- Manuals
- Brands
- Pixsys Manuals
- Controller
- ATR 121
- User manual
-
Contents
-
Table of Contents
-
Bookmarks
Quick Links
ATR 121-141
Controller
User manual
Related Manuals for Pixsys ATR 121
Summary of Contents for Pixsys ATR 121
-
Page 1
ATR 121-141 Controller User manual… -
Page 3: Table Of Contents
Summary Safety guide lines …………….5 Model identification …………….6 Technical data ………………6 General features …………..6 Hardware features …………….7 Software features …………..8 Dimensions and installation …………8 Electrical wirings ……………..9 Wiring diagram ……………9 Display and keys functions ………….13 Numeric indicators (Display) ……….13 Meaning of status lights (Led) ………..13 Keys ……………….13 Controller functions ……………..14 Modifying main setpoint and alarm setpoint values..14…
-
Page 4
ATR121/141 — Manuale d’uso… -
Page 5: Safety Guide Lines
, while LATCH ON function speeds up the device calibration when linear potentiometers are used. As on the latest Pixsys instrumentation, the configuration is further simplified by the Memory cards which are provided with internal battery and therefore do not require cabling to power the controller.
-
Page 6: Model Identification
Model identification ATR121-141 12..24Vac ±10% 50/60Hz 12..35Vdc ATR121-141 24 Vac ±10% 50/60 Hz ATR121-141 230 Vac ±10% 50/60 Hz ATR121-141 115 Vac ±10% 50/60 Hz ATR121-141 ADT 12..35Vdc + RS485 Relay Q2 not available, alarm function available on SSR output. Technical features 3.1 General features 3 displays (0,56 inch) on ATR121…
-
Page 7: Hardware Features
Hardware features An1. Configurable via Tolerance (25°C) software. Thermocouple +/-0.5 % ± 1 digit (full type: K, S, R, J. Automatic scale) for thermocouple compensation of cold input, thermo- junction from 0°C to resistance and V/mA. 50°C. Analogue Cold junction accuracy Thermoresistance: inputs 0.2°C/°C…
-
Page 8: Software Features
4.1 Software features Regulation ON-OFF with hysteresis. algorithms P, PI, PID, PD with proportional time Proportional band 0..999°C or °F Integral time 0..999s (0 excludes integral function) Derivative time 0..999s (0 excludes derivative function) Manual or automatic Tuning, configurable Controller alarm, protection of command and alarm functions setpoints, heating/cooling PID function.
-
Page 9: Electrical Wirings
Electrical wirings Although this controller has been designed to resist electromagnetic interferences in industrial environments, please observe following safety guidelines: • Separate control line from power wires. • Avoid proximity of remote control switches, electromagne- tic contactors, powerful engines and in all instances use specific filters. • Avoid proximity of power groups, especially those with phase control 6.1 Wiring diagram Models: ATR121-AD / ADT and ATR141-AD / ADT…
-
Page 10
An1 Analogue Input For thermocouples K, S, R, J. • Comply with polarity • For possible extensions, use compensated cable and terminals suitable for the thermocouples Shield/Schermo used(compensated) • When shielded cable is used, it should be grounded at one side only (only for models: AD / ADT) For a correct functioning of the device, use sensors insulated from the ground. -
Page 11
For linear signals V/mA Shield/Schermo • Comply with polarity • When shielded cable is used, it should be grounded at one side only Examples of connection for linear input For signals 0….10V 0…10V • Comply with polarity For signals 0/4….20mA with three-wire sensor • Comply with polarity 0/4…20mA C = Sensor output B = Sensor ground A = Sensor power supply (12V/30mA) PRESSURE TRANSMITTER… -
Page 12
Serial input RS485 Modbus RTu communication Do not use LT (line termination) resistors Shield/Schermo • For networks with more than five instruments supply in low voltage Relay outputs Capacity: • Q1 (ATR121/141 A-B-c): 8A, 250Vac, resistive loads, 10 operations • Q1 (ATR121/141 AD/ADT): 10A, 250Vac, resistive loads, 10 operations • Q2 (not on ATR121/141 ADT): 5A, 250Vac,… -
Page 13: Display And Keys Functions
Display and keys functions 7.1 numeric indicators (Display) 1234 Normally displays the process. 7.2 Meaning of status lights (Led) ON when command output is active. When 2 OuT1 it flashes, display shows the command output setpoint (which can be modified by arrow keys). ON when alarm output is active.
