49 thoughts on “Instruction Manual Download”
-
Mouhib hajjar May 13, 2021 Kindly send us a user manual in Arabic
-
Mouhib hajjar May 13, 2021 Kindly send us a user manual in Arabic
-
enmustee Post authorJune 2, 2021 Which product do you need the Arabic manual?
-
-
HASSANAIN July 6, 2021 I need the upgrade software link for PV3500 , 4k must invertor
-
HASSANAIN July 6, 2021 I need the upgrade software link for PV3500 , 4k must invertor
-
enmustee Post authorJuly 8, 2021 Is This What You Want ?
———— https://en.must-ee.com/archives/24
-
-
hddar al jahour August 22, 2021 PV1800 5248 PRO DOESNT RESTART IT SELF AFTER OVERLOAD … I ENABLED AUTORESTART IN ITS SOFTWARE BUT STILL NO RESTART … IT takes about 30 munite to restart
-
hddar al jahour August 22, 2021 PV1800 5248 PRO DOESNT RESTART IT SELF AFTER OVERLOAD … I ENABLED AUTORESTART IN ITS SOFTWARE BUT STILL NO RESTART … IT takes about 30 munite to restart
-
enmustee Post authorAugust 23, 2021 hello, problem has been reported.
-
-
Martin August 22, 2021 I need manual for model EP 11-2400PRo 24Vdc input inverter. It displays error code 4. What does error code 4 mean?
-
Martin August 22, 2021 I need manual for model EP 11-2400PRo 24Vdc input inverter. It displays error code 4. What does error code 4 mean?
-
enmustee Post authorAugust 23, 2021 by: https://drive.google.com/file/d/1IP9yKHyYPyq5v86WQ6MY-KW4pDsR94lr/view
-
-
Sam August 30, 2021 Where can I find the documentation of pv1800 VHM holding registers definitions ?
-
Sam August 30, 2021 Where can I find the documentation of pv1800 VHM holding registers definitions ?
-
enmustee Post authorSeptember 1, 2021 Do you mean WIFI description?
-
Tamer Moustafa September 16, 2021 please what is the pass word for the soft ware solar power monitor for PV1800 VPK 3 KW
-
Tamer Moustafa September 16, 2021 please what is the pass word for the soft ware solar power monitor for PV1800 VPK 3 KW
-
enmustee Post authorJanuary 24, 2022 Hi, Tamer
The password is set by yourself, you can also send your wifi device code to your sales to ask for re-set.
Best regards,
MUST
-
-
-
-
Tamer Moustafa September 16, 2021 what is the password for software SolarPowerMonitor2.2.81 for PV1800VPK 3 KW
-
Tamer Moustafa September 16, 2021 what is the password for software SolarPowerMonitor2.2.81 for PV1800VPK 3 KW
-
enmustee Post authorSeptember 17, 2021 SolarPowerMonitor no password required
-
-
edgardo November 9, 2021 buenos dias saludos como hago para bajar el manual del inversor PV 1800. MD: PV18 3kw vpm
-
edgardo November 9, 2021 buenos dias saludos como hago para bajar el manual del inversor PV 1800. MD: PV18 3kw vpm
-
enmustee Post authorNovember 15, 2021 https://drive.google.com/file/d/1NIE6cWQhSPSJGCtxcDLBdj0HJw6kWx3X/view?usp=sharing
-
-
Ioan November 10, 2021 Where can I find the documentation of pv1800 VHM registers for wifi monitoring?
I have a HF2211 RS485 to wifi device and planning to use it to monitor my solar inverter
Thank you-
Ioan November 10, 2021 Where can I find the documentation of pv1800 VHM registers for wifi monitoring?
I have a HF2211 RS485 to wifi device and planning to use it to monitor my solar inverter
Thank you-
enmustee Post authorJanuary 24, 2022 Hi Ioad,
Pls find vedio of WIFI registration in this link.
Best regards,
MUST
-
-
Ioan Kiss November 10, 2021 Where can I find the documentation of pv1800 VHM registers for wifi monitoring?
I have a HF2211 RS485 to wifi device and planning to use it to monitor my solar inverter
Thank you-
Ioan Kiss November 10, 2021 Where can I find the documentation of pv1800 VHM registers for wifi monitoring?
I have a HF2211 RS485 to wifi device and planning to use it to monitor my solar inverter
Thank you-
enmustee Post authorNovember 15, 2021 https://drive.google.com/file/d/1nd3IZp6st0q4k_n0i7gOYXgTvt_qu8Vc/view?usp=sharing
-
Ioan Kiss November 15, 2021 My inverter des not have such a USB input
I would like to use it with the RS-485 output and my 3rd party Modbus-RTU device. I just need to know the inverter address for Modbus TCP protocol.
Thank you-
Ioan Kiss November 15, 2021 My inverter des not have such a USB input
I would like to use it with the RS-485 output and my 3rd party Modbus-RTU device. I just need to know the inverter address for Modbus TCP protocol.
Thank you-
Ioan Kiss November 15, 2021 This is the inverter I have (without the WIFI RTU module) – https://www.pni.ro/invertor-solar-pni-greenhouse-sc1800b-3kw-24v-60a-mppt-off-grid-hibrid-sinus-pur-cu-modul-wifi-pentru-conectare-internet-inclus.html
-
enmustee Post authorNovember 17, 2021 I will forward the problem to a colleague, please pay attention to your email.
