Pac lv11m j инструкция по монтажу

Mitsubishi Electric City Multi PAC-LV11M-J Installation Manual

  • Contents

  • Table of Contents

  • Troubleshooting

  • Bookmarks

Quick Links

AIR CONDITIONING SYSTEMS

CONNECTION KIT

PAC-LV11M-J

INSTALLATION MANUAL

For safe and correct use, please read this installation manual thoroughly before installing the indoor unit.

loading

Related Manuals for Mitsubishi Electric City Multi PAC-LV11M-J

Summary of Contents for Mitsubishi Electric City Multi PAC-LV11M-J

  • Page 1
    AIR CONDITIONING SYSTEMS CONNECTION KIT PAC-LV11M-J INSTALLATION MANUAL For safe and correct use, please read this installation manual thoroughly before installing the indoor unit.
  • Page 2: Table Of Contents

    • Always use an air cleaner, humidifier, electric heater, and other acces- compressor trouble may result. sories specified by Mitsubishi Electric. • Use liquid refrigerant to fill the system. — Ask an authorized technician to install the accessories. Improper installation — If gas refrigerant is used to seal the system, the composition of the refriger- by the user may result in water leakage, electric shock, or fire.

  • Page 3: Before Getting Installed

    — If dust, dirt, or water gets in the refrigerant cycle, the refrigerant may deteri- • Do not touch the refrigerant pipes during and immediately after opera- orate. tion. — During and immediately after operation, the refrigerant pipes are may be hot 1.3.

  • Page 4: Overview Of Units

    2. Overview of units 2.1. System outline 2.1.1. System example Connection kit Connection kit Connection kit Connection kit Outdoor unit 2.2. Unit construction Outdoor unit Capacity Indoor unit that Number of units can be Refer to manuals of the outdoor unit. Total system wide connected capacity…

  • Page 5: Installation

    2.3. Installation 2.3.1. Installing the connection kit Parts to procure locally • Suspension bolts or anchor bolts : W3/8 (M10) • Nut : W3/8 (M10) • Washer : W3/8 (M10) Installing the unit in a ceiling (1) Install the suspension bolts. Wooden structures •…

  • Page 6
    Connect the Connection Kit to the liquid pipe and install it inside the ceiling or on a wall (Do not install in an outdoor location. It may cause a breakdown). Make sure to install the access door on the ceiling. Installation location •…
  • Page 7
    Installation pattern C (Installing the unit on a wall.) Set the Connection Kit mounting plate as shown below. (Unit: mm) Install the two screws (5 × 10) Mounting plate Anchor nuts (procure locally) Ceiling ANCHOR NUT PITCH SERVICE SPACE Wall 4-Oval holes Wall MIN.50…
  • Page 8: Installing The Refrigerant Piping

    2.3.2. Installing the refrigerant piping Check the Connection Kit accessories and parts 1Pipe cover × 2 2Thermistor holder — ø9.52 × 1 3Thermistor holder — ø12.7 × 1 Connect Connection Kit to the liquid pipe. When brazing the refrigerant pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat.

  • Page 9
    2.3.3. Installing the thermistors Be sure to install the thermistors (gas) supplied with the unit as shown in the illustration. • If the thermistors are not installed, the unit will not operate. If the thermistors are installed incorrectly, the unit will not operate properly.
  • Page 10
    (2) Insulate the thermistor with the supplied thermal insulation (procure locally). Thermal insulation (procure locally) (3) Cut a 100 mm slit on the top portion of the extension piping pipe cover, and then cover the thermistors with the pipe cover. Pipe cover (procure locally) (4) Wrap the thermal insulation covering the thermistor with tape.
  • Page 11: Wiring Of Main Power Supply And Equipment Capacity

    2.3.4. Electrical work 2.3.4.1. Caution (1) Follow local regulations and ordinances for technical standards related to electrical equipment, wiring, and Outdoor unit Connection kit Connection kit specifications of each electric power company. (51) (01) (02) (2) Wiring for control (hereinafter referred to as transmission line) must be situated at least 5 cm from the power source wiring M2 S M2 S…

