TriScanner
Stud & Metal Locator with AC Warning
The Zircon TriScanner
®
Pro SL
scanner detects wood or metal
studs, metal pipes, and hot
Metal Sensor
electrical wires in interior walls,
floors, and ceilings, as well as
AC LED
rebar in concrete. It features
the SpotLite
®
Pointing System,
Stud Scan
three different scanning modes
Mode LED
plus continuous hot electrical
wire detection.
Stud DeepScan
Mode LED
Metal Scan
Mode LED
On/Off Button
(Side of unit)
LIMITED 1 YEAR WARRANTY
Zircon Corporation, («Zircon») warrants this product to be free from defects
in materials and workmanship for one year from the date of purchase. Any
in-warranty defective product returned to Zircon*, freight prepaid with proof
of purchase date and $5.00 to cover postage and handling, will be repaired or
replaced at Zircon’s option. This warranty is limited to the electronic circuitry
and original case of the product and specifically excludes damage caused by
abuse, unreasonable use or neglect. This warranty is in lieu of all other
warranties, express or implied, and no other representations or claims of any
nature shall bind or obligate Zircon. Any implied warranties applicable to this
product are limited to the one year period following its purchase.
IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR
MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that:
(i) some states do not allow limitations on how long an implied warranty lasts
and/or the exclusion or limitation of incidental or consequential damages, so
the above limitations and/or exclusions may not apply to you, and further (ii)
SCANNING IN METAL MODE
Metal can be detected up to 1
1
⁄
in. (38 mm) deep
2
in walls and up to 3 in. (77 mm) deep in concrete.
While holding in On/Off
12
button, slowly move unit
on surface, to locate targets.
Reverse directions to locate other
edge of target. Lights will indicate
metal in the same way as in find-
ing studs. When tone sounds,
LEDs light up, and SpotLite comes on, you are close
to metal. Mark this spot to help ensure that you’re
not nailing into a pipe.
CONTINUOUS AC VOLTAGE
DETECTION
The TriScanner Pro SL detects from 90 to 250 V
13
at 50 to 60 Hz AC in a HOT unshielded
electrical wire that is within 1
1
⁄
in. (38 mm) of
2
wall surface. The voltage detection feature works
continuously in all modes. The sensor is located in the
center of the back of the unit.
Caution: The TriScanner Pro SL will not detect hot
wires inside metal pipe or metal conduit, behind
metallic wall covering, or behind some plywood or
other dense materials. Use extra caution in these
construction situations. Always turn the power
off when nailing, cutting, or drilling near
electrical wires.
VERIFYING IF THE UNIT WORKS
Turn unit on in the air.
14
If the LEDs light when
you bring your hand up to the
back, then the unit is working
properly.
The AC LED should
15
light with an electrical
cord an inch or two away.
®
Pro SL
®
SpotLite
Pointing System
®
TRISCANNER
PRO SL
this warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
Return product freight prepaid with proof of purchase date (dated sales
receipt) and $5.00 to cover postage and handling, to:
Zircon Corporation
*Attn: Returns Department
2390 Boswell Road, Suite 300
Chula Vista, CA 91914-3510 USA
Be sure to include your name and return address. Out of warranty service and
repair, where proof of purchase is not provided, shall be returned with repairs
charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-866-8600
Monday–Friday, 8 a.m. to 5 p.m. PST
E-mail: customer.service@zircon.com
U.S. Patent #4464622, 5352974, 5619128, 6023159, 6249113, 6259241,
D419546, D419149, D419545, D427166, and D419544
Canada Patent #1106932 • G.B. Patent #2117909B, 2159630B
©2002 Zircon Corporation • P/N 58756 • Rev B 11/02
OPERATING CAUTIONS
Depending on the proximity of electrical wiring
16
or pipes to the wall surface, the scanner may
detect them in the same manner as studs. Caution
should always be used when nailing, cutting, or
drilling in walls, floors, and ceilings that may contain
these items.
