—————————————————— ——————————SLIT LAMP HS-5500
1
Operator’s Manual
SLIT LAMP MICROSCOPE HS-5500
Related Manuals for Huvitz HS-5500
Summary of Contents for Huvitz HS-5500
-
Page 1
—————————————————— ——————————SLIT LAMP HS-5500 Operator’s Manual SLIT LAMP MICROSCOPE HS-5500… -
Page 2
The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. HUVITZ assumes no responsibility, however, for possible errors o r omissions, or for any consequences resulting from the use o f the ormatio n contained herein. -
Page 3
—————————————————— ——————————SLIT LAMP HS-5500 HUVITZ reserves the right to make changes in its products or pro duct specificatio ns at any time and without prior notice, and is not required to update this documentatio n to reflect such changes. © 2009 HUVITZ Co ., Ltd. -
Page 4: Table Of Contents
SLIT LAMP HS- 5500——————- —————————————————————- Contents Introduction ………………….. 6 1.1. Indication for use ………………6. 1.2. Classification……………….. 6 Safety Infor mation………………..7 2.1. Introduction ………………..7 2.2. Safety Symbols ………………8 2.3. Environment factors…………….10 2.4. Safety Precautions……………… 12 Features & Operating Condit ion …………..14 3.1.
-
Page 5
—————————————————— ——————————SLIT LAMP HS-5500 10.1. Halogen Projection bulb …………….29 10.2. Protection fuses replacement…………..30 10.3. Cleaning & Disinfection …………….32 11. EMC Infor mation ………………..33 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions..33 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity ..34 11.3. -
Page 6: Introduction
Introduction 1.1. Indication for use (intended use) The SLIT LAMP, HS-5500 is intended for use in eye examination of the ant segments, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma which affects the structural properties of the anterior eye segment.
-
Page 7: Safety Information
—————————————————— ——————————SLIT LAMP HS-5500 Safety Information 2.1. Introduction Safety is everyone’s responsibility. The safe use of this equipment is largely dependent upon the installer, user, operator, and maintainer. It is imperative that personnel study and become familiar with this entire manual before attempting to install use, clean, service or adjust this equipment and any associated accessories.
-
Page 8: Safety Symbols
SLIT LAMP HS- 5500——————- —————————————————————- 2.2. Safety Symbols The International Electro technical Commission (IEC) has established a set of symbols for medical electronic equipment which classify a connection or warn of any potential hazards. The classifications and symbols are shown below. This applies only to the instrument that has the certification symbol printed explicitly on the product label or sticker.
-
Page 9
—————————————————— ——————————SLIT LAMP HS-5500 M EDIC AL EUIP M ENT W ITH RESP EC T TO ELEC TRIC SHOCK UL6 06 01 FIRE M E CH ANIC AL H AZ ARDS CAN/CS A C22 .2 ONLY IN ACCO RD ANCE W ITH U L 6 0601- NO.601 .1… -
Page 10: Environment Factors
SLIT LAMP HS- 5500——————- —————————————————————- 2.3. Environment factors Avoid the following environments for operation or storage: W here the equipment is expo sed to water vapor. ’ t operate equipment with a wet hand. W here the equipment is expo sed to direct sunlight. W here the temperature changes extremely °…
-
Page 11
—————————————————— ——————————SLIT LAMP HS-5500 W here equipment is exposed to chemical material or explosive gas. Be careful not to be inserted dust, especially, metal. ’ disassemble the pro duct or o pen. We aren ’ respo nsible for it fo r nothing. -
Page 12: Safety Precautions
The equipment must be operated only by, or under direct supervision of a properly trained and qualified person. Modifications of this equipment may only be carried out by Huvitz’s service technicians or other authorized persons. Customer maintenance of this equipment may only be performed as stated in the User’s Manual and Service Manual.
