Udian контроллер температуры инструкция на русском

Yudian AI Series Operation Instruction Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

AI SERIES ARTIFICIAL INTELLIGENCE INDUSTRIAL CONTROLLER

AI-518/518P Operation Instruction

Ver. 7.1

loading

Related Manuals for Yudian AI Series

Summary of Contents for Yudian AI Series

  • Page 1
    AI SERIES ARTIFICIAL INTELLIGENCE INDUSTRIAL CONTROLLER AI-518/518P Operation Instruction Ver. 7.1…
  • Page 2: Table Of Contents

    CONTENTS SUMMARY …………………………..1 EATURES RDERING EFINITION MODULES New advanced module technology ENTINANCE TECHNICAL SPECIFICATION ……………………… 4 REAR TERMINAL LAYOUT AND WIRING …………………. 6 DISPLAYS AND OPERATIONS ……………………..8 RONT ANEL ESCRIPTION ISPLAY TATUS PERATION ESCRIPTION 4.2.1 Display status switch 4.2.2 Set Value Setting 4.2.3…

  • Page 3: Summary

    Ordering Code Definition Advanced modularized hardware design is utilized for AI series instruments. There are maximum five module sockets: multi-function input/output (MIO), main output (OUTP), alarm (ALM), auxiliary output (AUX) and communication (COMM). The input specification can be selected as thermocouple, RTD, or linear current/voltage.

  • Page 4
    symbols. ① Instrument model AI-518 High accuracy controller with measurement accuracy 0.3%F.S. It adopts artificial intelligent control technology, and has the functions of control, alarm, retransmission and communication. AI-518P Add 30 segment program control to AI-518. ② Front panel dimension Depth Front Panel Cut-out…
  • Page 5: Modules

    circuit; each channel can trigger TRIAC or a pair of inverse parallel SCR with current of 5-500A) “Burn-proof” single-phase thyristor phase-shift trigger output module (trigger one loop of TRIAC or a pair of inverse parallel SCR with current of 5-500A), suitable for 200~240VAC power supply.

  • Page 6: New Advanced Module Technology

    Clean and clearance is needed. Time won’t influence the accuracy of AI intruments,so don’t try to change parameter by changing Sc parameter. If problem happens, please return to YUDIAN factory. AI controllers are default with 60 days warranty after the data of departure factory.During this period, free repair is available.

  • Page 7
     Instrument Input range K(-100~1300℃), S(0~1700℃), R(0~1700℃), T(-200~+390℃), E(0~1000℃), J(0~1200℃), B(600~1800℃), N(0~1300℃), WRe3-WRe25(0~2300℃), WRe5-WRe26(0~2300℃) Cu50(-50~+150℃), Pt100(-200~+800℃) Linear Input: -9990~30000 defined by user.  Measurement accuracy : 0.3%FS ± 0.1℃  Resolution : 0.1℃ (automatically change to 1℃ when the temperature is high than 999.9℃) or 1℃ selectable …
  • Page 8: Rear Terminal Layout And Wiring

    3. Rear Terminal Layout and Wiring Wiring graph for instruments except D and D2 dimension. 100-240VAC~ Thyristor trigger output(K1/K3) OUTP Thyristor trigger output(K3) COMM Thyristor trigger output(K3) The graph suits for upright instruments with dimension A, C or E 0-5V 1-5V For instruments with dimension F, just clockwise rotate the graph 90 degree,…

  • Page 9
    module is installed in COMM and parameter “bAud” is set to 1, then on-off signal can be inputted, and SV1 and SV2 can be switched by connecting a switch between terminals 3 and 4. Wiring graph of D2 dimension instruments (48*48mm) P.S.:0-5 1-5 is not available ,transfer to 0-500mV or 100-500mV input.
  • Page 10: Displays And Operations

    4. DISPLAYS AND OPERATIONS Front Panel Description ① Upper display window, displays parameter code, etc. ② Lower display window, displays SV, parameter value, or alarm ③ Setup key, for accessing parameter table and conforming parameter modification. ④ Data shift key, and auto/manual control switch.

  • Page 11: Operation Description

    4.2.2 If the lower display window alternately display “HIAL”, “LoAL”, “HdAL” or “LdAL”, it means high limit alarm, low limit alarm, deviation high alarm, and deviation low alarm occurs. The alarm display can also be turned off by setting parameter “cF”. 4.2.3.

  • Page 12
    On the basis of disturbance caused by on-off control, oscillation period, amplitude and waveform are analyzed to calculate optimum control parameters. The auto tuning for AI series instrument will gratify for 90% users. Due to the complexity of the automatic process, parameters calculated by auto tuning are probably not the optimal values on some special occasion (mentioned as follows).
  • Page 13: Program Operation (For Ai-518P Only)

    Program operation (for AI-518P only) 4.4.1 Setup program once and release in the display status ①, the instrument will be in the setup program Press the key 、 status. The setpoint of the current program StEP will be displayed. Pressing or c can modify the value.

  • Page 14: Parameters And Settings

    5. PARAMETERS AND SETTINGS The Full Parameter Table Setting Code Name Description Range Alarm is triggered when PV (Process Value) >HIAL; -1999~ alarm is released when PV<HIAL-dF; HIAL High limit alarm +9999 To disable high limit alarm, set HIAL=9999 units or Every alarm can be defined to control AL1,AL2,AU1,AU2 Alarm triggered when PV<LoAL;…

  • Page 15
    Lag time parameter “t” is a new parameter seconds introduced important parameter for AI artificial intelligence algorithm. AI series instrument can use parameter “t” to do fuzzy calculation, and therefore overshoot and hunting do not easily occurs and the control have the best responsibility at the time.
  • Page 16
    Input spec. Input spec. Cu50 Pt100 stock 0~75mV 0~80ohm resistor input 0~400ohm resistor input 0~20mV voltage input 0~100mV voltage input 0~60mV voltage input WRe3-WRe25 0~1V voltage input WRe5-WRe26 0.2~1V voltage input Input specification extended input 0~37 1~5V voltage input Code specification radiation type…
  • Page 17
    OP1 select the control output type: OP1=OP1.A x 1 + OP1.B x 10 OP1.A shows the output type of OUTP. It should be compatible with the module installed in OUTP sockets. OP1.A=0, if output modules such as SSR voltage output, relay contact discrete output, thyristor cross zero trigger output, and TRIAC no-contact discrete output are installed in OUTP.
  • Page 18
    From right side to left side, the first, second, third and fourth digit of ALP individually indicate the alarm output terminal of HIAL, LoAL, HdAL, and LdAL. 0 shows no output. 1 and 2 are spare for future use. 3,4,5 and 6 respectively indicate alarms outputted to AL1, AL2, AU1 or AU2.
  • Page 19
    The value of dL will determine the ability of filtering noise. There is one intermediate-value filter system and one second order integral digital filter system in AI series instrument. Intermediate value filter takes intermediate value among three continuous values, while integral filter has the same effect as resistance-capacity integral filter.
  • Page 20: Additional Remarks Of Special Functions

    StEP value can not be modified. Loc=808, allowed to set all parameters, program and StEP value. Note: that 808 is the password of all AI series instrument. In application the instrument should be set to other values to protect from modifications of parameters.

  • Page 21: Alarm Blocking At The Beginning Of Power On(Cf.b=1)

    5.2.2 Single phase contact output (oP1-8) Phase-shifting output is usually realised by TRIAC.but it will has influence on heater, so please make sure of the anti-interference of other equipments when use it. 5.2.3 SV limit setting (only for AI-518,and CF.C=0) SV is usually between HIAL and LoAL.

  • Page 22: Widely Used Control Mode

    RS232/RS485 changable. One computer with two communication interfaces are workable with 100 units controllers. Diffferent communication addresses are needed. AI-485 AIBUS is advised to be used with AI series instruments. Computer AI series intruments upto 100units 6.

  • Page 23: Ai Artificial Intelligent Regulator

    4~20mA. 6.3 AI artificial intelligent regulator AI series controllers are developed with advanced AI artificial intelligent fuzzy logic control mode, high accuracy. Advanced Auto turning function can help users to set parameters. AI-518P has the programmable control function. When CtrL is 1-4, then the unit is able to regulate other functions.

  • Page 24: Programming And Operation Editting

    (cooling-down). This phenomenon is normal. 7.2 Programming and operation editting Programming of AI series instrument has uniform format of temperature-time-temperature, which means that temperature set for current StEP will change to temperature set for next StEP after the time set for the current StEP.