To avoid surprises, remember that studs or joists are
normally spaced 16 in. (406 mm) or 24 in. (610 mm)
apart and are 1
1
⁄
in. (38 mm) in width. Anything
2
closer together or a different width may not be a
stud, joist, or firebreak. Always turn off the power
when working near electrical wires.
WORKING WITH DIFFERENT MATERIALS
Wallpaper: TriScanner Pro SL functions normally on
walls covered with wallpaper or fabric, unless the
materials are metallic foil, contain metallic fibers, or
are still wet after application.
Textured Ceilings: When scanning on an uneven
surface, place thin cardboard on ceiling and scan over
the cardboard. Calibrate with cardboard in place.
Note: TriScanner Pro SL cannot scan through
carpeting and pad or, in most cases, lath and plaster.
If you are having difficulty scanning through any of
these or other materials, use the Metal mode to
locate nails in the stud or joist. Try to locate several
nails to get a better idea of how the stud is oriented.
FCC Part 15 Class B Registration Warning
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interfer-
ence to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit, different
from that which the receiver is connected (if applicable).
(4) Consult the dealer or an experienced radio/TV technician
for help.
INSTALLING THE BATTERY
Press battery door release with a coin and
1
remove door.
Stud Edge
Groove
Connect battery to cable and place inside
2
battery compartment. Replace battery door
LED Sensing
and snap shut. Battery will last approximately two
Display
years under normal conditions.
®
TruCal
LED
TURNING THE POWER ON/OFF
ON: Press and hold ON/OFF button on the left
3
side. OFF: Release ON/OFF button.
Mode Selector
Switch
Note: the Triscanner Pro SL will automatically turn
off after 15 minutes of continuous use (in case
battery button is accidently held down in a toolbox.)
Battery Door
(Back of unit)
SELECTING MODE: STUD SCAN,
STUD DEEPSCAN
®
Use Stud Scan mode for depths to about
(19 mm) and Stud DeepScan for depths up to
1
1
⁄
in. (38 mm) or double layers.
2
Slide the Mode selector switch until you reach
4
desired scanning mode. The mode can be
selected with the unit on or off.
CALIBRATING IN STUD SCAN OR
STUD DEEPSCAN MODES
Keep unit flat against wall
during calibration or scanning.
5
Position the TriScanner
Pro SL flat against the
wall. Select mode. Press and
hold On/Off button.
HELPFUL HINTS
Situation
Over-the-Stud Indicator.
• Scan began over a stud.
(Flashing lights)
• Unit not flat against wall.
• Unit tilted or lifted during
Working in DeepScan
• You may have calibrated over
mode and can’t detect
studs.
• You may be holding the unit
Detects other objects
• Electrical wiring and metal/
besides studs in stud
Scan and DeepScan
modes.
You suspect electrical
• If wires are shielded behind
wires, but do not
detect any.
• The wires may not be HOT.
• Wires may be too deep to
Area of voltage
• Static charge may develop on
detection is too large.
Red LEDs light but center
• Wall is particularly thick
pair of green LEDs don’t.
Difficulty detecting
• Unit calibrated over metal.
metal.
• Metal targets are too deep.
Image of metal stud
• Metal has greater density
appears wider than
actual size.
Red LEDs do not light up
• Battery voltage is low.
as you test the unit with
your free hand moving
toward the back of the
TriScanner Pro SL.
Questions? Check our Web site at www.zircon.com and click «Product Support.»
Mode LED and TruCal
6
quickly and then stay lit. TriScanner Pro SL
automatically calibrates in less than one second.
SCANNING IN STUD SCAN OR STUD
DEEPSCAN MODES
Slowly slide unit
7
horizontally across wall,
9 VOLT
BATTERY
left or right.
When center pair of
8
green LEDs light,
steady tone sounds, and the
SpotLite
®
Pointing System
shines, you have found the
stud edge. Mark this spot.