-
enmustee Post authorNovember 17, 2021 I will forward the problem to a colleague, please pay attention to your email.
-
Sergey Kaydalov January 19, 2022 Could you share Modbus RTU registers with me as well? I want to integrate the PV1800 VPK device with Home Assistant software.
-
enmustee Post authorJanuary 24, 2022 Hello, we will contact you by email!
-
enmustee Post authorJanuary 24, 2022 Hello, we will contact you by email!
-
Sergey Kaydalov January 19, 2022 I would like to have these modbus registers description as well. Working on integration with Home Assistant software.
-
enmustee Post authorJanuary 24, 2022 Hi, Sergey
Please check email with WIFI details.
Thanks,
MUST
-
-
-
-
-
enmustee Post authorJanuary 24, 2022 Hi, Sergey
Please check email with WIFI details.
Thanks,
MUST
-
-
-
-
-
Yibeltal December 11, 2021 Please send me Installation & Operation Manual for PV30-3024MPK Solar Inverter.
Thank you
-
enmustee Post authorDecember 20, 2021 https://drive.google.com/file/d/10puJfjtiMCUWhadVMsp52xoR5m10qiUo/view?usp=sharing
-
-
enmustee Post authorDecember 20, 2021 https://drive.google.com/file/d/10puJfjtiMCUWhadVMsp52xoR5m10qiUo/view?usp=sharing
-
-
Juergen Bitzer December 14, 2021 Have 2 MUST-PV18-3024-PVK.
They are very bad calibrated and they show Voltage errors off up to 1 volt.
Need Software to calibrate them.
Thanks !-
enmustee Post authorJanuary 24, 2022 Hi, Juergen
Please contact your seller to check repair details and parts.
Best regards,
MUST
-
-
enmustee Post authorJanuary 24, 2022 Hi, Juergen
Please contact your seller to check repair details and parts.
Best regards,
MUST
-
-
enmustee Post authorDecember 20, 2021 Excuse me, can pictures of the appearance of the machine be provided?
-
Tarek hammoud December 26, 2021 I have pv1800 3kw. Could i get modbus protocol for rs485? To commmunicate hybrid solar inverter with plc. Thanks
-
Tarek hammoud December 26, 2021 I have pv1800 3kw. Could i get modbus protocol for rs485? To commmunicate hybrid solar inverter with plc. Thanks
-
enmustee Post authorJanuary 24, 2022 Hello, we will contact you by email!
-
enmustee Post authorJanuary 24, 2022 Hi, Tarek
Yes sure, pls email to info@mustpower.com
Thank you!
MUST
-
-
-
enmustee Post authorJanuary 24, 2022 Hi, Tarek
Yes sure, pls email to info@mustpower.com
Thank you!
MUST
-
-
-
Peter Schulze January 7, 2022 Good Day Must
Please assist me with the register mapping for the RS485/Can bus registers for the PV-5000.
Thank you very much
Peter Schulze-
enmustee Post authorJanuary 24, 2022 Hello, we will contact you by email!
-
-
enmustee Post authorJanuary 24, 2022 Hello, we will contact you by email!
-
-
metin Çoban January 31, 2022 Please send us a user manual in Turkish for MD:PC18-8015F
-
enmustee Post authorFebruary 8, 2022 by: https://drive.google.com/file/d/1_MUhkM6cSF93AVka8p1v369TG8O_t2t5/view?usp=sharing
-
-
enmustee Post authorFebruary 8, 2022 by: https://drive.google.com/file/d/1_MUhkM6cSF93AVka8p1v369TG8O_t2t5/view?usp=sharing
-
-
Roy February 14, 2022 Plz send manual for ups EH5003 3kva in english
-
enmustee Post authorFebruary 16, 2022 https://drive.google.com/file/d/1UYTh_8WsJnQSmHP8SSluzDpduP9xlYf1/view
OR
https://drive.google.com/file/d/1ZbES2TNdItmAz5dO5xdMu4I_WEypozJl/view
-
-
enmustee Post authorFebruary 16, 2022 https://drive.google.com/file/d/1UYTh_8WsJnQSmHP8SSluzDpduP9xlYf1/view
OR
https://drive.google.com/file/d/1ZbES2TNdItmAz5dO5xdMu4I_WEypozJl/view
-
-
pil sun-choi March 14, 2022 The manual’s documents are composed of photo files. I need a document file to understand the product.
I have to use a translator.
Even if it’s important, please prepare a document file and send it to me.
You don’t need a document file composed of pictures.
I have to use a translator.
Don’t you have the original document file?
I don’t understand.
I need the original at least how to set it up.
And what’s the setup mode for charging iron phosphate batteries?-
enmustee Post authorMarch 23, 2022 which model do you need?
-
-
enmustee Post authorMarch 23, 2022 which model do you need?
-
-
Vili March 22, 2022 Please send me Installation & Operation Manual for PV18-3024VPM and PV18-3024VHM Solar Inverter.
