    Enter Setup 2D Barcode Scanner User Manual Version: v2.0 Modification date: 2019.5.11 Version change information V2.0 2019-5-5 1. The User Manual only for 2D Barcode Scanner Exit Setup…
  • Page 3: Table Of Contents

    Enter Setup Table of Contents Chapter 1 Factory Defaults……………….3 Restore All Factory Defaults…………….3 Save as Custom Defaults…………….. 3 Restore All Custom Defaults…………….3 Chapter 2 Product Information…………….4 Chapter 3Communication Interface…………..5 USB-KBW………………….5 USB-COM………………….5 TTL/RS232…………………..6-8 Chapter 4 Scan Mode………………..9 1. Manual Reading Mode…………….9-12 2.

  • Page 4
    Enter Setup Chapter 8 Symbologies edding and enable/disable configuration….44 Enable All Symbologies…………….44 Enable 1D symbologies…………….44 Enable 2D symbologies…………….44 EAN-8………………….45-47 EAN-13………………….47-50 UPC-E………………….51-54 UPC-A………………….54-56 CODE 128………………….57 GS1-128………………….58 AIM-128………………….59 ISBT-128………………….60 Interleaved 2 of 5………………61-62 China Post 2 of 5………………63-64 Matrix 2 of 5………………..65-66 Industrial 2 of 5……………….
  • Page 5: Chapter 1 Factory Defaults

    Enter Setup Chapter 1: Factory Defaults Scan“Restore All Factory Defaults”Code , Restores all Settings to factory default , Setup code include“ * ”is the factory default setting. Restore All Factory Defaults Users can set it according to the corresponding requirements, then scan and save the current default as the custom defaults.

  • Page 6: Chapter 2 Product Information

    Enter Setup Chapter 2: Product Information Query Firmware Version Query Manufacturer Information Query Model Number Query products Serial Number Query Production Batch Query Production date Exit Setup…

  • Page 7: Chapter 3Communication Interface

    Enter Setup Chapter 3: Communication Interface When connect USB,scan“USB-KBW”code to configure for standard keyboard output * USB-KBW When connect USB,scan“USB-COM”code to configure for virtual serial output USB-COM When connect Serial Line,scan“TTL/RS232”code to configure for serial output,Serial port related default configuration is:9600bps,8bits,No parity bit,1 stop bit. TTL/RS 232 Exit Setup…

  • Page 8
    Enter Setup TTL232/RS232 1200 bps 2400 bps 4800 bps * 9600bps 19200 bps 38400 bps Exit Setup…
  • Page 9
    Enter Setup 57600 bps 115200 bps 7-N-1 7-N-2 * 8-N-1 7-E-1 7-E-2 Exit Setup…
  • Page 10
    Enter Setup 8-E-1 7-O-1 7-O-2 8-O-1 Exit Setup…
  • Page 11: Chapter 4 Scan Mode

    Enter Setup Chapter4: Scan Mode 1、 Manual Reading Mode Manual mode-keep buttom down, press the buttib to trigger the reading, and release the button to end the reading. If the reading time is successful or the reading time exceeds the single reading time, the reading will end.

  • Page 12
    Enter Setup Set reading time 1000ms Set reading time 2000ms Set reading time 3000ms *Set reading time6000ms Set reading time 10,000ms Set One Reading Time ( 100ms ~ 25,500ms) * Only Read One Code Exit Setup…
  • Page 13
    Enter Setup Enable Batch Reding code Max 2 codes Max 5 codes Max 10 codes Max 16 codes * Max 32 codes Set any number Exit Setup…
  • Page 14
    Enter Setup After jumping from other modes to manual mode, it is allowed to return to the original mode after a period of off time. Read the following setting code to select different delays. default time is 4000ms After off 500ms to return After off 1000ms to return After off 2000ms to return After of 3000ms to return…
  • Page 15: Continuous Mode

    Enter Setup 2、Continuous Scanning Mode Continuous Scanning Mode, no manual trigger required, When reading succes or after end of single code reading time, will automatically start the next reading.( Continuous scanning period can switch to manual mode by press the button temporary.) Continuous Mode *Temporary switching Manual mode Do Not Temporary switching Manual Mode…

  • Page 16
    Enter Setup Set reading time 3,000ms * Set reading time 6,000ms Set reading time 10,000ms Set reading time 20,000ms Set Single Reading Time(100ms ~ 25,500ms) Read interval setting The space time between two readings, that is, after the last reading (whether the reading is successful or not), there is no reading within the setting space time, and the next reading is not conducted until the end of the space time.
  • Page 17
    Enter Setup Set Space time 100ms Set Space time 200ms * Set Space time 500ms Set Space time 1,000ms Set Space time 2,000ms Set Space time(0ms ~ 4,000ms) Exit Setup…
  • Page 18
    Enter Setup The same bar code reading delay time In order to avoid repeated reading of the same barcode, when reading the same barcode again, only when the space time is longer than the delay time, can reading be allowed. Set Same Code Delay time 0ms Set Same Code Delay time 500ms *Set Same Code Delay time 1000ms…
  • Page 19
    Enter Setup Set Same Code Delay time 10,000ms Set Same Code Delay time(0ms ~ 10,000ms) Exit Setup…
  • Page 20: Automatic Mode

    Enter Setup 3、Automatic Scanning Mode In Automatic Scanning Mode, No manual trigger required, The sensor will automatically detect the surrounding environment. When the scene changes, it will automatically trigger reading. When reading is successful or exceeds one reading time, reading will end.Whether the last reading is successful or not, the detection state will be re-entered.