Continue holding
9
On/Off button in and
scan beyond marked spot until
the center green and 3 pairs
of red LEDs go out.
, OR METAL SCAN
Without releasing On/Off
10
3
⁄
in.
4
button, slide unit in reverse
direction to locate the other edge
of stud. Mark this second spot.
Middle of stud is centered
between the two marks.
CALIBRATING IN METAL MODE
Select Metal mode. Press
11
and hold ON/OFF button.
Calibrate TriScanner Pro SL in air,
away from metal objects. Position
unit flat against wall.
Probable Causes
• Turn unit off, move over a few inches, and start again.
• Hold unit with thumb and index finger no higher than
handgrips.
scan. (All these factors affect
• On rough surfaces, place a piece of paper on wall,
proper calibration.)
scanning through it to help slide unit more smoothly.
• In Stud Scan or DeepScan modes, hold unit parallel to
and move perpendicular to object you’re trying to locate.
• Move TriScanner Pro SL over a few inches and recalibrate.
a stud. (The error condition is
disabled in DeepScan mode
because it is twice as
sensitive as Stud Scan.)
• Hold the TriScanner Pro SL so that the two Velcro™ strips
like a TV remote, aiming it at
on the back make contact with the wall.
the wall.
• Switch to Metal mode, where combined with continuous
plastic pipes may be near or
AC detection, pipes and electrical wiring should be
touching back surface of
detected adequately.
wall.
• Use CAUTION when nailing, cutting, or drilling in walls,
metallic wall coverings, or in
floors, and ceilings that may contain wiring.
metal conduit, TriScanner Pro
• Use extra caution if the area has plywood, thick wood
SL will not be able to find
backing behind drywall, or thicker than normal walls.
them.
• Remember that studs or joists are normally spaced
16 in. (406 mm) or 24 in. (610 mm) apart and are 1
(38 mm) wide.
sense.
• If a switch controls an outlet, make sure it is ON for detection.
• To narrow detection, turn unit off and on again at the edge
drywall, spreading voltage
of where wire was detected and scan again.
detection as much as 12 in.
• Place free hand flat against wall near tool to discharge
(305 mm) from each side.
static.
• Interpret pair of red LEDs closest to center as stud edge.
or dense.
• Switch to DeepScan to locate the stud.
• Always calibrate in the air for best sensitivity and to avoid
calibrating over metal.
• Scan in both horizontal and vertical directions. Sometimes
metal sensitivity is greater when metal object is parallel to
sensor, which is along top of unit.
• To narrow image, scan and mark first indications and then
than wood and is sensed
calibrate TriScanner Pro SL over either of the first two marks.
farther from edge.
Scan again and mark the new, narrowed detection points.
Repeat if necessary.
• Replace battery to maintain sensitivity.
®
LED will flash
Solutions
1
⁄
in.
2
Производитель Zircon
Категория Stud Sensor
Документы, которые мы получаем от производителя устройства Zircon Pro SL мы можем разделить на несколько групп. Это в частности:
— технические чертежи Zircon
— инструкции обслуживания Pro SL
— паспорта изделия Zircon
— информационные брошюры
— энергетические этикетки Zircon Pro SL
Все из них важны, однако самую важную информацию с точки зрения пользователя мы найдем в инструкции обслуживания Zircon Pro SL.
Группа документов, определяемая как инструкции обслуживания, делится также на более подробные типы, такие как: Инструкции монтажа Zircon Pro SL, инструкции обслуживания, короткие инструкции или инструкции пользователя Zircon Pro SL. В зависимости от потребностей, Вам необходимо поискать требуемый документ. На нашем сайте Вы можете просмотреть самую популярную инструкцию использования изделия Zircon Pro SL.
Полная инструкция обслуживания устройства Zircon Pro SL, как должна выглядеть?