Thank you
-
enmustee Post authorMarch 23, 2022 https://drive.google.com/file/d/1NIE6cWQhSPSJGCtxcDLBdj0HJw6kWx3X/view
https://drive.google.com/file/d/143nbQ-FZmsw5mxHhuvEzrfZUNTYjVCuG/view
-
-
enmustee Post authorMarch 23, 2022 https://drive.google.com/file/d/1NIE6cWQhSPSJGCtxcDLBdj0HJw6kWx3X/view
https://drive.google.com/file/d/143nbQ-FZmsw5mxHhuvEzrfZUNTYjVCuG/view
-
-
amith September 5, 2022 i need user manual of pv18-5248 pro
-
enmustee Post authorSeptember 6, 2022 hello, link:https://en.must-ee.com/DL/PV1800,3-5.2KW,PRO,EN,MUST,BMS,JC.pdf
-
-
enmustee Post authorSeptember 6, 2022 hello, link:https://en.must-ee.com/DL/PV1800,3-5.2KW,PRO,EN,MUST,BMS,JC.pdf
I have bought Must Solar Inverter/Charger (with Inbuilt charge controller), 3 kW, 24 Volt, I have 10 universal batteries with 200 AH each (12v). I have issues in selecting the battery type selector . Any help…It will be better if I get a video tutorial installing the inverter/charger set????
-
enmustee Post authorSeptember 21, 2022 hello,
https://www.youtube.com/watch?v=cUiXnbnJeBc&list=PLgSOsncQj95XHtVaSdsJa2DyiyOIZK9F-
Leave a Reply
-
Contents
-
Table of Contents
-
Troubleshooting
-
Bookmarks
Quick Links
Related Manuals for Must Power PV18 Series
Summary of Contents for Must Power PV18 Series
-
Page 1
2KW-3KW… -
Page 3: Table Of Contents
Table Of Contents ABOUT THIS MANUAL ………………Purpose ………………….Scope ………………….SAFETY INSTRUCTIONS………………INTRODUCTION………………..Features ………………….Basic System Architecture ……………… Product Overview ………………… INSTALLATION………………..Unpacking and Inspection …………….. Preparation ………………..Mounting the Unit ……………….. Battery Connection ………………. AC Input/Output Connection …………….
-
Page 4: About This Manual
ABOUT THIS MANUAL Purpose This manual describes the assembly, installation, operation and troubleshooting of this unit. Please read this manual carefully before installations and operations. Keep this manual for future reference. Scope This manual provides safety and installation guidelines as well as information on tools and wiring. The following cases are not within the scope of warranty: (1) Out of warranty.
-
Page 5: Introduction
INTRODUCTION This is a multi-function inverter/charger, combining functions of inverter, solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-congurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications. Features Pure sine wave inverter Congurable input voltage range for home appliances and personal computers via LCD setting…
-
Page 6: Product Overview
Product Overview 1. LCD display 2. Status indicator 3. Charging indicator 4. Fault indicator 5. Function buttons 6. Power on/off switch 7. AC input 8. AC output 9. PV input 10. Battery input 11. Circuit breaker 12. RS-485 communication port 13.
-
Page 7: Installation
INSTALLATION Unpacking and Inspection Before installation, please inspect the unit. Be sure that nothing inside the package is damaged. You should have received the following items inside of package: The unit x 1 User manual x 1 Communication cable x 1 USB cable x 1 Software CD X 1 Preparation…
-
Page 8: Battery Connection
Install the unit by screwing three screws. 2~3KW Battery Connection CAUTION: To safety operation and regulation compliance, it’s requested to install a separate DC over-current protector or disconnect device between battery and inverter. It may not be requested to have a disconnect device in some applications, however, it’s still requested to have over-current protection installed.
-
Page 9: Ac Input/Output Connection
3. Insert the ring terminal of battery cable atly into battery connector of inverter and make sure the bolts are tightened with torque of 2-3 Nm. Make sure polarity at both the battery and the inverter/charge is correctly connected and ring terminals are tightly screwed to the battery terminals.
-
Page 10: Pv Connection
→Ground (yellow-green) L→LINE (brown or black) N→Neutral (blue) WARNING: Be sure to that AC power source is disconnected before attempting to hardwire it to the unit. 4. Then, insert AC output wires according to polarities indicated on terminal block and tighten terminal screws.
-
Page 11
Torque Value Typical Amperage Typical Amperage Cable Size 8AWG 1.4~1.6Nm 2KW~3KW 6AWG 2.0~2.4Nm PV Module Selection: When selecting proper PV modules, please be sure to consider below requirements rst: 1. Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter. 2. -
Page 12: Final Assembly
Solar panel installation schematic MPPT-60A MPPT-80A Final Assembly After connecting all wirings, please put bottom cover back by screwing two screws as shown below.
-
Page 13: Communication Connection
Communication Connection Please use supplied communication cable to connect to inverter and PC. Insert bundled CD into a computer and follow on-screen instruction to install the monitoring software. For the detailed software operation, please check user manual of software inside of CD. WARNING: It’s forbidden to use network cable as the communication cable to directly communicate with the PC port.
-
Page 14: Operation
OPERATION Power ON/OFF Once the unit has been properly installed and the batteries are connected well, simply press On/Off switch (located on the button of the case) to turn on the unit. Operation and Display Panel The operation and display panel, shown in below chart, is on the front panel of the inverter. It includes three indicators, four function keys and a LCD display, indicating the operating status and input/output power information.
