Contents
-
Table of Contents
-
Bookmarks
Quick Links
Nice
made in Italy
OXIBD
OXIBD/A
Radio receiver
EN — Instructions and warnings for installation and use
Related Manuals for Nice OXIBD
Summary of Contents for Nice OXIBD
-
Page 1
Nice made in Italy OXIBD OXIBD/A Radio receiver EN — Instructions and warnings for installation and use… -
Page 2: Product Description
Instructions translated from Italian PRODUCT DESCRIPTION OXIBD (OXIBD/A) is a radio receiver designed for being installed on a control unit for automating gates, garage doors and road barriers. – All uses other than the intended use described and use in environmental conditions other than those described in this manual should be considered improper and forbidden! •…
-
Page 3
• Other product characteristics – The OXIBD receiver is compatible with the “O-Code”, “FloR”, “TTS”, “Smilo” and “Flo” one-way radio encod- ing systems, and with the “BD” two-way encoding system. In particular, the “O-Code” and “BD” encoding systems allow for exploiting all the advanced and exclusive functions of the “NiceOpera” system. -
Page 4: Installation And Connection
INSTALLATION AND CONNECTION The receiver must be connected to the control unit by inserting it through the relevant slot: Before inserting (or removing) the receiver, disconnect the power supply to the control unit. Connect the antenna supplied to terminal 1 of the re- ceiver, as shown in Fig.
-
Page 5
Restore the power supply to the control unit. MEMORISING / DELETING TRANSMITTERS IN THE RECEIVER The first one-way transmitter to be memorised in the receiver also defines the encoding system (“O-Code” (“O-Code/A”) or “FloR” or “TTS” or “Smilo” or “Flo”) that each successive one-way transmitter to be memorised must have. -
Page 6
• 2 green flashes = transmitters with O-Code (O-Code/A) or FloR or TTS encoding system • 2 green flashes and 1 orange flash = transmitters with O-Code x 2+1 (O-Code/A) or FloR or TTS + BD encoding system • 3 green flashes = transmitters with Smilo encoding system • 3 green flashes and 1 orange flash = transmitters with Smilo + x 3+1 BD encoding system • 5 green flashes = no transmitter memorised… -
Page 7
KEY TO THE SYMBOLS USED IN THE MANUAL Symbol Description (on the receiver) LED “B” STEADY LIT (on the receiver) LED “B” LONG FLASH (on the receiver) LED “B” QUICK FLASH (on the receiver) LED “B” OFF Disconnect power supply / Restore power supply Wait … -
Page 8
Press and release key “A” of the receiver Release key “A” of the receiver Press and release the desired transmitter key Hold down the desired transmitter key Release the desired transmitter key Read the control unit’s instruction manual … Observe when LED “B” emits signals The system can be programmed in Mode 1 or in Mode 2: see Paragraphs 3.1 and 3.2. -
Page 9
procedure terminates, the memorisation will occupy a single memory location and the command associated with each key will depend on the “List of commands” present on the automation’s control unit. PROCEDURE 1 — Mode 1 memorisation On the receiver: hold down key A and wait for the green LED B to light up. -
Page 10
by the installer from the “List of commands” of the automation’s control unit. Note — A key can be associated with only one output, while the same output can be associated with multiple keys. PROCEDURE 2 — Mode 2 memorisation (and extended Mode 2) In the control unit manual: choose the command to be memo- rised and remember its “identification number”. -
Page 11
transmitter already memorised. The procedure does not entail any direct action on key A of the receiver, only the presence of the transmitter within the receiver’s reception range. • The memorisation “near the receiver” can be prevented by blocking the receiver’s function through Procedure 7 (Paragraph 3.8). -
Page 12
3.5 — Memorising (in the receiver) the control unit Series/Address, for the BusT4 network The OXIBD (OXIBD/A) receiver can interact with a single control unit through the “BusT4” network. If the system contains multiple control units connected to each other via “BusT4”, before carrying out the following procedure the cable of the “BusT4”… -
Page 13
“Memorising the control unit Series/Address for the BusT4 network” procedure. WARNING! — To ensure correct management of the status on two-way transmitters (ON3EBD (ON3EBD/A)), the OXIBD (OXIBD/A) receiver must have the same Series as the control unit. 3.6 — Deleting the receiver’s memory (fully or partially) In a one-way system, the memorisation or code deletion procedures involve the receiver alone. -
Page 14
