Вентилятор дельта напольный инструкция по сборке

VENTILATION FAN / LED LIGHT

MODELS 150F/150LEDNL/150LED-ADJ/150DS

READ AND SAVE THESE INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS

GENERAL SAFETY INFORMATION

GENERAL SAFETY INFORMATION

1. Make sure that the electric service supply voltage

is AC 120V, 60Hz.

2. Follow all local electrical and safety codes, as well

as the National Electrical Code (NEC) and the

Occupational Safety and Health Act (OSH Act).

3. Always disconnect the power source before

working on or near the ventilating fan, motor or

junction box.

4. Protect the power cord from sharp edges, oil,

grease, hot surfaces, chemicals or other objects.

5. Do not kink the power cord.

6. Do not install the unit where ducts are configured

as shown in Fig.A.

7. Provide suction parts with proper ventilation.

8. This unit is UL Listed for use over a bathtub or

shower when installed in a GFCI protected branch

circuit.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC

SHOCK, OR INJURY TO PERSONS, OBSERVE THE

FOLLOWING:

1. Use this unit only in the manner intended by the

manufacturer. If you have questions, contact the

manufacturer.

2. Before servicing or cleaning the unit, switch the

power off at the service panel and lock the service

disconnecting means to prevent the power from

being switched on accidentally. When the service

disconnecting means cannot be locked, securely

fasten a prominent warning device, such as a tag,

to the service panel.

3. Installation work and electrical wiring must be done

by a qualified person(s) in accordance with all

applicable codes and standards, including fire-rated

construction.

4. Sufficient air is needed for proper combustion and

exhausting of gases through the flue (chimney) of

fuel burning equipment to prevent backdrafting.

Follow the heating equipment manufacturer’s

guideline and safety standards such as those

published by the National Fire Protection

Association (NFPA), and the American Society of

Heating, Refrigeration and Air-Conditioning

Engineers (ASHRAE) and local code authorities.

5. When cutting or drilling into the wall or ceiling, do

not damage electrical wiring and other hidden

utilities.

6. Ducted ventilating fans must always be vented to

the outdoors.

7. If this unit is to be installed over a tub or shower, it

must be marked as appropriate for the application

and be connected to a GFCI (Ground Fault Circuit

lnterrupter) – protected branch circuit.

8. Do not use this unit with any other solid-state

control device. Solid-state control device may

cause harmonic distortion, which can cause a

motor humming noise.

(Avertissement: ne convient pas à des régulateurs

de vitesse à semi-conducteurs).

9. NEVER place a switch where it can be reached

from a tub or shower.

10. Not to be installed in a ceiling thermally insulated to

a value greater than R50. (This is required for

installation in Canada only).

11. Do not open/disassemble LED light engine.

MFG MODELS: VFB150E6A1 / VFB150E6LED1 / VFB150E6LED1-A / VFB150E6D1

Turning angle too large

Too many elbows

Elbow near the body

Fig. A

CAUTION

1. For general ventilating use only. Do Not Use To

Exhaust Hazardous Or Explosive Materials And

Vapors.

2. Not for use in cooking areas. (Fig.B)

3. This product must properly connect to the

grounding conductor of the supply circuit.

4. To reduce the risk of injury to persons, install the

fan at least 8.2 feet (2.5m) above the floor.

Cooking area

Do not install above or

inside this area

Cooking

Equipment

Fig. B

PREPARATION

Tools Required for Assembly (not included): Hammer,

Flathead Screwdriver, Wire Nuts, Nails, Duct Tape,

Phillips Head Screwdriver, Utility Knife

Helpful Tools (not included): Electric Drill, Drill Bits

WARNING: Turn off electricity at breaker box

before beginning installation.

Carefully remove unit from carton.

Check area above installation location to be sure

that wiring can run to the planned location and

that duct work can be run. Make sure the area is

sufficient for proper ventilation.

Inspect duct work and wiring before proceeding

with installation.

Before installation, provide inspection and future

maintenance access at a location that will not

interfere with installation work.

You may need the help of a second person to

install this fan: one person on the attic side and

one on the room side.

Note: Installations may vary depending on how the

previous bath fan was installed. Supplies necessary

for the installation of your bath fan are not all included.

However, most are available at your local home

improvement or hardware store.

Proper insulation around the fan to minimize building

heat loss and gain. 6 in. circular duct is recommended

for installation. The ducting from this fan to the

outside of building has a strong effect on air flow,

noise and energy use of the fan. Use the shortest,

1

Installation and Operating Instructions

straightest duct routing possible for best performance,

and avoid installing the fan with smaller ducts than

Duct shrink

recommended. Insulation around the ducts can reduce

energy loss and inhibit mold growth. Fans installed with

existing ducts may not achieve their rated air flow.

Short piece of flexible

duct helps alignment

and absorbs sound

Body

Fan housing

Minimum 18 in.

.

