Msc ga35vb инструкция по монтажу

  1. Manuals
  2. Brands
  3. Mitsubishi Electric Manuals
  4. Air Conditioner
  5. MU-GA35VB

Manuals and User Guides for Mitsubishi Electric MU-GA35VB. We have 4 Mitsubishi Electric MU-GA35VB manuals available for free PDF download: Manual, Service Technical Manual, Installation Manual

Mitsubishi Electric MU-GA35VB Manual

Mitsubishi Electric MU-GA35VB Manual (586 pages)

Brand: Mitsubishi Electric
|
Category: Air Conditioner
|
Size: 56.92 MB

Table of Contents
  • Back to Index Page C.1 Wall-Mounted

    5

    • Table of Contents

      5

    • Cooling Only

      7

    • Fixed Speed Heat Pump

      9

    • Inverter Heat Pump

      11

    • Outlines and Dimensions

      18

      • Indoor Unit

        19

      • Outdoor Unit

        24

      • Indoor Unit

        27

      • Outdoor Unit

        33

    • Refrigerant System Diagram

      52

      • Cooling Only

        52

      • Fixed Speed Heat Pump

        55

      • Inverter Heat Pump

        58

    • Performance Curves

      64

      • Cooling Only

        65

      • Fixed Speed Heat Pump

        68

      • Inverter Heat Pump

        72

      • Powerful Heating Heat Pump

        78

    • Performance Data

      87

      • Cooling Only

        87

      • Fixed Speed Heat Pump

        99

      • Inverter Heat Pump

        112

    • Noise Criteria Curves

      143

      • Indoor Unit

        147

      • Outdoor Unit

        152

    • Troubleshooting

      155

      • Cooling Only/Fixed Speed Heat Pump

        155

      • Inverter Heat Pump

        157

    • Installation Procedure

      170

      • Cooling Only/Fixed Speed Heat Pump

        170

      • Inverter Heat Pump

        183

    • Operation and Actuator Control

      195

      • MSC/MS/MSH Series

        195

      • MSZ-FD . VA/S Series

        204

      • MSZ-GE . VA Series

        215

      • MSZ-HC . VA/VAB Series

        223

      • MSZ-SF . VA Series

        228

    • Center of Gravity Position

      235

    • Capacity Correction Ratio Curve for Piping Length

      236

  • Back to Index Page C.2 Floor-Standing

    237

    • Indoor Unit

      239

    • Outdoor Unit

      239

    • Wiring Diagram

      241

      • Indoor Unit

        241

      • Outdoor Unit

        242

    • Refrigerant System Diagram

      245

    • Performance Curves

      247

      • Inverter Heat Pump

        248

    • Performance Data

      251

      • Inverter Heat Pump

        251

    • Noise Criteria Curves

      258

      • Inverter Heat Pump

        258

    • Troubleshooting

      259

      • Inverter Heat Pump

        259

    • Installation Procedure

      263

    • Operation

      267

      • MFZ-KA VA Series

        267

    • Center of Gravity Position

      275

    • Capacity Correction Ratio Curve for Piping Length

      276

  • Back to Index Page C.3 Ceiling Cassette

    277

    • Indoor Unit

      280

    • Wiring Diagram

      280

      • Indoor Unit

        281

    • Refrigerant System Diagram

      281

      • Inverter Heat Pump

        281

    • Noise Criteria Curves

      282

      • Inverter Heat Pump

        283

    • Troubleshooting

      283

      • Inverter Heat Pump

        288

    • Installation Procedure

      288

    • Operation

      295

      • MLZ-KA • VA Series

        295

Advertisement

Mitsubishi Electric MU-GA35VB Service Technical Manual

Mitsubishi Electric MU-GA35VB Service Technical Manual (164 pages)

Brand: Mitsubishi Electric
|
Category: Air Conditioner
|
Size: 2.59 MB

Table of Contents
  • Table of Contents

    2

  • Msc-Ca35Vb Msc-Cb35Vb Msc-Ga35Vb Mu-Ga35Vb Muh-Ga35Vb Mux-3A60Vb

    6

    • Msc Microprocessor Control

      6

      • Cool Operation

        6

      • Dry Operation

        7

      • Fan Operation

        8

      • Heat Operation

        8

      • 1-5.»I Feel Control» Operation

        9

      • Indoor Fan Motor Control

        11

      • Auto Vane Operation

        11

      • Timer Operation

        12

      • Emergency / Test Operation

        13

      • Outdoor Unit Actuator Control

        14

    • Ms Microprocessor Control

      15

  • Ms-Ga50Vb Mu-Ga50Vb

    15

  • Ms-Ga60Vb Mu-Ga60Vb

    15

  • Ms-Ga80Vb Mu-Ga80Vb

    15

    • I Feel Control» Operation

      15

      • Cool Operation

        18

      • Dry Operation

        19

      • Fan Operation

        19

      • Indoor Fan Motor Control

        19

      • Auto Vane Operation

        19

      • Timer Operation

        22

      • Emergency / Test Operation

        23

      • Expansion Valve Control (Lev Control)