  • Page 25
    jump to StEP5. StEP5: C05=160 , t05=0 The program get in Hold state, and run operation executed by operator is needed for the program to continue running to StEP 6. StEP6: C06=100 , t06=-151 Alarm 1 is switch off, and jump to StEP1 to start from beginning. In this example, it is assumed that the positive deviation alarm is set to 5℃.
  • Page 26
    AI-518P has the advanced function of flexible program arrangement. Normally, when the program stops, the StEP will be automatically set to1. Thus if StEP is not change to other value, a program will start from step1. If multiple curves are defined, the control can jump to different curve by setting step 1 as jump segment.

Yudian AI Series Operation Instruction Manual

  • Contents

  • Table of Contents

  • Bookmarks

Quick Links

AI SERIES ARTIFICIAL INTELLIGENCE INDUSTRIAL CONTROLLER

AI-518/518P Operation Instruction

Ver. 7.1

Related Manuals for Yudian AI Series

Summary of Contents for Yudian AI Series

  • Page 1
    AI SERIES ARTIFICIAL INTELLIGENCE INDUSTRIAL CONTROLLER AI-518/518P Operation Instruction Ver. 7.1…
  • Page 2: Table Of Contents

    CONTENTS SUMMARY …………………………..1 EATURES RDERING EFINITION MODULES New advanced module technology ENTINANCE TECHNICAL SPECIFICATION ……………………… 4 REAR TERMINAL LAYOUT AND WIRING …………………. 6 DISPLAYS AND OPERATIONS ……………………..8 RONT ANEL ESCRIPTION ISPLAY TATUS PERATION ESCRIPTION 4.2.1 Display status switch 4.2.2 Set Value Setting 4.2.3…

  • Page 3: Summary

    Ordering Code Definition Advanced modularized hardware design is utilized for AI series instruments. There are maximum five module sockets: multi-function input/output (MIO), main output (OUTP), alarm (ALM), auxiliary output (AUX) and communication (COMM). The input specification can be selected as thermocouple, RTD, or linear current/voltage.

  • Page 4
    symbols. ① Instrument model AI-518 High accuracy controller with measurement accuracy 0.3%F.S. It adopts artificial intelligent control technology, and has the functions of control, alarm, retransmission and communication. AI-518P Add 30 segment program control to AI-518. ② Front panel dimension Depth Front Panel Cut-out…
  • Page 5: Modules

    circuit; each channel can trigger TRIAC or a pair of inverse parallel SCR with current of 5-500A) “Burn-proof” single-phase thyristor phase-shift trigger output module (trigger one loop of TRIAC or a pair of inverse parallel SCR with current of 5-500A), suitable for 200~240VAC power supply.

  • Page 6: New Advanced Module Technology

    Clean and clearance is needed. Time won’t influence the accuracy of AI intruments,so don’t try to change parameter by changing Sc parameter. If problem happens, please return to YUDIAN factory. AI controllers are default with 60 days warranty after the data of departure factory.During this period, free repair is available.

  • Page 7
     Instrument Input range K(-100~1300℃), S(0~1700℃), R(0~1700℃), T(-200~+390℃), E(0~1000℃), J(0~1200℃), B(600~1800℃), N(0~1300℃), WRe3-WRe25(0~2300℃), WRe5-WRe26(0~2300℃) Cu50(-50~+150℃), Pt100(-200~+800℃) Linear Input: -9990~30000 defined by user.  Measurement accuracy : 0.3%FS ± 0.1℃  Resolution : 0.1℃ (automatically change to 1℃ when the temperature is high than 999.9℃) or 1℃ selectable …
  • Page 8: Rear Terminal Layout And Wiring

    3. Rear Terminal Layout and Wiring Wiring graph for instruments except D and D2 dimension. 100-240VAC~ Thyristor trigger output(K1/K3) OUTP Thyristor trigger output(K3) COMM Thyristor trigger output(K3) The graph suits for upright instruments with dimension A, C or E 0-5V 1-5V For instruments with dimension F, just clockwise rotate the graph 90 degree,…

  • Page 9
    module is installed in COMM and parameter “bAud” is set to 1, then on-off signal can be inputted, and SV1 and SV2 can be switched by connecting a switch between terminals 3 and 4. Wiring graph of D2 dimension instruments (48*48mm) P.S.:0-5 1-5 is not available ,transfer to 0-500mV or 100-500mV input.
  • Page 10: Displays And Operations

    4. DISPLAYS AND OPERATIONS Front Panel Description ① Upper display window, displays parameter code, etc. ② Lower display window, displays SV, parameter value, or alarm ③ Setup key, for accessing parameter table and conforming parameter modification. ④ Data shift key, and auto/manual control switch.

  • Page 11: Operation Description

    4.2.2 If the lower display window alternately display “HIAL”, “LoAL”, “HdAL” or “LdAL”, it means high limit alarm, low limit alarm, deviation high alarm, and deviation low alarm occurs. The alarm display can also be turned off by setting parameter “cF”. 4.2.3.

  • Page 12
    On the basis of disturbance caused by on-off control, oscillation period, amplitude and waveform are analyzed to calculate optimum control parameters. The auto tuning for AI series instrument will gratify for 90% users. Due to the complexity of the automatic process, parameters calculated by auto tuning are probably not the optimal values on some special occasion (mentioned as follows).
  • Page 13: Program Operation (For Ai-518P Only)

    Program operation (for AI-518P only) 4.4.1 Setup program once and release in the display status ①, the instrument will be in the setup program Press the key 、 status. The setpoint of the current program StEP will be displayed. Pressing or c can modify the value.

  • Page 14: Parameters And Settings

    5. PARAMETERS AND SETTINGS The Full Parameter Table Setting Code Name Description Range Alarm is triggered when PV (Process Value) >HIAL; -1999~ alarm is released when PV<HIAL-dF; HIAL High limit alarm +9999 To disable high limit alarm, set HIAL=9999 units or Every alarm can be defined to control AL1,AL2,AU1,AU2 Alarm triggered when PV<LoAL;…

  • Page 15
    Lag time parameter “t” is a new parameter seconds introduced important parameter for AI artificial intelligence algorithm. AI series instrument can use parameter “t” to do fuzzy calculation, and therefore overshoot and hunting do not easily occurs and the control have the best responsibility at the time.
  • Page 16
    Input spec. Input spec. Cu50 Pt100 stock 0~75mV 0~80ohm resistor input 0~400ohm resistor input 0~20mV voltage input 0~100mV voltage input 0~60mV voltage input WRe3-WRe25 0~1V voltage input WRe5-WRe26 0.2~1V voltage input Input specification extended input 0~37 1~5V voltage input Code specification radiation type…
  • Page 17
    OP1 select the control output type: OP1=OP1.A x 1 + OP1.B x 10 OP1.A shows the output type of OUTP. It should be compatible with the module installed in OUTP sockets. OP1.A=0, if output modules such as SSR voltage output, relay contact discrete output, thyristor cross zero trigger output, and TRIAC no-contact discrete output are installed in OUTP.
  • Page 18
    From right side to left side, the first, second, third and fourth digit of ALP individually indicate the alarm output terminal of HIAL, LoAL, HdAL, and LdAL. 0 shows no output. 1 and 2 are spare for future use. 3,4,5 and 6 respectively indicate alarms outputted to AL1, AL2, AU1 or AU2.
  • Page 19
    The value of dL will determine the ability of filtering noise. There is one intermediate-value filter system and one second order integral digital filter system in AI series instrument. Intermediate value filter takes intermediate value among three continuous values, while integral filter has the same effect as resistance-capacity integral filter.
  • Page 20: Additional Remarks Of Special Functions

    StEP value can not be modified. Loc=808, allowed to set all parameters, program and StEP value. Note: that 808 is the password of all AI series instrument. In application the instrument should be set to other values to protect from modifications of parameters.

  • Page 21: Alarm Blocking At The Beginning Of Power On(Cf.b=1)

    5.2.2 Single phase contact output (oP1-8) Phase-shifting output is usually realised by TRIAC.but it will has influence on heater, so please make sure of the anti-interference of other equipments when use it. 5.2.3 SV limit setting (only for AI-518,and CF.C=0) SV is usually between HIAL and LoAL.