-
Page 13
The manufacturer is not liable for damage caused by unauthorized tampering with the device(s). Such tampering will forfeit any rights to claim under warranty. This equipment may only be used together with accessories supplied by Huvitz’s. If the customer makes use of other accessories, use them only if their safe usability under technical safety aspects has been proved and confirmed by Huvitz or the manufacturer of the accessory. -
Page 14: Features & Operating Condition
SLIT LAMP HS- 5500——————- —————————————————————- Features & Operating Condition 3.1. Brief Description The device works like all slit lamps: Stereomicroscopic examination of the eye under the slit light. Microscopic examination of the ocular fundus and posterior vitreou body (using hruby’s lens). These devices are designed for use by ophthalmologists and optometrists (within the realms of their respective professions) for specific diagnostic procedures (bio- microscopic examination of the eye)
-
Page 15
—————————————————— ——————————SLIT LAMP HS-5500 CAUTION Because prolo nged intense light exposure can damage the retina, the use of the device for ocular examinatio n sho uld no t be unnecessarily prolonged, and the brightness setting sho uld not exceed what is needed to pro vide cl visualizatio n o f the target structures. -
Page 16: Standard Components
SLIT LAMP HS- 5500——————- —————————————————————- Standard Components The instrument is delivered in package. Taking it out the package, make sure that none of the following parts is missing. A table top(N.B. the table top isn’t supplied with the slit lamp for twin table) on which are placed: A SMPS box(15) including the main switch &…
-
Page 17: Accessories
—————————————————— ——————————SLIT LAMP HS-5500 Accessories The following standard accessories are provided with the instrument; protection cover(46) a setting rod(43) spare bulbs 12V 30W Halogen bulb (53) chin-rest paper(47) spare fuses 250Vac T2.0AL a breath screen(5) power cable [ F i g u r e 1 . Ac c e sso r i e s ]…
-
Page 18: Composition
SLIT LAMP HS- 5500——————- —————————————————————- Composition Fixation point Control lever for changing enlargement Removable eye-pieces Knob for clamping the breath screen Breath screen Knobs to change the slit length Connecting plug of the projector lamp Knurled ring for filters insertion Joystick for lateral, longitudinal and vertical movements(x y z) 10) Base with orthogonal movements 11) Shaped tabletop…
-
Page 19
—————————————————— ——————————SLIT LAMP HS-5500 26) Locking pins for chin rest paper 27) Chin rest 28) Knobs to change the slit width 29) Pointer for the eye positioning 30) Forehead Rest 31) Microscope Lamp socket 33) Knob to lock the base of the instrument… -
Page 20
SLIT LAMP HS- 5500——————- —————————————————————- 54) Screw hole cover 55) Prism 56) Capture connector ( For the image system) 57) Capture switch 58) Luminosity selector connector ( Connect the Luminosity selector to the SMPS) 59) Head rest module 60) Diffuser… -
Page 21
—————————————————— ——————————SLIT LAMP HS-5500 [ Figure 2. Composition I ]… -
Page 22
SLIT LAMP HS- 5500——————- —————————————————————- [ Figure 3. Composition ¥±]… -
Page 23: Installation
—————————————————— ——————————SLIT LAMP HS-5500 Installation NOTE The appliances are always supplied with excellent packaging to be able to stand up to all kinds of transport and standard sto rage co nditions. P lease co ntact the suppliers if any irregularities are fo und in the appliance due to transport after unpacking 7.1.
-
Page 24
SLIT LAMP HS- 5500——————- —————————————————————- Place the head rest module(59) and make sure that its holes fit together with Those of the table top. Tighten the screw with the screw driver [ Figure 5. Assembling the instrument I] Place the base with orthogonal movements on the guides situated on the upper part of the table top, checking that the wheels are in line. -
Page 25
—————————————————— ——————————SLIT LAMP HS-5500 Assemble an optical group of the slit projector (49) on the Base with orthogonal movements (10). Then tighten the Guide screw with the screw driver(-) Put the microscope(31) in the right position making sure that it is placed well in the stop(37);… -
Page 26
SLIT LAMP HS- 5500——————- —————————————————————- [ Figure 6. Assembling the instrument ¥±]… -
Page 27: Trial Operations
—————————————————— ——————————SLIT LAMP HS-5500 Trial Operations Assemble the chin-rest paper (47) on the chin-rest (27). Let the patient sit down comfortable with his chin on the chin-rest and his forehead against the forehead-rest. Lift or lower the chin-rest by moving the handle (25) so that the patient’s eyes are in line with the notches on the chin-rest (29).
-
Page 28: Main Features
SLIT LAMP HS- 5500——————- —————————————————————- Main Features Principal operative characteristics of the instrument: Observation without settling or tiring and rapid change of enlargements. Base with cross-wise movement (which can be stopped) commanded by a single joystick for all adjustments(x y z). Stereomicroscopical observation of the eye with enlargements 6x-10x-16x-25x- 40x(when use 12.5x eyepieces ) ¢ª…
-
Page 29: Ordinary Maintenance
—————————————————— ——————————SLIT LAMP HS-5500 10. Ordinary Maintenance WARNING The repairs illustrated below should all be carried out with the power cable disconnected from the main supply plug. P lease contact the suppliers for any other pro blems that cannot be resolved by the operatio ns des ibed below.
-
Page 30: Protection Fuses Replacement
SLIT LAMP HS- 5500——————- —————————————————————- Fasten the bulb with the Bulb fastening knob Make sure that the stems of the bulb are completely inserted; insert the plug in the main supply socket [ F ig ure 7. Re p la c e Ha lo g e n b ulb ] WARNING Do n ’…
-
Page 31
—————————————————— ——————————SLIT LAMP HS-5500 The protection fuses are placed on the back of the SMPS, and inserted power socket. Before doing anything else, disconnect the plu from the main supply socket Remove the burned-out fuses Substitute the fuses and check Replace the plug in the main supply socket. -
Page 32: Cleaning & Disinfection
SLIT LAMP HS- 5500——————- —————————————————————- 10.3. Cleaning & Disinfection To keep the device clean, apply clinical alcohol and cidex or cidex plus on a soft cloth and scrub the body and the probe once a month. Do not lacquer, thinner, ethylene, or the oxidizing substance.