  • Page 21
    Enter Setup In order to avoid repeated reading of the same barcode, when reading the same barcode again, only when the space time is longer than the delay time, can reading be allowed. Set Same Code Delay time 500ms * Set Same Code Delay time 1,000ms Set Same Code Delay time 2,000ms Set Same Code Delay time 3,000ms Set Same Code Delay time 10,000ms…
  • Page 22
    Enter Setup Set Image time 100ms Set Image time 200ms Set Image time 500ms *Set Image time 1,000ms Set Image time(100ms ~ 3,000ms) Sensitivity Detects the degree of change in the scene. * High Sensitivity Exit Setup…
  • Page 23
    Enter Setup Medium Sensitivity Low Sensitivity Set Single Reading Time In Automatic Scanning Mode,The maximum amount of time that continuous recognition is allowed before successful reading. Set Reading time 1,000ms *Set Reading time 2,000ms Set Reading time 3,000ms Set Reading time 5,000ms Exit Setup…
  • Page 24
    Enter Setup Set Reading time 10,000ms Set Reading time 20,000ms Set Reading time(100ms ~ 25,500ms) Exit Setup…
  • Page 25: Chapter 5 Illumination And Aiming

    Enter Setup Chapter 5: Illumination and Aiming 1、Illumination Illuminating light provide illumination aids for reading,Improve reading performance and adaptability to weak ambient light. *Reading On 2、Aiming Aiming light can help users find the best reading area when reading. *Reading On Exit Setup…

  • Page 26: Chapter 6 Output Remind

    Enter Setup Charpter 6:Output Remind The Indicator does not flash * The indicator flash 1 time The indicator flash 2 times The indicator flash 3 times The indicator flash 4 times The Indicator continue time100ms Exit Setup…

  • Page 27
    Enter Setup The Indicator continue time 200ms The Indicator continue time500ms The Indicator continue time 1000ms The Indicator continue time1500ms The Indicator continue time 2000ms The Indicator Interval time 100ms The Indicator Interval time 200ms Exit Setup…
  • Page 28: Read Beep

    Enter Setup 2、Read Beep (1)All Indicator Disable Power on Beep * Enable Power on Beep Disable Setting Code Beep * Enable Setting Code Beep Exit Setup…

  • Page 29: (2)Successful Sound Remind

    Enter Setup Medium Loud (2)Successful sound remind * Use Sound remind Do not use Sound remind *Sound remind 1 time Sound remind 2 times Exit Setup…

  • Page 30: (3)Beep Frequency

    Enter Setup Set sound remind times(1~5) (3)Beep Frequency Set Beep Frequency 1600Hz *Set Beep Frequency2700Hz Set Beep Frequency 3200Hz Set Beep Frequency4200Hz Good Read Beep Frequency(100 ~ 20,000Hz) Exit Setup…

  • Page 31: (4)Good Read Beep Time

    Enter Setup (4)Good Read Beep time Set Beep time 50ms * Set Beep time100ms Set Beep time 150ms Set Beep time 200ms Set Beep time 250ms Set Beep time 300ms Exit Setup…

  • Page 32: Decoding Status Remind

    Enter Setup 3、Decode status remind Enable NG(NoRead) *Disable NG(NoRead) Set NoRead information (1-16bytes) 4、Keyboard language United States Belgium Exit Setup…

  • Page 33
    Enter Setup Brazil Canada French Czech Denmark Finland France Germany Exit Setup…
  • Page 34
    Enter Setup Greek Hungary Israel Italy Latin America Dutch Netherlands Norway Exit Setup…
  • Page 35
    Enter Setup Poland Portugal Romania Russia Slovakia Spain Exit Setup…
  • Page 36
    Enter Setup Sweden Switzerland German Turkey F Turkey Q Unite Kingdom Japan ASCII Italian 14 Exit Setup…
  • Page 37: Set Virtual Keyboard

    Enter Setup 5、Set Virtual Keyboard Output Characters ALT+Numeric keys * Output characters using a large keyboard Use «Ctrl» to combine output control characters *Original output control character Enable Small keypad * Disable Small keypad 6、Capslock Keyboard letter conver, in the output of the barcode with letter content, you can set the code to make the output result is all to Upper Case or Lower Case.

  • Page 38: Data Encoding Format

    Enter Setup * No Case Conversion Conver All to Upper Case Conver All to Lower Case Letter case interchange Using Shift to unblock uppercase locking Using Capslock to unblock uppercase locking 7、Data encoding format To enable the host to print Chinese data in the specified encoding format, you can set it by reading «data encoding format»…

  • Page 39: Vat Invoice Automatic Identification Output Function

    Enter Setup GBK Chinese direct transmission GBK-Unicode Chinese direct transmission BIG5 Chinese direct transmission BIG5-Unicode direct transmission *Disable Chinese direct transmission 8、VAT invoice automatic identification output function * on Exit Setup…

  • Page 40: Image Flipping

    Enter Setup 9、 Image Flipping (Mirror Image) *Do Not Flip Flip Horizontally & Vertically Flip Vertically Flip Horizontally Exit Setup…

  • Page 41: Chapter 7 Data Editing

    Enter Setup Charpter 7: Data editing 1、Data editing Enable/Disable *Enable Data editing Disable Data editing 2、Symbol name display Enable Symbol name display Disable Symbol name display 3、Symbol length display Enable Symbol length output Exit Setup…

  • Page 42: Code Id

    Enter Setup Disable Symbol length output 4、CODE ID Users can identify different barcode types by Code ID. The corresponding Code ID of each barcode type can be modified by themselves (the corresponding setting Code can be found in the enable/disable configuration of barcode type). Code ID USES one character to identify , see appendix 3.