  • Page 12
    1. Use separate power supplies for the outdoor unit and connection kit. 2. Consider the ambient conditions (ambient temperature, direct sunlight, rain, etc.) when wiring and making connections. 3. The wire size is the minimum value for metal conduit wiring. The power cord size must be 1 rank thinker in consideration of voltage drops.
  • Page 13
    Examples of UNACCEPTABLE unit configurations (2) Connecting an MA & Contact Termianl Interface using (1) Grouping with CITY MULTI indoor unit IT terminal The connection kit cannot be in the same group to which a CITY MULTI Address: 51 indoor unit belongs because their signal information differs.
  • Page 14
    Examples of ACCEPTABLE unit configurations (1) Connecting with CITY MULTI outdoor unit A: PURY A: PUHY Address: 51 Address: 51 Address: 01 Address: 01 A-control A-control Address: 52 TB02 A Outdoor unit A Outdoor unit B Connection kit B Connection kit C Indoor unit C Indoor unit D Remote controller…
  • Page 15
    (4) Grouping with multi-connection kit and RAC indoor units Address: 51 Address: 51 Address: 51 Address: 01 Address: 02 Address: 01 Address: 02 Address: 01 Address: 02 A-control A-control A-control A-control A-control A-control Group Group Group A Outdoor unit A Outdoor unit A Outdoor unit B Connection kit B Connection kit…
  • Page 16
    2.3.4.4. Wiring Check the Connection Kit accessories and parts 1Cable band × 2 2Thermistor (1) Remove the electrical cover. (2) Install the two cable bands 1. Electrical cover 1Cable band Electrical wire inlet (Power supply, To indoor unit) AT-adapter board Bands Electrical wire inlet (To outdoor unit, From gas thermistor) Terminal block…
  • Page 17: Refrigerant Piping

    2.3.5. Refrigerant piping Indoor unit connection example • Connect one connection kit per indoor unit. • Connect the connection kit the liquid pipe. • The thermistor-G (gas) is installed close to the connecting point of the extension piping (gas) for the indoor unit. Connection kit MAX.

  • Page 18: Dip Switch Setting

    1-10 (897) -*K* series or later (0: OFF, 1: ON) 3. Specifications SPECIFICATIONS OF OPTIONAL PARTS MODEL PAC-LV11M-J Power source Single/220-240 V/50/60 Hz Connectable number of indoor units External finish Hot-dip zinc-coated steel sheet (No external finish) External dimension H×W×D 183 ×…

  • Page 19: Outlines And Dimensions

    4. Outlines and dimensions…

  • Page 20: Wiring Diagram

    5. Wiring diagram…

  • Page 21: Refrigerant System Diagram

    6. Refrigerant system diagram Gas pipe thermistor TH23 Gas pipe Liquid pipe Brazed connections Strainer (#100 mesh) Linear expansion valve Indoor unit Connection kit…

  • Page 22: Troubleshooting

    7. Troubleshooting 7.1. Test run Caution: Before operating the unit, check that the wiring, piping, and thermistor are installed and that the switches have been set. Refer to the «Test run» section of the indoor units and outdoor unit installation manuals. After installation of an indoor unit, connection kit, and outdoor unit, begin a test run to check water leaks in the connection kit.

  • Page 23: Check Methods

    7.2. Check methods 1. Component and check points (1) Thermistor Gas pipe thermistor (TH23) Disconnect the connector and measure the resistance between terminals with a tester. (Ambient temperature 10°C — 30°C) Normal Abnormal 4.3kΩ — 9.6kΩ Open or short (Refer to the thermistor characteristic graph below.) 1) Thermistor characteristic graph Low-temperature thermistor Gas pipe thermistor (TH23)

  • Page 24
    1) Summary of linear expansion valve (LEV) operation The LEV is operated by a stepping motor, which operates by receiving a pulse signal from the controller board. The LEV position changes in response to the pulse signal. Controller board and LEV connection 12VDC Brown White…
  • Page 25
    2) LEV operation Close Open Fully open valve (2000 pulses) No. of pulses Extra tightening (80 — 100 pulse) Valve opening degree When the power is turned on, a pulse signal of 2200 pulses is output (valve closure signal), to bring the valve to position A. When the valve is operating normally, it is free of vibration noise.
  • Page 26: Dip Switch Setting (Factory Setting)

    Symptom Checking Criteria Remedy Valve closure fail- To check the LEV on the connection kit, check the indoor unit liquid pipe tempera- Replace the LEV ure (leaky valve) ture that appears on the operation monitor on the outdoor unit’s multi control board if the amount of while operating the indoor unit in question in the FAN mode and the other indoor leakage is great.