-
Page 14: Controller Functions
• Allows to increase main stepoint. • During configuration it allows to scroll through parameters and to modify them togheter with • If pressed after , it allows to increase the setpoints (command with OUT1 flashing/ alarm with OUT2 flashing). • If pressed once it allows to visualize the command setpoint. • If pressed twice it allows to visualize the alarm setpoint. • Allows to modify configuration parameters. • Allows to run the manual Tuning function. • Allows to enter/exit from configuration. controller functions 8.1 Modifying main setpoint and alarm setpoint values…
-
Page 15: Tuning
Tuning Tuning procedure allows to calculate PID parameters to obtain a good regulation. It means a stable control of temperature/ process on setpoint without fluctuations and fast response to deviations from setpoint caused by external noises. Tuning procedure includes calculation and setting of the following parameters: • Proportional band (system inertia in °C if temperature).
-
Page 16: Automatic Tuning
Confi rming with , the controller loads the new data and starts again. Pressing display shows m-no and the controller starts keeping values unchanged. PIXSYS Memory Card (optional) Memory Card (optional) Cod. 2100.30.005 with battery/con batteria Cod. 2100.30.003…
-
Page 17: Latch On Function
• With the controller not connected to power supply: The memory card is equipped with an internal battery with an autonomy of about 1000 operations (button battery 2032, replaceable). Insert the memory card and press the programming button . When writing the parameters, the led turns red and on completing the procedure it turns green.
-
Page 18
Press Display Exit parameters Place the sensor on confi guration. minimum operating Device visualizes value (associated with alternately process Lo. n) and Lat Place the sensor on Set the value on maximum operating minimum. value (associated with Display shows Lo Hi. -
Page 19: Dual Action Heating-Cooling
9.6 Dual action Heating-cooling The ATR121/141 is suitable also for systems requiring a combined heating-cooling action. Command output must be configured as Heating PID (par.11 reG. = Hea | Heat and par. 15 p.b. greater than 0), and one of the alarm must be configured as cooling action (par.
-
Page 20
x = COOL x = COOL x = COOL < 0 < 0 < 0 (HEAT) (HEAT) (HEAT) ACTIVE COMMAND OUTPUT (HEAT) ACTIVE COMMAND OUTPUT (HEAT) COMMAND OUTPUT (HEAT) ACTIVE ACTIVE ALARM OUTPUT (COOL) -
Page 21: Dead Band Function
time t.c.2 basing on the type of cooling fluid: co.f | coo.f cooling fluid type P.b.m t.c.2 1.00 1.25 Water 2.50 Dead band function The dead band function (enabled selecting F.b.M on par. 28 FNc | Func.) creates a band within which the relays are both open or closed.
-
Page 22: Serial Communication
Serial communication ATR121/141 is equipped with RS485, it can receive and broadcast data via serial communication using MODBUS RTU protocol. The device can be configured only as Slave. This function enables the control of multiple devices connected to a supervisory system. The RS485 line must be free of LT termination resistances to avoid malfunctions.