With the memorisation of two-way transmitters in the OXIBD (OXIBD/A) receiver, the identification code of the same receiver is automatically memorised by the transmitter. Warning! — if the two-way transmitter in the OXIBD (OXIBD/A) receiver is deleted, to complete the operation it is necessary to also delete the transmitter’s memory. -
Page 15
3.7 — Deleting a SINGLE transmitter or a SINGLE key from the receiver memory PROCEDURE 6 — Deleting a SINGLE transmitter or a SINGLE key from the receiver memory On the receiver: hold down key A, observe the green LED B light up and move to step 02 when it switches off. -
Page 16
procedure (Paragraph 3.3) or the “enabling code” procedure (Paragraph 3.4). The default setting is ON for both procedures. To perform the following procedure it is necessary to have a transmitter already memorised in the receiver. PROCEDURE 7 — Locking (or release) of memorisations carried out with the “near the control unit”… -
Page 17: Other Functions
Within 5 seconds: repeatedly press and release key A of the > 5 sec < receiver to choose one of the following functions, identifiable by the status of LED B: — No lock active = LED OFF — Locking of the memorisation “near the control unit” = RED LED — Locking of the memorisation with the “enabling code”…
-
Page 18
When the transmitter is used for the first time, the receiver will memorise the new priority level received and ignore any command sent by the lost or stolen transmitter, should it be used. The priority can be changed through the O-Box programmer. By default the receiver has the “Priority”… -
Page 19: Technical Specifications
O-Box and O-View programmers, if the password is not known. TECHNICAL SPECIFICATIONS OXIBD Product type Two-way receiver Decoding OXIBD: “BD” / “O-code” / “FloR” / “TTS” / “Flo” / “Smilo” OXIBD/A: “BD” / “O-code/A” Input impedance 50 Ω Reception frequency 433.92 MHz Transmission frequency 433.92 MHz (only BD)
-
Page 20: Product Disposal
– All technical specifications stated herein refer to an ambient temperature of 20°C (± 5° C). – Nice reserves the right to apply modifications to the product at any time when deemed necessary, without altering the intended use and functions of the product itself.
-
Page 21
SIMPLIFIED EU DECLARATION OF CONFORMITY Hereby Nice S.p.A. declares that the radio equipment type OXIBD is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: https://www.niceforyou.com/en/support… -
Page 22
Signals emitted by LED B of the receiver Long flashes > GREEN On start-up: 1 Z = Current encoding system: “Flo” 2 Z = Current encoding system: “O-Code”/“FloR” 3 Z = Current encoding system: “Smilo” 5 Z = No remote control memorised During operation: 1 Z = Indicates that the code received is not stored in the memory 3 Z = Saving code in memory 5 Z = Memory deleted… -
Page 23
5 Z = During the deletion procedure, indicates that the code has been deleted 5 Z = “Certificate” with lower priority than the admissible level 6 Z = Code synchronisation failure Long flashes > RED 1 Z = Non-original code block 2 Z = Code with lower priority than the authorised level Short flashes > RED 1 Z = “In vicinity”… -
Page 24
Nice S.p.A. Via Callalta, 1 31046 Oderzo TV Italy www.niceforyou.com info@niceforyou.com…
This manual is also suitable for:
Oxibd/a
- Manuals
- Brands
- Nice Manuals
- Receiver
- OXIBD/A
Manuals and User Guides for Nice OXIBD/A. We have 2 Nice OXIBD/A manuals available for free PDF download: Instructions And Warnings For Installation And Use, Instructions For The Fitter
Nice OXIBD/A Instructions And Warnings For Installation And Use (24 pages)
Two-way receiver
Brand: Nice
|
Category: Receiver
|
Size: 5.32 MB
Table of Contents
-
Product Description
2
-
Installation and Connection
4
-
Other Functions
17
-
Technical Specifications
19
-
Product Disposal
20
Advertisement
Nice OXIBD/A Instructions For The Fitter (2 pages)
Brand: Nice
|
Category: Receiver
|
Size: 5.07 MB
Advertisement
Related Products
-
Nice OXI
-
Nice OXIBD
-
Nice OXILR
-
Nice OXILR/A
-
Nice NICEONE OX2 SERIES
-
Nice NiceOne OX4T
-
Nice NiceOne OX4
-
Nice NiceOne OX2FM
-
Nice NiceOne OX2T
-
Nice NiceOne OX2TFM
Nice Categories
Gate Opener
Engine
Control Unit
Garage Door Opener
Receiver
More Nice Manuals
Nice
OXIBD
OXIBD/A
Radio receiver
EN — Instructions and warnings for installation and use
made in Italy
EN
ENGLISH
Instructions translated from Italian
1 PRODUCT DESCRIPTION
OXIBD (OXIBD/A) is a radio receiver designed for being installed on a control unit for automating gates, garage doors and road barriers.