-
Page 33: Emc Information
—————————————————— ——————————SLIT LAMP HS-5500 11. EMC Information 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 34: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 35
—————————————————— ——————————SLIT LAMP HS-5500 <5% U? U? ) EUT image intensifier be (<95% dip in for 5 s Powered from U? ) uninterruptible power for 5 s supply or a battery. Power frequency 3 A/m 3 A/m Power frequency (50/60Hz) -
Page 36: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.3. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 37
—————————————————— ——————————SLIT LAMP HS-5500 and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, Should be less than the compliance level in each frequency range. Interference may occur in the vicinity of… -
Page 38: Recommended Separation Distances Between Portable And Mobile Rf
SLIT LAMP HS- 5500——————- —————————————————————- 11.4. Recommended separation distances between portable and mobile RF communications equipment and the EUT This is intended for use in an electromagnetic environment which radiated RF disturbances are controlled. The customer or the user the EUT can help Prevent electromagnetic interference by maintaining a minimum nce between portable and mobile RF communications equipment (transmitters)
-
Page 39: Immunity And Compliance Level
—————————————————— ——————————SLIT LAMP HS-5500 11.5. Immunity and Compliance Level Immunity test IEC 60601 Test Actual Immunity Compliance Level Level Level Conducted RF 3Vrms 3Vrms 3Vrms IEC 61000-4-6 150kHz to 80MHz Radiated RF 3Vrms 3V/m 3V/m IEC 61000-4-3 80MHz to 2.5GHz…
-
Page 40: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.6. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an electromagnetic environment.
-
Page 41
—————————————————— ——————————SLIT LAMP HS-5500 NOTE 1) These guidelines may not apply in all situatio Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. NOTE 2) It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification. -
Page 42: Electric Diagram
SLIT LAMP HS- 5500——————- —————————————————————- 12. Electric Diagram…
-
Page 43: Technical Specifications
—————————————————— ——————————SLIT LAMP HS-5500 13. Technical Specifications M IC R O SC O P E — H S-55005x T ype G alilean conv erging bin ocular M agnification 5 p osition s rotatingdrum E y epiece 12.5x T otal m ag nification…
-
Page 44
SLIT LAMP HS- 5500——————- —————————————————————- BASE Vertical Movement Min. 28mm Longitudinal Movement Min. 78mm. Lateral Movement Min. 98mm Fine base Movement Min. 10mm Power supply 100~ 24 0 V AC 50/ 60HZ 2.0A Power consumption 70VA Instrument Voltage 12V DC Halogen Projection bulb 12V 30W Fixation point LED… -
Page 45: Service Information
Seri al No .: ’ If you can t contact with your local distributo r, you can directly get in touch with the service department of the HUVITZ using the pho ne number and the address written in the below table.
-
Page 46
SLIT LAMP HS- 5500——————- —————————————————————- How to Co ntact HUVITZ Co ., Ltd Wri te us at: : +82-31 442-8868 HUVITZ Co ., Ltd. F ax : +82 31-442-8619 Huvitz B/D, 68 9 3 Geumjeong dong URL http://www.huvi tz.com Gunpo… -
Page 47: Particular Information
—————————————————— ——————————SLIT LAMP HS-5500 15. Particular Information 15.1. Relative spectral output graph (1) Halogen Lamp (2) Fixat ion Lamp…
-
Page 48
SLIT LAMP HS- 5500——————- —————————————————————- Note: this graph be shown for the beam after it exists the instrument, when the instrument is operating at maximum light intensity and maximum aperture. CAUTION “CAUTION – The light emitted from this instrument is potentially hazardous.
