ET NICE WIDE INSTRUCTIONS 2018.001 Installer Instructions High Traffic, Battery Back-up Traffic Barrier www.niceforyou.com/za… -
Page 2: Site Preparation
Introduction. Page 3 Be Safe! Instructions, warnings and obligations. Page 4 Technical specifications. Page 5 Component identification and descriptions. Site preparation. Page 6 Pole lengths (limitations) and pole accessory kits. Page 7 Calculating the duty cycle. Page 7 Positioning the barrier. Page 8 Typical cabling requirements.
-
Page 3
8. All ET Nice (Pty) Ltd garage door operators are supplied with a sealed 15A safety plug on lead for use in an electrical code of practice approved plug point. Do not extend, modify or replace the plug lead unless duly qualified as an electrician. Before installing the unit, ensure the mains supply is switched off. -
Page 4: Technical Specifications
Before removing the battery from the system the household mains must be disconnected. In the case of the motor unit being removed and scrapped, the battery must be removed first. Technical specifications. TECHNICAL SPECIFICATIONS Technical Data WIDE M and WIDE L Primary power supply. 220 – 240Vac @ 50Hz – 60Hz. Peak power consumption. 240W Electrical class.
-
Page 5
1m lengths strips, 45x58x4000mm strips, 69x92x3150mm strips, 69x92x5150mm Wide M 4m 1 pc 8 lengths Wide L 5m 1 pc 10 lengths Wide L 6m 2 pcs… -
Page 6
Major service interval guide. Severity index Work impact considerations Wide M Wide L Jack-knife boom pole. High dust and sand environment. High salinity environment. Aluminium fence installed. Mobile pole support installed. Ambient temperature above 40 C or below 0 Operation regularly interrupted by safety beam circuit trigger. -
Page 7: Cabling Requirements
Cabling requirements. • Before mounting the operator ensure your cables and conduiting are in place to prevent any inconvenience at a later stage. • All 220Vac mains cabling and circuits need to be installed by a qualified electrician and signed off by a registered electrician. •…
-
Page 8: Installing The Cabinet
Installing the cabinet. Establish where the traffic barrier cabinet mounting position needs to be. If an concrete plinth already exists, skip to step If no concrete plinth is in place, continue on to step 02. Begin by digging a hole for the foundation plinth to be cast in.
-
Page 9
Access the cabinet by removing the lid screws (a) and then the lid (b). With the lid removed, slide the cabinet access panel up (c) and then pull it away from the cabinet (d) In the case of a previously prepared plinth, where the anchoring bolts were not cast into the concrete, do the following: Position the cabinet in the required positions. -
Page 10
Installing the boom pole. Before installing the pole mount, double check whether the application requires a left hand or right hand closing barrier. Top view — Top view — Factory default = LH Closing. Left hand Right hand closing closing If the site application requires a left hand closing configuration, complete the following 3 steps: Opening for boom pole at top. -
Page 11
5. Remove the tie-rod ends from the right hand side of the power arm. 4. Remove all tension from the springs by turning the turnbuckles anti-clockwise 6. Move the boom pole into the vertical open position. Lock the gearbox in this position. -
Page 12
Adjusting the end stops. -
Page 13
Electrical and electronic installation and setup. As a motorised operator vibrates when in use, it is strongly recommended that only multiple strand flexible cables be used. Before closing the unit, always remember to double check that all connections are securely made, that there are no stray strands flaring out that can short circuit against other adjacent connections or bared wires and that no cables will be pulled loose when the cover is replaced on the unit. -
Page 14
Wiring and termination of the control card. -
Page 15
Using the control card display and dashboard. The control unit is equipped with a LCD display and interactive keys for simplified programming and diagnostics. All setup, of the various features, requires that the control card dashboard be used. Below are the functions of each key on the dashboard. Navigate backward in menus, decrease Navigate forward in menus, increase values, indicate lefthand closing barrier… -
Page 16: Runtime Setup