  • Page 43: Terminal Character

    Enter Setup * Disable AIM ID output 5、Terminal Charater *Enable Terminal Charater Disable Terminal Charater Do Not Add Terminal Character Set Terminal CR Set Terminal CR+LF Exit Setup…

  • Page 44: Prefix/Suffix Setting

    Enter Setup Set Terminal TAB Set Terminal CR+CR Set Terminal CR+LF+CR+LF Set Terminator Character (1-8 bytes) 6、Prefix/Suffix Setting Prefix/suffix is a user-defined modified charater string before or after decoding information, which can be added by scanning «Enable prefix» or «Enable suffix» setting code. Set prefix/suffix, scan setting codes of «set prefix»…

  • Page 45
    Enter Setup *Disable Prefix Enable Prefix(1~16bytes) *Disable Suffix Enable Suffix Enable Suffix(1~16bytes) Exit Setup…
  • Page 46: Chapter 8 Symbologies Edding And Enable/Disable Configuration

    Enter Setup Charpter8:Symbologies edding and enable/disableconfiguration Disable All Symbologies Enable All Symbologies Disable 1D Symbologies Enable 1D Symbologies Disable 2D Symbologies Enable 2D Symbologies Exit Setup…

  • Page 47: Ean-8

    Enter Setup EAN-8 * Enable EAN-8 Disable EAN-8 Do Not Transmit Code 11 Check Character *Transmit Code 11 Check Character Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 48: Ean-13

    Enter Setup Convert EAN-8 to EAN-13 Do not Convert EAN-8 to EAN-13 Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Exit Setup…

  • Page 49
    Enter Setup Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter EAN-13 Enable EAN-13 Disable EAN-13 Do Not Transmit Check Character After Verification Exit Setup…
  • Page 50
    Enter Setup Transmit Check Character After Verification On ISBN/ISSN translation Off ISBN/ISSN translation 10 Digit ISBN 13 Digit ISBN Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 51
    Enter Setup Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Exit Setup…
  • Page 52
    Enter Setup Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter Exit Setup…
  • Page 53: Upc-E

    Enter Setup UPC-E * Enable UPC-E Disable UPC-E Do Not Transmit Code 11 Check Character * Transmit Code 11 Check Character Enable UPC-E1 * UPC-E1: Disable UPC-E1 Set No.1 Code ID Exit Setup…

  • Page 54
    Enter Setup Set No.2 Code ID Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Do Not Require Add-On Code Exit Setup…
  • Page 55
    Enter Setup Add Delimiter before the Add-on Code Do not Delimiter Add US country Code 0 Do Not add Country code System Character Do Not system Character Convert UPC-E1 to UPC-A Exit Setup…
  • Page 56: Upc-A

    Enter Setup Do Not Convert UPC-A UPC-A *Enable UPC-A Disable UPC-A Do Not Transmit Check Character After Verification Transmit Check Character After Verification Enable 2-Digit Add on code Exit Setup…

  • Page 57
    Enter Setup Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter Exit Setup…
  • Page 58
    Enter Setup Set No.1 Code ID Set No.2 Code ID Add US country Code 0 Do Not add Country code System Character Do Not system Character Exit Setup…
  • Page 59: Code 128

    Enter Setup Code 128 * Enable Code 128 Disable Code 128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 60: Gs1-128

    Enter Setup GS1-128 *Enable GS1-128 Disable GS1-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 61: Aim-128

    Enter Setup AIM-128 *Enable AIM-128 Disable AIM-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.1 Code ID Exit Setup…

  • Page 62: Isbt-128

    Enter Setup ISBT-128 *Enable ISBT-128 Disable ISBT-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 63: Interleaved 2 Of 5

    Enter Setup Interleaved 2 of 5 *Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID *Disable Exit Setup…

  • Page 64
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 65: China Post 2 Of 5

    Enter Setup China Post 2 of 5 Transmit Check Character After Verification *Disable Code 2 of 5 China Post Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 66
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 67: Matrix 2 Of 5

    Enter Setup Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 68
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 69: Industrial 2 Of 5

    Enter Setup Industrial 2 of 5 Enable Code 2 of 5 Industrial Disable code 2 of 5 industrial Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 70
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 71: Iata 2 Of 5

    Enter Setup IATA 2 of 5 Enable Code 2 of 5 IATA *Disable code 2 of 5 IATA Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 72
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 73: Itf-14

    Enter Setup ITF-14 Enable ITF-14 * Disable ITF-14 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 74
    Enter Setup DP-12 Enable DP-12 * Disable DP-12 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 75: Dp14

    Enter Setup DP-14 Enable DP-14 * Disable DP-14 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 76: Msi

    Enter Setup Enable MSI * Disable MSI Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 77
    Enter Setup Check Character Verification *One Check Character, No output One Check Character Input Two Check Characters, MOD10/MOD10 No output Two Check Characters, MOD10/MOD10 Input Two Check Characters, MOD10/MOD11 No output Two Check Characters, MOD10/MOD11 Input Disable Exit Setup…
  • Page 78: Code11

    Enter Setup Code 11 Enable Code 11 * Disable Code 11 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set the Minimum Length Set the Maximum Length Set No.1 Code ID Exit Setup…

  • Page 79: Code 39

    Enter Setup Set No.2 Code ID Code 39 *Enable Code 39 Disable Code 39 Transmit Start/Stop Character Do Not Transmit Start/Stop Character Enable Code 39 Full ASCII Exit Setup…

  • Page 80
    Enter Setup Disable Code 39 Full ASCI Set the Minimum Length Set the Maximum Length * Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Exit Setup…
  • Page 81: Code 32

    Enter Setup Set No.2 Code ID Code 32 Enable Code 32 * Disable Code 32 *Enable Code 32 Prefix“A” Disable Code32 Prefix “A” Exit Setup…

  • Page 82: Code 93

    Enter Setup Code 93 * Enable Code 93 Disable Code 93 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 83: Codabar

    Enter Setup Codabar *Enable Codabar Disable Codabar Set the Minimum Length Set the Maximum Length Transmit Start/Stop Character Do Not Transmit Start/Stop Character Exit Setup…

  • Page 84
    Enter Setup Set No.1 Code ID Set No.2 Code ID Check Character Verification * Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 85
    Enter Setup Start/Stop Character * ABCD/ABCD ABCD/TN*E abcd/abcd abcd/tn*e Exit Setup…
  • Page 86: Plessey

    Enter Setup Plessey Enable Plessey * Disable Plessey Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.1 Code ID * Disable Exit Setup…

  • Page 87: Rss-14

    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verificatio RSS-14 * Enable RSS-14 Disable RSS-14 * Transmit Application Identifier “01” Do Not Transmit Application Identifier Exit Setup…