-
Page 15: Lcd Display Icons
LCD Display Icons Icon Function description Input Source Information and Output Information Indicates the AC information. Indicates the DC information. Indicate input voltage, input frequency, PV voltage, battery voltage and charger current. Indicate output voltage, output frequency, load in VA, load in Watt and discharging current.
-
Page 16
In battery mode, it will present battery capacity. Load Percentage Battery Voltage LCD Display < 1.717V/cell 1.717V/cell ~ 1.8V/cell Load >50% 1.8 ~ 1.883V/cell > 1.883 V/cell < 1.817V/cell 1.817V/cell ~ 1.9V/cell 50%> Load > 20% 1.9 ~ 1.983V/cell > 1.983V/cell <… -
Page 17: Lcd Setting
LCD Setting After pressing and holding «ENTER» button for 2 seconds, the unit will enter setting mode, and then, press «ENTER» or «MENU» button to conrm the selection and exit. Press «UP» or «DOWN» button to select setting programs. Setting Programs: Program Description Selectable option…
-
Page 18
If selected, acceptable AC input Appliances (default) voltage range will be within 90- 280VAC. If selected, acceptable AC input voltage range will be within AC input voltage range 170-280VAC. If selected, acceptable AC input voltage range will conform to VDE4105(184VAC-253VAC) When the user uses the device to connect the generator, select the generator mode. -
Page 19
Solar and Utility Solar energy and utility will (default) charge battery at the same time. Only Solar Solar energy will be the only charger source no matter utility is available or not. If this inverter/charger is working in Battery mode or Power saving mode, only solar energy can charge battery. -
Page 20
Low DC cut off battery voltage setting If «User-Dened» LI is selected in program 14, this program can be set up. Setting range is from 20.0V to 24.0V for 24Vdc model. Increment of each click is 0.1V. Low DC cut-off voltage will be xed to setting value no matter what percentage of load is connected. -
Page 21: Fault Reference Code
Fault Reference Code Fault Code Fault Event Icon on Fan is locked when inverter is off Inverter transformer over temperature battery voltage is too high battery voltage is too low Output short circuited Inverter output voltage is high Overload time out Inverter bus voltage is too high Bus soft start failed Main relay failed…
-
Page 22: Warning Indicator
Inverter grid under frequency Inverter grid over frequency Inverter over current protection error Inverter bus voltage is too low Inverter soft start failed Over DC voltage in AC output Battery connection is open Inverter control current sensor error Inverter output voltage is too low Warning Indicator Icon on Fault Code…
-
Page 23: Operating Mode Description
Operating State Description Operation state Description LCD display PV is on PV energy is charger Utility-Tie state into the battery and utility provide power to the AC load. PV is off Charge state PV energy and grid can charge batteries. Bypass state Error are caused by inside circuit error or…
-
Page 24: Display Setting
Display Setting The LCD display information will be switched in turns by pressing «UP» or «DOWN» key. The selectable information is switched as below order: battery voltage, battery current ,inverter voltage, inverter current, grid voltage, grid current, load in Watt, load in VA, grid frequency, inverter frequency, PV voltage, PV charging power, PV charging output voltage, PV charging current.
-
Page 25: Specifications
SPECIFICATIONS Table 1 Line Mode Specications INVERTER MODEL Input Voltage Waveform Sinusoidal (utility or generator) Nominal Input Voltage 230Vac 90Vac±7V(APL,GEN); 170Vac±7V(UPS) Low Loss Voltage 186Vac±7V(VDE) 100Vac±7V(APL,GEN);180Vac±7V(UPS) Low Loss Return Voltage 196Vac±7V(VDE) 280Vac±7V(APL, UPS,GEN) High Loss Voltage 253Vac±7V(VDE) 270Vac±7V(APL,UPS,GEN) High Loss Return Voltage 250Vac±7V(VDE) Max AC Input Voltage 300Vac…
-
Page 26: Table 2 Inverter Mode SpeciCations
Table 2 Inverter Mode Specications INVERTER MODEL Rated Output Power 2KW/2000W 3KW/3000W Output Voltage Waveform Pure Sine Wave Output Voltage Regulation 230Vac±5% Output Frequency 60Hz or 50Hz Peak Efciency 5s@≥150% load; 10s@110%~150% load Overload Protection Nominal DC Input Voltage 24Vdc Cold Start Voltage 23.0Vdc Low DC Warning Voltage…
-
Page 27: Table 3 Charge Mode SpeciCations
Table 3 Charge Mode Specications Utility Charging Mode INVERTER MODEL Charging Current 20/30A @Nominal Input Voltage AGM / Gel/LEAD 25Vdc Absorption Battery Voltage Flooded Battery 25Vdc AGM / Gel/LEAD 27.4Vdc Reoat Battery Voltage Flooded Battery 27.4Vdc AGM / Gel/LEAD 28.8Vdc Float Battery Voltage…
-
Page 28: Table 4 General SpeciCations
Charging algorithm for Lithium battery Joint Utility and Solar Charging 2KW/3KW INVERTER MODEL MPPT-60A MPPT-80A CHARGER MODEL Max Charging Current Default Charging Current Table 4 General Specications INVERTER MODEL Safety Certication Operating Temperature Range 0°C to 50°C Storage temperature -15°C~ 60°C Dimension (D*W*H), mm 290 x 396 x 108 Net Weight, kg…
-
Page 29: Trouble Shooting
TROUBLE SHOOTING Explanation/Possible cause What to do LCD/LED/Buzzer Problem Unit shuts down LCD/LEDs and buzzer automatically will be active for 3 The battery voltage is too low. 1. Re-charge battery. during startup seconds and then (<1.91V/Cell) 2. Replace battery. process. complete off.
