessey Read: Format Data digits (variable) Check digit 1 (optional) Check digit 2 (optional) Check digit verification: The MSI/Plessey has one or two optional check digits. There are three methods of verifying check digits, i.e. Mod 10, Mod 10/10 and Mod 10/11. The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits.

  • Page 74
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable Disable 1 digit (Mod 10) Check digit verification 2 digits (Mod 10/10) 2 digits (Mod 10/11) Disable Check digit transmission Enable 00-99 Max. code length 00-99 00-99 Min. code length 00-99 00-FF Code ID setting…
  • Page 75: Uk/Plessey

    7-21 UK/Plessey Read: Format Data digits (variable) 2 check digits (optional) Check digit verification: The UK/Plessey has one or two optional check digits. The check digit 1 and check digit 2 will be calculated as the sum module 10 or 11 of the data digits. Check digit transmission: By setting Enable, check digit will be transmitted.

  • Page 76: China Post

    7-22 China Post Read: Format 11 Data digits Max. /Min. code length: Refer to Max./Min. code length of 7-10 Code 39. The code length of China Post is 11. Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A.

  • Page 77: China Finance

    7-23 China Finance Note: This type of barcode is not Omni-directionally decodable. The encodable character set includes numeric 0 to 9. Among the symbol of 0 to 9, 0 and 2, 4 and 9, 5 and 8, 6 and 7, have the symmetrical pattern;…

  • Page 78
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Assigned to 0 Assigned to 5(A) Assigned to 6(B) Assigned to 7(C) Leading character assignment Assigned to 8(D) Assigned to 9(E) Assigned to 1 Assigned to 2 Assigned to 3 Assigned to 4 Code ID setting 00-FF…
  • Page 79: Gs1 Databar (Gs1 Databar Truncated)

    7-24 GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Truncated is structured and encoded the same as the standard GS1 DataBar format, except its height is reduced to a 13 modules minimum; while GS1 DataBar should have a height greater than or equal to 33 modules. Read: Format 16 Data digits…

  • Page 80: Gs1 Databar Limited

    7-25 GS1 DataBar Limited Read: Format 16 Data digits Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: Refer to Conversion of 7-24 GS1 DataBar (GS1 DataBar Truncated). Multiple-scan setting Single-scan setting Option barcode…

  • Page 81: Gs1 Databar Expanded

    7-26 GS1 DataBar Expanded Read: Format Data characters (variable) Code ID setting: Refer to Code ID setting of UPC-A. Insertion group selection: Refer to Insertion group selection of UPC-A. Conversion: UCC/EAN 128- Refer to Code ID transmission of 7-36 String transmission, ]Cm will be identified as AIM ID.

  • Page 82: Pdf417

    7-27 PDF417 Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 83: Micropdf417

    7-28 MicroPDF417 Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 84: Qr Code

    7-29 QR Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 85: Micro Qr Code

    7-30 Micro QR Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Parameters Alpha. Option barcode Option of the code entry Disable Read 0x11 0x95 Enable 00-FF Code ID setting 00-FF 0x11 0x96 (ASCII) <q>*…

  • Page 86: Data Matrix

    7-31 Data Matrix Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 87: Han Xin Code

    7-32 Han Xin Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 88: Aztec Code

    7-33 Aztec Code Read: Format Data characters (variable) Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Disable Read Enable…

  • Page 89: G1-G6 & C1-C3 & Fn1 Substitution String Setting

    7-34 G1-G6 & C1-C3 & FN1 substitution string setting Format of barcode data transmission: Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Suffix string setting: The <enter > key is represented in different ASCII when it is applied by different OS.