  • Page 22: Widely Used Control Mode

    RS232/RS485 changable. One computer with two communication interfaces are workable with 100 units controllers. Diffferent communication addresses are needed. AI-485 AIBUS is advised to be used with AI series instruments. Computer AI series intruments upto 100units 6.

  • Page 23: Ai Artificial Intelligent Regulator

    4~20mA. 6.3 AI artificial intelligent regulator AI series controllers are developed with advanced AI artificial intelligent fuzzy logic control mode, high accuracy. Advanced Auto turning function can help users to set parameters. AI-518P has the programmable control function. When CtrL is 1-4, then the unit is able to regulate other functions.

  • Page 24: Programming And Operation Editting

    (cooling-down). This phenomenon is normal. 7.2 Programming and operation editting Programming of AI series instrument has uniform format of temperature-time-temperature, which means that temperature set for current StEP will change to temperature set for next StEP after the time set for the current StEP.

  • Page 25
    jump to StEP5. StEP5: C05=160 , t05=0 The program get in Hold state, and run operation executed by operator is needed for the program to continue running to StEP 6. StEP6: C06=100 , t06=-151 Alarm 1 is switch off, and jump to StEP1 to start from beginning. In this example, it is assumed that the positive deviation alarm is set to 5℃.
  • Page 26
    AI-518P has the advanced function of flexible program arrangement. Normally, when the program stops, the StEP will be automatically set to1. Thus if StEP is not change to other value, a program will start from step1. If multiple curves are defined, the control can jump to different curve by setting step 1 as jump segment.

Yudian AI-208 Operation Manual

  1. Manuals
  2. Brands
  3. Yudian Manuals
  4. Temperature Controller
  5. AI-208
  6. Operation manual
  • Bookmarks

Quick Links

Yudian (H.K.) Automation Technology Co. Ltd.

Website:

http://www.yudian.us http://www.yudian.com.hk

Email:

sales@yudian.com.hk

Tel: +852-2770 8785

Fax: +852-2770 8796

ARTIFICIAL INTELLIGENCE

TEMPERATURE CONTROLLER

AI-208 (V7.8)

Operation Manual

Related Manuals for Yudian AI-208

Summary of Contents for Yudian AI-208

  • Page 1
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.8) Operation Manual…
  • Page 2
    Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 I. Model Order Code The type of AI-208 is made up of 4 parts: AI-208 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4 (AUX) 1. (Part 1) Model Series AI-208, standard temperature controller , 0.3%FS±1℃…
  • Page 3: Technical Specification

    Dual relay output module Output module (Capacity: 2A/250VAC, normal open, support AU1 and AU2 alarm output) SSR voltage output module (30mA/5VDC) * D1-sized controller is fixed to SSR output(G) and no module option provided, i.e. AI-208-D1-G, AI-208-D1-G-L0 or AI-208-D1-G-L5 must be specified upon order. II. TECHNICAL SPECIFICATION 1.

  • Page 4: Front Panel And Operation

    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 III. FRONT PANEL AND OPERATION ① Process Value(PV), or parameter code Set Value(SV), alarming code, or value of a parameter ② Setup key, accessing parameter table, and confirming change.

  • Page 5
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 V. PARAMETER AND SETTING Title Description Range Parameter Field Parameter Table (Press and hold for 2 seconds to access) Alarm on when PV (Process Value) >HIA;…
  • Page 6
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 Smaller value will result in higher control accuracy. For SSR output, generally 0.5 to 3 seconds. For Relay output, generally 15 to 40 seconds, because small value will…
  • Page 7
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 VI. INSTRUMENT INSTALLATION AND WIRING DIAGRAM Panel dimension A1, B1, E1 or F1 Panel dimension A, B, E or F Main Output Alarm Output…
  1. What is the default setting of temperature controller AI-508 / AI-509?
    The default setting can be found of the manual in the download section underneath. 
     
  2. Is there any driver of National Instrument LabView?
    We are working on it. Reference: http://forums.ni.com/t5/Multifunction-DAQ/Automate-temperature-controller/m-p/1618094/highlight/false#M64849
     
  3. Does YUDIAN temperature controller / indicator support MODBUS?
    Yes. YUDIAN instruments support AIBUS. Starting from version 8.0 or above, YUDIAN instruments support both AIBUS and MODBUS. Setting AF.H=1 (x 128) can activate MODBUS support. 
     
  4. Which model supports MODBUS?
    Temperature Controller: AI-526, AI-526P Temperature Indicator: AI-5201. 
     
  5. How can I find out the serial number?
    Locate the small white label on the side of enclosure or back of the panel (LCD instrument). You may also refer to the details or other methods to find out the model number and firmware version
    below.

Download

Download

Temperature controller AI-508 / AI-509 Default Setting — Operation Manual
Q: What is the default setting of temperature controller AI-508 / AI-509?
A: The default setting can be found of the manual. Please note the default parameter Act should be «rE».
TemperatureControllerAI508509v75r1.pdf
Adobe Acrobat document [347.9 KB]

Download

Paperless Recorder AI-3170S: Analysis Software YDR_V1_01_07
Early AI-3170S required users to run this Analysis Software to read the encrypted data in the USB drive. Only on Windows platform.
Yudian_Analysis_Software_YDR_V1_01_07.zi[…]
Compressed archive in ZIP format [26.8 MB]

Download

Paperless Recorder AI-3170S: YUDIAN.BK
This is a file for recognition. Please unzip and copy this «yudian.bk» into the root directory of the USB drive and do not remove it. Otherwise no data will be exported.
yudian_bk.zip
Compressed archive in ZIP format [116 Bytes]

https://www.fedex.com/fedextrack/?tracknumbers=
us

http://www.ups.com/WebTracking/OnlineTool?trackNums=
en_US

Описание и отзывы

Характеристики

Регулятор температуры PID

Описание продукта:

.JPG

PRODUCT DESCRIPTION

Основные характеристики для регулятора температуры PID Yudian AI-518

  • Универсальные термопары, RTDs и линейные сигналы тока/напряженияВыбираемые, интегрированные Нелинейные градационные столы, Цифровая калибровка и автоматическая нулевая технология, и достижение точного и стабильного измерения.
  • Применение усовершенствованного алгоритма управления искусственным интеллектом AI с функцией автоматической настройки, без перебоев.
  • Поставляется с автоматическим/ручным бескорпусным переключателем и функцией мягкого запуска.
  • Применение передовой модульной структуры, удобно обеспечивая множество вариантов выхода, может удовлетворить различные требования приложения и сделать быструю доставку и легкое обслуживание.
  • Высокое качество и производительность аппаратного дизайна, используя высокопроизводительный танталовый конденсатор или керамический конденсатор. По сравнению с конкурирующими моделями, он потребляет меньше электроэнергии, переживает меньше перегрева температуры, обеспечивает более высокую стабильность и может работать в более широком диапазоне температур.
  • ISO9001 и CE сертифицированы, достигая мирового уровня качества, анти-помехи и безопасности.

Размер для регулятора температуры PID AI-518

Размер Передняя панель (Ш * В) Вырез (Ш * В) Глубина от монтажной поверхности
А 96*96 мм 92*92 мм

100 мм

B 160*80 мм 152*76 мм 100 мм
C 80*160 мм 152*76 мм 100 мм
D 72*72 мм 68*68 мм 95 мм
D2 48*48 мм 45*45 мм 95 мм
E 48*96 мм 45*92 мм 100 мм
F 96*48 мм 92*45 мм 100 мм

519 details_plus

519 key point

Передняя панель и управление для PID регулятора температуры

.JPG 

Упаковка & Доставка

Вы получите:

  1. Контроллер температуры;
  2. Бумага руководства пользователя;
  3. Гарантийный талон на один год/3 года и сертификат качества;
  4. Этикетка единиц;
  5. Пара монтажных кронштейнов;
  6. Хорошая картонная коробка с логотипом Yudian.