-
Page 23
list below includes available addresses: RO = Read Only R/W = Read/Write WO = Write Only MoDBus Read Reset Description Address Write value Device type R 101/102 Software version Reserved Reserved Reserved Slave Address EEPR Reserved Loading default values (write 9999) 1000 Process 1001… -
Page 24
1009 Start/Stop 0 = controller in STOP 1 = controller in START 1010 OFF LINE time (milliseconds) 2001 Par. 1 c.ou — c.out R/W EEPR 2002 Par. 2 sen — sen. R/W EEPR 2003 Par. 3 d.p. — d.p R/W EEPR 2004 Par. -
Page 25
2028 Par. 28 FNc — Func. R/W EEPR 2029 Par. 29 Gra — Grad. R/W EEPR 2030 Par. 30 bd.r — bd.rt. R/W EEPR 2031 Par. 31 add — addr. R/W EEPR 2032 Par. 32 de.s — dL.sr. R/W EEPR 2033 Par. -
Page 26: Configuration
12.2 Loading default values This procedure allows to restore factory settings of the device. Press Display Display shows 000 | 0000 with the 1st for 3s digit flashing. Change the flashing digit and move to the Enter password 999 | 9999 next one pressing Instrument loads default settings and…
-
Page 27
02 sen Sensor Analogue input configuration. For a correct functioning of the device, use sensors insulated from the ground. Otherwise, use a single transformer isolated for each instrument. tck | tc k Tc-K -260 °C .. 1360 °C (default) tc.s | tc. s Tc-S -40 °C .. -
Page 28
05 Hi.s. upper Limit Setpoint -199 .. 999 | -999 .. 9999 Value expressed as degrees.tenths for temperature sensors and digits for linear sensors and potentiometers (default: 999 for ATR121 and 1750 for ATR141). 06 Lo. N Lower Linear Input Range AN1 lower limit only for linear signals. -
Page 29
10 cA.G | cAL.G Gain calibration Percentage value that is multiplied for the process value (allows to calibrated the working point) -19.9% .. 99.9% | -99.9% .. 99.9% Percentage (default 0.0) 11 ReG. Regulation type HEA | HEAT Heating (N.A.) (Default) coo | cooL Cooling (N.C.) m.r. -
Page 30
15 p.b. Proportional band Proportional band Process inertia in units (in °C if temperature) 0 .. 999 | 0 .. 9999 0 = On/Off Value degrees.tenths for temperature sensors and digit linear sensors and potentiometers (default 0) 16 t.i. Integral time Process inertia in seconds 0 .. -
Page 31
20 c.r.a Alarm state output Output contact and intervention type Normally open, active at start (default) n.o.s Normally closed, active at start n.c.s Normally open, active on reaching alarm n.o.r Normally closed, active on reaching alarm n.c.r 21 s.c.a Alarm state error State of contact for alarm output in case of error Open contact (default) c.o. -
Page 32
25 p.se. Setpoint protection Allows or not to modify the setpoint by keyboard. fre | free Both set can be modified (default) pr.s | pro.s OUT1 command setpoint protection pr.a | pro.a OUT2 alarm setpoint protection aLL | aLL Both set protection 26 fiL | FiLt. -
Page 33
29 Gra | Grad. Degree selection Select degree type Centigrade (default) c Fahrenheit f 30 bd.r | bd.rt. Baud rate Selects baud rate for serial communication mb. 1 | mdb. 1 300 bit/s mb.2 | mdb.2 9600 bit/s mb.3 | mdb.3 19200 bit/s (default) mb.4 | mdb.4 38400 bit/s 31 add | addr. -
Page 34
35 ou.d | ou.d.b. Overlap / dead band Dead band combination for heating/cooling action in heating / cooling PID.mode (par. 12) -20.0 .. 50.0% of par. p.b. value (default 0). Negative indicates dead band value, positive means overlap. 36 t.c.2 cooling cycle time Cycle time for cooling output (par. -
Page 35: Alarm Intervention Modes
Alarm intervention modes Absolute alarm or threshold alarm (A. A | AL.A. selection) Absolute alarm with Alarm Spv controller in heating Hysteresis parameter functioning (par. 11 reG. > 0 come Hea | Heat) and hysteresis (par. 23 HY.a | Time Hys.a) in absolute value.