Seal gap

around

housing

The fan will operate most efficiently when located

where the shortest possible duct run and minimum

number of elbows will be needed.

Use a roof cap or wall cap that has a built-in

damper to reduce backdrafts.

External timer can be used in conjunction with single

speed mode only, please contact Delta Breez

customer service and consult with a licensed

electrician for compatibility.

External dimmer can be used in conjunction with

LED light model, please contact Delta Breez

customer service and consult with a licensed

electrician for compatibility.

PACKAGE CONTENTS

PART NAME

Fan Body

Grille

Grille

Hanger BarⅠ

13″(318.5mm)

Hanger BarⅡ

13″(318.5mm)

Duct Connector

(6″)

Roof cap

(with built-in

damper)

or

Wall cap

Wall cap

(with built-in

(with built-in

2~3 ft straight run

Caulk termination

damper)

damper)

before elbow

to duct

APPEARANCE

150F / 150DS

150LEDNL / 150LED-ADJ

QTY

1

1

1

2

2

1

Вентилятор напольный с увлажнителем воздуха DELTA DL-024H черный

Вентилятор напольный с увлажнителем воздуха DELTA DL-024H черный

  • Торговая марка: DELTA

  • Узнать цену

  • Параметры

    • Номинальная потребляемая мощность вентилятора
      260 Вт
    • Частота вращения двигателя вентилятора
      1400 об/мин
    • Понижение температуры в зоне действия
      8-10°С
    • Объем воздушного потока, куб.м/ч
      10000-14800
    • Площадь эффективного увлажнения
      40-50 куб.м
    • Объем резервуара для воды
      41 л
    • Максимальный расход воды
      5 л/ч
    • Номинальная потребляемая мощность насоса
      18 Вт
    • Частота вращения двигателя насоса
      2600 об/мин
    • Номинальная производительность насоса
      900 л/ч
    • Максимальный напор
      1,8 м
    • Материал лопастей
      алюминий
    • Угол поворота вентилятора
      0-90°
    • Диаметр
      660 мм
    • Высота регулируемая
      1,7-2,0 м
    • Вес нетто/брутто
      31/34 кг
    • Уровень шума
      60 дБ
  • Описание

    • Предназначен для использования только в бытовых целях для вентиляции, увлажнения и очищения воздуха в помещениях, таких как: мастерские, помещения для скота, зимние сады, теплицы
    • Прибор позволит улучшить качество жизни и создать здоровый микроклимат в окружающем пространстве
    • Увлажнение воздуха вентилятором происходит по принципу центробежного мелкокапельного распыления воды потоком воздуха. Испаряясь, влага понижает температуру, увлажняет и освежает воздух, уменьшает количество пыли в помещении
    • Защитные сетки — 1 комплект
    • Шланг гофрированный — 1 штука
    • Удобные ролики для перемещения — 2+2 штуки
    • Комплект креплений
    • 2 режима работы:
    • режим вентиляции
    • режим увлажнения
    • 3 скоростных режима
    • Регулировка высоты вентилятора
    • Регулятор наклона вентилятора до 30°
    • Не требует системы фильтрации воды
    • Простота сборки и эксплуатации
    • ВНИМАНИЕ! Вентилятор поставляется в 3-х (трех) коробках:
    • Коробка №1 — вентилятор
    • Коробка №2 — стойка вентилятора с панелью управления
    • Коробка №3 — система увлажнения и двигатель вентилятора

С этим товаром рекомендуем также посмотреть:

  1. Сборка вентилятора Saturn ST-FN8281 — Продолжительность: 9:38

    Это сборка вентилятора Saturn ST-FN8281, вентилятор ARCTIC Air ARH-5/555 собирается точно так же. Увеличивайте …

  2. Ремонт напольных вентиляторов — Продолжительность: 32:25

    При увеличении емкости конденсатора двигатель начинает запускаться принудительно тоесть от вращения…

  3. Рекомендации на основе вашей истории поиска

    • Мощные вентиляторы с Алиэкспресс — Продолжительность: 16:23

      Получил посылку с мощными вентиляторами 120 мм, 12 Вольт 1,24 Ампера — удачная покупка. Проверка работоспосо…

    • вентилятор — Продолжительность: 3:39

      Фрагмент программы «зеленый огурец». Сюжет о вентиляторах озвучен Ольгой. Маркиной.

  4. Запросы, похожие на как собрать вентилятор delta

  5. Вентилятор Дельта 6038 DC 12 В 3.30A — Продолжительность: 2:24

    Обзор и распаковка с сайта AliExpress, незабываем забрать кэшбэк ………………………………………………………………………………

Понравилась статья? Поделить с друзьями:
  • Велосипед супер формула трехколесный инструкция
  • Вебасто термо топ эво 4 инструкция
  • Вентилятор витек аэро 2 инструкция по применению для человека
  • Вертекс таблетки инструкция по применению цена антибиотик
  • Вессел дуэ ф капсулы 250 ле 60 шт инструкция по применению