  • Page 27
    2. Capacity code setting (1) SW2 Dipswitch settings must be made while the unit is stopped. Factory setting = Every switch is set to OFF. The switches are set to correspond to the indoor unit capacity. Model P15, P20 P32, P35 P40, P42 P100 P125…
  • Page 28
    Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN Authorized representative in EU:MITSUBISHI ELECTRIC EUROPE B.V. HARMAN HOUSE, 1 GEORGE STREET, UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT06728X03…

Наименование PAC-LV11M-J Количество портов 1 Совместимые внутренние блоки MSZ-LN25~50VG2, MSZ-FH25~50VE,
MSZ-EF22~42VGK (только с PUMY),
MSZ-EF50VGK (только с PUMY(S)P112-200),
MSZ-AP15/20VGK (кроме PUMY-P),
MSZ-AP25~42VGK (только с PUMY),
MSZ-AP50VGK (только с PUMY(S)P112-200),
MFZ-KT25~50VG (кроме PUMY-SP) Совместимые наружные блоки PUMY-(S)P VKM/YKM/YBM, PUCY-(E)P Y(S)KA,
PUHY-(E)P Y(S)NW-A1,
PUHY-HP YHM-A, PQHY-P YLM-A1,
PURY-P Y(S)NW-A1, PQRY-P YLM-A1 Габаритные размеры (В×Ш×Д) 183 мм х 355 мм х 142 мм Вес прибора 3,5 кг Фреонопровод (жидкость) 6,35 мм (1/4), пайка Фреонопровод (газ) нет Электропитание 1 фаза, 220 В, 50 Гц Подключение дренажного трубопровода не требуется Совместимые пульты управления Беспроводные пульты управления Сигнальные линии M-NET (CITY MULTI) и «new A-control» (RAC) Завод (страна) MITSUBISHI ELECTRIC CORPORATION AIR-CONDITIONING & REFRIGERATION SYSTEMS WORKS (Япония)
Topics
manualzz, manuals, Mitsubishi Electric PAC-LV11M-J manual, PAC-LV11M-J pdf download, PAC-LV11M-J Installation manual, Mitsubishi Electric user manuals, Mitsubishi Electric service instructions, PAC-LV11M-J instructions,
Collection
manuals_mitsubishi; manuals; additional_collections
Language
English
Addeddate
2020-11-21 14:27:28
Identifier
manualzz-id-755717
Identifier-ark
ark:/13960/t5r884464
Ocr
ABBYY FineReader 11.0 (Extended OCR)
Page_number_confidence
96.30
Ppi
300
Scanner
Internet Archive Python library 1.9.3

plus-circle Add Review

comment

Reviews

There are no reviews yet. Be the first one to
write a review.

53

Views

DOWNLOAD OPTIONS


download 1 file

ABBYY GZ download


download 1 file

DAISY download

For print-disabled users


download 1 file

EPUB download


download 1 file

FULL TEXT download


download 1 file

ITEM TILE download


download 1 file

KINDLE download


download 1 file

PAGE NUMBERS JSON download


download 1 file

PDF download


download 1 file

SINGLE PAGE PROCESSED JP2 ZIP download


download 1 file

TORRENT download

download 12 Files

download 6 Original

SHOW ALL

IN COLLECTIONS

Manuals: Mitsubishi

The Manual Library

Additional Collections

Uploaded by

chris85

on

MITSUBISHI ELECTRIC
United Kingdom

Contents icon Contents

switch icon

Pages
 | 
Spreads


of 28

Zoom
Zoom in / out
double click

Download icon Download

print icon Print

Envelope icon Email

Search icon
Search icon
Close
Close

Download PDF

Download PDF


Email

Email


Table of Contents for Mitsubishi Electric PAC-LV11M-J:

  • 24 GB 1) Summary of linear expansion valve (LEV) operation The LEV is operated by a stepping motor, which operates by receiving a pulse signal from the controller board. The LEV position changes in response to the pulse signal. Controller board and LEV connection Pulse signal output and valve operation The output pulse changes in the following order: When the valve closes 1 -> 2 -> 3 -> 4 -> 1 When the valve opens 4 -> 3 -> 2 -> 1 -> 4 When th

  • 2 GB Contents 1. Safety precautions ……………………………………………………………… 2 1.1. Before installation and electric work ………………………… 2 1.2. Precautions for devices that use R410A refrigerant …… 2 1.3. Before getting installed ………………………………………….. 3 1.4. Before getting installed (moved) — electrical work ………. 3 1.5. Before starting the test run………………………………..