-
Page 30: Appendix: Approximate Back-Up Time Table
Appendix: Approximate Back-up Time Table Load (W) Backup Time @ 24Vdc 100Ah (min) Backup Time @ 24Vdc 200Ah (min) Model 1610 1000 1200 1400 1600 1800 2000 1100 1200 1500 1800 2100 2400 2700 3000 Note: Backup time depends on the quality of the battery, age of battery and type of battery. Specications of batteries may vary depending on different manufacturers.
-
Page 32
SOLAR INVERTER/CHARGER 420-00343-00…
In stock
Инвертор MUST PV18-1012 VPK для систем резервного и автономного электроснабжения мощностью 1 кВт и коэффициентом преобразования 1.0, представляет собой многофункциональное устройство, которое сочетает в себе солнечный контроллер заряда, инвертор , и зарядное устройство (ЗУ) для зарядки АКБ от сети 220В .
-
Описание
-
Детали
-
Отзывы (0)
Описание
Описание
Сферы применения:
- солнечные электростанции;
- источники бесперебойного питания;
- автономное и резервное электроснабжение;
Инвертор MUST PV18-1012 VPK для систем резервного и автономного электроснабжения мощностью 1 кВт и коэффициентом преобразования 1.0, представляет собой многофункциональное устройство, которое сочетает в себе солнечный контроллер заряда, инвертор , и зарядное устройство (ЗУ) для зарядки АКБ от сети 220В .Батарейный инвертор MUST PV18-1012 VPK накапливает энергию от солнечных модулей , сети или генератора в аккумуляторные батареи. Приоритеты зарядки АКБ и подачи электроэнергии потребителям задаются настройками инвертора. Таким образом, обеспечивается бесперебойная подача электроэнергии к потребителям. Батарейные инверторы MUST PV18-1012 VPK отлично подходят для загородных домов и крупных офисных помещений. Ими можно защищать компьютеры, серверы, котлы отопления. Это недорогие многофункциональные устройства, на которые можно положиться в критической обстановке.
Особенности инвертора MUST PV18-1012 VPK :
- Чистая синусоида на выходе инвертора
- Несколько режимов работы: параллельно с сетью, автономно, параллельно с сетью в режиме резервного источника питания;
- Автоматический перезапуск при восстановлении питания переменного тока ;
- Большой жидкокристаллический дисплей отображает всю основную информацию о работе системы солнечного электроснабжения ;
- Возможности для соединения с компьютером для настройки и мониторинга работы системы электроснабжения ;
- Настройка нижнего и верхнего порога зарядки аккумуляторов ;
- Настраиваемый диапазон входного напряжения для домашней техники или ПК ;
- Настраиваемый ток заряда аккумуляторов ;
- 3-х ступенчатый режим заряда АКБ ;
- Защита от перегрузки / перегрева / короткого замыкания ;
- Эффективная конструкция зарядного устройства для оптимизации производительности аккумулятора.
Детали
Детали
Модель |
MUST PV18-1012 VPK |
---|---|
Номинальная мощность |
1000ВА / 1000Вт |
Выбор диапазона входных напряжений |
170-280 В (для компьютерной техники) |
Частотный диапазон |
50 Нг/60 Гц (автовыбор) |
Регулирование напряжение переменного тока |
230 В ± 5% |
Пиковая мощность |
2000 ВА |
Эффективность |
93% |
Время переключения |
10 мс (для компьютерной техники); 20 мс (для домашней бытовой техники) |
Форма выходного сигнала |
чистый синус |
Номинальное напряжение |
12 В |
Напряжение поддержания заряда |
13.5 В |
Защита от перегрузки |
15.5 В |
Тип солнечного контроллера |
PWM |
Максимальное напряжение холостого хода солнечных панелей |
55 В |
Максимальный ток заряда от солнечной панели |
50 А |
Максимальный ток заряда от электросети |
10/20 А |
Общий максимальный ток заряда |
70 А |
Порт соединения |
USB/RS-485 |
Отзывы (0)
MUST PV1800 VPM Series High Frequency Home Solar Inverter
This is a multi-function inverter/charger, combining functions of inverter, MPPT50A/80A solar charger and battery charger to offer uninterruptible power support with portable size. Its comprehensive LCD display offers user-configurable and easy-accessible button operation such as battery charging current, AC/solar charger priority, and acceptable input voltage based on different applications.
Features:
-
Rated power 1KW to 5KW
-
Pure sine wave output
-
Smart LCD setting (Working modes, Charge Current, Charge Voltage, etc).