Больше продуктов

paste-pic-dp_uuid_a95wm

Похожие товары

AI-208 Manual | Manualzz

www.instrumentsolutions.com.au
ARTIFICIAL INTELLIGENCE
TEMPERATURE CONTROLLER
AI-208 (V7.6)
User Manual
www.instrumentsolutions.com.au
I. Model Code Symbol
The type of AI-208 is made up of 4 parts:
AI-208
A
G
L2
Part 1 (Series)
Part 2 (Size)
Part 3 (Oupt)
Part 4 (AUX)
1. (Part 1) Model Series
AI-208, standard temperature controller , 0.3%FS±1℃ accuracy.
Multiple thermocouples and RTDs are selectable
Suitable for 0~999℃ application. Maximum support two alarms contact output
Universal voltage input (100~240VAC)
2. (Part 2) Front panel dimension
Front Panel
Cut Out
width×height
width×height
A
96×96mm
92×92mm
100mm
B
160×80mm
152×76mm
100mm
D
72×72mm
68×68mm
95mm
D2
48×48mm
45×45mm
95mm
E
48×96mm
45×92mm
100mm
F
96×48mm
92×45mm
100mm
Size
Depth Behind Mounting Surface
www.instrumentsolutions.com.au
3. (Part 3 and 4) indicate the module installed in OUTP and AUX sockets.
Allowed modules in each socket are as below:
Allowed Type
N
L
L1
L5
G
Module Socket
√
3. OUTP (main output)
√
4. AUX (Auxiliary output)
√
√
√
N
(or none) no module installed
L
Relay contact output module (Capacity: 5A/250VAC, normal open)
L1
Relay contact output module (Capacity: 2A/250VAC, normal open/ normal close)
L5
Dual relay output module Output module (Capacity: 2A/250VAC, normal open, support AU1 and
AU2 alarm output)
G
SSR voltage output module (30mA/5VDC)
II. TECHNICAL SPECIFICATION
1. Input type :
Thermocouple: K, E, J, N
Resistance temperature detector: Pt100
2. Instrument Input range :
K, E, J, N : (0~+999)℃ ;
Pt100: (0~+800)℃
3. Measurement accuracy : 0.3%FS±1℃
4. Temperature display resolution : 0 or 0.0 (0.0 just for 0~99.9 display)
5. Control mode:
On-off control mode, or
PID control with the function of parameter auto tuning.
6. Alarm function: High limit alarm, Lower limit alarm, Deviation High Alarm; providing the function of
alarm blocking at the beginning of power on.
7. Power supply voltage rating: 100-240VAC, -15%, +10% / 50-60Hz.
8. Power consumption: ≤2W
9. Ambient temperature: -10~+60℃, Humidity: 0~90RH%
www.instrumentsolutions.com.au
III. FRONT PANEL AND OPERATION
①
Process Value(PV), or parameter code
②
Set Value(SV), alarming code, or value of a parameter
③
Setup key, for accessing parameter table, and confirming change.
④
Data shift key, also for activating auto turning
⑤
Data decrease key
⑥
Data increase key
⑦
Status display LED,
OP1, AU1, AU2, and RUN indicate I/O operation of the
corresponding module.
Basal display status:
When power on, will shows the process value (PV) and the set point (SV). lf the input signal is out of the measurable range (for example,
the thermocouple or RTD circuit is break, or input specification sets wrong). Instrument will alternately display “orA”, and limit alarm of PV,
moreover, instrument will automatically stop the output.
IV. OPERATION DESCRIPTION
●
Set Value Setting:
In basal display status, if the parameter lock “Loc” isn't locked,
key to decrease the value,
pressing
SPH.
●
or
we can set setpoint (SV) by pressing
key to increase the value, and
.
Press
key to move to the digit expected to modify.
Keep
, the speed of decreasing or inscreasing value get quick.
、
or
The range of setpoint is between the parameter
The default range is 0 to 400.
Parameter Setting:
In basal display status, press
and hold for about 2 seconds can access Field Parameter Table.
next parameter; if parameter have not locked, pressing
return to the preceding parameter. Press
、
or
Pressing
can modify a parameter.
(don't release) and then press
can go to the
Press and hold
parameter table. The instrument will escape auomatically from the parameter table if no key is pressed within 30 seconds.
Loc=808 and then press
●
can
key simultaneously can escape from the
Setting
can access System Parameter Table.
AI artificial intelligence control and auto tuning
When AI artificial intelligence control method is chosen (CrL=AI), the PID parameters can be obtained by running auto-tuning.
basal display status, press
to “on”, then press
for 2 seconds, the “At” parameter will appear.
to active the auto-tuning process.
Press
During auto tuning, the instrument executes on-off control.
times of on-off action, the instrument will obtain the optimal control parameter value.
press and hold the
In
to change the value of “At” from “oFF”
After 2-3
If you want to escape from auto tuning status,
key for about 2 seconds until the "At" parameter appear again.
Change “At” from “on” to “oFF”, press
to
confirm, then the auto tuning process will be cancelled.
Note 1:
If the setpoint is different, the parameters obtained from auto-tuning are possible different.
often-used value or middle value first, and then start auto-tuning.
be set at the highest applicable temperature.
So you’d better set setpoint to an
For the ovens with good heat preservation, the setpoint can
Depending on the system, the auto-tuning time can be from several seconds to
several hours.
Note 2:
Parameter Ctl (on-off differential, control hysteresis) has influence on the accuracy of auto-tuning.
value of Ctl, the higher the precision of auto tuning.
from error action around setpoint due to the oscillation of input.
Note 3:
Generally, the smaller the
But Ctl parameter value should be large enough to prevent the instrument
AI series instrument has the function of self-learning.
Ctl is recommended to be 2.0.
It is able to learn the process while working.
The control effect at the
first run after auto tuning is probably not perfect, but excellent control result will be obtained after a period of time because of
self-learning.
www.instrumentsolutions.com.au
V. PARAMETER AND SETTING
Field parameter table (Press
Code
Name
HIA
High limit alarm
LoA
Lower limit alarm
HdA
Deviation high
alarm
Loc
Parameter lock
AHY
Hysteresis
and hold for 2 seconds to access)
Description
Alarm on when PV (Process Value) >HIA;
alarm off when PV<HIA-AHY
Alarm on when PV (Process Value) < LoA;
alarm off when PV > LoA+AHY
Alarm on when PV-SV>HdA;
alarm off when PV-SV<HdA-AHY
Loc=0~1: Allowed to modify parameters HIA, LoA, HdA and SV.
Loc=2~3: Allowed to modify parameters HIA, LoA, HdA. But cannot
change SV.
Loc=4~255: NOT allowed to modify any parameters and SV.
Loc=808, Set to 808 and press
, allowed modify all parameters.
Avoid frequent alarm on-off action because of the fluctuation of PV,
usually sets to AHY=2
Alarm
HdA
LoA
HIA
(x100)
(x10)
(x1)
None
0
0
0
AU1
1
1
1
AU2
2
2
2
Output to
AOP
Alarm output
assignment
Setting Range
0~999℃
0~999℃
0~999℃
0~255
0~200
0~444
eg: AOP=201 means HdA have alarm action from AU2, LoA, no alarm
action , HIA alarm action output from AU1.
z
CrL
Control mode
z
onF : On-off control, When PV=SV, Output stop. When
PV<SV-CHY, start output.
AI : AI PID control, high precision and the output time proportion
can set by parameter Ctl
rE: Reverse acting. Increase in measured variable causes a decrease
in the output, such as heating control.
dr: Direct acting. Increase in measured variable causes an increase in
Act
Acting method
the output, such as refrigerating control.
rEb: Reverse acting with low limit alarm and deviation low alarm
rE , dr ,
rEb, drb
blocking at the beginning of power on.
drb: Direct acting with high limit alarm and deviation high alarm
blocking at the beginning of power on.
P
Proportion band
Proportion band in PID with unit ℃or ℉
I
Time of integral
Time of integral in PID. No integral effect when I=0
0~999 Sec
d
Time of
derivative
Time of derivative in PID. No derivative effect when d=0
0~999 Sec
Ctl
Control period
CHY
Control
hysteresis
Small value can improve control accuracy.
For SSR output, generally 0.5 to 3 seconds.
For Relay output, generally 15 to 40 seconds, because small value will
cause the frequent On-Off of mechanical switch and shorten its service
life. Ctl is recommended to be 1/4 – 1/10 of derivative time. When
control under on-off control, Ctl use as restart delay time after off, for
protect compressor application.
CHY is used for ON-OFF Control.
PV > SV, Output turns OFF;
PV<SV-CHY, Output turns ON.
1~999
0.5-300 SEC
0~200
www.instrumentsolutions.com.au
Sn
0
4
6
8-20
Input spec.
K
E
Spare
Spare
Sn
1-3
5
7
21
Input spec.
Spare
J
N
Pt100
InP
Input
specification
dPt
Resolution
0 or 0.0 selectable, 0.0 just for 0~99.9 ℃ / ℉ display
Scb
Input shift
Scb is used to make input shift to compensate the error produced by
sensor or input signal.
PV after compensation= PV before compensation + Scb.
-99~+99℃
FIL
PV input filter
The value of FIL will determine the ability of filtering noise.
When a large value is set, the measurement input is stabilized but the
response speed is slow. Generally, it can be set to 1 to 3.
If great interference exists, then you can increase parameter “FIL”
gradually to make momentary fluctuation of measured value less than
2 to 5.
When the instrument is being metrological verified, “FIL” s can be set
to 0 or 1 to shorten the response time.
0~40
Fru
Selection of
power frequency
and temperature
scale
0~21
50C: 50Hz, ℃
50F: 50Hz, ℉
60C: 60Hz, ℃
60F: 60Hz, ℉
SPH
Upper limit of SV
Maximum value that SV allowed to be. When SPH=400, the SV range
will 0~400℃
VI. INSTRUMENT INSTALLATION AND WIRING
Wiring graph for instruments with dimension A, B, E or F
1
100-240VAC~
2
3
Alarm Output
4
N/O
N/O
AU1
N/C
N/O
AU2
COM
COM
5
6
Main Output
AUX
+
N/O
COM
7
Note: The graph suits for
upright instruments with
dimension A or E
OUTP
8
9
10
+
For
instruments
with
dimension B or F size, just
clockwise rotate the graph
90 degree.
0~999℃
www.instrumentsolutions.com.au
Wiring graph for D2 dimension(48X48mm)instruments:
Wiring graph for D dimension (72mm X 72mm) instruments