(Ocr-Read Summary of Contents of some pages of the Huvitz HS-5500 Document (Main Content), UPD: 05 February 2023)
-
27, Huvitz HS-5500 —————————————————— —————————— SLIT LAMP HS — 5 5 00 27 8. Trial Operations l l l l l l Assemb le the chin — rest paper ( 47) on the chin — rest ( 2 7). Let the patient sit down comfortable with his chin on the chin — rest and his forehead against the forehead — rest . Lift or lower the chin — rest by moving the handle (25) so that the patient ’ s eyes are i…
-
17, —————————————————— —————————— SLIT LAMP HS — 5 5 00 17 5. Accessorie s The following standard accessories are provided with the instrument; protection cover(46) a setting rod(43) spare bulbs 12V 30W Halogen bulb ( 53) chin — rest paper(47) spare fuses 250Vac T2.0AL a breath screen( 5 ) power cable l l l l l l l
… -
24, 24 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— l l l Place the head rest module(59) and make sure t hat its holes fit together with Those of the table top. Tighten the screw with the screw driver Place the base with orthogonal movements on the guides situated on the upper part of the table top, checking that the wheels are in line. T…
-
5, —————————————————— —————————— SLIT LAMP HS — 5 5 00 5 11. EMC Information ………………………….. ………………………….. ………………………… 33 12. Electric Diagram ………………………….. ………………………….. …………………………. 42 13. Technical Specifications …………………..…
-
12, 12 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— 2.4. Safety Precautions This equipment has been developed and tested according to safety stand ards as well as national and international standards. This guarantees a very high degree of safety for this device. The legislator expects us to inform the user exp…
-
46, 46 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— How to Contact HUVITZ Co., Ltd Write us at: Tel Fax U RL http://www. huvitz .co m e — mail: hs — support @huvitz.com HUVITZ Co., Ltd. Huvitz B/D, 689 — 3 Geumjeong — dong Gunpo — si Gyeonggi — do, South Korea 435 — 862 : +82 — 31 — 442 — 8868 : +82 — 31 — 442 — 8619 :
… -
8, Huvitz HS-5500 8 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— 2.2. Safety Symbols Save this instruction The International Electro technical Commission (IEC) has established a set of symbols for medical electronic equipment which classify a connection or warn of any potential hazards. The classifications and symbols are shown below. This applies only to the…
-
35, —————————————————— —————————— SLIT LAMP HS — 5 5 00 35 <5% U? (<95% dip in U? ) for 5 s U? ) for 5 s EUT image intensifier be Powered from an uninterruptible power supply or a battery. Power frequency (50/60Hz) magnetic field IEC 61000 — 4 — 8 3 A/m 3 A/m Power frequency magnetic fields s…
-
13, —————————————————— —————————— SLIT LAMP HS — 5 5 00 13 7. The manufacturer is not liable for damage caused by unauthorized tampering with the device(s). Such tampering will forfeit any rights to claim under warranty. 8. This equipment may only be used together with accesso ries supplied by Huvitz ’ s. If the customer makes use of other…
-
14, 14 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— 3. Features & Operating Condition 3.1. Brief Description 3.2. Operating Condition The device works like all slit lamps: Stereomicroscopic examination of the ey e under the slit light. Microscopic examination of the ocular fundus and posterior vitreou body (using h r uby ’ s lens). These devices are designed for use by ophtha…
-
16, 16 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— 4. Standard Components The instrument is delivered in package. Taking it out the package, make sure that none of the following parts is missing. A table top(N.B. the table top isn ’ t supplied with the slit lamp for twin table) on which are placed: A SMPS box(15) including the main sw…
-
2, 2 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— I MPORTANT NOTICE ! WARNING Potential electromagnetic or other interference between medical equipments and other devices being operated together in the same environmental may expert an adverse influence on f unctioning of the medical equipment. Non — medical equipments not in compliance with…
-
45, —————————————————— —————————— SLIT LAMP HS — 5 5 00 45 14. Service Information How to contact service: If there are any problems with the equipment, please f ollow the steps below: First of all, refer to the 10. Maintenance and 11. Troubleshooting sections ac cording to the problem that you are encountered. And then follow the suggested sequences . If the problem persists, please c ontact the local distribut…
-
9, —————————————————— —————————— SLIT LAMP HS — 5 5 00 9 UL60601 — 1 CAN/CSA C22.2 NO.601.1 MEDICAL EUIPMENT WITH RESPECT TO ELECTRIC SHOCK FIRE AND MECH ANICAL HAZ ARDS ONLY IN ACCO RD ANC E WITH UL 60601 — 1, AND C AN/CSA C22.2 NO.601.1 Disposal of your old appliance When this crossed — out wheeled bin symbol is attached to a product it means the product is covered …
-
15, —————————————————— —————————— SLIT LAMP HS — 5 5 00 15 ! CAUTION Because prolonged intense light exposure can damage the retina, the use of the device for ocular examination should not be unne cessarily prolonged, and the brightness setting should not exceed what is needed to provide cl visualization of the target structures. This device should be used with filters that…
-