Инструкция обслуживания, определяемая также как пособие пользователя, или просто «руководство» — это технический документ, цель которого заключается в использовании Zircon Pro SL пользователями. Инструкции пишет, как правило технический писатель, языком, доступным для всех пользователей Zircon Pro SL.
Полная инструкция обслуживания Zircon, должна заключать несколько основных элементов. Часть из них менее важная, как например: обложка / титульный лист или авторские страницы. Однако остальная часть, должна дать нам важную с точки зрения пользователя информацию.
1. Вступление и рекомендации, как пользоваться инструкцией Zircon Pro SL — В начале каждой инструкции, необходимо найти указания, как пользоваться данным пособием. Здесь должна находится информация, касающаяся местонахождения содержания Zircon Pro SL, FAQ и самых распространенных проблем — то есть мест, которые чаще всего ищут пользователи в каждой инструкции обслуживания
2. Содержание — индекс всех советов, касающихся Zircon Pro SL, которое найдем в данном документе
3. Советы по использованию основных функций устройства Zircon Pro SL — которые должны облегчить нам первые шаги во время использования Zircon Pro SL
4. Troubleshooting — систематизированный ряд действия, который поможет нам диагностировать а в дальнейшем очередность решения важнейших проблем Zircon Pro SL
5. FAQ — чаще всего задаваемые вопросы
6. Контактные данные Информация о том, где искать контактные данные производителя / сервисного центра Zircon Pro SL в данной стране, если самостоятельно не получится решить проблему.
TriScanner
Stud & Metal Locator with AC Warning
The Zircon TriScanner
®
Pro SL
scanner detects wood or metal
studs, metal pipes, and hot
Metal Sensor
electrical wires in interior walls,
floors, and ceilings, as well as
AC LED
rebar in concrete. It features
the SpotLite
®
Pointing System,
Stud Scan
three different scanning modes
Mode LED
plus continuous hot electrical
wire detection.
Stud DeepScan
Mode LED
Metal Scan
Mode LED
On/Off Button
(Side of unit)
LIMITED 1 YEAR WARRANTY
Zircon Corporation, («Zircon») warrants this product to be free from defects
in materials and workmanship for one year from the date of purchase. Any
in-warranty defective product returned to Zircon*, freight prepaid with proof
of purchase date and $5.00 to cover postage and handling, will be repaired or
replaced at Zircon’s option. This warranty is limited to the electronic circuitry
and original case of the product and specifically excludes damage caused by
abuse, unreasonable use or neglect. This warranty is in lieu of all other
warranties, express or implied, and no other representations or claims of any
nature shall bind or obligate Zircon. Any implied warranties applicable to this
product are limited to the one year period following its purchase.
IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR
CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE OR
MALFUNCTION OF THIS PRODUCT.
In accordance with government regulations, you are advised that:
(i) some states do not allow limitations on how long an implied warranty lasts
and/or the exclusion or limitation of incidental or consequential damages, so
the above limitations and/or exclusions may not apply to you, and further (ii)
SCANNING IN METAL MODE
Metal can be detected up to 1
1
⁄
in. (38 mm) deep
2
in walls and up to 3 in. (77 mm) deep in concrete.
While holding in On/Off
12
button, slowly move unit
on surface, to locate targets.
Reverse directions to locate other
edge of target. Lights will indicate
metal in the same way as in find-
ing studs. When tone sounds,
LEDs light up, and SpotLite comes on, you are close
to metal. Mark this spot to help ensure that you’re
not nailing into a pipe.
CONTINUOUS AC VOLTAGE
DETECTION
The TriScanner Pro SL detects from 90 to 250 V
13
at 50 to 60 Hz AC in a HOT unshielded
electrical wire that is within 1
1
⁄
in. (38 mm) of
2
wall surface. The voltage detection feature works
continuously in all modes. The sensor is located in the
center of the back of the unit.