  • Page 90
    Truncate leading G5 string setting: By setting, a defined leading character or string can be truncated. Also a single character can be un-defined. Repeat of a G5 character setting: While G5 is set as a single defined/un-defined character, G5 can also be set to be repeated.
  • Page 91
    Steps: scan the following barcodes in order. The ASCII value for “A” is 41, for “B” is 42, for “C” is 43, for “D” is “44”, for “E” is 45, and for “F” is 46. Testing barcode:…
  • Page 92
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. Entry 0-22 characters 00-FF Prefix string setting None 0-22 characters 00-FF Suffix string setting <ENTER> 0D0A* Preamble string setting 0-22 characters 00-FF None Postamble string setting 0-22 characters 00-FF None 0-22 characters 00-FF Insert G1 string setting None…
  • Page 93
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. Entry Defined times 01-22 Un-defined times (All) A un-defined character Truncate ending G6 string setting 1-22 defined 01-7F characters <0> Once Repeat of a G6 character setting Defined times 01-22 Un-defined times (All) Single character C1 0000* replacement…
  • Page 94: G1-G4 String Position & Code Id Position

    7-35 G1-G4 string position & Code ID position Format of barcode data transmission: Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Insert G1/G2/G3/G4 string position: The terminal offers 4 positions to insert strings among the symbol. In case of the insertion position is greater than the length of the symbol, the insertion of string is not effective.

  • Page 95: String Transmission

    7-36 String transmission Note: The information in this chapter is closely related to 7-33 G1-G6 & C1-C3 & FN1 substitution string setting. Format of barcode data transmission: Prefix Code name Preamble Code ID Code length Code data Code ID Postamble Suffix Prefix transmission: By setting Enable, prefix will be appended before the data transmitted.

  • Page 96
    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Prefix transmission Disable Enable Suffix transmission Disable Enable Disable Code name transmission Enable Preamble transmission Disable Enable Postamble transmission Disable Enable Disable Code ID transmission Proprietary ID AIM ID Code length transmission Disable Enable Disable…
  • Page 97: Barcode Representing Non-Printable Character

    Multiple-scan setting Single-scan setting Option barcode Option Alpha. entry Keyboard wedge/USB RS-232 Keyboard wedge / USB/RS-232 All-non-printable-character Disable string transmission with string setting Enable Transmit the first N data characters only 01-99 Transmit the last N data characters only 01-99 8 Barcode representing non-printable character Notes to make the following barcode: 1.

  • Page 98
    Enter Insert Delete…
  • Page 99: Ascii Table

    9 ASCII Table for keyboard wedge for RS-232 Null Down Left Right PgUp PgDn Home Enter Insert Ctrl+ Delete Alt+ Notes: The 2nd and the 3rd columns above are used for keyboard wedge only. “ & ‘ < > Example: ASCII “A” = “41”.

  • Page 100: Enable & Disable Configuration By Scanning Barcode

    10 Enable & Disable configuration by scanning barcode Note: The setting of the below two barcodes does affect the operation of scanning the barcodes in 13 Return default parameters & firmware version. Enable configuration by scanning barcode (Default) The default status of the embedded scanner is enabled to scan configuration barcode. Disable configuration by scanning barcode Scan the above barcode to disable scanning configuration barcode, then the embedded scanner will not operate configuration by scanning configuration barcodes, but the data string of…

  • Page 101: Enable & Disable «Nr

    Enable & Disable “NR” Enable “NR” If it is enabled, while the scanner receives the STOP_DECODE command or fails to decode a barcode within the Stand-by duration time, the scanner will transmit “NR”. Disable “NR” (Default)

  • Page 102: Test Chart

    Test Chart UPC-A UPC-E UPC-E1 EAN-13 ISBN/ISSN EAN-8 Code 39 Code 32 A908765439 Trioptic Code 39 (Default setting: Disable) Interleaved 2 of 5 Industrial 2 of 5 (Default setting: Disable) Matrix 2 of 5 Codabar Test Chart (Continued)

  • Page 103
    Code 128 UCC/EAN 128 ISBT 128 Code 93 Code 11 (Default setting: Disable) MSI/Plessey (Default setting: Disable) UK/Plessey China Post Telepen GS1 DataBar (GS1 DataBar Truncated) GS1 DataBar Limited GS1 DataBar Expanded…
  • Page 104: Return Default Parameters & Firmware Version

    13 Return default parameters & firmware version WARNING: Restore Factory Defaults Scan this barcode to restore the factory default values. Firmware Version List Scan this barcode to display the firmware version.