  • Page 88: Rss-Limited

    Enter Setup Set No.1 Code ID Set No.2 Code ID RSS-Limited *Enable RSS-Limited Disable RSS-Limited * Transmit Application Identifier “01” Do Not Transmit Application Identifier Exit Setup…

  • Page 89: Pdf-417

    Enter Setup Set No.1 Code ID Set No.2 Code ID PDF-417 * Enable PDF417 Disable PDF417 Set the Minimum Length Set the Maximum Length Exit Setup…

  • Page 90
    Enter Setup Set No.1 Code ID Set No.2 Code ID *Allowable structural connection Do Not allowable structural connection Exit Setup…
  • Page 91: Qr Code

    Enter Setup QR Code * Enable QR Code Disable QR Code Set the Minimum Length Set the Maximum Length *Allowable structural connection Do Not allowable structural connection *Read mirror symbol Exit Setup…

  • Page 92
    Enter Setup Do not read mirror symbol Set No.1 Code ID 、 Set No.2 Code ID Enable OR code *Disable QR code Exit Setup…
  • Page 93: Data Matrix

    Enter Setup Data Matrix *Enable Data matrix Disable Data matrix Set the Minimum Length Set the Maximum Length *Enable Rectangular Barcode Disable Rectangular Barcode *Enable Inverse code Exit Setup…

  • Page 94
    Enter Setup Disable inverse code *Read mirror symbol Do not read mirror symbol *Allowable structural connection Do Not allowable structural connection Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 95: Aztec Code

    Enter Setup Aztec Code *Enable Aztec Disable Aztec Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 96: Maxicode

    Enter Setup Maxicode Enable Maxicode *Disable Maxicode Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 97: Appendix 1:Set Digital Code

    Enter Setup Appendix 1 Digit Barcodes Save Cancel Reset Exit Setup…

  • Page 98: Appendix 2 Ascii Table

    Enter Setup Appendix 2 ASCII Table Scanni Scanni Keybo Scanni Keybo Keyboard value value value value value value 1000 Null 1043 1086 1001 Keypad Enter 1044 1087 1002 Caps lock 1045 1088 1003 Right Arrow 1046 1089 1004 Up Arrow 1047 1090 1005…

  • Page 99
    Enter Setup 1032 Space 1075 1118 1033 1076 1119 1034 “ 1077 1120 1035 1078 1121 1036 1079 1122 1037 1080 1123 1038 & 1081 1124 1039 ‘ 1082 1125 1040 1083 1126 1041 1084 1042 1085 Exit Setup…
  • Page 100: Ascii Table 3 Defaults Table

    Enter Setup ASCII Table 3 Defaults Table Symbol type Code ID Character Decimal value Hexadecimal value Code 128 GS1-128 Code 39 EAN-8 EAN-13 UPC-E UPC-A Interleaved 2 of 5 ITF-14 Codabar Plessey Matrix 2 of 5 Industrial 2 of 5 IATA 2 of 5 Chinese Post 2 of 5 DP12…

  • Page 2
    Enter Setup 2D Barcode Scanner User Manual Version: v2.0 Modification date: 2019.5.11 Version change information V2.0 2019-5-5 1. The User Manual only for 2D Barcode Scanner Exit Setup…
  • Page 3: Table Of Contents

    Enter Setup Table of Contents Chapter 1 Factory Defaults……………….3 Restore All Factory Defaults…………….3 Save as Custom Defaults…………….. 3 Restore All Custom Defaults…………….3 Chapter 2 Product Information…………….4 Chapter 3Communication Interface…………..5 USB-KBW………………….5 USB-COM………………….5 TTL/RS232…………………..6-8 Chapter 4 Scan Mode………………..9 1. Manual Reading Mode…………….9-12 2.

  • Page 4
    Enter Setup Chapter 8 Symbologies edding and enable/disable configuration….44 Enable All Symbologies…………….44 Enable 1D symbologies…………….44 Enable 2D symbologies…………….44 EAN-8………………….45-47 EAN-13………………….47-50 UPC-E………………….51-54 UPC-A………………….54-56 CODE 128………………….57 GS1-128………………….58 AIM-128………………….59 ISBT-128………………….60 Interleaved 2 of 5………………61-62 China Post 2 of 5………………63-64 Matrix 2 of 5………………..65-66 Industrial 2 of 5……………….
  • Page 5: Chapter 1 Factory Defaults

    Enter Setup Chapter 1: Factory Defaults Scan“Restore All Factory Defaults”Code , Restores all Settings to factory default , Setup code include“ * ”is the factory default setting. Restore All Factory Defaults Users can set it according to the corresponding requirements, then scan and save the current default as the custom defaults.

  • Page 6: Chapter 2 Product Information

    Enter Setup Chapter 2: Product Information Query Firmware Version Query Manufacturer Information Query Model Number Query products Serial Number Query Production Batch Query Production date Exit Setup…

  • Page 7: Chapter 3Communication Interface

    Enter Setup Chapter 3: Communication Interface When connect USB,scan“USB-KBW”code to configure for standard keyboard output * USB-KBW When connect USB,scan“USB-COM”code to configure for virtual serial output USB-COM When connect Serial Line,scan“TTL/RS232”code to configure for serial output,Serial port related default configuration is:9600bps,8bits,No parity bit,1 stop bit. TTL/RS 232 Exit Setup…

  • Page 8
    Enter Setup TTL232/RS232 1200 bps 2400 bps 4800 bps * 9600bps 19200 bps 38400 bps Exit Setup…
  • Page 9
    Enter Setup 57600 bps 115200 bps 7-N-1 7-N-2 * 8-N-1 7-E-1 7-E-2 Exit Setup…
  • Page 10
    Enter Setup 8-E-1 7-O-1 7-O-2 8-O-1 Exit Setup…
  • Page 11: Chapter 4 Scan Mode

    Enter Setup Chapter4: Scan Mode 1、 Manual Reading Mode Manual mode-keep buttom down, press the buttib to trigger the reading, and release the button to end the reading. If the reading time is successful or the reading time exceeds the single reading time, the reading will end.