36, Huvitz HS-5500 36 SLIT LAMP HS — 55 00 ——————- — —————————————— ——————— 11.3. Guidance and manufacturer ’ s declaration – electromagnetic immunity Immunity test IEC 60601 test level Complianc e level Electromagnetic environment — guidance Recommended separation distance The EUT is intended for use in the electromagnetic en…
-
3, —————————————————— —————————— SLIT LAMP HS — 5 5 00 3 HUVITZ reserves the right to make changes in its products or product specifications at any time and without prior notice, and is not required to update this documentation to reflect such changes. ©200 9 HUVITZ Co., Ltd. 689 — 3, Geumjeong — dong, Gunpo — si, Gyeonggi — do, 435 — 862, Republic of Korea All rights are reserved. …
- Manuals
- Brands
- Huvitz Manuals
- Microscope
- HS-5500
Manuals and User Guides for Huvitz HS-5500. We have 2 Huvitz HS-5500 manuals available for free PDF download: Manual, Operator’s Manual
Huvitz HS-5500 Operator’s Manual (48 pages)
SLIT LAMP MICROSCOPE
Brand: Huvitz
|
Category: Microscope
|
Size: 0.92 MB
Table of Contents
-
Table of Contents
4
-
1 Introduction
6
-
Indication for Use
6
-
Classification
6
-
Introduction
7
-
Safety Symbols
8
-
Environment Factors
10
-
Safety Precautions
12
-
-
-
2 Safety Information
7
-
3 Features & Operating Condition
14
-
Brief Description
14
-
Operating Condition
14
-
-
4 Standard Components
16
-
5 Accessories
17
-
6 Composition
18
-
7 Installation
23
-
Assembling the Instrument
23
-
-
8 Trial Operations
27
-
9 Main Features
28
-
10 Ordinary Maintenance
29
-
Halogen Projection Bulb
29
-
Protection Fuses Replacement
30
-
Cleaning & Disinfection
32
-
-
11 EMC Information
33
-
Guidance and Manufacturer’s Declaration — Electromagnetic Emissions
33
-
Guidance and Manufacturer’s Declaration — Electromagnetic Immunity
34
-
Guidance and Manufacturer’s Declaration — Electromagnetic Immunity
36
-
Recommended Separation Distances between Portable and Mobile RF
38
-
Communications Equipment and the EUT
38
-
Immunity and Compliance Level
39
-
Guidance and Manufacturer’s Declaration — Electromagnetic Immunity
40
-
-
12 Electric Diagram
42
-
13 Technical Specifications
43
-
14 Service Information
45
-
15 Particular Information
47
Advertisement
Huvitz HS-5500 Manual (72 pages)
SLIT LAMP MICROSCOPE / IMAGING SYSTEM
Brand: Huvitz
|
Category: Laboratory Equipment
|
Size: 5.03 MB
Table of Contents
-
Table of Contents
2
-
Information
3
-
Illumination System
7
-
Microscope
11
-
Installation of Joystick Driver
60
-
Trouble Shooting
68
Advertisement
Related Products
-
Huvitz HS-5000 5X
-
Huvitz HS-5000 2X
-
Huvitz HS-5000 3X
-
Huvitz HS-7000
-
Huvitz HRM-300
-
Huvitz HSZ-700
-
Huvitz HSZ-600
-
Huvitz HS-7500
-
Huvitz HS-5000
-
Huvitz HFC-1
Huvitz Categories
Medical Equipment
Measuring Instruments
Laboratory Equipment
Microscope
Projector
More Huvitz Manuals
-
Page 1
—————————————————— ——————————SLIT LAMP HS-5500 Operator’s Manual SLIT LAMP MICROSCOPE HS-5500… -
Page 2
The information in this publication has been carefully checked and is believed to be entirely accurate at the time of publication. HUVITZ assumes no responsibility, however, for possible errors o r omissions, or for any consequences resulting from the use o f the ormatio n contained herein. -
Page 3
—————————————————— ——————————SLIT LAMP HS-5500 HUVITZ reserves the right to make changes in its products or pro duct specificatio ns at any time and without prior notice, and is not required to update this documentatio n to reflect such changes. © 2009 HUVITZ Co ., Ltd. -
Page 4: Table Of Contents
SLIT LAMP HS- 5500——————- —————————————————————- Contents Introduction ………………….. 6 1.1. Indication for use ………………6. 1.2. Classification……………….. 6 Safety Infor mation………………..7 2.1. Introduction ………………..7 2.2. Safety Symbols ………………8 2.3. Environment factors…………….10 2.4. Safety Precautions……………… 12 Features & Operating Condit ion …………..14 3.1.
-
Page 5
—————————————————— ——————————SLIT LAMP HS-5500 10.1. Halogen Projection bulb …………….29 10.2. Protection fuses replacement…………..30 10.3. Cleaning & Disinfection …………….32 11. EMC Infor mation ………………..33 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions..33 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity ..34 11.3. -
Page 6: Introduction
Introduction 1.1. Indication for use (intended use) The SLIT LAMP, HS-5500 is intended for use in eye examination of the ant segments, from the cornea epithelium to the posterior capsule. It is used to aid in the diagnosis of diseases or trauma which affects the structural properties of the anterior eye segment.
-
Page 7: Safety Information
—————————————————— ——————————SLIT LAMP HS-5500 Safety Information 2.1. Introduction Safety is everyone’s responsibility. The safe use of this equipment is largely dependent upon the installer, user, operator, and maintainer. It is imperative that personnel study and become familiar with this entire manual before attempting to install use, clean, service or adjust this equipment and any associated accessories.
-
Page 8: Safety Symbols
SLIT LAMP HS- 5500——————- —————————————————————- 2.2. Safety Symbols The International Electro technical Commission (IEC) has established a set of symbols for medical electronic equipment which classify a connection or warn of any potential hazards. The classifications and symbols are shown below. This applies only to the instrument that has the certification symbol printed explicitly on the product label or sticker.