Yudian AI-208 Operation Manual

  1. Manuals
  2. Brands
  3. Yudian Manuals
  4. Temperature Controller
  5. AI-208
  6. Operation manual

  • Bookmarks

Quick Links

Yudian (H.K.) Automation Technology Co. Ltd.

Website:

http://www.yudian.us http://www.yudian.com.hk

Email:

sales@yudian.com.hk

Tel: +852-2770 8785

Fax: +852-2770 8796

ARTIFICIAL INTELLIGENCE

TEMPERATURE CONTROLLER

AI-208 (V7.8)

Operation Manual

loading

Related Manuals for Yudian AI-208

Summary of Contents for Yudian AI-208

  • Page 1
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 ARTIFICIAL INTELLIGENCE TEMPERATURE CONTROLLER AI-208 (V7.8) Operation Manual…
  • Page 2
    Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 I. Model Order Code The type of AI-208 is made up of 4 parts: AI-208 Part 1 (Series) Part 2 (Size) Part 3 (Oupt) Part 4 (AUX) 1. (Part 1) Model Series AI-208, standard temperature controller , 0.3%FS±1℃…
  • Page 3: Technical Specification

    Dual relay output module Output module (Capacity: 2A/250VAC, normal open, support AU1 and AU2 alarm output) SSR voltage output module (30mA/5VDC) * D1-sized controller is fixed to SSR output(G) and no module option provided, i.e. AI-208-D1-G, AI-208-D1-G-L0 or AI-208-D1-G-L5 must be specified upon order. II. TECHNICAL SPECIFICATION 1.

  • Page 4: Front Panel And Operation

    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 III. FRONT PANEL AND OPERATION ① Process Value(PV), or parameter code Set Value(SV), alarming code, or value of a parameter ② Setup key, accessing parameter table, and confirming change.

  • Page 5
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 V. PARAMETER AND SETTING Title Description Range Parameter Field Parameter Table (Press and hold for 2 seconds to access) Alarm on when PV (Process Value) >HIA;…
  • Page 6
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 Smaller value will result in higher control accuracy. For SSR output, generally 0.5 to 3 seconds. For Relay output, generally 15 to 40 seconds, because small value will…
  • Page 7
    Yudian (H.K.) Automation Technology Co. Ltd. Website: http://www.yudian.us http://www.yudian.com.hk Email: sales@yudian.com.hk Tel: +852-2770 8785 Fax: +852-2770 8796 VI. INSTRUMENT INSTALLATION AND WIRING DIAGRAM Panel dimension A1, B1, E1 or F1 Panel dimension A, B, E or F Main Output Alarm Output…

Описание и отзывы

Характеристики

Регулятор температуры PID

Описание продукта:

.JPG

PRODUCT DESCRIPTION

Основные характеристики для регулятора температуры PID Yudian AI-518

  • Универсальные термопары, RTDs и линейные сигналы тока/напряженияВыбираемые, интегрированные Нелинейные градационные столы, Цифровая калибровка и автоматическая нулевая технология, и достижение точного и стабильного измерения.
  • Применение усовершенствованного алгоритма управления искусственным интеллектом AI с функцией автоматической настройки, без перебоев.
  • Поставляется с автоматическим/ручным бескорпусным переключателем и функцией мягкого запуска.
  • Применение передовой модульной структуры, удобно обеспечивая множество вариантов выхода, может удовлетворить различные требования приложения и сделать быструю доставку и легкое обслуживание.
  • Высокое качество и производительность аппаратного дизайна, используя высокопроизводительный танталовый конденсатор или керамический конденсатор. По сравнению с конкурирующими моделями, он потребляет меньше электроэнергии, переживает меньше перегрева температуры, обеспечивает более высокую стабильность и может работать в более широком диапазоне температур.
  • ISO9001 и CE сертифицированы, достигая мирового уровня качества, анти-помехи и безопасности.

Размер для регулятора температуры PID AI-518

Размер Передняя панель (Ш * В) Вырез (Ш * В) Глубина от монтажной поверхности
А 96*96 мм 92*92 мм

100 мм

B 160*80 мм 152*76 мм 100 мм
C 80*160 мм 152*76 мм 100 мм
D 72*72 мм 68*68 мм 95 мм
D2 48*48 мм 45*45 мм 95 мм
E 48*96 мм 45*92 мм 100 мм
F 96*48 мм 92*45 мм 100 мм

519 details_plus

519 key point

Передняя панель и управление для PID регулятора температуры

.JPG 

Упаковка & Доставка

Вы получите:

  1. Контроллер температуры;
  2. Бумага руководства пользователя;
  3. Гарантийный талон на один год/3 года и сертификат качества;
  4. Этикетка единиц;
  5. Пара монтажных кронштейнов;
  6. Хорошая картонная коробка с логотипом Yudian.

Больше продуктов

paste-pic-dp_uuid_a95wm

Похожие товары

Особенности продукта:

Двойной дисплей для установки температуры и температуры процесса

Размер 72*72 мм

Универсальный вход, поддержка 10 различных типов термопар и RTD входов клиентов, выбранных на панелях.

Использует его в управлении нагревом, а также для контроля охлаждения

Функция автоматической настройки может автоматически находить лучшие параметры PID

Отображает температуру в градусах Цельсия (C)

Использует его для печи, инкубатора контроля температуры

Он используется в различных отраслях промышленности для контроля и контроля температуры процесса

Входной Тип

Термопара: K, E, S, R, J, T, B

RTD: Pt100, Cu50

(Пользователь может установить Тип входного сигнала в соответствии с требованиями.)

Входной диапазон

0 ~ + 1300 градусов Цельсия

(Это настройка по умолчанию. Пользователь может установить диапазон температур, который вы хотели.)

Дисплей

Две линии, четыре цифры в градусах Цельсия.

Разрешение дисплея

1 degC, или 0,1 degC, если Pt100 вход

Точность

+/-0.5% или +/-1 блок полного входного диапазона

Режим управления

ПИД, ВКЛ/ВЫКЛ

Контрольный выход

Релейный контакт: 3A при 240 В переменного тока.

Сигнализация

Сигнал тревоги 1 (предельный сигнал смещения, пользователь может изменить другой режим будильника.)

Энергопотребление

<2 Вт

Источник питания

100 ~ 240 В переменного тока, 50/60 Гц.

Габаритные размеры изделия

HD701 72*72*70 мм

Размер монтажного отверстия

HD701 69*69 мм

Инструкция по эксплуатации терморегулятора серии HD

Перед использованием данной продукции, необходимо внимательно ознакомиться с содержанием инструкции, чтобы знать как правильно использовать устройство. Кроме того, рекомендуем хранить данную инструкцию надлежащим образом и по мере необходимости обращаться к ее содержанию.  