  • Page 12
    Enter Setup Set reading time 1000ms Set reading time 2000ms Set reading time 3000ms *Set reading time6000ms Set reading time 10,000ms Set One Reading Time ( 100ms ~ 25,500ms) * Only Read One Code Exit Setup…
  • Page 13
    Enter Setup Enable Batch Reding code Max 2 codes Max 5 codes Max 10 codes Max 16 codes * Max 32 codes Set any number Exit Setup…
  • Page 14
    Enter Setup After jumping from other modes to manual mode, it is allowed to return to the original mode after a period of off time. Read the following setting code to select different delays. default time is 4000ms After off 500ms to return After off 1000ms to return After off 2000ms to return After of 3000ms to return…
  • Page 15: Continuous Mode

    Enter Setup 2、Continuous Scanning Mode Continuous Scanning Mode, no manual trigger required, When reading succes or after end of single code reading time, will automatically start the next reading.( Continuous scanning period can switch to manual mode by press the button temporary.) Continuous Mode *Temporary switching Manual mode Do Not Temporary switching Manual Mode…

  • Page 16
    Enter Setup Set reading time 3,000ms * Set reading time 6,000ms Set reading time 10,000ms Set reading time 20,000ms Set Single Reading Time(100ms ~ 25,500ms) Read interval setting The space time between two readings, that is, after the last reading (whether the reading is successful or not), there is no reading within the setting space time, and the next reading is not conducted until the end of the space time.
  • Page 17
    Enter Setup Set Space time 100ms Set Space time 200ms * Set Space time 500ms Set Space time 1,000ms Set Space time 2,000ms Set Space time(0ms ~ 4,000ms) Exit Setup…
  • Page 18
    Enter Setup The same bar code reading delay time In order to avoid repeated reading of the same barcode, when reading the same barcode again, only when the space time is longer than the delay time, can reading be allowed. Set Same Code Delay time 0ms Set Same Code Delay time 500ms *Set Same Code Delay time 1000ms…
  • Page 19
    Enter Setup Set Same Code Delay time 10,000ms Set Same Code Delay time(0ms ~ 10,000ms) Exit Setup…
  • Page 20: Automatic Mode

    Enter Setup 3、Automatic Scanning Mode In Automatic Scanning Mode, No manual trigger required, The sensor will automatically detect the surrounding environment. When the scene changes, it will automatically trigger reading. When reading is successful or exceeds one reading time, reading will end.Whether the last reading is successful or not, the detection state will be re-entered.

  • Page 21
    Enter Setup In order to avoid repeated reading of the same barcode, when reading the same barcode again, only when the space time is longer than the delay time, can reading be allowed. Set Same Code Delay time 500ms * Set Same Code Delay time 1,000ms Set Same Code Delay time 2,000ms Set Same Code Delay time 3,000ms Set Same Code Delay time 10,000ms…
  • Page 22
    Enter Setup Set Image time 100ms Set Image time 200ms Set Image time 500ms *Set Image time 1,000ms Set Image time(100ms ~ 3,000ms) Sensitivity Detects the degree of change in the scene. * High Sensitivity Exit Setup…
  • Page 23
    Enter Setup Medium Sensitivity Low Sensitivity Set Single Reading Time In Automatic Scanning Mode,The maximum amount of time that continuous recognition is allowed before successful reading. Set Reading time 1,000ms *Set Reading time 2,000ms Set Reading time 3,000ms Set Reading time 5,000ms Exit Setup…
  • Page 24
    Enter Setup Set Reading time 10,000ms Set Reading time 20,000ms Set Reading time(100ms ~ 25,500ms) Exit Setup…
  • Page 25: Chapter 5 Illumination And Aiming

    Enter Setup Chapter 5: Illumination and Aiming 1、Illumination Illuminating light provide illumination aids for reading,Improve reading performance and adaptability to weak ambient light. *Reading On 2、Aiming Aiming light can help users find the best reading area when reading. *Reading On Exit Setup…

  • Page 26: Chapter 6 Output Remind

    Enter Setup Charpter 6:Output Remind The Indicator does not flash * The indicator flash 1 time The indicator flash 2 times The indicator flash 3 times The indicator flash 4 times The Indicator continue time100ms Exit Setup…

  • Page 27
    Enter Setup The Indicator continue time 200ms The Indicator continue time500ms The Indicator continue time 1000ms The Indicator continue time1500ms The Indicator continue time 2000ms The Indicator Interval time 100ms The Indicator Interval time 200ms Exit Setup…
  • Page 28: Read Beep

    Enter Setup 2、Read Beep (1)All Indicator Disable Power on Beep * Enable Power on Beep Disable Setting Code Beep * Enable Setting Code Beep Exit Setup…

  • Page 29: (2)Successful Sound Remind

    Enter Setup Medium Loud (2)Successful sound remind * Use Sound remind Do not use Sound remind *Sound remind 1 time Sound remind 2 times Exit Setup…

  • Page 30: (3)Beep Frequency

    Enter Setup Set sound remind times(1~5) (3)Beep Frequency Set Beep Frequency 1600Hz *Set Beep Frequency2700Hz Set Beep Frequency 3200Hz Set Beep Frequency4200Hz Good Read Beep Frequency(100 ~ 20,000Hz) Exit Setup…

  • Page 31: (4)Good Read Beep Time

    Enter Setup (4)Good Read Beep time Set Beep time 50ms * Set Beep time100ms Set Beep time 150ms Set Beep time 200ms Set Beep time 250ms Set Beep time 300ms Exit Setup…

  • Page 32: Decoding Status Remind

    Enter Setup 3、Decode status remind Enable NG(NoRead) *Disable NG(NoRead) Set NoRead information (1-16bytes) 4、Keyboard language United States Belgium Exit Setup…

  • Page 33
    Enter Setup Brazil Canada French Czech Denmark Finland France Germany Exit Setup…
  • Page 34
    Enter Setup Greek Hungary Israel Italy Latin America Dutch Netherlands Norway Exit Setup…
  • Page 35
    Enter Setup Poland Portugal Romania Russia Slovakia Spain Exit Setup…
  • Page 36
    Enter Setup Sweden Switzerland German Turkey F Turkey Q Unite Kingdom Japan ASCII Italian 14 Exit Setup…
  • Page 37: Set Virtual Keyboard

    Enter Setup 5、Set Virtual Keyboard Output Characters ALT+Numeric keys * Output characters using a large keyboard Use «Ctrl» to combine output control characters *Original output control character Enable Small keypad * Disable Small keypad 6、Capslock Keyboard letter conver, in the output of the barcode with letter content, you can set the code to make the output result is all to Upper Case or Lower Case.