  • Page 105: Configuration Alphanumeric Entry Barcode

    14 Configuration alphanumeric entry barcode To finish parameter setting, please scan the bar code below.

Скачать прошивки, драйверы и руководства по эксплуатации
для сканеров Mindeo

ВНИМАНИЕ! Модель и модификация сканера чувствительны к версии прошивки и приложения.

Сканер может быть поврежден в случае использования некорректного файла, гарантийный ремонт в этом случае не осуществляется.

Перед загрузкой ПО/перепрошивкой сканера проверьте, что загружаете соответствующую вашей модели сканера версию прошивки/приложения.

Mindeo MS3690
Для модели MS3690 нельзя использовать файлы от модели MS3690 Mark,
для модели с Bluetooth нельзя использовать прошивку WiFi и наоборот, для модели с 1D прошивку от 2D (и наоборот).

Mindeo MD6600 и MP725
Для модели MD6600 нельзя использовать прошивку от MD6600S, для MP725 от MP725S (и наоборот).
Прошивки для модификаций сканеров с индексом «S» имеют следующую маску Модель сканера_APP_V2.х.х_Release.bin.

Ознакомьтесь с отличиями модификаций сканеров MD6600 / 6600S и MP725 / 725S.
Нажмите, чтобы посмотреть.

При нарушении указанной в руководстве процедуры при самостоятельном обновлении пользователем встроенного программного обеспечения (перепрошивки) возможно повреждение устройства.
В этом случае его ремонт производится на платной основе.

Обновление «прошивки» сканера MINDEO MD6600

Обновление «прошивки» сканера MINDEO CS2290

Серия Mindeo MD6600

Дата обновления прошивки: 13.07.2021

Серия Mindeo MD6600S

Дата обновления прошивки: 10.08.2023

Серия Mindeo MP725

Дата обновления прошивки: 17.09.2020

Серия Mindeo MP725S

Дата обновления прошивки: 01.11.2022

Серия Mindeo MP86XX

Дата обновления прошивки: 10.08.2023

Серия Mindeo CS2290BT

Данная прошивка совместима только с Bluetooth версией CS2290 с прошивками версий _APP_V2.х.х_Release.bin
Визуально проверить поколение (модификацию) CS2290 можно аналогичным MD6600 способом – лампы подсветки для версии «S» будут ниже фотолинзы

Дата обновления прошивки: 24.02.2022

Утилита для перепрошивки сканеров серий Mindeo MD и MP

Дата обновления прошивки: 03.06.2019

Прошивки и утилита для серии Mindeo MS3690 (CITYSOFT Lite) *

Дата обновления прошивки: 20.07.2022

* Обратите внимание! Прошивка, утилита и инструкция по прошивке для серий Mindeo MS3690 и Mindeo MS3690 Mark содержатся в составе дистрибутива CTsoft Lite.

Драйвер

Драйвер виртуального COM-порта для компьютеров под управлением Windows можно скачать на сайте производителя.

Если у вас проблемы с подключением, настройкой или сканированием, посетите нашу Базу знаний

  • Наверх

  • Прошивки

  • Драйвер

  • Форум

Преимущества сервиса Port

Авторизованный сервисный центр для 22 производителей

Услуги по монтажу, настройке, ремонту всего спектра оборудования

Аккредитованные специалисты

Доставка оборудования в сервисный центр

БОЛЬШЕ О СЕРВИСНОМ ЦЕНТРЕ

Обязательная гарантия на услуги

Наша компания является авторизованным сервисным центром, поэтому мы всегда следим за качеством своего обслуживания.Воспользовавшись нашими услугами вы получаете:

Штат специалистов, готовый ответить на вопросы

Бесплатный выезд специалиста

Актуальную документацию по обслуживанию оборудования

БОЛЬШЕ О СЕРВИСНОМ ЦЕНТРЕ

Вам могут быть интересны:

Понравилась статья? Поделить с друзьями:
  • Mindeo cs3290 инструкция на русском
  • Mindeo cs2x90bt инструкция на русском
  • Mindeo cs2290 sr bt инструкция
  • Mind booster инструкция по применению на русском
  • Minco heat терморегулятор инструкция на русском