  • WT06728X03 Printed in Japan This product is designed and intended for use in the residential, commercial and light-industrial environment. The product at hand is based on the following EU regulations: • Low Voltage Directive 2006/95/EC • Electromagnetic Compatibility Directive 2004/108/EC Please be sure to put the contact address/telephone number on this manual before handing it to the customer. HEAD OFFICE: TOKYO BLDG., 2-7-3, MARUNOUCHI, CHIYODA

  • 8 GB 2.3.2. Installing the refrigerant piping Check the Connection Kit accessories and parts 1Pipe cover × 2 2Thermistor holder — ø9.52 × 1 3Thermistor holder — ø12.7 × 1 Connect Connection Kit to the liquid pipe. When brazing the refrigerant pipes, be sure to braze, after covering a wet cloth to the insulation pipes of the units in order to prevent it from burning and shrinking by heat. Press the pipe cover 1 on the liquid piping against the Connec

  • 12 GB 1. Use separate power supplies for the outdoor unit and connection kit. 2. Consider the ambient conditions (ambient temperature, direct sunlight, rain, etc.) when wiring and making connections. 3. The wire size is the minimum value for metal conduit wiring. The power cord size must be 1 rank thinker in consideration of voltage drops. Make sure that the power supply voltage does not drop more than 10%. 4. Select non-fuse breaker (NFB) or earth leakage breaker (N

  • 20 GB 5. Wiring diagram LED1 LED (Power supply)LED1 (Blue) (Blue) (Red) (Red) (Red) M DC280-340V Rectifier circuit LEV ZNR001 NR F001 A.B. SW5 SWC SW11 SW12 SW14 SWA SW1 SW4 SW2 SW3 123 2 1 2 3 3 5 5 1 4 5 6 C.B. P. B. CITY MULTI CONNECTION KIT 3 2 2 4 4 4 2 2 2 2 2 2 3 4 5 1 1 3 3 3 1 1 1 1 1 1 1 2 CN60 CNXB2 CNXC2 CN2S CNSK SA TAB1 CN351 CN570 CN450 CN001 TB2 TB TB5 S1 L M1 S2 N M2 S3 S CN44 TH23 CN2M CN105 TO OUTDOOR UNIT REMOTE CONTROLLER U U POWER SUPPLY ޓ AC220-240V �

  • 13 GB Examples of UNACCEPTABLE unit configurations (1) Grouping with CITY MULTI indoor unit (2) Connecting an MA & Contact Termianl Interface using IT terminal A Outdoor unit B Connection kit C Indoor unit D Remote controller E CITY MULTI indoor unit F Remote controller (ME) G M-NET transmission cable A Outdoor unit B Connection kit C Indoor unit D M-NET Interface E System controller (3)-1 When using wireless remote controller (3)-2 When using MA remote controller A Outdoor unit B Connection kit C Indoor unit D Remote controller

  • 19 GB 4. Outlines and dimensions Note 3 Screw bolt (M5×10) 34 109 15 20 15 6858 24 Installation plate 2-ø12 holes (For suspension bolt) 4-10×5 oblong holes (For plane surface installation) 4-10×5 oblong holes (For wall surface installation) ޓ 㧨Accessories㧪 ޓ࡮Installation plate 㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯 1pc. ޓ࡮Gas thermistor 㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯㨯 1pc. ޓ࡮Thermistor holder (ø9.52) 㨯㨯㨯㨯㨯㨯�

  • 7 GB Installation pattern C (Installing the unit on a wall.) Set the Connection Kit mounting plate as shown below. Installation pattern D (Installing the unit on a wall.) Set the Connection Kit mounting plate as shown below. Mounting plate Install the two screws (5 × 10) Install the four screws (4×50 procure locally) in oval holes. Anchor nuts (procure locally) Wall Wall Ceiling 4-Oval holes 183 SERVICE SPA

  • 9 GB 2.3.3. Installing the thermistors Be sure to install the thermistors (gas) supplied with the unit as shown in the illustration. • If the thermistors are not installed, the unit will not operate. If the thermistors are installed incorrectly, the unit will not operate properly. Take precaution so that condensation does contact the thermistor leads or enters the electrical devices. Before installing thermal insulation to the frame connecting points of the indoor

Questions, Opinions and Exploitation Impressions:

You can ask a question, express your opinion or share our experience of Mitsubishi Electric PAC-LV11M-J device using right now.

Like this post? Please share to your friends:
  • P8z77 v le plus инструкция на русском
  • P60 pro часы инструкция по применению на русском
  • P8h61 m lx2 инструкция на русском
  • P8b смарт часы инструкция на русском
  • P5gc mx 1333 инструкция на русском