-
Bult in MPPT50A/80A solar charge controller
-
Combining solar system, AC utility, and battery power source to supply continuous power
-
Overload, short circuit and Deep discharge protection
-
Cold start function
-
Support USB, RS485 monitoring function with free CD
-
WIFI remote monitoring (optional)
-
Compatible to generator
-
3KW-5KW support parallel function(optional)
Note:Dear Due to the upgrade of product appearance, the product you purchased is a new appearance, function exactly the same,please understand
MODEL |
PV18-1012 VPM |
PV18-2024 VPM |
PV18-3024 VPM |
PV18-3048 VPM |
PV18-4048 VPM |
PV18-5048 VPM |
Default Battery System Voltage |
12VDC |
24VDC |
48VDC |
|||
INVERTER OUTPUT |
||||||
Rated Power |
1000VA / 1000W |
2000VA / 2000W |
3000VA / 3000W |
3000VA / 3000W |
4000VA / 4000W |
5000VA / 5000W |
Surge Power |
2000VA |
4000VA |
6000VA |
6000VA |
8000VA |
10000VA |
Waveform |
Pure sine wave |
|||||
AC Voltage Regulation (Batt.Mode) |
220VAC~240VAC(Setting) |
|||||
Inverter Efficiency(Peak) |
90%~93% |
|||||
Transfer Time |
10ms(UPS / VDE4105) / 20ms(APL) |
|||||
AC INPUT |
||||||
Voltage |
230VAC |
|||||
Selectable Voltage Range |
170~280VAC(UPS) / 90~280VAC(APL) / 184~253VAC(VDE) |
|||||
Frequency Range |
50Hz / 60Hz (Auto sensing) |
|||||
BATTERY |
||||||
Normal voltage |
12VDC |
24VDC |
48VDC |
|||
Floating Charge Voltage |
13.7VDC |
27.4VDC |
54.8VDC |
|||
Overcharge Protection |
15VDC |
30VDC |
60VDC |
|||
SOLAR CHARGER & AC CHARGER |
||||||
Maximum PV Array Open Circuit Voltage |
105VDC |
145VDC |
145VDC |
|||
PV Array MPPT Voltage Range |
15~105VDC |
30~120VDC |
60~130VDC |
|||
Standby Power Consumption |
2W |
|||||
Maximum PV Array Power |
720W |
1500W |
4000W |
|||
Maximum Solar Charge Current |
60A |
80A |
||||
Maximum Efficiency |
98% |
|||||
Maximum AC Charge Current |
10A or 20A |
20A or 30A |
60A |
|||
Maximum Charge Current |
70A |
80A |
140A |
|||
MECHANICAL SPECIFICATIONS |
||||||
Machine Dimensions (W*H*D)(mm) |
225*355*92 |
272*355*100 |
297.5*468*125 |
|||
Package Dimensions (W*H*D)(mm) |
410*300*78 |
485*393*251 |
638*395*241 |
|||
Net Weight(kg) |
5 |
7.4 |
14 |
|||
Gross Weight(kg) |
5.5 |
9.5 |
16.4 |
|||
OTHER |
||||||
Humidity |
5% to 95% Relativ Humidity (Non-condensing) |
|||||
Operating Temperature |
0°C~50°C |
|||||
Storage Temperature |
-15°C -60°C |
FAQ
1. How to choose an inverter that suits you?
Please confirm your loads, battery capacity and voltage, solar panel string capacity; you can contact us for professional help
2. Who we are?
We are a MUST source manufacturer, selling original MUST products
3. What Is an Inverter Charger with MPPT?
It is an Integrated unit wit MPPT solar charge controller, pure sine wave inverter, and battery charger in one compact unit to let you enjoy the stable power from the sun and the utility grid to keep you powered under any circumstances. PV1800 VPM 3KW Solar Inverter Charger combines solar charging, AC/generator battery charging, and battery inverting into one convenient solution to take your off-grid system to the hybrid level.
4. Can I use this inverter to charge my batteries?
Yes. Compatible with 24V battery banks, this solar inverter charger keeps your battery charged with solar panels and AC/generator.
5. Can I use the inverter with a 48V system?
No. This model can only work with 24V battery system.
6. How many solar panels can I connect to this inverter?
For example Vmp 30.9Vdc, Imp 8.42A, Voc 37.7Vdc, Isc 8.89A 250W solar panel, you can connect 9pcs of it to our inverter, 3S3P
7. How do I hook up the Inverter? What size cable should I use, and is it included?
When connecting the inverter to the battery and solar panels, please read all of the instructions and cautions in the manual before beginning the installation. The minimum recommended wiring gauge for battery wiring is 4AWG(for a 100AH battery) 6AWG(for a 200AH battery), PV wiring is 8AWG, AC input and out wiring is 12AWG.
Incorrect or improper connection points and corroded wires can cause great heat to melt the wire insulation, burning surrounding materials, and even cause fire, so ensure that the connection is tightened
8. Can I use the solar inverter without batteries when using PV or Mains?
No, at minimum you need to have batteries connected to the unit.But our PV1800/PH1800 PRO series can run without battery. You can have a look at our store
9. Does this solar inverter limit PV current? I’m not getting my full power?
When setting up the solar inverter, ensure Program 11 (PV Charging Current) and Program 13 (Maximum Charge Current) are set to their maximum to ensure no PV current clipping.