-
Page 36
Band alarm (A. b | AL.. selection) Band alarm with hysteresis. N.B.: hysteresis (par. 23 HY.a | Hys.a) can not be lower than 0. The alarm value is the Hysteresis upper or lower deviation parameter > 0 from the command setpoint that enables the output. -
Page 37
Upper deviation alarm Comand Spv Comand Spv value of alarm Alarm Spv Alarm Spv Alarm Spv Alarm Spv setpoint less than “0”. Hysteresis parameter N.B.: hysteresis (par. 23 > 0 HY.a | Hys.a) can not be Time lower than 0. Alarm output Lower deviation alarm (A.d.i | AL.D.i selection) -
Page 38: Table Of Anomaly Signals
Table of anomaly signals If installation malfunctions, controller will switch off regulation output as selected on par. 12 s.c.c./21 s.c.a and will report the anomaly. Example: controller will report failure of a connected thermocouple visualizing e-5 (flashing). For other signals, see table below. Cause Error in EEPROM cell e- 1 | e-01…
-
Page 39: Summary Of Configuration Parameters
Summary of configuration parameters Date: Model ATR121/141: Installer: System: Notes: Par. Description setting Command output type selection c.out Analogue input configuration sen. Number of decimal points d.p. Lower limit setpoint Lo. s. Upper limit setpoint Hi. s. Lower limit range AN1 only for linear Lo.
-
Page 40
28 func. Functioning 29 Grad. Degree selection 30 bd.rt. Baud rate 31 addr. Slave address 32 dL.sr. Serial delay 33 coo.f. Cooling fluid 34 p.b.m. Proportional band multiplier 35 ou.db. Overlap / Dead band 36 t.c. 2 Cycle time 2 37 fLt.v Visualization filter notes / updates… -
Page 41
Prima di utilizzare il dispositivo leggere con attenzione le informazioni di sicurezza e settaggio contenute in questo manuale. PIXSYS s.r.l. www.pixsys.net sales@pixsys.net — support@pixsys.net online assistance: http://forum.pixsys.net 2300.10.056-RevE Software Rev. 3.05 090913…
This manual is also suitable for:
Atr 141
Этот регулятор я выбрал только потому что он на практике показал свою надёжность. Цена у него тоже приемлема, и в технических параметрах указано что он может храниться при температурае до -30 градусов. Это важно поскольку оборудование зимой стоит на улице.
Pixsys
ATR121 настройка
регулятора.
Кнопки:
SET
изменение
текущего задания OUT1
или
OUT2
FNC
Функциональная
кнопка доступа к параметрам и выхода
из режима параметров.
Δ
Кнопка
“На
верх”
изменение
задания или параметра в режиме параметров
∇ Кнопка
“Вниз”
изменение
задания или параметра в режиме параметров
Изменение
задания.
«1 уровень
»:
-
Если
нажать кнопки Δ
или ∇
то
регулятор сразу изменяет задание для
OUT
1. При
этом индикатор OUT
1
мигает.
-
Можно
нажать на кнопку SET.
Тогда
регулятор переходит к изменению OUT
1. Так
же мигает индикатор OUT
1. Если
нажать ещё раз SET
то
регулятор перейдёт на изменение задания
OUT
2. Будет
мигать индикатор OUT
2. -
После
окончания изменения задания регулятор
сам автоматически перейдёт в режим
индикации текущей температуры.
Изменение
параметров регулятора.
Нажать
кнопку
FNC на
5 сек.
На
дисплее появятся
000 и
первый с лева ноль будет мигать.
Кнопкой▲
изменить
значение на
1. Перейти
к следующей цифре можно нажав кнопку
SET. Весь
пароль:
123
Выход
из режима параметрирования — нажать
кнопку FNC.