Caution: The TriScanner Pro SL will not detect hot
wires inside metal pipe or metal conduit, behind
metallic wall covering, or behind some plywood or
other dense materials. Use extra caution in these
construction situations. Always turn the power
off when nailing, cutting, or drilling near
electrical wires.
VERIFYING IF THE UNIT WORKS
Turn unit on in the air.
14
If the LEDs light when
you bring your hand up to the
back, then the unit is working
properly.
The AC LED should
15
light with an electrical
cord an inch or two away.
®
Pro SL
®
SpotLite
Pointing System
®
TRISCANNER
PRO SL
this warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
Return product freight prepaid with proof of purchase date (dated sales
receipt) and $5.00 to cover postage and handling, to:
Zircon Corporation
*Attn: Returns Department
2390 Boswell Road, Suite 300
Chula Vista, CA 91914-3510 USA
Be sure to include your name and return address. Out of warranty service and
repair, where proof of purchase is not provided, shall be returned with repairs
charged C.O.D. Allow 4 to 6 weeks for delivery.
Customer Service, 1-800-245-9265 or 1-408-866-8600
Monday–Friday, 8 a.m. to 5 p.m. PST
E-mail: customer.service@zircon.com
U.S. Patent #4464622, 5352974, 5619128, 6023159, 6249113, 6259241,
D419546, D419149, D419545, D427166, and D419544
Canada Patent #1106932 • G.B. Patent #2117909B, 2159630B
©2002 Zircon Corporation • P/N 58756 • Rev B 11/02
OPERATING CAUTIONS
Depending on the proximity of electrical wiring
16
or pipes to the wall surface, the scanner may
detect them in the same manner as studs. Caution
should always be used when nailing, cutting, or
drilling in walls, floors, and ceilings that may contain
these items.
To avoid surprises, remember that studs or joists are
normally spaced 16 in. (406 mm) or 24 in. (610 mm)
apart and are 1
1
⁄
in. (38 mm) in width. Anything
2
closer together or a different width may not be a
stud, joist, or firebreak. Always turn off the power
when working near electrical wires.
WORKING WITH DIFFERENT MATERIALS
Wallpaper: TriScanner Pro SL functions normally on
walls covered with wallpaper or fabric, unless the
materials are metallic foil, contain metallic fibers, or
are still wet after application.
Textured Ceilings: When scanning on an uneven
surface, place thin cardboard on ceiling and scan over
the cardboard. Calibrate with cardboard in place.
Note: TriScanner Pro SL cannot scan through
carpeting and pad or, in most cases, lath and plaster.
If you are having difficulty scanning through any of
these or other materials, use the Metal mode to
locate nails in the stud or joist. Try to locate several
nails to get a better idea of how the stud is oriented.
FCC Part 15 Class B Registration Warning
This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in
a residential installation. This equipment generates, uses, and
can radiate radio frequency energy and, if not installed and used
in accordance with the instructions, may cause harmful interfer-
ence to radio communications. However, there is no guarantee
that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment
off and on, the user is encouraged to try to correct the interfer-
ence by one or more of the following measures:
(1) Reorient or relocate the receiving antenna.
(2) Increase the separation between the equipment and receiver.
(3) Connect the equipment into an outlet on a circuit, different
from that which the receiver is connected (if applicable).
(4) Consult the dealer or an experienced radio/TV technician
for help.
INSTALLING THE BATTERY
Press battery door release with a coin and
1
remove door.
Stud Edge
Groove
Connect battery to cable and place inside
2
battery compartment. Replace battery door
LED Sensing
and snap shut. Battery will last approximately two
Display
years under normal conditions.
®
TruCal
LED
TURNING THE POWER ON/OFF
ON: Press and hold ON/OFF button on the left
3
side. OFF: Release ON/OFF button.
Mode Selector
Switch
Note: the Triscanner Pro SL will automatically turn
off after 15 minutes of continuous use (in case
battery button is accidently held down in a toolbox.)