10. Can I use theWIFI Module to monitor the inverter from my phone? Which WIFI Module should I buy?
Yes. The WIFI-PLUG is compatible with this inverter.Please choose your inverter with WIFI-PLUG to order
11. Warranty Policy
The MUST products we sell are covered by a one-year warranty. In case of product failure, contact our after-sales engineers for help in the first instance. If necessary, we will send you free parts (within the warranty period).
Wrong way of operation may cause the product to burn out, such as not following the standard installation when connecting cables. Please read the manual carefully when installing.
12. Shipping Policy
Normally we send the goods the second days after payments. We use air cargo to send the goods. Aliexpress Standard Shipping arrive at 15-20days(EU country arrive at 7-10 days), DHL/FedEx/UPS arrive at 7-10 days, Cainiao Heavy Line arrive at 20 days(EU 15-20 Days).
MODEL |
PV18-1012 VPM |
Default Battery System Voltage |
12VDC |
INVERTER OUTPUT |
|
Rated Power |
1000VA/1000W |
Surge Power |
2000VA |
Waveform |
Pure sine wave |
AC Voltage Regulation (Batt.Mode) |
220VAC ~ 240VAC (Setiing) |
Inverter Efficiency (Peak) |
90%~93% |
Transfer Time |
10ms(For Personal Computers)20ms(For Home Appliance) |
AC INPUT |
|
Voltage |
230VAC |
Selectable Voltage Range |
170~280VAC(For Personal Computers)、90~280VAC(For Home Appliances)、184~253VAC(VDE) |
Frequency Range |
50Hz/60Hz (Auto sensing) |
BATTERY |
|
Normal voltage |
12VDC |
Floating Charge Voltage |
13.7VDC |
Overcharge Protection |
150VDC |
SOLAR CHARGER&AC CHARGER |
|
Maximum PV Array Open Circuit Voltage |
60VDC |
PV Array MPPT Voltage Range |
15~60VDC |
Standby Power Consumption |
2W |
Maximum PV Array Power |
625W |
Maximum Solar Charge Current |
50A |
Maximum Efficiency |
98% |
Maximum AC Charge Current |
10A or 20A |
Maximum Charge Current |
70A |
MECHANICAL SPECIFICATIONS |
|
Machine Dimensions (W*H*D)(mm) |
272*355*100 |
Package Dimensions (W*H*D)(mm) |
485*393*251 |
Net Weight(kg) |
7.4 |
Gross Weight(kg) |
9.5 |
OTHER |
|
Humidity |
5% to 95% Relative Humidity (Non-condensing) |
Operating Temperature |
0°C -55°C |
Storage Temperature |
-15°C -60°C |
https://en.must-ee.com/
FAQ
Q:How to choose an inverter that suits you?
A:Please confirm your loads, battery capacity and voltage, solar panel string capacity; you can contact us for professional help
Q:Who we are?
A:We are a MUST source manufacturer, selling original MUST products
Q:What Is an Inverter Charger with MPPT?
A:It is an Integrated unit wit MPPT solar charge controller, pure sine wave inverter, and battery charger in one compact unit to let you enjoy the stable power from the sun and the utility grid to keep you powered under any circumstances. PV1800 VPM 1KW Solar Inverter Charger combines solar charging, AC/generator battery charging, and battery inverting into one convenient solution to take your off-grid system to the hybrid level.
Q:Can I use this inverter to charge my batteries?
A:Yes. Compatible with 12V battery banks, this solar inverter charger keeps your battery charged with solar panels and AC/generator.
Q:Can I use the inverter with a 48V system?
A:No. This model can only work with 12V battery system.
Q:How many solar panels can I connect to this inverter?
A:For example Vmp 30.9Vdc, Imp 8.42A, Voc 37.7Vdc, Isc 8.89A 250W solar panel, you can connect 9pcs of it to our inverter, 3S3P
Q:How do I hook up the Inverter? What size cable should I use, and is it included?
A:When connecting the inverter to the battery and solar panels, please read all of the instructions and cautions in the manual before beginning the installation. The minimum recommended wiring gauge for battery wiring is 4AWG(for a 100AH battery) 6AWG(for a 200AH battery), PV wiring is 8AWG, AC input and out wiring is 12AWG.
Incorrect or improper connection points and corroded wires can cause great heat to melt the wire insulation, burning surrounding materials, and even cause fire, so ensure that the connection is tightened
Q:Can I use the solar inverter without batteries when using PV or Mains?
A:No, at minimum you need to have batteries connected to the unit. But our PV1800/PH1800 PRO series can run without battery. You can have a look at our store
Q:Does this solar inverter limit PV current? I’m not getting my full power?
A:When setting up the solar inverter, ensure Program 11 (PV Charging Current) and Program 13 (Maximum Charge Current) are set to their maximum to ensure no PV current clipping.
Q:Can I use the WIFI Module to monitor the inverter from my phone? Which WIFI Module should I buy?
A:Yes. The WIFI-PLUG is compatible with this inverter. Please choose your inverter with WIFI-PLUG to order
Q:Warranty Policy
A:The MUST products we sell are covered by a one-year warranty. In case of product failure, contact our after-sales engineers for help in the first instance. If necessary, we will send you free parts (within the warranty period).