Параметр |
Описание |
Значение |
c.ou |
Типы |
Не |
SEn. |
Выбор |
Pt1 |
dP. |
Десятичная |
|
Lo.S. |
Нижний |
0 |
Hi.S. |
Верхний |
120 |
cA.o |
Коррекция |
+ |
rEG. |
Тип работы. Нагрев или |
В |
HY.c |
Гистерезис. Возврат |
2.0 |
Остальные
параметры не меняются. Александр
Клапин
Изображения служат только для ознакомления,
см. техническую документацию
* Специальные цены действуют только при заказе на сайте или в приложении
от 5 шт. —
24 300 руб.
от 10 шт. —
22 440 руб.
Добавить в корзину 1 шт.
на сумму 27 020 руб.
Номенклатурный номер: 8002514409
Артикул: ATR121-AD
Бренд / Производитель: PIXSYS
Описание
АвтоматикаРегулировка и управлениеРегуляторыРегуляторы температуры
Технические параметры
Сроки доставки
Доставка в регион Курск
Магазин «ЧИП и ДИП» | 11 октября1 | бесплатно |
ПВЗ Л-Пост | 10 октября1 | бесплатно |
ПВЗ СДЭК | 10 октября1 | бесплатно |
ПВЗ Яндекс Доставка | 11 октября1 | бесплатно |
ПВЗ Boxberry | 11 октября1 | бесплатно |
ПВЗ 5Post | 17 октября1 | бесплатно |
Почта России | 18 октября1 | бесплатно |
Курьер | 10 октября1 | 416 руб.2 |
ТК DPD | 9 октября1 | 584 руб.2 |
ТК «Деловые линии» | 10 октября1 | 843 руб.2 |
Цена и наличие в магазинах
ул. Карла Маркса, 68, ТЦ «Мега Гринн», 1 этаж | нет в наличии |
Количество | Цена ₽/шт |
---|---|
1 | 29 815 |
5 | 28 751 |
10 | 27 687 |
SET
изменение
текущего задания OUT1
или
OUT2
FNC
Функциональная
кнопка доступа к параметрам и выхода
из режима параметров.
Δ
Кнопка
“На
верх”
изменение
задания или параметра в режиме параметров
∇ Кнопка
“Вниз”
изменение
задания или параметра в режиме параметров
Изменение
задания.
«1 уровень
»:
-
Если
нажать кнопки Δ
или ∇
то
регулятор сразу изменяет задание для
OUT
1. При
этом индикатор OUT
1
мигает.
-
Можно
нажать на кнопку SET.
Тогда
регулятор переходит к изменению OUT
1. Так
же мигает индикатор OUT
1. Если
нажать ещё раз SET
то
регулятор перейдёт на изменение задания
OUT
2. Будет
мигать индикатор OUT
2. -
После
окончания изменения задания регулятор
сам автоматически перейдёт в режим
индикации текущей температуры.
Изменение
параметров регулятора.
Нажать
кнопку
FNC на
5 сек.
На
дисплее появятся
000 и
первый с лева ноль будет мигать.
Кнопкой▲
изменить
значение на
1. Перейти
к следующей цифре можно нажав кнопку
SET. Весь
пароль:
123
Выход
из режима параметрирования — нажать
кнопку FNC.
Параметр |
Описание |
Значение |
c.ou |
Типы |
Не |
SEn. |
Выбор |
Pt1 |
dP. |
Десятичная |
|
Lo.S. |
Нижний |
0 |
Hi.S. |
Верхний |
120 |
cA.o |
Коррекция |
+ |
rEG. |
Тип работы. Нагрев или |
В |
HY.c |
Гистерезис. Возврат |
2.0 |
Остальные
параметры не меняются. Александр
Клапин
Изображения служат только для ознакомления,
см. техническую документацию
* Специальные цены действуют только при заказе на сайте или в приложении
от 5 шт. —
24 300 руб.
от 10 шт. —
22 440 руб.
Добавить в корзину 1 шт.