        24

      • Function of Soft Start Relay

        25

    • Msh Microprocessor Control

      26

  • Msh-Ca50Vb Msh-Ga50Vb Muh-Ga50Vb

    26

  • Msh-Cb50Vb Msh-Ga60Vb Muh-Ga60Vb

    26

    • Msh-Ga80Vb Muh-Ga80Vb

      26

    • I Feel Control» Operation

      26

    • Cool Operation

      32

    • Dry Operation

      32

    • Heat Operation

      32

    • Indoor Fan Motor Control

      32

    • Auto Vane Operation

      33

    • Timer Operation

      35

    • Emergency / Test Operation

      36

    • Expansion Valve Control (Lev Control)

      37

    • Function of Soft Start Relay

      38

    • Msz-Ca Microprocessor Control

      39

  • Msz-Ca25Vb Muz-Ca25Vb Msz-Ca35Vb Muz-Ca35Vb

    39

    • I Feel Control» Operation

      39

      • Auto Change over

        44

      • Cool Operation

        45

      • Dry Operation

        45

      • Heat Operation

        45

      • Indoor Fan Motor Control

        46

      • Auto Vane Operation

        46

      • Timer Operation

        47

      • Emergency / Test Operation

        48

      • Inverter System Control

        49

      • Operation Frequency Control of Outdoor Unit

        51

      • Expansion Valve Control (Lev Control)

        52

    • Msz-Fa Microprocessor Control

      54

  • Msz-Fa25Va Muz-Fa25Va Muz-Fa25Vah

    54

  • Msz-Fa35Va Muz-Fa35Va Muz-Fa35Vah

    54

    • Cool Operation

      55

    • Dry Operation

      56

    • Heat Operation

      56

    • Auto Change over

      58

    • Indoor Fan Motor Control

      59

    • Outdoor Fan Motor Control

      59

    • Auto Vane Operation

      59

    • I-See CONTROL OPERATION

      61

    • Area Setting

      62

    • Plasma Duo Operation

      64

    • Auto Front Panel

      65

    • Timer Operation

      65

    • Emergency / Test Operation

      66

    • Inverter System Control

      67

    • Operational Frequency Control of Outdoor Unit

      69

    • Expansion Valve Control (Lev Control)

      70

    • Msz-Ga, Msz-Cb Microprocessor Control

      72

  • Msz-Ga22Va Msz-Cb22Va

    72

  • Msz-Ga25Va Msz-Cb25Va Muz-Ga25Va Muz-Ga25Vah

    72

  • Msz-Ga35Va Msz-Cb35Va Muz-Ga35Va Muz-Ga35Vah

    72

    • Cool Operation

      73

    • Dry Operation

      74

    • Heat Operation

      74

    • Auto Change over

      76

    • Indoor Fan Motor Control

      77

    • Outdoor Fan Motor Control

      77

    • Auto Vane Operation

      77

    • Timer Operation

      79

    • Emergency/Test Operation

      80

    • Inverter System Control

      81

    • Operational Frequency Control of Outdoor Unit

      83

    • Expansion Valve Control (Lev Control)

      84

  • Msz-Ga50Va Muz-Ga50Va

    86

  • Msz-Ga60Va Muz-Ga60Va

    86

  • Msz-Ga71Va Muz-Ga71Va

    86

    • Cool Operation

      86

    • Dry Operation

      87

    • Heat Operation

      88

    • Auto Change over

      90

    • Indoor Fan Motor Control

      90

    • Outdoor Fan Motor Control

      91

    • Auto Vane Operation

      91

    • Timer Operation

      94

    • Emergency/Test Operation

      95

    • Inverter System Control

      95

    • Operational Frequency Control of Outdoor Unit

      97

    • Expansion Valve Control (Lev Control)