  • Page 38: Data Encoding Format

    Enter Setup * No Case Conversion Conver All to Upper Case Conver All to Lower Case Letter case interchange Using Shift to unblock uppercase locking Using Capslock to unblock uppercase locking 7、Data encoding format To enable the host to print Chinese data in the specified encoding format, you can set it by reading «data encoding format»…

  • Page 39: Vat Invoice Automatic Identification Output Function

    Enter Setup GBK Chinese direct transmission GBK-Unicode Chinese direct transmission BIG5 Chinese direct transmission BIG5-Unicode direct transmission *Disable Chinese direct transmission 8、VAT invoice automatic identification output function * on Exit Setup…

  • Page 40: Image Flipping

    Enter Setup 9、 Image Flipping (Mirror Image) *Do Not Flip Flip Horizontally & Vertically Flip Vertically Flip Horizontally Exit Setup…

  • Page 41: Chapter 7 Data Editing

    Enter Setup Charpter 7: Data editing 1、Data editing Enable/Disable *Enable Data editing Disable Data editing 2、Symbol name display Enable Symbol name display Disable Symbol name display 3、Symbol length display Enable Symbol length output Exit Setup…

  • Page 42: Code Id

    Enter Setup Disable Symbol length output 4、CODE ID Users can identify different barcode types by Code ID. The corresponding Code ID of each barcode type can be modified by themselves (the corresponding setting Code can be found in the enable/disable configuration of barcode type). Code ID USES one character to identify , see appendix 3.

  • Page 43: Terminal Character

    Enter Setup * Disable AIM ID output 5、Terminal Charater *Enable Terminal Charater Disable Terminal Charater Do Not Add Terminal Character Set Terminal CR Set Terminal CR+LF Exit Setup…

  • Page 44: Prefix/Suffix Setting

    Enter Setup Set Terminal TAB Set Terminal CR+CR Set Terminal CR+LF+CR+LF Set Terminator Character (1-8 bytes) 6、Prefix/Suffix Setting Prefix/suffix is a user-defined modified charater string before or after decoding information, which can be added by scanning «Enable prefix» or «Enable suffix» setting code. Set prefix/suffix, scan setting codes of «set prefix»…

  • Page 45
    Enter Setup *Disable Prefix Enable Prefix(1~16bytes) *Disable Suffix Enable Suffix Enable Suffix(1~16bytes) Exit Setup…
  • Page 46: Chapter 8 Symbologies Edding And Enable/Disable Configuration

    Enter Setup Charpter8:Symbologies edding and enable/disableconfiguration Disable All Symbologies Enable All Symbologies Disable 1D Symbologies Enable 1D Symbologies Disable 2D Symbologies Enable 2D Symbologies Exit Setup…

  • Page 47: Ean-8

    Enter Setup EAN-8 * Enable EAN-8 Disable EAN-8 Do Not Transmit Code 11 Check Character *Transmit Code 11 Check Character Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 48: Ean-13

    Enter Setup Convert EAN-8 to EAN-13 Do not Convert EAN-8 to EAN-13 Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Exit Setup…

  • Page 49
    Enter Setup Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter EAN-13 Enable EAN-13 Disable EAN-13 Do Not Transmit Check Character After Verification Exit Setup…
  • Page 50
    Enter Setup Transmit Check Character After Verification On ISBN/ISSN translation Off ISBN/ISSN translation 10 Digit ISBN 13 Digit ISBN Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 51
    Enter Setup Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Exit Setup…
  • Page 52
    Enter Setup Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter Exit Setup…
  • Page 53: Upc-E

    Enter Setup UPC-E * Enable UPC-E Disable UPC-E Do Not Transmit Code 11 Check Character * Transmit Code 11 Check Character Enable UPC-E1 * UPC-E1: Disable UPC-E1 Set No.1 Code ID Exit Setup…

  • Page 54
    Enter Setup Set No.2 Code ID Enable 2-Digit Add on code Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Do Not Require Add-On Code Exit Setup…
  • Page 55
    Enter Setup Add Delimiter before the Add-on Code Do not Delimiter Add US country Code 0 Do Not add Country code System Character Do Not system Character Convert UPC-E1 to UPC-A Exit Setup…
  • Page 56: Upc-A

    Enter Setup Do Not Convert UPC-A UPC-A *Enable UPC-A Disable UPC-A Do Not Transmit Check Character After Verification Transmit Check Character After Verification Enable 2-Digit Add on code Exit Setup…

  • Page 57
    Enter Setup Disable 2-Digit Add-On Code Enable 5-Digit Add On Code Disable 5-Digit Add-On Code Equire Add-On Code Do Not Require Add-On Code Add Delimiter before the Add-on Code Do not Delimiter Exit Setup…
  • Page 58
    Enter Setup Set No.1 Code ID Set No.2 Code ID Add US country Code 0 Do Not add Country code System Character Do Not system Character Exit Setup…
  • Page 59: Code 128

    Enter Setup Code 128 * Enable Code 128 Disable Code 128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 60: Gs1-128

    Enter Setup GS1-128 *Enable GS1-128 Disable GS1-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 61: Aim-128

    Enter Setup AIM-128 *Enable AIM-128 Disable AIM-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.1 Code ID Exit Setup…