Set Boom Type Display asks you to Press and release the button to select runtime select the barrier < Wide M > model. setup. Set BoomType Scroll < or > to select the Display scrolls < Wide L >…
-
Page 17
Selecting a safety level. Overload Setting This adjusts the force level, over and above the nominal — “Selected” mode — barrier resistance, needed to trigger the safety overload From Standby status — Standby routines. Level 1 being the most sensitive and 8 being the least sensitive. -
Page 18
BT Mode Setting Selecting a BT operating mode and adjusting the BT auto-close time. The factory default is Simplex mode. The factory default auto-close time is 20 seconds. The timer range is 1 – 254 seconds. PLEASE NOTE!! To select any of the automatic — “Selected”… -
Page 19: Receiver Setup
Receiver programming and setup. Receiver Setup Setting up a new user: — Quick learn method. The barrier can be in any position when performing this routine. — “Selected” mode — Please note that if an ET BLU MIX © transmitter is being used and From Standby status — Standby not all of the buttons have been set to the same format, then the…
-
Page 20
Receiver programming and setup. Setting up a new user: — Quick learn method. Receiver Setup (Corresponding 4 function learn option) — “Selected” mode — From Standby status The barrier can be in any position when performing this routine. — Standby Response Action Description… -
Page 21
Receiver programming and setup. Receiver Setup Setting up a new user: — Advanced learn method. The barrier can be in any position when performing this routine. — “Selected” mode — Please note that if an ET BLU MIX © transmitter is being used and From Standby status — Standby not all of the buttons have been set to the same format, then the… -
Page 22
Receiver programming and setup. Receiver Setup Erasing a single user from the memory. — “Selected” mode — From Standby status The barrier can be in any position when performing this routine. — Standby Response Action Description Display Buzzer Barrier To enter the program Programming menu menu. -
Page 23
Receiver programming and setup. Receiver Setup Master erasing all users from the memory. — “Selected” mode — From Standby status The barrier can be in any position when performing this routine. — Standby Response Action Description Display Buzzer Barrier To enter the program Programming menu menu. -
Page 24
Receiver programming and setup. Receiver Setup Diagnose remotes. The barrier can be in any position when performing this routine. — “Selected” mode — From Standby status This feature can be used to determine if there is 433.92MHz radio — Standby interference. -
Page 25
Receiver programming and setup. Receiver Setup Receiver information. — “Selected” mode — From Standby status The barrier can be in any position when performing this routine. — Standby Response Action Description Display Buzzer Barrier To enter the program Programming menu menu. -
Page 26
Traffic light — This option allows for timed traffic light switching between green and red. This control unit can be used with the NICE Blue-bus two wire devices like the Blue-bus safety beam Blue-bus Setup. products. This function must be run when adding or removing any Blue-bus devices to the system.
This manual is also suitable for:
Wide l
- Прост в установке
- Встроенный блок управления удобно расположен под верхней крышкой шлагбаума
- Программирование функций при помощи diр переключателей
- Разъем SM для подключения радиоприемников (SMXI, SMXIS, OXI, OXIBD, OXILR)
- Повышенная мощность и ресурс редуктора позволяют использовать шлагбаум на объектах с повышенной интенсивностью эксплуатации (до 300 циклов в час)
- Функция автоматического закрытия после проезда автомобиля (время настраивается)
- Возможно питание от аккумуляторной батареи PS324, устанавливаемой внутри корпуса тумбы шлагбаума (опция)
- Возможность скрытой инсталляции фотоэлементов внутри тумбы шлагбаума (исключает риск повреждения)
- Мощный редуктор допускает устанавливать на стрелу дополнительные аксессуары, такие как решетка WA13 и подвесная опора WA12
- Корпус выполнен из прочной оцинкованной стали
- Металлическое монтажное основание поставляется в комплекте
- Надежный механизм разблокировки редуктора
Параметр | Единица | Величина |
---|---|---|
Питание | Вольт пер.тока, 50Гц | 230 |
Питание двигателя | Вольт пост. тока | 24 |
Номинальный ток | A | 1.3 |
Мощность | Ватт | 300 |