– All uses other than the intended use described and use in environmental conditions other than those described in this manual should be considered improper and forbidden!
• One-way and two-way radio communication
In one-way radio communication, the two devices involved (equipped with one-way radio technology) have a clearly defined and unambiguous role within the system: there is a transmitter that simply transmits and a receiver that only receives without any further role. The radio communication, therefore, is one-way.
Instead in two-way communication, the two devices (equipped with two-way radio technology) play a different role each time within the system, as each one is capable of receiving and transmitting information from/to another device. Therefore, even the transmitters can turn into “receivers” of information coming from the receiver mounted in the control unit.
The OXIBD (OXIBD/A) receiver has both the radio technologies, thus it can interface with both one-way and two-way transmitters.
Throughout this manual, “two-way” refers to the “two-way technology” of receiver-transmitter radio devices, while the term “BD” denotes a specific radio encoding protocol adopted by OXIBD (OXIBD/A) and by transmitters featuring this encoding protocol.
“BD” encoding, unlike the other one-way encoding systems compatible with OXIBD (OXIBD/A) (see further below), offers the following additional functions:
1 — English
– the sending of the confirmation (on the transmitter) that the transmitted command was received; |
EN |
|
– the sending of the status (on the transmitter) of the transmitter (for example, if the door, gate, etc., is open or |
||
closed). |
• Other product characteristics
–The OXIBD receiver is compatible with the “O-Code”, “FloR”, “TTS”, “Smilo” and “Flo” one-way radio encoding systems, and with the “BD” two-way encoding system. In particular, the “O-Code” and “BD” encoding systems allow for exploiting all the advanced and exclusive functions of the “NiceOpera” system.
–The OXIBD/A receiver is compatible with the “O-Code/A”, “FloR/A” one-way radio encoding systems, and with the “BD” two-way encoding system.
–The receiver, if it contains one-way transmitters only, can manage 1024 memory locations at the most: one location can alternatively memorise a single transmitter (if its keys are memorised as a “single set”, with the Mode 1 procedures – read Paragraph 3.1), or a single key (if memorised with the Mode 2 procedures – read Paragraph 3.2). If the receiver contains two-way transmitters only, a maximum of 750 two-way transmitters can be memorised.
–Each receiver has its own identification number, known as the “Certificate”. This allows for accessing several operations, such as, for example: the memorisation of new transmitters without having to access the receiver, and the use of the O-View programmer through its “BusT4” connection to the control unit.
–This receiver can be used solely with control units equipped with “SM”-type plug connector (verify the most suitable control units on the Nice product catalogue or on the www.niceforyou.com website).
–This receiver automatically recognises the characteristics of the control unit on which it is installed and selfsets in the following way:
—If the control unit manages the “BusT4”, the receiver makes available up to 15 different commands.
—If the control unit DOES NOT manage the “BusT4”, the receiver makes available up to 4 different commands. Important! – In both cases, the number and diversity of the available commands depend on the type and
model of the control unit adopted. The “Table of commands” of each control unit is shown in the respective instruction manual.