на сумму 27 020 руб.
Номенклатурный номер: 8002514409
Артикул: ATR121-AD
Бренд / Производитель: PIXSYS
Описание
АвтоматикаРегулировка и управлениеРегуляторыРегуляторы температуры
Технические параметры
Сроки доставки
Доставка в регион Курск
Магазин «ЧИП и ДИП» | 11 октября1 | бесплатно |
ПВЗ Л-Пост | 10 октября1 | бесплатно |
ПВЗ СДЭК | 10 октября1 | бесплатно |
ПВЗ Яндекс Доставка | 11 октября1 | бесплатно |
ПВЗ Boxberry | 11 октября1 | бесплатно |
ПВЗ 5Post | 17 октября1 | бесплатно |
Почта России | 18 октября1 | бесплатно |
Курьер | 10 октября1 | 416 руб.2 |
ТК DPD | 9 октября1 | 584 руб.2 |
ТК «Деловые линии» | 10 октября1 | 843 руб.2 |
Цена и наличие в магазинах
ул. Карла Маркса, 68, ТЦ «Мега Гринн», 1 этаж | нет в наличии |
Количество | Цена ₽/шт |
---|---|
1 | 29 815 |
5 | 28 751 |
10 | 27 687 |
Бесплатная доставка
Авторизируйтесь
и получите
+4153 балла
-
Условия
Минимально 1 шт и кратно 1 шт
Срок поставки 4 недели
Цена включает НДС -
Артикул
ATR121
-
Производитель
PIXSYS
-
Техническое описание:
Купить ATR121-B от 1 шт с помощью банковской карты можно прямо сейчас на нашем сайте.
Работаем с частными и юридическими лицами.
ATR121 описание и характеристики
Модуль: регулятор; температура; SPDT; OUT 2: SPST-NO; OUT 3: SSR
Бесплатная доставка
Доставим прямо в руки или в ближайший пункт выдачи
Перезвоните мне
Смежные товары
Похожие товары
Каталог
- Полупроводники
- Системы Embedded и IoT
- Oптоэлектроника
- Источники света
- Пассивные элементы
- Разъeмы
- Предохранители и защитные устройства
- Переключатели и индикаторы
- Источники звука
- Реле и контакторы
- Трансформаторы и сердечники
- Вентиляторы, сис. охлаждения и нагрева
- Источники энергии
- Провода и кабели
- Механические элементы
- Корпуса
- Автоматика
- Пневматика
- Оборудование мастерских
- Офисное оборудование
- Автомобильная аудиосистема
- Компьютерные аксессуары
- Робототехника и макетирование
Ваша заявка отправлена. В ближайшее время мы свяжемся с Вами по указанным контактам.
20800078
Enclosure, Accessory, Coding Pegs Срок поставки 3-4 недели
Заказанное количество не является кратным. Правильное количество должно быть кратным .
Чтобы увидеть статус своего заказа, введите пароль и номер заказа (высылаются на почту при оформлении заказа).