      98

    • Mcf Microprocessor Control

      100

  • Mcf-Ga35Vb Mucf-Ga35Vb

    100

  • Mcf-Ga50Vb Mucf-Ga50Vb

    100

  • Mcf-Ga60Vb Mucf-Ga60Vb

    100

    • I Feel Control» Operation

      100

      • Cool Operation

        103

      • Dry Operation

        103

      • Fan Operation

        103

      • Auto Vane Operation

        103

      • Timer Operation

        105

      • Emergency / Test Operation

        105

    • Mcfh Microprocessor Control

      106

  • Mcfh-Ga35Vb Mucfh-Ga35Vb

    106

  • Mcfh-Ga50Vb Mucfh-Ga50Vb

    106

  • Mcfh-Ga60Vb Mucfh-Ga60Vb

    106

    • I Feel Control» Operation

      106

      • Cool Operation

        110

      • Dry Operation

        111

      • Heat Operation

        111

      • Auto Vane Operation

        111

      • Timer Operation

        113

      • Emergency / Test Operation

        114

    • Mfz Microprocessor Control

      115

  • Mfz-Ka25Va Mfz-Ka35Va Mfz-Ka50Va

    115

    • Cool Operation

      116

    • Dry Operation

      117

    • Heat Operation

      117

    • Auto Change over

      119

    • Indoor Fan Motor Control

      120

    • Outdoor Fan Motor Control

      120

    • Auto Vane Operation

      120

    • I-Save OPERATION

      124

    • Timer Operation

      125

    • Emergency / Test Operation

      126

    • Msz-Ha Microprocessor Control

      127

  • Msz-Ha25Va Muz-Ha25Va Msz-Ha35Va Muz-Ha35Va

    127

    • Cool Operation

      128

    • Dry Operation

      128

    • Heat Operation

      129

    • Indoor Fan Motor Control

      130

    • Auto Vane Operation

      131

    • Timer Operation

      133

    • Emergency/Test Operation

      133

    • Inverter System Control

      134

    • Operational Frequency Control of Outdoor Unit

      136

    • Msz-Gb Microprocessor Control

      137

  • Msz-Gb50Va Muz-Gb50Va

    137

    • Cool Operation

      138

    • Dry Operation

      139

    • Heat Operation

      139

    • Auto Change over

      141

    • Indoor Fan Motor Control

      141

    • Outdoor Fan Motor Control

      142

    • Auto Vane Operation

      142

    • Timer Operation

      144

    • Emergency/Test Operation

      145

    • Inverter System Control

      145

    • Operational Frequency Control of Outdoor Unit

      147

    • Expansion Valve Control (Lev Control)

      148

  • Mxz-5A100Va

    150

  • Mxz-4A80Va

    150

  • Mxz-2A52Va

    150

  • Mxz-2A30Va

    150

    • Mxz Microprocessor Control

      150

  • Mxz-2A40Va

    150

  • Mxz-3A54Va

    150

  • Mxz-4A71Va

    150

    • Inverter System Control

      150

    • Expansion Valve Control (Lev Control)

      153

    • Operational Frequency Range

      159

    • Heat Defrosting Control

      160

    • Discharge Temperature Protection Control

      161

    • Refrigerant Recovery Control on Heating

      161

    • Outdoor Fan Control

      161

    • Pre-Heat Control

      162

    • Cool Operation

      162

    • Dry Operation

      163

    • Heat Operation

      163

Mitsubishi Electric MU-GA35VB Installation Manual

Mitsubishi Electric MU-GA35VB Installation Manual (4 pages)

Brand: Mitsubishi Electric
|
Category: Air Conditioner
|
Size: 0.59 MB

Advertisement

Mitsubishi Electric MU-GA35VB Installation Manual

Mitsubishi Electric MU-GA35VB Installation Manual (4 pages)

Brand: Mitsubishi Electric
|
Category: Air Conditioner
|
Size: 0.38 MB

Advertisement

Related Products

  • Mitsubishi Electric MU-GA35VB-E1

  • Mitsubishi Electric MU-GA50VB

  • Mitsubishi Electric MU-GA60VB

  • Mitsubishi Electric MU-GA80VB

  • Mitsubishi Electric MU-GA25VB-E1

  • Mitsubishi Electric MU-GA20VB-E1

  • Mitsubishi Electric MU-GA25VB-E2

  • Mitsubishi Electric MU-GA20VB

  • Mitsubishi Electric MU-GA25VB

  • Mitsubishi Electric MU-GA60VB-E1

Mitsubishi Electric Categories

Air Conditioner
Air Conditioner

Controller

Projector
Projector

Inverter

Heat Pump

More Mitsubishi Electric Manuals

  • Руководства по ремонту

    1

  • Инструкции по эксплуатации

    1

Preview

Mitsubishi MSC-GA35VB инструкция по установке
(1 страница)

  • Языки:Русский
  • Тип:
    PDF
  • Размер:
    548.06 KB

Просмотр

Mitsubishi MSC-GA35VB (Кондиционеры) сервис мануалы в PDF-формате помогут найти неполадки и ошибки, а также осуществить ремонт Mitsubishi MSC-GA35VB и восстановить работу устройства.