English — 2
EN
2 INSTALLATION AND CONNECTION
The receiver must be connected to the control unit by inserting it through the relevant slot:
01. |
Before inserting (or removing) the receiver, |
OFF |
||
disconnect the power supply to the control unit. |
||||
02. Connect the antenna supplied to terminal 1 of the re- |
||||
ceiver, as shown in Fig. A. Alternatively, if the radio |
||||
signal reception must be improved through the instal- |
2 |
|||
lation of an external antenna with a coaxial cable with |
1 |
|||
50Ω impedance (type RG58), the coaxial cable must |
2 |
1 |
||
be connected directly to terminals 1 and 2 of the |
Fig. A |
|||
receiver (Fig. B), ignoring the “antenna” terminal (if |
||||
present) on the control panel. |
03.Insert the receiver through the relevant opening on the control unit.
3 — English
04. |
Restore the power supply to the control unit. |
ON |
EN
3 MEMORISING / DELETING TRANSMITTERS IN THE RECEIVER
The first one-way transmitter to be memorised in the receiver also defines the encoding system (“O-Code” (“O-Code/A”) or “FloR” or “TTS” or “Smilo” or “Flo”) that each successive one-way transmitter to be memorised must have. Transmitters with “BD” encoding can instead be memorised freely, as they are compatible with oneway transmitters inside the receiver’s memory.
Each single coding allows for exploiting only the functions linked to that specific encoding system.
To verify to which encoding system the transmitters already memorised in the receiver belong, proceed as follows (Warning! – The receiver must already be connected to the control unit):
Verification of the TYPE OF ENCODING system adopted by the transmitters already memorised
01. Disconnect the power supply to the control unit and then restore |
OFF ON |
|
the power. |
||
LED B of the receiver will light up green first then orange. When the |
||
orange LED switches off, count the number of subsequent flashes: |
||
•1 green flash = transmitters with O-Code or FloR or TTS encod- |
x 1 |
|
ing system |
||
•1 green flash and 1 orange flash = transmitters with O-Code or |
x 1+1 |
|
FloR or TTS + BD encoding system |
||
English — 4
EN
•2 green flashes = transmitters with O-Code (O-Code/A) or FloR |
x 2 |
|
or TTS encoding system |
||
•2 green flashes and 1 orange flash = transmitters with O-Code |
x 2+1 |
|
(O-Code/A) or FloR or TTS + BD encoding system |
||
•3 green flashes = transmitters with Smilo encoding system |
x 3 |
•3 green flashes and 1 orange flash = transmitters with Smilo + |
x 3+1 |
|
BD encoding system |
||
•5 green flashes = no transmitter memorised |
x 5 |
•5 green flashes and 1 orange flash = transmitters with BD tech- |
x 5+1 |
|
nology |
||
To change the coding assigned to the first one-way transmitter memorised, it is necessary to delete from the memory all the transmitters present (one-way and two-way), by strictly adopting Procedure 5 (Paragraph 3.6) and choosing the option, “ALL THE RECEIVER MEMORY”.
WARNINGS for carrying out the programming procedures |
A |
B |
|
• During the execution of the programming procedures, refer to Fig. 1 to identify key |
|||
A and LED B on the receiver. • To understand the meaning of the icons featured in the |
|||
procedure, refer to the table, “Key to the symbols used in the manual”. • The proce- |
2 |
1 |
|
dures have a limit time; therefore, before implementing them, it is important to read and |
|||
understand all the steps to be completed. |
|||
1 |
5 — English
KEY TO THE SYMBOLS USED IN THE MANUAL |
||
Symbol |
Description |
|
(on the receiver) LED “B” STEADY LIT |
||
(on the receiver) LED “B” LONG FLASH |
||
(on the receiver) LED “B” QUICK FLASH |
||
(on the receiver) LED “B” OFF |
||
OFF |
ON |
|
Disconnect power supply / Restore power supply |
||
Wait … |
||
> 5 sec < |
Perform the operation within 5 seconds … |
|
Hold down key “A” of the receiver |
EN
English — 6
EN
Press and release key “A” of the receiver
Release key “A” of the receiver
Press and release the desired transmitter key
Hold down the desired transmitter key
Release the desired transmitter key
Read the control unit’s instruction manual
… Observe when LED “B” emits signals
The system can be programmed in Mode 1 or in Mode 2: see Paragraphs 3.1 and 3.2.
3.1 — Memorisation in “Mode 1”
While Procedure 1 is being carried out, the receiver memorises all the keys present on the transmitter, automatically assigning command 1 of the receiver to the 1st key, command 2 to the 2nd key, and so forth. Once the
7 — English
Loading…