Wrong way of operation may cause the product to burn out, such as not following the standard installation when connecting cables. Please read the manual carefully when installing.
Q:Shipping Policy
A:Normally we send the goods the second days after payments. We use air cargo to send the goods. Aliexpress Standard Shipping arrive at 15-20days(EU country arrive at 7-10 days), DHL/FedEx/UPS arrive at 7-10 days, Cainiao Heavy Line arrive at 20 days(EU 15-20 Days).
Автономный/Батарейный инвертор Combi-M PV18-1012VPK для систем резервного и автономного электроснабжения мощностью 1 кВт и коэффициентом преобразования 1.0, представляет собой многофункциональное устройство, которое сочетает в себе солнечный контроллер заряда, инвертор и зарядное устройство (ЗУ) для зарядки АКБ от сети 220В. Батарейный инвертор PV18-1012 VPK накапливает энергию от солнечных модулей или сети в аккумуляторные батареи. Приоритеты зарядки АКБ и подачи электроэнергии потребителям задаются настройками инвертора. Таким образом, обеспечивается бесперебойная подача электроэнергии к потребителям.
ЖК-дисплей позволяет настраивать пользователю настраивать различные параметры работы, например, ток зарядки аккумулятора, приоритет зарядного устройства переменного / солнечного питания, допустимое входное напряжение, и другое.
Батарейные инверторы PV18-1012 VPK отлично подходят для загородных домов и крупных офисных помещений. Ими можно защищать компьютеры, серверы, котлы отопления. Это недорогие многофункциональные устройства, на которые можно положиться в критической обстановке.
Сферы применения инвертора PV18-1012 VPK:
- солнечные электростанции;
- источники бесперебойного питания;
- источники резервного электропитания;
- другие области применения.
Особенности инвертора PV18-1012 VPK :
- Чистая синусоида на выходе инвертора
- Несколько режимов работы: параллельно с сетью, автономно, параллельно с сетью в режиме резервного источника питания;
- Автоматический перезапуск при востановлении питания переменного тока ;
- Большой жидкокристаллический дисплей отображает всю основную информацию о работе системы солнечного электроснабжения ;
- Возможности для соединения с компьютером для настройки и мониторинга работы системы электроснабжения ;
- Настройка нижнего и верхнего парога зарядки аккумуляторов ;
- Настраиваемый диапазон входного напряжения для домашней техники или ПК ;
- Настраиваемый ток заряда аккумуляторов ;
- 3-х ступенчатый режим заряда АКБ ;
- Защита от перегрузки / перегрева / короткого замыкания ;
- Эффективная конструкция зарядного устройства для оптимизации производительности аккумулятора.
Технические характеристики
Модель | PV18-1012 VPK |
---|---|
Номинальная мощность | 1000ВА / 1000Вт |
DC ВХОД | |
Номинальное напряжение | 230 В |
Выбор диапазона входных напряжений | 170-280 В (для компьютерной техники) 90-280 В (для бытовой техники) |
Частотный диапазон | 50 Нг/60 Гц (автовыбор) |
AC ВЫХОД | |
Регулирование напряжение переменного тока | 230 В ± 5% |
Пиковая мощность | 2000 ВА |
Эффективность | 90% ~ 93% |
Время переключения | 10 мс (для компьютерной техники); 20 мс (для домашней бытовой техники) |
Форма выходного сигнала | чистый синус |
АКБ | |
Номинальное напряжение | 12 В |
Напряжение поддержания заряда | 13.5 В |
Защита от перегрузки | 15.5 В |
ЗАРЯД ОТ СОЛНЕЧНЫХ БАТАРЕЙ И ЭЛЕКТРОСЕТИ | |
Тип солнечного контроллера | PWM |
Максимальное напряжение холостого хода солнечных панелей | 55 В |
Максимальный ток заряда от солнечной панели | 50 А |
Максимальный ток заряда от электросети | 10/20 А |
Общий максимальный ток заряда | 70 А |
ГАБАРИТЫ | |
Глубина х Ширина х Длина (мм) | 92 х 225 х 355 |
Вес (кг) | 4 |
Порт соединения | USB/RS-485 |
УСЛОВИЯ ХРАНЕНИЯ И ЭКСПЛУАТАЦИИ | |
Влажность | 5%…95% относительной влажности (без конденсата) |
Рабочая температура | 0°С до 55°С |
Температура хранения | -15°С до 60°С |
Этот ББП также продается под названиями: Hiden Control HS20-1012P
См. также соответствие оригинальных моделей производителя торговым названиям импортеров в РФ
Электрические параметры | |
Напряжение СБ макс., В | 55 |
Напряжение DC, В | 12 |
Пиковая мощность, Pном* | 2 |
Мощность, кВт/кВА | 1 |
Ток заряда АБ, А | 70 |
Свойства | |
Панель индикации | встроенная |
Тип инвертора | In-line (резервный) |
Функции | |
Подключение ФСИ к выходу | нет |
Встроенный солнечный контроллер | PWM (ШИМ) |
Приоритет для АБ/СБ | Переключение |
3 фазы | нет |
Выходы параллельно | нет |
«Сухие» контакты | 1 |