  • Page 62: Isbt-128

    Enter Setup ISBT-128 *Enable ISBT-128 Disable ISBT-128 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 63: Interleaved 2 Of 5

    Enter Setup Interleaved 2 of 5 *Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID *Disable Exit Setup…

  • Page 64
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 65: China Post 2 Of 5

    Enter Setup China Post 2 of 5 Transmit Check Character After Verification *Disable Code 2 of 5 China Post Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 66
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 67: Matrix 2 Of 5

    Enter Setup Matrix 2 of 5 Enable Matrix 2 of 5 Disable Matrix 2 of 5 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 68
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 69: Industrial 2 Of 5

    Enter Setup Industrial 2 of 5 Enable Code 2 of 5 Industrial Disable code 2 of 5 industrial Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 70
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 71: Iata 2 Of 5

    Enter Setup IATA 2 of 5 Enable Code 2 of 5 IATA *Disable code 2 of 5 IATA Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID * Disable Exit Setup…

  • Page 72
    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 73: Itf-14

    Enter Setup ITF-14 Enable ITF-14 * Disable ITF-14 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 74
    Enter Setup DP-12 Enable DP-12 * Disable DP-12 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 75: Dp14

    Enter Setup DP-14 Enable DP-14 * Disable DP-14 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 76: Msi

    Enter Setup Enable MSI * Disable MSI Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 77
    Enter Setup Check Character Verification *One Check Character, No output One Check Character Input Two Check Characters, MOD10/MOD10 No output Two Check Characters, MOD10/MOD10 Input Two Check Characters, MOD10/MOD11 No output Two Check Characters, MOD10/MOD11 Input Disable Exit Setup…
  • Page 78: Code11

    Enter Setup Code 11 Enable Code 11 * Disable Code 11 Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set the Minimum Length Set the Maximum Length Set No.1 Code ID Exit Setup…

  • Page 79: Code 39

    Enter Setup Set No.2 Code ID Code 39 *Enable Code 39 Disable Code 39 Transmit Start/Stop Character Do Not Transmit Start/Stop Character Enable Code 39 Full ASCII Exit Setup…

  • Page 80
    Enter Setup Disable Code 39 Full ASCI Set the Minimum Length Set the Maximum Length * Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification Set No.1 Code ID Exit Setup…
  • Page 81: Code 32

    Enter Setup Set No.2 Code ID Code 32 Enable Code 32 * Disable Code 32 *Enable Code 32 Prefix“A” Disable Code32 Prefix “A” Exit Setup…

  • Page 82: Code 93

    Enter Setup Code 93 * Enable Code 93 Disable Code 93 Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 83: Codabar

    Enter Setup Codabar *Enable Codabar Disable Codabar Set the Minimum Length Set the Maximum Length Transmit Start/Stop Character Do Not Transmit Start/Stop Character Exit Setup…

  • Page 84
    Enter Setup Set No.1 Code ID Set No.2 Code ID Check Character Verification * Disable Do Not Transmit Check Character After Verification Transmit Check Character After Verification Exit Setup…
  • Page 85
    Enter Setup Start/Stop Character * ABCD/ABCD ABCD/TN*E abcd/abcd abcd/tn*e Exit Setup…
  • Page 86: Plessey

    Enter Setup Plessey Enable Plessey * Disable Plessey Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.1 Code ID * Disable Exit Setup…

  • Page 87: Rss-14

    Enter Setup Do Not Transmit Check Character After Verification Transmit Check Character After Verificatio RSS-14 * Enable RSS-14 Disable RSS-14 * Transmit Application Identifier “01” Do Not Transmit Application Identifier Exit Setup…

  • Page 88: Rss-Limited

    Enter Setup Set No.1 Code ID Set No.2 Code ID RSS-Limited *Enable RSS-Limited Disable RSS-Limited * Transmit Application Identifier “01” Do Not Transmit Application Identifier Exit Setup…

  • Page 89: Pdf-417

    Enter Setup Set No.1 Code ID Set No.2 Code ID PDF-417 * Enable PDF417 Disable PDF417 Set the Minimum Length Set the Maximum Length Exit Setup…

  • Page 90
    Enter Setup Set No.1 Code ID Set No.2 Code ID *Allowable structural connection Do Not allowable structural connection Exit Setup…
  • Page 91: Qr Code

    Enter Setup QR Code * Enable QR Code Disable QR Code Set the Minimum Length Set the Maximum Length *Allowable structural connection Do Not allowable structural connection *Read mirror symbol Exit Setup…

  • Page 92
    Enter Setup Do not read mirror symbol Set No.1 Code ID 、 Set No.2 Code ID Enable OR code *Disable QR code Exit Setup…
  • Page 93: Data Matrix

    Enter Setup Data Matrix *Enable Data matrix Disable Data matrix Set the Minimum Length Set the Maximum Length *Enable Rectangular Barcode Disable Rectangular Barcode *Enable Inverse code Exit Setup…

  • Page 94
    Enter Setup Disable inverse code *Read mirror symbol Do not read mirror symbol *Allowable structural connection Do Not allowable structural connection Set No.1 Code ID Set No.2 Code ID Exit Setup…
  • Page 95: Aztec Code

    Enter Setup Aztec Code *Enable Aztec Disable Aztec Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 96: Maxicode

    Enter Setup Maxicode Enable Maxicode *Disable Maxicode Set the Minimum Length Set the Maximum Length Set No.1 Code ID Set No.2 Code ID Exit Setup…

  • Page 97: Appendix 1:Set Digital Code

    Enter Setup Appendix 1 Digit Barcodes Save Cancel Reset Exit Setup…

  • Page 98: Appendix 2 Ascii Table

    Enter Setup Appendix 2 ASCII Table Scanni Scanni Keybo Scanni Keybo Keyboard value value value value value value 1000 Null 1043 1086 1001 Keypad Enter 1044 1087 1002 Caps lock 1045 1088 1003 Right Arrow 1046 1089 1004 Up Arrow 1047 1090 1005…