Время открытия | Секунд | 3,5 |
Крутящий момент | Ньютон/м | 140 |
Интенсивность | циклов/час | 300 |
Класс защиты | IP | 44 |
Размеры | мм | 320х205х1000высота |
Вес | кг | 54 |
- Manuals
- Brands
- Nice Manuals
- Control Systems
- WIDEM
Manuals and User Guides for Nice WIDEM. We have 1 Nice WIDEM manual available for free PDF download: User, Installation And Safety Instructions
Nice WIDEM User, Installation And Safety Instructions (36 pages)
Electromechanical road barrier
Brand: Nice
|
Category: Control Systems
|
Size: 14.61 MB
Table of Contents
-
Ce Declaration of Conformity
2
-
Table of Contents
3
-
-
General Warnings: Safety — Installation — Use
4
-
A — Special Warnings in Relation to European Directives Applicable to the Product
5
-
B — Installation Criteria and Special Warnings in Connection with Essential Requirements
5
-
-
1 Product Description and Intended Use
6
-
2 — Operating Limits
7
-
Product Durability
7
-
-
3 Installation
8
-
4 Electrical Connections
18
-
Types of Electrical Cables
19
-
Electrical Cable Connections
19
-
-
5 Starting the Automation and Checking the Connections
21
-
Hooking the Automation up to the Mains
21
-
-
6 Testing and Commissioning
23
-
Testing
23
-
Commissioning
24
-
-
7 Programming
25
-
Control Unit
25
-
Programmable Functions
25
-
-
8 Further Details
27
-
Connecting a Radio Receiver
27
-
Power for External Devices
27
-
Connecting Boom Lights
28
-
Connecting Photocells Within the Barrier Mechanism
28
-
Connecting the Back-Up Battery
29
-
-
9 Product Disposal
30
-
10 Basic Troubleshooting
30
-
11 Technical Specifications
31
-
MAINTENANCE SCHEDULE (Detachable Insert)
33
-
User Manual (End User Version)
35
Advertisement
Advertisement
Related Products
-
Nice WIDE M
-
Nice WIDEMI
-
Nice WIDEM/V1
-
Nice WIDEMI/V1
-
Nice WIDE L
-
Nice WIDES
-
Nice WIDESI
-
Nice WIDEL
-
Nice WIDELI
-
Nice WIDES/V1
Nice Categories
Gate Opener
Engine
Control Unit
Garage Door Opener
Receiver
More Nice Manuals
ВНИМАНИЕ! Цены, указанные на сайте, действуют только при оформлении заказа на сайте. Система скидок, акции, бонусы не применяются при заказе по телефону. Менеджеры отдела продаж выставляют счета и предложения на основании розничного прайс-листа отдела продаж. Информация, размещенная на сайте nice.msk.ru, носит информационный характер и не является публичной офертой, определяемой положениями Статьи 437 (2) ГК РФ
Производитель: NICE
Модель: WIDEM5BDKIT2
Артикул: WIDEM5BDKIT2
Наличие: Нет в наличии
Поставляется по запросу. Возможность поставки уточняйте у менеджера.
Отправить запрос:
Комплект шлагбаума NICE WIDEM5BDKIT2 для проезда шириной 5 метров.
Состав комплекта:
- Тумба WideM — 1 шт;
- рейка шлагбаумная XBA19-5RU (45х58х5200 мм) — 1 шт;
- наклейки светоотражающие NK1 — 1 шт;
- демпфер XBA13-10RU — 1шт;
- приемник OXIBD — 1 шт;
- фотоэлементы EPM — 1 пара;
- лампа ELDC — 1 шт;
NICE WIDEM — тумба шлагбаума предназначена для проездов шириной до 4 метров. Напряжение питания двигателя 24 В. Скорость открывания 3,5 м/с, интенсивность 300 циклов/час. Габаритные размеры тумбы 1000х320х205 мм.
Удобный для установщика:
- Простая установка и настройка;
- Монтажное основание поставляется в комплекте;
- Встроенный блок управления;
- Программирование функций при помощи diр-переключателей;
- Разъем SM для подключения радиоприемников (SMXI, SMXIS, DXI).
Функциональный для пользователя:
- Программируемое время автоматического закрытия;
- Автоматическое закрытие после срабатывания фотоэлементов;
- Резервное питание от аккумуляторной батареи PS324, устанавливаемой внутри корпуса тумбы шлагбаума (опция);
- Возможность установки фотоэлементов внутри корпуса шлагбаума
- Более мощный редуктор позволяет использовать дополнительные аксессуары для установки на стрелу (решетка WA 13 и подвесная опора WA 12)
Надежный при эксплуатации:
- Прочный корпус из оцинкованной окрашенной стали;
- Удобный и защищенный механизм разблокировки.
NICE XBA19-5RU — Рейка шлагбаумная 45x58x5200мм. Стрела из окрашенного аллюминия.
Характеристики NICE WIDEM
- Тумба шлагбаума
- Питание, Вольт пер.тока, 50Гц: 230
- Питание двигателя, Вольт пост. тока: 24
- Номинальный ток, А: 1.3
- Мощность, Ватт: 300
- Время открытия, Секунд: 3,5
- Крутящий момент, Ньютон/м: 140
- Интенсивность, циклов/час: 300
- Класс защиты, IP: 44
- Рабочая температура, °C мин/макс: -20 / +50
- Размеры, мм: 320х205х1000высота
- Вес, кг: 54
Написать отзыв