 

Параметры модели  

Внутренний блок  

MSC-GA35VB

Наружный блок 

MU-GA35VB

Холодопроизводительность ,кВт 

3,45

Теплопроизводительность,  кВт 

Потребляемая мощность (охлаждение), кВт 

1,12

Потребляемая мощность (обогрев), кВт 

Расход воздуха (мин.), м3/ч 

324

Расход воздуха (макс.), м3/ч 

582

Уровень шума (мин.), дБ(А) 

26

Уровень шума (макс.), дБ(А) 

                          40

Вес вн./нар., кг 

10/34

Габариты внутренний блок  ШхДхВ, мм 

815x244x278

Габариты наружний блок  ШхДхВ, мм 

800х285х550 

Напряжение питания: В, ф, Гц 

220-240 В, 1 ф, 50 Гц 

Максимальный рабочий ток, А 

7,7

Диаметр труб (жидкость) 

6.35 (1/4) 

Диаметр труб (газ) 

9.52 (3/8) 

Диаметр дренажа 

16 

Максимальная длина магистрали, м 

25 

Максимальный перепад высот, м 

10

Гарантированный диапазон наружных температур: охлаждение 

+21 … +43°C 

Страна производитель 

Таиланд 

  • Корпус моделей серии GE изготовлен изготовлен из высококачественной пластмассы, имеющей гладкую полированную поверхность. 
  • Низкий уровень шума — от 26 дБ(А).

      •   Достигнута высокая энергоэффективность в классе безынверторных систем. 

  • Значительные возможности по длине магистрали хладагента и перепаду высот.

       •  Антиоксидантный фильтр замедляет процессы старения.

  Документация 


   Руководство по эксплуатации MSC-GE35VB (2.53 МБ)

   Инструкция по установке MSC-GE35VB (0.37 МБ)

Опции  

  1. MAC-1300FT — Электростатический фильтр (срок службы не более 4 месяцев)
  • Сплит-кондиционеры Mitsubishi Electric серии MSC...

    Mitsubishi Electric

    Внутренние блоки сплит-кондиционеров серии MSC-GE20VB, MSC-GE25VB, MSC-GE35VB. Инструкция по эксплуатации.

  • Сплит-кондиционеры Mitsubishi Electric серии MSC...

    Mitsubishi Electric

    Cплит-кондиционеры серии MSC-GE20VB / MU(H)-GA20VB, MSC-GE25VB / MU(H)-GA25VB, MSC-GE35VB / MU(H)-GA35VB. Руководство по установке.

  • Сплит-кондиционеры Mitsubishi Electric серии MSC...

    Mitsubishi Electric

    Внутренние блоки сплит-кондиционеров серии MSC-07RV, MSC-09RV, MSC-12RV, MSC-C07TV,
    MSC-C09TV, MSC-C12TV. Руководство по эксплуатации.

  • Сплит-кондиционеры Mitsubishi Electric серии MSC...

    Mitsubishi Electric

    Внутренние блоки сплит-кондиционеров серии MSC-GA20VB, MSC-GA25VB, MSC-GA35VB. Руководство по эксплуатации.

  • Сплит-кондиционеры Mitsubishi Electric серии MSC...

    Mitsubishi Electric

    Внутренние блоки сплит-кондиционеров серии MSC-A07YV, MSC-A09YV, MSC-A12YV. Руководство по эксплуатации.

Installation place

Avoid installing the air conditioner in the following places.

• Where flammable gas could leak.

CAUTION:

Do not install the unit where flammable gas could leak.

If gas leaks and collects around the unit, it may cause

an explosion.

• Where there is much machine oil.

• Salty places such as the seaside.

• Where sulfide gas is generated such as a hot spring.

• Where oil is splashed or where the area is filled with

oily smoke.

• Where there is high-frequency or wireless equipment.

• Where the unit will be buried in snow.

• Inside the mobile vehicles such as a crane truck, ship, etc.

• Drain the water from the unit to the soil which has good drainage.

• Cooling and heating capacity may get lowered 10% in the places where poor ventilation and shortcycle of air exchange is likely to occur.

WARNING :

If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since

there may be a refrigerant leak. Be sure to ask the service representative whether there is refrigerant leakage or not

when repairs are carried out.

The refrigerant charged in the air conditioner is safe. Refrigerant normally does not leak, however, if refrigerant gas leaks

indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.

Electrical work

• Provide an exclusive circuit for the power supply of the air conditioner.