  • Page 99
    Enter Setup 1032 Space 1075 1118 1033 1076 1119 1034 “ 1077 1120 1035 1078 1121 1036 1079 1122 1037 1080 1123 1038 & 1081 1124 1039 ‘ 1082 1125 1040 1083 1126 1041 1084 1042 1085 Exit Setup…
  • Page 100: Ascii Table 3 Defaults Table

    Enter Setup ASCII Table 3 Defaults Table Symbol type Code ID Character Decimal value Hexadecimal value Code 128 GS1-128 Code 39 EAN-8 EAN-13 UPC-E UPC-A Interleaved 2 of 5 ITF-14 Codabar Plessey Matrix 2 of 5 Industrial 2 of 5 IATA 2 of 5 Chinese Post 2 of 5 DP12…

Сканер DBS HC-3208SR используется для считывания линейных и двумерных штрихкодов. Благодаря своим характеристикам, он уже завоевал популярность среди аналогов. Модель имеет возможность считывать маркировку алкогольной и табачной продукции, что довольно актуально в условиях внедрения систем ЕГАИС/ФГИС на российский рынок.

More details

Модификации товара Цена Добавить в корзину цена
Сканер штрих-кода DBS HС-3208SR (Bluetooth, радио 433MHz, 2D imager High Resolution, кабель USB) 8 512,72 ₽
(ВКЛ НДС)

8512.72

Скидки при оптовом заказе

Читайте отзывы покупателей и оценивайте качество магазина на Яндекс.Маркете

  • Описание
  • Характеристики
  • Видеообзор
  • Аксессуары
  • Инструкции и руководства
  • Отзывы(0)
  • Драйверы
  • ПО

Особенности сканера DBS HC-3208SR 2D

Корпус беспроводного сканера штрих-кодов DBS HC-3208SR 2D выполнен из прочного ABS-пластика. Кроме того степень защиты от пыли и влаги довольно высока. Все это позволяет устройству работать при различных условиях, например в пыльном складе. Случайное падение с высоты также не является проблемой. Важным преимуществом использования сканирующего изделия можно отметить компактность габаритов 151,9х68х98,1 мм при весе в 0,13 кг. Для связи с другим pos-оборудованием в DBS HC-3208SR внедрены USB и RS232 интерфейсы. Для шумных помещений с плохой видимостью модель оснащена звуковым и световым индикатором, что делает понимание успешности операции возможным.

  • Преимущества
  • Стильный дизайн.
  • Компактные размеры.
  • Надежность.
  • Устойчивость к повреждениям.
  • Ёмкая АКБ.
  • Поддержка большинства кодировок 1D, 2D.

Для увеличения эффективности среднего и малого бизнеса стоит купить такое устройство.

Комплектация сканера DBS HC-3208SR

Помимо сканера DBS HC-3208, стандартная комплектация включает:

  • интерфейсный USB-шнур длиной 1,8 м;
  • краткую инструкцию по настройке 2D-имиджера;
  • гарантийный талон.

Сканер опционально поставляется в комплекте с зарядно-коммуникационной подставкой.

Скачать руководство для настройки DBS HC-3208SR можно в разделе «Инструкции и руководства».

В нашем интернет-магазине favorit-scan.ru — вы можете приобрести Сканер штрих-кода DBS HC-3208SR по доступной цене, с доставкой. Вы можете убедиться в этом самостоятельно — сделав заказ у нас. Если у вас возникли трудности с выбором и вам нужна помощь, позвоните по телефону 8 (800) 777-02-59 и вы получите консультацию специалиста.

У данного товара нет аксессуаров.

У данного товара нет вложений.

Похожие товары

  • Сканер штрих-кода Mertech CL-2210

    8 610,57 ₽


    In Stock

    Сканер штрих-кода Mertech CL-2210 представляет собой надежное устройство, которое станет полезным помощником в вашей работе. Этот универсальный беспроводной сканер идеально подходит для различных сфер деятельности, включая торговлю, фабрики, заводы и магазины. Он оснащен прочным корпусом, который обеспечивает защиту от механических повреждений, позволяя…

  • Сканер штрих-кода Honeywell 1950g

  • Сканер штрих-кода Mertech 2210

    4 892,37 ₽


    In Stock

    Сканер штрихкодов MERTECH 2210 P2D представляет собой усовершенствованный вариант MERTECH 2200. Новая модель соответствует стандартам «Честный ЗНАК» и ЕГАИС. MERTECH 2210 P2D имеет более новую технологию считывания SUPERLEAD. Это упрощает работу со сканированием штрихкодов с гладких и прозрачных поверхностей, как пленка или стекло.

  • Сканер штрих-кода Mertech CL-2310

    8 904,11 ₽


    In Stock

    Сканер штрих-кода Mertech CL-2310 отличается высокой скоростью сканирования, до 100 штук в минуту. Использует технологию SuperLead от компании Mertech Equipment.
    Считывает большинство типов известных штрих-кодов, в том числе и со сложных поверхностей, таких как стекло, пленки или экран мобильного телефона. Корпус Mertech CL-2310 соответствует стандарту…

  • Сканер штрих-кода Sunlux XL-3610

    4 109,59 ₽


    In Stock

    Ручной сканер штрих-кода Sunlux XL-3610 подойдет для использования на складах, в аптеках, торговых точках, ресторанах. Способен считывать 1D и 2D маркировки со скоростью до 60 сканов в секунду. В него встроен 32-х битный процессор ARM и сенсор CMOS. Совместим с ОС Windows 7/8/10, iOS, Android, Linux. Имеет защиту IP54. Поддерживает онлайн обновление…

Like this post? Please share to your friends:
  • Сканер creader 3001 инструкция по применению на русском языке
  • Сканер brother ads 2400n инструкция
  • Сканер atol sb2108 plus инструкция
  • Скандонест инструкция по применению в стоматологии цена
  • Скандонест инструкция по применению в стоматологии для аллергиков отзывы