-
Page 9
—————————————————— ——————————SLIT LAMP HS-5500 M EDIC AL EUIP M ENT W ITH RESP EC T TO ELEC TRIC SHOCK UL6 06 01 FIRE M E CH ANIC AL H AZ ARDS CAN/CS A C22 .2 ONLY IN ACCO RD ANCE W ITH U L 6 0601- NO.601 .1… -
Page 10: Environment Factors
SLIT LAMP HS- 5500——————- —————————————————————- 2.3. Environment factors Avoid the following environments for operation or storage: W here the equipment is expo sed to water vapor. ’ t operate equipment with a wet hand. W here the equipment is expo sed to direct sunlight. W here the temperature changes extremely °…
-
Page 11
—————————————————— ——————————SLIT LAMP HS-5500 W here equipment is exposed to chemical material or explosive gas. Be careful not to be inserted dust, especially, metal. ’ disassemble the pro duct or o pen. We aren ’ respo nsible for it fo r nothing. -
Page 12: Safety Precautions
The equipment must be operated only by, or under direct supervision of a properly trained and qualified person. Modifications of this equipment may only be carried out by Huvitz’s service technicians or other authorized persons. Customer maintenance of this equipment may only be performed as stated in the User’s Manual and Service Manual.
-
Page 13
The manufacturer is not liable for damage caused by unauthorized tampering with the device(s). Such tampering will forfeit any rights to claim under warranty. This equipment may only be used together with accessories supplied by Huvitz’s. If the customer makes use of other accessories, use them only if their safe usability under technical safety aspects has been proved and confirmed by Huvitz or the manufacturer of the accessory. -
Page 14: Features & Operating Condition
SLIT LAMP HS- 5500——————- —————————————————————- Features & Operating Condition 3.1. Brief Description The device works like all slit lamps: Stereomicroscopic examination of the eye under the slit light. Microscopic examination of the ocular fundus and posterior vitreou body (using hruby’s lens). These devices are designed for use by ophthalmologists and optometrists (within the realms of their respective professions) for specific diagnostic procedures (bio- microscopic examination of the eye)
-
Page 15
—————————————————— ——————————SLIT LAMP HS-5500 CAUTION Because prolo nged intense light exposure can damage the retina, the use of the device for ocular examinatio n sho uld no t be unnecessarily prolonged, and the brightness setting sho uld not exceed what is needed to pro vide cl visualizatio n o f the target structures. -
Page 16: Standard Components
SLIT LAMP HS- 5500——————- —————————————————————- Standard Components The instrument is delivered in package. Taking it out the package, make sure that none of the following parts is missing. A table top(N.B. the table top isn’t supplied with the slit lamp for twin table) on which are placed: A SMPS box(15) including the main switch &…
-
Page 17: Accessories
—————————————————— ——————————SLIT LAMP HS-5500 Accessories The following standard accessories are provided with the instrument; protection cover(46) a setting rod(43) spare bulbs 12V 30W Halogen bulb (53) chin-rest paper(47) spare fuses 250Vac T2.0AL a breath screen(5) power cable [ F i g u r e 1 . Ac c e sso r i e s ]…
-
Page 18: Composition
SLIT LAMP HS- 5500——————- —————————————————————- Composition Fixation point Control lever for changing enlargement Removable eye-pieces Knob for clamping the breath screen Breath screen Knobs to change the slit length Connecting plug of the projector lamp Knurled ring for filters insertion Joystick for lateral, longitudinal and vertical movements(x y z) 10) Base with orthogonal movements 11) Shaped tabletop…
-
Page 19
—————————————————— ——————————SLIT LAMP HS-5500 26) Locking pins for chin rest paper 27) Chin rest 28) Knobs to change the slit width 29) Pointer for the eye positioning 30) Forehead Rest 31) Microscope Lamp socket 33) Knob to lock the base of the instrument… -
Page 20
SLIT LAMP HS- 5500——————- —————————————————————- 54) Screw hole cover 55) Prism 56) Capture connector ( For the image system) 57) Capture switch 58) Luminosity selector connector ( Connect the Luminosity selector to the SMPS) 59) Head rest module 60) Diffuser… -
Page 21
—————————————————— ——————————SLIT LAMP HS-5500 [ Figure 2. Composition I ]… -
Page 22
SLIT LAMP HS- 5500——————- —————————————————————- [ Figure 3. Composition ¥±]… -
Page 23: Installation
—————————————————— ——————————SLIT LAMP HS-5500 Installation NOTE The appliances are always supplied with excellent packaging to be able to stand up to all kinds of transport and standard sto rage co nditions. P lease co ntact the suppliers if any irregularities are fo und in the appliance due to transport after unpacking 7.1.