Battery Door
(Back of unit)
SELECTING MODE: STUD SCAN,
STUD DEEPSCAN
®
Use Stud Scan mode for depths to about
(19 mm) and Stud DeepScan for depths up to
1
1
⁄
in. (38 mm) or double layers.
2
Slide the Mode selector switch until you reach
4
desired scanning mode. The mode can be
selected with the unit on or off.
CALIBRATING IN STUD SCAN OR
STUD DEEPSCAN MODES
Keep unit flat against wall
during calibration or scanning.
5
Position the TriScanner
Pro SL flat against the
wall. Select mode. Press and
hold On/Off button.
HELPFUL HINTS
Situation
Over-the-Stud Indicator.
• Scan began over a stud.
(Flashing lights)
• Unit not flat against wall.
• Unit tilted or lifted during
Working in DeepScan
• You may have calibrated over
mode and can’t detect
studs.
• You may be holding the unit
Detects other objects
• Electrical wiring and metal/
besides studs in stud
Scan and DeepScan
modes.
You suspect electrical
• If wires are shielded behind
wires, but do not
detect any.
• The wires may not be HOT.
• Wires may be too deep to
Area of voltage
• Static charge may develop on
detection is too large.
Red LEDs light but center
• Wall is particularly thick
pair of green LEDs don’t.
Difficulty detecting
• Unit calibrated over metal.
metal.
• Metal targets are too deep.
Image of metal stud
• Metal has greater density
appears wider than
actual size.
Red LEDs do not light up
• Battery voltage is low.
as you test the unit with
your free hand moving
toward the back of the
TriScanner Pro SL.
Questions? Check our Web site at www.zircon.com and click «Product Support.»
Mode LED and TruCal
6
quickly and then stay lit. TriScanner Pro SL
automatically calibrates in less than one second.
SCANNING IN STUD SCAN OR STUD
DEEPSCAN MODES
Slowly slide unit
7
horizontally across wall,
9 VOLT
BATTERY
left or right.
When center pair of
8
green LEDs light,
steady tone sounds, and the
SpotLite
®
Pointing System
shines, you have found the
stud edge. Mark this spot.
Continue holding
9
On/Off button in and
scan beyond marked spot until
the center green and 3 pairs
of red LEDs go out.
, OR METAL SCAN
Without releasing On/Off
10
3
⁄
in.
4
button, slide unit in reverse
direction to locate the other edge
of stud. Mark this second spot.
Middle of stud is centered
between the two marks.
CALIBRATING IN METAL MODE
Select Metal mode. Press
11
and hold ON/OFF button.
Calibrate TriScanner Pro SL in air,
away from metal objects. Position
unit flat against wall.
Probable Causes
• Turn unit off, move over a few inches, and start again.
• Hold unit with thumb and index finger no higher than
handgrips.
scan. (All these factors affect
• On rough surfaces, place a piece of paper on wall,
proper calibration.)
scanning through it to help slide unit more smoothly.
• In Stud Scan or DeepScan modes, hold unit parallel to
and move perpendicular to object you’re trying to locate.
• Move TriScanner Pro SL over a few inches and recalibrate.
a stud. (The error condition is
disabled in DeepScan mode
because it is twice as
sensitive as Stud Scan.)
• Hold the TriScanner Pro SL so that the two Velcro™ strips
like a TV remote, aiming it at
on the back make contact with the wall.
the wall.
• Switch to Metal mode, where combined with continuous
plastic pipes may be near or
AC detection, pipes and electrical wiring should be
touching back surface of
detected adequately.
wall.
• Use CAUTION when nailing, cutting, or drilling in walls,
metallic wall coverings, or in
floors, and ceilings that may contain wiring.
metal conduit, TriScanner Pro
• Use extra caution if the area has plywood, thick wood
SL will not be able to find
backing behind drywall, or thicker than normal walls.
them.
• Remember that studs or joists are normally spaced
16 in. (406 mm) or 24 in. (610 mm) apart and are 1
(38 mm) wide.
sense.