Предупреждение

• Предупреждение по подключению

— Если устройство не исправно или в его работе возникла ошибка, это может привести к неисправности всей системы. Установите защитную цепь внешней части, чтобы предотвратить возникновение неисправностей данного типа.     

— Чтобы предотвратить выход из строя или повреждение устройства, выберите подходящий предохранитель для защиты питающего провода и входных/выходных проводов, во избежании сильного удара током.

• Подача источника питания

— Чтобы предотвратить выход из строя или повреждение устройства, используйте подачу электропитания с номинальным напряжением.

— Во избежании поражения электрическим током или поломки устройства, подачу электроэнергии можно запускать только после завершения всех работ на линии.

• Запрещено использовать данное устройство вблизи легковоспламеняющихся газов.

— В целях предотвращения возникновения пожара, взрыва или повреждения устройства, запрещено вести его эксплуатацию в местах, где имеются легковоспламеняющиеся, взрывоопасные газы и где осуществляется стравливание пара.

• Строго запрещено касаться внутренних частей устройства.

— Во избежание поражения электрическим током или возникновения возгорания, строго запрещается касаться внутренних частей устройства. Только инженер по техническому обслуживанию нашего завода может проводить проверку электропроводки внутренних частей или производить замену элементов, так как во внутренней части устройства имеются элементы, находящиеся под высоким напряжением и имеющие высокую температуру. Очень опасно!

• Строго запрещено вносить изменения в  устройство.

— Чтобы предотвратить возникновение аварии или повреждения устройства, строго запрещено вносить в него изменения.

• Техническое обслуживание

— Во избежании поражения электрическим током, повреждения или выхода из строя устройства, осуществлять замену его элементов и частей может только инженер по техническому обслуживанию нашего завода.

— Для обеспечения продолжительного срока службы и безопасной эксплуатации устройства, необходимо регулярно проводить его техническое обслуживание, так как при продолжительном сроке эксплуатации некоторые элементы внутри устройства могут быть повреждены.    

Указания по работе

• Осуществлять очистку устройства можно только после отключения его от электричества.

• Для очистки пятен с дисплея используйте мягкую ткань или хлопковую бумагу.  

• Дисплей устройства легко подвержен образованию царапин, поэтому запрещено касаться его твердыми предметами и использовать их для его очистки.

• Запрещено использовать твердые и острые предметы, такие как отвертка или шариковая ручка для работы с кнопками на панели управления, в противном случае кнопки можно повредить или поцарапать.

1. Общие сведения

Интеллектуальный терморегулятор серии HD представляет собой многофункциональное регулирующееся устройство со специальным микропроцессором. Для него используется импульсный источник питания и технология поверхностного монтажа (SMT), поэтому устройство является точным и компактным, а также обладает надежными характеристиками. Он имеет уникальную функцию самодиагностики, функцию интеллектуального управления самонастройками. Данные функции позволяют оператору с помощью несложного управления получить хорошие результаты.

Основные особенности

Термоэлемент, терморезистор, свободный ввод аналоговых сигналов и других сигналов разного вида, свободная установка пределов, регулировка нуля и полного диапазона с помощью программного обеспечения, самостоятельное измерение температуры холодного спая, самостоятельная стабилизация усилителя на ноль, точность отображения лучше на 0.5% FS (от полного размера).

Теория нечетких множеств сочетается с традиционным способом PID, быстрое и стабильное управление, усовершенствованные способы настройки.

Опционный выход/по выбору/для: контакты прерывателя тока, логический электрический уровень, тиристорное однофазное или трехфазное прохождение через ноль или пусковой импульс фазового сдвига, аналоговая величина. Два дополнительных определяемых контактных выходов для сигналов.

2. Основные технические показатели

2.1 Вход

Различные термоэлементы (ТС), стандарт терморезисторов (RTD)

Сигнал для напряжения и электрического тока (смотрите Таблицу типов выхода)

2.2 Основная погрешность: ± 0.5% ± 1 знак от введенного полного диапазона

2.3 Коэффициент разрешения: 1 ºС, 0.1 ºС       

2.4 Период дискретизации: 3 раза/сек.

2.5 Функции сигнала: верхний предел, нижний предел, верхнее отклонение, нижнее отклонение, в пределах интервала, вне интервала

2.6 Выход сигнала: контакт реле АС250V 3А (омический)

2.7 Выход управляющего сигнала: контакт реле АС250V 3А (омический)

Логический уровень: DC 0/12 V (подходит для твердотельного реле SSR)

Пусковой импульс, срабатывающий при переходе сигнала через ноль: оптроный тиристорный выход 1A600V

0-10 мА выходной ток (значение сопротивления нагрузки менее 600Ω)

0-20 мА выходной ток (значение сопротивления нагрузки менее 600Ω)

4-20 мА выходной ток (значение сопротивления нагрузки менее 600Ω)

2.8 Способ регулирования: нечеткое управление PID, пошаговое управление

2.9 Напряжение источника электропитания: АС85-264V (50/60 Гц)

(номинальное 100=240 В АС)

21.6-26.4 В АС (номинальное 24 В АС)

21.6-26.4 В DС (номинальное 24 В DС)

2.10 Рабочие условия: место с отсутствием коррозийной активности, температурой 0-50 ºС,

влажностью <85%RH (относительная влажность). Потребляемая

мощность<5VA.

2.11 Размеры панели: 80х160, 160х80, 96х96, 72х72, 96х48, 48х96, 48х48 мм

Таблица диапазонов входа

(Таблица 1)

Термоэлемент

Вход

Диапазон

Код

Диапазон

Код

Диапазон

Код

K

0~200 °C

K01

0~400 °C

K02

0~600 °C

K03

0~800 °C

K04

0~1000 °C

K05

0~1200 °C

K06

0~1372 °C

K07

0~100 °C

K13

0~300 °C

K14

J

0~200 °C

J01

0~400 °C

J02

0~600 °C

J03

0~800 °C

J04

0~1000 °C

J05

0~1200 °C

J06

R#1

0~1600 °C

R01

0~1769 °C

R02

0~1350 °C

R04

S#1

0~1600 °C

S01

0~1769 °C

S02

B#1

400~1800 °C

B01

0~1769 °C

B02

E

0~800 °C

E01

0~1000 °C

E02

N

0~1200 °C

N01

0~1300 °C

N02

T#2

-199.9~400.0 °C

T01

-199.9~400.0 °C

T02

-100.0~200.0 °C

T03

0~350 °C

T04

Терморезистор

Pt100

-199.9~649.0 °C

D01

-199.9~200.0 °C

D02

-100~50.0 °C

D03

-100~100 °C

D04

-100~200 °C

D05

0.0~50.0 °C

D06

0.1~100 °C

D07

0.0~200.0 °C

D08

0~300.0 °C

D09

0.0~500 °C

D10

0.0~400.0 °C

D20

CU50

-50.0~150.0 °C

C01

0.0~150.0 °C

C02

-100~50.0 °C

C03

0.0~150 °C

C04

-50.0~100.0 °C

C05

0.0~50.0 °C

C06

-50~150 °C

C07

0~150 °C

C08

0~300.0 °C

C09

0~50 °C

C10

0~5V

0.0~100 °C

401

1~5V

0.0~100 °C

604

0~20мА#3

0.0~100 °C

701

4~20мА#3

0.0~100 °C

801

                 

#1 В диапазоне 0~900 °C гарантия точности отсутствует 

#2 В диапазоне -199.9-100 °C гарантия точности отсутствует

#3 Между входными клеммами необходимо присоединить 250Ω резистор

Таблица с первым сигналом [ALM1] (стандартный, встроенный)

и вторым сигналом (опционный)

(Таблица 2)

А: Сигнал отклонения верхнего предела

G: Сигнал отклонения верхнего, нижнего пределов в режиме ожидания

В: Сигнал отклонения нижнего предела

H: Сигнал входной величины верхнего предела

С: Сигнал отклонения верхнего, нижнего пределов

J: Сигнал входной величины нижнего предела

D: Сигнал в пределах диапазона

K: Сигнал входной величины верхнего предела в режиме ожидания

E: Сигнал отклонения верхнего предела в режиме ожидания

L: Сигнал входной величины нижнего предела в режиме ожидания

F: Сигнал отклонения нижнего предела в режиме ожидания

       

Примечание: при оформлении заказа, необходимо подробно заполнить данные, в соответствии с вышеуказанным содержанием

4. Монтаж

4.1 Особые указания

(1) Монтаж устройства необходимо производить в следующих условиях среды:

• Атмосферное давление: 86-106 кПа.