-
Page 24
SLIT LAMP HS- 5500——————- —————————————————————- Place the head rest module(59) and make sure that its holes fit together with Those of the table top. Tighten the screw with the screw driver [ Figure 5. Assembling the instrument I] Place the base with orthogonal movements on the guides situated on the upper part of the table top, checking that the wheels are in line. -
Page 25
—————————————————— ——————————SLIT LAMP HS-5500 Assemble an optical group of the slit projector (49) on the Base with orthogonal movements (10). Then tighten the Guide screw with the screw driver(-) Put the microscope(31) in the right position making sure that it is placed well in the stop(37);… -
Page 26
SLIT LAMP HS- 5500——————- —————————————————————- [ Figure 6. Assembling the instrument ¥±]… -
Page 27: Trial Operations
—————————————————— ——————————SLIT LAMP HS-5500 Trial Operations Assemble the chin-rest paper (47) on the chin-rest (27). Let the patient sit down comfortable with his chin on the chin-rest and his forehead against the forehead-rest. Lift or lower the chin-rest by moving the handle (25) so that the patient’s eyes are in line with the notches on the chin-rest (29).
-
Page 28: Main Features
SLIT LAMP HS- 5500——————- —————————————————————- Main Features Principal operative characteristics of the instrument: Observation without settling or tiring and rapid change of enlargements. Base with cross-wise movement (which can be stopped) commanded by a single joystick for all adjustments(x y z). Stereomicroscopical observation of the eye with enlargements 6x-10x-16x-25x- 40x(when use 12.5x eyepieces ) ¢ª…
-
Page 29: Ordinary Maintenance
—————————————————— ——————————SLIT LAMP HS-5500 10. Ordinary Maintenance WARNING The repairs illustrated below should all be carried out with the power cable disconnected from the main supply plug. P lease contact the suppliers for any other pro blems that cannot be resolved by the operatio ns des ibed below.
-
Page 30: Protection Fuses Replacement
SLIT LAMP HS- 5500——————- —————————————————————- Fasten the bulb with the Bulb fastening knob Make sure that the stems of the bulb are completely inserted; insert the plug in the main supply socket [ F ig ure 7. Re p la c e Ha lo g e n b ulb ] WARNING Do n ’…
-
Page 31
—————————————————— ——————————SLIT LAMP HS-5500 The protection fuses are placed on the back of the SMPS, and inserted power socket. Before doing anything else, disconnect the plu from the main supply socket Remove the burned-out fuses Substitute the fuses and check Replace the plug in the main supply socket. -
Page 32: Cleaning & Disinfection
SLIT LAMP HS- 5500——————- —————————————————————- 10.3. Cleaning & Disinfection To keep the device clean, apply clinical alcohol and cidex or cidex plus on a soft cloth and scrub the body and the probe once a month. Do not lacquer, thinner, ethylene, or the oxidizing substance.
-
Page 33: Emc Information
—————————————————— ——————————SLIT LAMP HS-5500 11. EMC Information 11.1. Guidance and manufacturer’s declaration – electromagnetic emissions The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 34: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.2. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 35
—————————————————— ——————————SLIT LAMP HS-5500 <5% U? U? ) EUT image intensifier be (<95% dip in for 5 s Powered from U? ) uninterruptible power for 5 s supply or a battery. Power frequency 3 A/m 3 A/m Power frequency (50/60Hz) -
Page 36: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.3. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an environment.
-
Page 37
—————————————————— ——————————SLIT LAMP HS-5500 and d is the recommended separation distance in meters (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey, Should be less than the compliance level in each frequency range. Interference may occur in the vicinity of… -
Page 38: Recommended Separation Distances Between Portable And Mobile Rf
SLIT LAMP HS- 5500——————- —————————————————————- 11.4. Recommended separation distances between portable and mobile RF communications equipment and the EUT This is intended for use in an electromagnetic environment which radiated RF disturbances are controlled. The customer or the user the EUT can help Prevent electromagnetic interference by maintaining a minimum nce between portable and mobile RF communications equipment (transmitters)
-
Page 39: Immunity And Compliance Level
—————————————————— ——————————SLIT LAMP HS-5500 11.5. Immunity and Compliance Level Immunity test IEC 60601 Test Actual Immunity Compliance Level Level Level Conducted RF 3Vrms 3Vrms 3Vrms IEC 61000-4-6 150kHz to 80MHz Radiated RF 3Vrms 3V/m 3V/m IEC 61000-4-3 80MHz to 2.5GHz…
-
Page 40: Guidance And Manufacturer’s Declaration — Electromagnetic Immunity
SLIT LAMP HS- 5500——————- —————————————————————- 11.6. Guidance and manufacturer’s declaration – electromagnetic immunity The EUT is intended for use in the electromagnetic environment specified below. The customer or the user of the EUT should assure that it is used in such an electromagnetic environment.