- Москва
- Санкт-Петербург
- Новосибирск
- Екатеринбург
- Нижний Новгород
- Абакан
- Анадырь
- Ангарск
- Апатиты
- Архангельск
- Астрахань
- Барнаул
- Белгород
- Бийск
- Биробиджан
- Благовещенск
- Братск
- Брянск
- Великий Новгород
- Владивосток
- Владикавказ
- Владимир
- Волгоград
- Волжский
- Вологда
- Воронеж
- Выборг
- Горно-Алтайск
- Грозный
- Дмитров
- Екатеринбург
- Иваново
- Ижевск
- Иркутск
- Йошкар-Ола
- Казань
- Калининград
- Калуга
- Кемерово
- Киров
- Краснодар
- Красноярск
- Курган
- Курск
- Кызыл
- Липецк
- Магадан
- Магас
- Магнитогорск
- Майкоп
- Махачкала
- Междуреченск
- Мурманск
- Нальчик
- Нарьян-Мар
- Нижний Новгород
- Новокузнецк
- Новороссийск
- Новосибирск
- Омск
- Оренбург
- Орёл
- Пенза
- Пермь
- Петрозаводск
- Петропавловск-Камчатский
- Подольск
- Псков
- Пятигорск
- Ростов-на-Дону
- Рязань
- Салехард
- Самара
- Саранск
- Саратов
- Севастополь
- Серпухов
- Симферополь
- Смоленск
- Сочи
- Ставрополь
- Сургут
- Сыктывкар
- Тамбов
- Тверь
- Тольятти
- Томск
- Туапсе
- Тула
- Тюмень
- Улан-Удэ
- Ульяновск
- Усолье-Сибирское
- Уссурийск
- Уфа
- Ухта
- Хабаровск
- Ханты-Мансийск
- Хасавюрт
- Чебоксары
- Челябинск
- Череповец
- Черкесск
- Чита
- Электросталь
Регистрация
Сохранение профиля
Данные сохранены!
Отменить удаление будет невозможно
Запись начинается на строке
Предварительный просмотр вашего файла отображается ниже. Ваши столбцы были сопоставлены на основе содержания вашего файла. Пожалуйста, просмотрите выбранные варианты и используйте выпадающие списки над каждым столбцом, чтобы внести какие-либо изменения, а также сопоставить столбцы, которые мы не смогли отобразить автоматически. Требуется столбец как для номера детали, так и для количества.
Способ доставки
Курьером
Самовывоз
Куда доставить заказ?
Выберите пункт выдачи на карте или используйте поиск
Определить местоположение
Куда доставить заказ?
Москва
Изменить
Добавьте точный адрес, удобный пункт выдачи или постамат, чтобы заранее увидеть условия доставки товаров
Выбрать на карте
адрес доставки, пункт выдачи, постамат
Выберите город
Москва
Санкт-Петербург
Казань
Республика Татарстан
Екатеринбург
Свердловская область
Новосибирск
Новосибирская область
Нижний Новгород
Нижегородская область
Челябинск
Челябинская область
Красноярск
Красноярский край
Самара
Самарская область
Уфа
Уфимская область
Краснодар
Краснодарский край
Mикропроцессорные регуляторы температуры имеют универсальный термометрический и аналоговый вход. Программируются с четырехкнопочной мембранной клавиатуры. Оснащены трехразрядным светодиодным индикатором с высотой знака 14 мм.
Входы: Pt100 Pt500 Pt1000 Ni100 PTC NTC J K S R Аналоговый Потенциометр |
: от -100°C до 600°C : от -100°C до 600°C : от -100°C до 600°C : от -60°C до 180°C : от -50°C до 150°C : от -40°C до 125°C : от -200°C до 999°C : от -260°C до 999°C : от -40°C до 999°C : от -40°C до 999°C : 0..10 В, 0..20 мA, 4..20 мA : 0..6 кОм, 0..150 кОм |
Выходы: Q1 Q2 SSR |
: реле 8A/ 250 VAC (для активных нагрузок) : реле 5A/ 250 VAC (для активных нагрузок) : 8 В/ 20 мА |
Одновременно можно использовать один вход управления и один сигнальный. | |
Диапазон рабочих температур Диапазон относительной влажности Питание Класс защиты Вес |
: от 0°C до +40°C : 0 ? 90 % : 230 VAC, 2,5 Вт : передняя панель IP65, корпус IP30 : ~ 170 г |
Программируются два порога переключения реле с характеристиками:
— управляющий порог ON-OFF, P, PD, PI, PID илиAUTOTUNING PID
— сигнальный порог ON-OFF
Класс защиты Габариты корпуса Монтажое отверстие Производитель |
: IP65 (спереди) : 77 x 35,3 x 61,2 мм : 70,5 x 28,5 мм : PIXSYS |