• If a switch controls an outlet, make sure it is ON for detection.
• To narrow detection, turn unit off and on again at the edge
drywall, spreading voltage
of where wire was detected and scan again.
detection as much as 12 in.
• Place free hand flat against wall near tool to discharge
(305 mm) from each side.
static.
• Interpret pair of red LEDs closest to center as stud edge.
or dense.
• Switch to DeepScan to locate the stud.
• Always calibrate in the air for best sensitivity and to avoid
calibrating over metal.
• Scan in both horizontal and vertical directions. Sometimes
metal sensitivity is greater when metal object is parallel to
sensor, which is along top of unit.
• To narrow image, scan and mark first indications and then
than wood and is sensed
calibrate TriScanner Pro SL over either of the first two marks.
farther from edge.
Scan again and mark the new, narrowed detection points.
Repeat if necessary.
• Replace battery to maintain sensitivity.
®
LED will flash
Solutions
1
⁄
in.
2
Русский
- Bedienungsanleitung Zircon Pro SL
- Zircon Pro SL User Manual
- Manual Usuario Zircon Pro SL
- Mode d’emploi Zircon Pro SL
- Istruzioni Zircon Pro SL
- инструкция Zircon Pro SL
- Zircon Pro SLの取扱説明書
- Handleiding Zircon Pro SL
- Manual de uso Zircon Pro SL
Вам нужна инструкция? Мы поможем Вам ее найти и сэкономить Ваше время.
- 1 stron
- 0.28 mb
Изделие Zircon Pro SL, а также другие, которыми Вы пользуетесь ежедневно, наверняка вы получили в комплекте с инструкцией обслуживания. Из опыта наших пользователей мы знаем, что большинство из Вас не уделили этому особого внимания. Большая часть инструкций, сразу же после покупки попадает в корзину для мусора вместе с коробкой — это ошибка. Ознакомьтесь с информацией, касающейся инструкции Zircon Pro SL, которая поможет Вам в будущем сэкономить нервы и избежать головной боли.
Важная подсказка — не забывайте хотя бы раз прочитать инструкцию Zircon Pro SL
Если вы не хотите каждый раз читать информационные брошюры, касающиеся, тех или Zircon Pro SL иных изделий, достаточно, прочитать их раз — сразу же после покупки устройства. Вы получите основное знания, касающиеся поддержания изделия Zircon Pro SL в хорошем эксплуатационном состоянии, так, чтобы без проблем достигнуть его планируемого цикла работы. Затем инструкцию можно отложить на полку и вернуться к ней только в случае, если вы не уверены, правильно ли проводится техобслуживание изделия. Правильный уход является необходимым элементом Вашего удовольствия Zircon Pro SL.
Раз в году пересмотрите шкафчик, в котором держите инструкции для всех устройств, — выбросите те, которыми вы уже не пользуетесься. Это поможет Вам сохранять порядок в своей домашней базе инструкций обслуживания.
Summary of Contents for Zircon Pro SL
Что находится в инструкции Zircon Pro SL? Почему стоит ее прочитать?