-
Page 41
—————————————————— ——————————SLIT LAMP HS-5500 NOTE 1) These guidelines may not apply in all situatio Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. NOTE 2) It is essential that the actual shielding effectiveness and filter attenuation of the shielded location be verified to assure that they meet the minimum specification. -
Page 42: Electric Diagram
SLIT LAMP HS- 5500——————- —————————————————————- 12. Electric Diagram…
-
Page 43: Technical Specifications
—————————————————— ——————————SLIT LAMP HS-5500 13. Technical Specifications M IC R O SC O P E — H S-55005x T ype G alilean conv erging bin ocular M agnification 5 p osition s rotatingdrum E y epiece 12.5x T otal m ag nification…
-
Page 44
SLIT LAMP HS- 5500——————- —————————————————————- BASE Vertical Movement Min. 28mm Longitudinal Movement Min. 78mm. Lateral Movement Min. 98mm Fine base Movement Min. 10mm Power supply 100~ 24 0 V AC 50/ 60HZ 2.0A Power consumption 70VA Instrument Voltage 12V DC Halogen Projection bulb 12V 30W Fixation point LED… -
Page 45: Service Information
Seri al No .: ’ If you can t contact with your local distributo r, you can directly get in touch with the service department of the HUVITZ using the pho ne number and the address written in the below table.
-
Page 46
SLIT LAMP HS- 5500——————- —————————————————————- How to Co ntact HUVITZ Co ., Ltd Wri te us at: : +82-31 442-8868 HUVITZ Co ., Ltd. F ax : +82 31-442-8619 Huvitz B/D, 68 9 3 Geumjeong dong URL http://www.huvi tz.com Gunpo… -
Page 47: Particular Information
—————————————————— ——————————SLIT LAMP HS-5500 15. Particular Information 15.1. Relative spectral output graph (1) Halogen Lamp (2) Fixat ion Lamp…
-
Page 48
SLIT LAMP HS- 5500——————- —————————————————————- Note: this graph be shown for the beam after it exists the instrument, when the instrument is operating at maximum light intensity and maximum aperture. CAUTION “CAUTION – The light emitted from this instrument is potentially hazardous.
Компания HUVITZ Co. Ltd. предоставляет широкий спектр диагностического оборудования и составляет серьезную конкуренцию другим компаниям в офтальмологической области.
Подробнее о товаре
Лампа щелевая HS-5500 предназначается для использования при обследовании переднего и заднего отрезков органа зрения, от роговичного эпителия вплоть до задней капсулы. Он применяется для диагностических целей в случае болезней или травм, которые повреждают задний сегмент глаза.
Поскольку в инструменте есть пятиступенчатый контроль приближения изображения и современная оптической технологии, при использовании лампы щелевой HS 5500 возможно получение хорошего разрешения и обширного поля обзора, а многообразные фильтры прибора приспособлены для большей части видов постановки диагноза, что дает возможность реализовывать наиболее точное обследование пациента.
Особенности Huvitz HS-5500
- Широчайший спектр увеличения в приборе (от шестикратного до увеличения в сорок раз) с легкостью варьируется посредством пятипозиционного переключателя барабанного типа. Управление оптикой микроскопа проходит легко и быстро.
- Тридцативаттная галогеновая лампа делает картинку яркой и контрастной.
- Микроскоп приборов от Huvitz серии HS создан по схеме Галилея, признанной а это мировой стандарт. Обеспечивается широкое поле зрения, реалистичное изображение и самая высокая точность.
- Особенно эргономичный джойстик превращает управление положением щели в легкий процесс без потери точности. Особая клавиша лампы щелевой HS 5500 удобно фиксирует джойстик, дабы легко закреплять изображение. Картинки могут быть сохранены одновременно, когда лампа щелевая HS-5500 соединена с каким-либо мультимедийным устройством вывода.
- Присутствие желтого фильтра, что может использоваться вместе с синим, — это нужно для проверки корректности посадки контактных линз.
- Специализированное ПО, предоставляемое в комплекте с камерой, позволяет очень просто получать, обрабатывать и архивировать данные.
Возможности щелевой лампы HS-5500
- Исследовать зрительные органы без фиксации в одной точке, а значит, без усталости пациента.
- Основание, двигающееся по 3-м взаимно перпендикулярным направлениям. Абсолютно все движения (по осям x, y и z) подконтрольны джойстику.
- Стереомикроскопическое обследование глаза с приближением 6х, 10х, 16х, 25х, 40х (когда используется окуляр 12.5х).
- Разворот проекционного луча в плоскости вертикали от 0° до 20°.
- Микроскопическое обследование задней части стекловидного тела и сетчатки (требуются линзы Хруби)
- Контактное исследование (с помощью линзы Гольдмана).
- Исследование глаза при флуоресцентном освещении и оценка размещения контактных линз.
- Измерения давления прибором Гольдмана.
- Замер диаметра роговицы, наложение контактных линз.
- Статистическое определение положения оси контактных линз посредством изменения наклонного угла щели по всем меридианам.