• Температура окружающей среды: 0~50 °C

• Относительная влажность: 45~85%RH (относительная влажность) 

(2) При монтаже следует учесть следующие условия

• Быстрое изменение влажности среды может привести к образованию конденсации. 

• Коррозионные, легковоспламеняющиеся газы. 

• Прямая вибрация или удары по несущей конструкции.

• Вода, масло, химические продукты, дым или паровое загрязнение.

• Избыток пыли, засоленность или металлические порошки.

• Прямой поток воздуха от кондиционера.

• Прямой солнечный свет.

• Накопление теплового излучения извне.

4.2 Процесс монтажа

(1) Исходя из размеров отверстия на панели, сделайте прямоугольное/квадратное

отверстие на панели устройства для проведения его монтажа.

(2) При монтаже нескольких устройств, расстояние между правым и левым отверстиями

должно быть более 25 мм; расстояние между верхним и нижнем отверстиями должно

составлять более 30 мм.

(3) Вставьте устройство в открытое отверстие на панели. 

(4) Вставьте монтажный кронштейн в пределы установки устройства.

(5) Вплотную прижмите монтажный кронштейн, чтобы устройство и панель прочно

соединились, затяните винты.   

Таблица габаритных размеров и размеров отверстий на панели:

Единицы измерения: мм

Модель

Габаритные размеры,

высота Х ширина Х длина

Размер отверстия,

высота Х ширина

HD801

80 x 160 x 78

(76+1) x (152+1)

HD161

160 x 80 x 78

(152+1) x (76+1)

HD901

96 x 96 x 78

(92+1) x (92+1)

HD701

72 x 72 x 78

(68+1) x (68+1)

HD501

96 x 48 x 78

(92+1) x (45+1)

HD401

48 x 96 x 78

(45+1) x (92+1)

HD101

48 x 48 x 78

(45+1) x (45+1)

         

5. Подключение

5.1 Особые указания по подключению

(1) Для входа термоэлемента необходимо использовать соответствующий компенсационный провод.

(2)  Для входа терморезистора, необходимо использовать 3 любых низкоомных питающих провода.

(3) Входной сигнальный провод должен находиться вдалеке от питающих проводов устройства, динамических питающих проводов и нагрузочной линии, чтобы избежать образования помех и интерференции.

(4) Питающий провод устройства, как правило, не создает помех для динамических питающих проводов.

Когда на устройство воздействуют внешние помехи, необходимо использовать помехоподавляющий фильтр.  

Сокращайте шаг скручивания питающего провода: чем короче расстояние, тем меньше создается помех.

• На приборную панель установите помехоподавляющий фильтр и заземлите его. Также

необходимо сократить расстояние между выходом фильтра и клеммами источника

электропитания устройства.

• Не устанавливайте предохранители и переключатели на выходных клеммах, так как их

установка может привести к сокращению эффективности фильтра.

(5) Соединительные провода должны соответствовать государственным стандартам всех

стран. В качестве питающих проводов необходимо использовать 600В провода с ПВХ-

изоляцией (JISC3307).

(6) После подключения к источнику электропитания, время для подготовки устройства к

релейному выходу займет 5-6 секунд. При использовании в качестве внешней

соединительной электроцепи и других сигналов, одновременно необходимо применять 

реле замедленного действия.

(7) Данное устройство не оснащено силовым выключателем и предохранителем. При

необходимости можно дополнительно установить предохранитель со следующими

рекомендуемыми характеристиками: номинальное напряжение: 250 В, номинальный

электрический ток: 1 А, модель предохранителя: замедленный предохранитель

(8) Не перетягивайте винты клемм. Кроме того, используйте подходящие клеммные болты и

наконечники (модель винтов М3х6, рекомендуемый момент силы: 0.4 Нм) [4kgf.cm].

5.2 Конструкция клемм (пример)

Схема электрических соединений (в качестве стандарта  используется схема электрических соединений данного устройства).


6. Наименование частей панели

 №

Описание панели

Описание содержания

1.

PV

Значение измерения Отображаемое значение

режима

2.

SV

Установленное значение Отображаемое значение

содержания режима

3.

OUT1

Выход индикатора 1

4.

OUT2

Выход индикатора 2

5.

AT

Световой индикатор автоматического вычисления

PID

6.

ALM1

Световой индикатор сигнала 1

7.

ALM2

Световой индикатор сигнала 2

8.

Кнопка «увеличить»

9.

Кнопка «уменьшить»

10.

Кнопка перемещения

11.

SET

Кнопка режима, установки

7. Описание работы

7.1 Последовательность вызова каждого режима

1. Подключите к источнику электропитания

2. Отображение типа входа

Отображение диапазона входа

3. (отображается около 5 секунд)

4. Автоматическое переключение

5. Режим отображения PV/SV

(стандартное отображение)

6. Режим установки SV

7. Режим установки параметров

* 1 Отображение типа входа и диапазона входа

После подключения к электрической сети, можно сразу определить тип и диапазон входа.

Например: вход термоэлемента К, 0-1372 ºС

 

j Код типа входа

Шифр входного типа (смотрите Таблицу)

Отображает единицы измерения температуры (соответствует F: F

k Отображение диапазона входа

* Нажмите кнопку SET, чтобы войти в режим установки SV.  

** В режиме установки SV, если кнопка не используется более 15 секунд, то устройство вернется в режим PV/SV. Измененные данные будут подтверждены.    

*** Чтобы войти в режим установки параметров, удерживайте нажатой кнопку SET более 5 секунд.

**** В режиме установки параметров, если кнопка не используется более 20 секунд, то устройство вернется в режим PV/SV.

Таблица типов входов (Sn)

Изображение

Тип входа

Термоэлемент (ТС)

Терморезистор

Электрическое напряжение

Электрический ток

K

J

R

S

B

E

N

Т

Pt100

JPt100

Cu50

mV

(мВ)

mA

(мА)

V

(В)

7.2 Подробное описание функций каждого режима

■ Режим отображения PV/SV

Отображение значений измерений (PV) на дисплее и установленных значений (SV) на дисплее SV. Кроме изменения установленных значений (SV), изменение числовых значений каждого параметра, как правило, осуществляется в данном положении режима.

Режим установки SV

В режиме стандартного отображения SV/ PV, нажмите кнопку «SET», чтобы отображение перешло в режим мигания. Нажимая на кнопку «<», найдите необходимое количество знаков установленной температуры. Вновь нажмите на кнопку «увеличить» или «уменьшить», чтобы установить необходимое значение температуры. После завершения установки, повторно нажмите кнопку «SET», чтобы индикатор перешел в режим стандартного отображения SV/ PV.   

Режим установки параметров

Данные параметры используются для установки сигналов, постоянной величины PID и других параметров. В режиме стандартного отображения SV/ PV, удерживайте нажатой кнопку «SET» в течение 3 секунд. Далее, на дисплее PV отобразится режим установки параметров. Его соответствующее значение отобразится на дисплее SV. Поочередно нажимайте на кнопку «SET», чтобы отобразились параметры из таблицы:

Внимание:

Данное устройство имеет функцию автоматического восстановления. Когда оператор выполняет операцию изменения настроек параметров и забывает вернуться в режим основного отображения, индикатор автоматически возвращается в этот режим через 30 секунд.  

Перед использованием устройства или при изменении параметров, внимательно прочитайте следующую информацию.

Далее приведена информация по каждому пункту технологического процесса. Если устройство не имеет данной функции, то ее содержание не будет отображаться.