- Гарантия и подробности, касающиеся техобслуживания изделия
Хорошей идеей будет прикрепить чек к странице инструкции. Если что-то плохое случится во время использования Zircon Pro SL, у вас будет комплект документов, необходимый для гарантийного ремонта. В этой части инструкции вы найдете информацию об авторизованных сервисных центрахZircon Pro SL а также, как самостоятельно правильно ухаживать за оборудованием — так, чтобы не потерять гарантийных прав. - Указания по монтажу и Setup
Не терять нервов и времени на самостоятельную попытку установки и первого запуска изделия. Воспользуйтесь рекомендациями производителя Zircon Pro SL чтобы правильно запустить изделие, без лишнего риска повреждения оборудования. - Информация, касающаяся дополнительных запчастей (входящих в комплект а также являющихся опцией)
Пересматривая эту часть документа вы сможете проверить, доставлен ли ваш Zircon Pro SL с полним комплектом аксессуаров. Вы также сможете узнать, какие дополнительные запчасти или аксессуары для Zircon Pro SL Вы сможете найти и докупить к своему устройству. - Troubleshooting
Самые частые проблемы, касающиеся Zircon Pro SL и методы их решения. Это очень полезная часть руководства по обслуживанию — она позволит Вам сэкономить много времени на поиск решений. 90% проблем с Zircon Pro SL повторяется у многих пользователей. - Требования, касающиеся питания и энергетический класс
Информация, касающаяся количества потребляемой энергии, а также рекомендации, касающиеся установки и питания Zircon Pro SL. Прочитайте, чтобы оптимально пользоваться Zircon Pro SL и не использовать большего количества ресурсов, нежели это необходимо для правильной работы изделия. - Специальные функции Zircon Pro SL
Здесь вы можешь узнать, как персонализировать изделие Zircon Pro SL. Вы узнаете, какие дополнительные функции могут помочь Вам удобно использовать продукт Zircon Pro SL а также, какие функции Вашего устройства оптимальны для выполнения конкретной деятельности.
Как видите в инструкции вы найдете информацию, которая реально поможет Вам в использовании Вашего изделия. Стоит с ней ознакомиться, чтобы избежать разочарований, возникающих из более короткого, нежели предусматривалось, периода исправности изделия Zircon Pro SL. Если все же вы не хотите копить инструкции в своем доме, наш сайт поможет Вам в этом — вы должны найти у нас руководство по обслуживанию большинства из своих устройств, а также Zircon Pro SL.
Комментарии (0)
Устройство:
Zircon Pro SL
Размер: 0,3 MB
Добавлено: 2014-02-04
Количество страниц: 1
Как пользоваться?
Наша цель — обеспечить Вам самый быстрый доступ к руководству по эксплуатации устройства Zircon Pro SL. Пользуясь просмотром онлайн Вы можете быстро просмотреть содержание и перейти на страницу, на которой найдете решение своей проблемы с Zircon Pro SL.
Для Вашего удобства
Если просмотр руководства Zircon Pro SL непосредственно на этой странице для Вас неудобен, Вы можете воспользоваться двумя возможными решениями:
- Полноэкранный просмотр -, Чтобы удобно просматривать инструкцию (без скачивания на компьютер) Вы можете использовать режим полноэкранного просмотра. Чтобы запустить просмотр инструкции Zircon Pro SL на полном экране, используйте кнопку Полный экран.
- Скачивание на компьютер — Вы можете также скачать инструкцию Zircon Pro SL на свой компьютер и сохранить ее в своем архиве. Если ты все же не хотите занимать место на своем устройстве, Вы всегда можете скачать ее из ManualsBase.
Zircon Pro SL Руководство по эксплуатации — Online PDF
Ознакомьтесь с подробным руководством пользователя для замечательного творения Zircon, модель Pro SL. Получите ценную информацию и инструкции, чтобы максимально использовать возможности вашего устройства и оптимизировать взаимодействие с пользователем. Раскройте весь потенциал своего устройства Zircon Pro SL с помощью этого подробного руководства пользователя, в котором содержатся пошаговые инструкции и советы экспертов, которые сделают работу с ним легкой и приятной.
Печатная версия
Многие предпочитают читать документы не на экране, а в печатной версии. Опция распечатки инструкции также предусмотрена и Вы можете воспользоваться ею нажав на ссылку, находящуюся выше — Печатать инструкцию. Вам не обязательно печатать всю инструкцию Zircon Pro SL а только некоторые страницы. Берегите бумагу.
Резюме
Ниже Вы найдете заявки которые находятся на очередных страницах инструкции для Zircon Pro SL. Если Вы хотите быстро просмотреть содержимое страниц, которые находятся на очередных страницах инструкции, Вы воспользоваться ими.