• Be sure to observe the breaker capacity.

WARNING :

• The customer should not install this unit.

If installation is done incorrectly, it may cause a fire, an electric shock, or injury from the unit falling, water leaking, etc.

• Do not use intermediate connection of the power supply cord or the extension cord and do not connect many

devices to one AC outlet.

A fire or an electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.

Consult your dealer.

SPECIFICATIONS

Set name

MSH-GA20VB

Model

Indoor

MSC-GA20VB

Outdoor

MUH-GA20VB

Function

Cooling

Power supply

Capacity

kW

2.3

Input

kW

0.715

Indoor

kg

Weight

Outdoor

kg

Refrigerant filling

kg

capacity (R410A)

Indoor

IP code

Outdoor

Permissible

LP ps

MPa

excessive

operating

HP ps

MPa

pressure

Indoor

dB(A)

Noise level

(High/Med./Low)

Outdoor

dB(A)

The installation location of the outdoor unit should be

at least 3 m away from the antennas for TV sets,

radios, etc. In areas where the reception is weak, pro-

Inverter-type

vide greater space between the outdoor unit and the

antenna of the affected device if operation of the air

fluorescent lamp

To prevent the effects

conditioner interferes with radio or TV reception.

of a fluorescent lamp,

keep as far apart as

possible.

Keep a space

to prevent the

picture

distortion or

100 mm or

the noise.

more

1 m

or more

TV

1 m

or more

Cordless

phone or

Portable

Radio

3 m

phone

or more

MSH-GA25VB

MSH-GA35VB

MSC-GA25VB

MSC-GA35VB

MUH-GA25VB

MUH-GA35VB

Heating

Cooling

Heating

Cooling

2.5

2.65

3.0

3.5

0.69

0.82

1.09

9

32

0.65

0.80

36/31/25

36/31/25

39/32/25

40/33/26

47

49

CAUTION:

• Earth the unit.

Do not connect the earth to a gas pipe, water pipe, lightning rod or the earth of a telephone. If the earthing is

incorrect, it may cause an electric shock.

wall, etc.

• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid places, etc.).

If the earth leakage breaker is not installed, it may cause an electric shock.

Well-

ventilated

dry place

Inspection and maintenance

• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.

500 mm or

• Depending on the condition, an odor may be generated or dehumidified water may not drain out smoothly due to dirt,

more

dust, etc. This may cause water leakage from the unit.

• It is recommended that the unit be inspected and maintained (charged) by specialist in addition to normal maintenance.

Consult your dealer.

Operating sound considerations

• Do not put an object around the air outlet of the outdoor unit. This may lower the capacity or increase the volume of the

operating sound.

• If an abnormal sound is heard during operation, consult your dealer.

• Choose the place which endures the unit weight enought and does not amplify the unit vibration.

• Choose the place in which the operation sound and air blow from the unit don’t bother the house next door.

Relocation

• When the air conditioner is to be removed or re-installed because of rebuilding, moving, etc., special techniques and

work are required.

WARNING :

Repairs or relocation should not be done by the customer.

If this is done incorrectly, it may cause a fire, an electric shock, or an injury from the unit falling, water leaking, etc.

Consult your dealer.

Disposal

To dispose of this product, consult your dealer.

MS-GA20VB

MS-GA25VB

MSC-GA20VB

MSC-GA25VB

MU-GA20VB

MU-GA25VB

Heating

Cooling

~ /N, 230V, 50Hz

2.3

3.7

1.02

0.715

10

9

35

31

0.60

IP20

IP24

1.64

4.15

36/31/25

39/33/26

45

If you have any questions, consult your dealer.

NOTE:

MS-GA35VB

1. Rating condition

MSC-GA35VB

MU-GA35VB

Cooling —

Heating —

2.5

3.45

0.775

1.12

10

2. Guaranteed operating range

30

0.60

0.70

Cooling

Heating

40/33/26

49

Indoor:

27°C DB, 19°C WB

Outdoor: 35°C DB

Indoor:

20°C DB

Outdoor: 7°C DB, 6°C WB

Indoor

Outdoor

32°C DB

43°C DB

Upper limit

23°C WB

21°C DB

21°C DB

Lower limit

15°C WB

27°C DB

24°C DB

Upper limit

18°C WB

20°C DB

-10°C DB

Lower limit

-11°C WB

11

Понравилась статья? Поделить с друзьями:
  • Mr techno baby smile инструкция
  • Mr sandman кроватка с маятником инструкция
  • Mr proper инструкция по применению
  • Mr proper для пола инструкция
  • Mr muscle для прочистки сливных труб всех видов инструкция по применению