Отображаемый символ

Наименование

Пояснение

Установленный диапазон

Значение при выпуске с завода

AL1

Установка сигнала 1-й группы

Установите заданное значение первого и второго сигналов

Полный диапазон

50.0 или 50

AL2

Установка сигнала 2-й группы

Заданное значение

Полный диапазон

50.0 или 50

ATU

Самонастройка

Подтвердите выполнение/отключение самонастройки

0: самонастройка отключена

1: самонастройка включена

0

STU

Самостоятельная корректировка

Подтвердите выполнение/отключение самостоятельной корректировки

0: самостоятельная корректировка отключена или остановлена

1:  самостоятельная корректировка запущена

0

Р

Зона пропорциональности (сторона нагрева)

Установите размер зоны пропорциональности

0 — полный диапазон

При установке 0, управляется с помощью ON/OFF

30 или 3.0 смотрите *1

I

Время интегрирования (секунды)

Установите время интегрирования, для устранения остаточной погрешности пропорционального управления

0-3600 (секунд)

При установке на 0, интегральное действие отсутсвует

240

D

Время дифференцирования (секунды)

Установите время дифференцирования, чтобы предотвратить выходную пульсацию

0-3600 (секунд)

При установке на 0, действие дифференцирования отсутсвует

60

Ar

Ограничение эффективного диапазона интегрального действия

Предотвращает избыточную недостаточность в соответствии с интегральным действием

1-100% зоны пропорциональности (сторона нагрева)

25

T

Цикл пропорциональности (секунды)

Установите регулируемый цикл действия, цикл пропорциональности стороны нагрева

Диапазон 1-100 (секунд) (не может равняться 0), не отображается при выходном токе

(смотрите *3)

Pc

Зона пропорциональности (сторона охлаждения)

Установите размер зоны пропорциональности стороны охлаждения

1-100% (сторона охлаждения)

100

Db

Зона отсутствия чувствительности

Установите промежуток между зонами пропорциональности (стороны нагрева) и (стороны охлаждения), чтобы контролировать действие зоны отсутствия чувствительности. Установка отрицательного значения означает удвоение

Температура на входе -10~+10 или -10.0~+10.0

-10.0~+10.0% полного диапазона напряжения электрического тока и напряжения

0 или 0.0

T

Цикл пропорциональности (сторона охлаждения)

Установите регулируемый цикл стороны охлаждения

1-100 сек. (не может быть установлено на значение 0), не отображается при выходном токе

(смотрите *3)

Pb

Отклонение в значении хода

Складывается значение, измеренное датчиком и текущее значение, получается значение PV

Температура на входе -1999~+9999 или -199.9~+999.9

электрическое напряжение/электрический ток на входе ± единицы измерения диапазона равны (PV)

0 или 0.0

LCK

Установка функции блокировки данных

Делает изменение данных эффективно/не эффективно

Смотрите *4

0000

*1. Когда P≠0, устройство контролируется PID, в это время необходимо рационально установить каждое значение ‘I,  D’. При первом использовании можно запустить функцию самонастройки ‘АТ’, чтобы управление находилось в оптимальном состоянии. Когда Р=0, управление осуществляется посредством ON/OFF, в это время необходимо установить значение управления возвратной разностью на ‘ОН’.

*2. Выход контакта прерывателя тока: 20 секунд, импульсный выход напряжения (SSR) триггер тиристора, срабатывающий при переходе сигнала через ноль (SCR) 2 секунды

*3. Выбор уровня блокировки данных

Функция блокировки данных используется для предотвращения неправильной работы некоторых параметров, которые редко устанавливаются. После блокировки параметра, его нельзя настраивать или изменять, можно только отслеживать.

Конфигурация

Диапазон защиты блокировки всех уровней

0000

Можно установить SV и все имеющиеся параметры

0001

Можно установить только SV, AL1, AL2

0011

Можно установить только SV

0111

Нельзя установить SV и все имеющиеся параметры

8. Отображение возникших неисправностей

Когда устройство не может работать в нормальном режиме, после осуществления его самодиагностики, на дисплей выводиться сообщение с подсказкой.

Сообщение

Описание

Способ устранения

Err

Устройство не исправно

Необходимо отправить на осмотр и ремонт

oooo

Обрыв провода на входе

Неправильное соединение полярностей или превышение входа

Необходимо проверить имеется ли ошибка сигнала на входе

uuuu

Обрыв провода на входе

Неправильное соединение полярностей или превышение входа

Необходимо проверить имеется ли ошибка сигнала на входе

Установка режима технических параметров устройства

После подключения к электросети устройства, через режим установки параметров, введите или найдите параметры данных «LCK», установите его код как «1000», повторно нажмите кнопку «SET», чтобы подтвердить устройство. Одновременно нажмите две кнопке: «SET» и «<», удерживайте в течение 3 секунд. После того, когда на дисплее PV отобразится «Cod» =0000, поочередно нажимайте кнопку «SET». Можно получить и периодически выводить на дисплей следующие параметры:

Отображаемый символ

Установленное значение

Описание

Диапазон пределов

SL1

0

0

0

0

K

0~1372ºC

0

0

0

1

J

0~1200ºC

0

0

1

0

L

-200~400ºC/199.9~400ºC

0

0

1

1

E

0~800ºC

0

1

0

0

N

0~1300ºC

0

1

1

1

R

0~1769ºC

1

0

0

0

S

0~1769ºC

1

0

0

1

B

0~1820ºC

1

1

0

0

Pt100

-200~650ºC/-19909~650.0ºC

1

1

0

1

CU50

-50~150ºC/-50.0~150.0ºC

1

1

1

0

0~20 мА

-1999~9999

1

1

1

0

4~20 мА

-1999~9999

1

1

1

1

0~5 В

-1999~9999

1

1

1

1

1~5 В

-1999~9999

SL2

0

0

0

0

Без деталей

SL3

0

0

0

0

Без деталей

SL4

0

0

0

Не установлена функция сигнала первой группы

Выбор первого типа сигнала (ALM1)

0

0

1

Сигнал отклонения верхнего предела

0

1

0

Сигнал отклонения верхнего/нижнего предела

0

1

1

Сигнал значения процесса  верхнего предела

1

0

1

Сигнал отклонения нижнего предела

1

1

0

С сигналом (сигнал внутри зоны)

1

1

1

Сигнал значения процесса  нижнего предела

0

Нет функции сигнала в режиме ожидания

Выберите функцию первого сигнала в режиме ожидания

1

Есть функция сигнала в режиме ожидания

SL5

0

0

0

0

Установка функции сигнала второй группы

Совпадет с первым сигналом

SL6

0

Управление прямым действием (охлаждение)

Выбор основного управления прямым/обратным действием

1

Управлением обратным действием (нагрев)

0

Время основного контроля пропорционального выхода

Выбор типа выхода основного контроля

1

Основной контроль непрерывного выхода (4~20 мА)

SL7

0

Сигнал возбуждения тока

Сигнал возбуждения тока/сигнал отсутствия возбуждения тока

1

Сигнал отсутствия возбуждения тока

(Сторона первого сигнала)

0

Сигнал возбуждения тока

Сигнал возбуждения тока/сигнал отсутствия возбуждения тока

1

Сигнал отсутствия возбуждения тока

(Сторона второго сигнала)

SL8

0

0

0

0

Без деталей

SL9

0

0

0

0

Без деталей

SL10

0

0

0

0

Без деталей

SL11

0

0

0

0

Без деталей

Когда «Cod» =0001, поочередно нажимайте кнопку «SET». Можно получать и периодически выводить на дисплей следующие параметры:

Отображаемый символ

Значение при выпуске с завода

Описание

Установленный диапазон

SLH

В соответствии с заказанным товаром

Верхний предел диапазона измерения заданного значения

Смотрите таблицу выше

SLL

В соответствии с заказанным товаром

Нижний предел диапазона измерения заданного значения

Смотрите таблицу выше

PGdP

0

Количество десятичных знаков

0-3

OH

2 или 2.0

Ширина самонастраивающейся полосы выхода пропускания несрабатываний АТ

0-100 или 0.1-100.0

AH1

2 или 2.0

Ширина полосы пропускания выхода несрабатываний первого сигнала

0-100 или 0.1-100.0

AH2

2 или 2.0

Ширина полосы пропускания выхода несрабатываний второго сигнала

0-100 или 0.1-100.0

CTr

800

Коэффициент трансформатора тока

0~9999

dF

1

Коэффициент цифровой фильтрации

0-100

STTM

100

Коэффициент времени для стабилизации измеренного значения

0~200

STPK

67

Коэффициент расчета зоны пропорциональности

0~200

STIK

16

Коэффициент интегрального вычисления

0~200

Инструкция

Понравилась статья? Поделить с друзьями:
  • Uccnc программа инструкция на русском
  • Two per day multivitamin инструкция по применению на русском
  • Ucrete mf 40 as инструкция
  • Twinrey аппарат для ухода за лицом инструкция цена
  • Ua jbl tws streak инструкция